KMC Controls STE-6010 Installation guide

Type
Installation guide

KMC Controls STE-6010 is a precise and versatile room temperature sensor designed for various indoor applications.

With its compact design and multiple mounting options, STE-6010 can be easily installed on walls or in 2 x 4 inch handy boxes, making it suitable for a wide range of environments. The device features a screw-clamp terminal block for secure wire connections.

STE-6010 accurately measures room temperature using a thermistor and transmits the data via an RJ-45 connector to a controller or other compatible devices. It provides reliable temperature monitoring for applications like HVAC systems, building automation, and environmental control.

KMC Controls STE-6010 is a precise and versatile room temperature sensor designed for various indoor applications.

With its compact design and multiple mounting options, STE-6010 can be easily installed on walls or in 2 x 4 inch handy boxes, making it suitable for a wide range of environments. The device features a screw-clamp terminal block for secure wire connections.

STE-6010 accurately measures room temperature using a thermistor and transmits the data via an RJ-45 connector to a controller or other compatible devices. It provides reliable temperature monitoring for applications like HVAC systems, building automation, and environmental control.

STE-6010/6011/6013/6015 Room Temperature Sensors 1 Installation Guide
2.438
2.250
R 3.094
R .187
.643 .450
STE-6013 STE-6011
.475
max.
STE-6010/6015
Modular
RJ-45
Jack
Four-pin
EIA-485
PC Data
Port
Clamp
(Screw-type)
Terminals
Clamp
(Screw-type)
Terminals
.149
Installation Guide
Room Temperature Sensors
STE-6010/6011/6013/6015
Mounting 1
Location and Cover Removal 1
STE-6010/6013/6015 Only 1
STE-6011 Only 1
Controller Connection 2
STE-6010/6015 2
STE-6011 2
STE-6013 2
Maintenance 2
More Information 2
Mounting
4. Aachthecabletotheterminalblockorjack
accordingtotheappropriatewiringdiagramon
thenextpage.
5. Replacethecover.
STE-6011 Only
Handy Box Installation (Recommended)
1. MountauniversalbackplateHMO-6036tothe
handyboxusingthetwoscrewsprovided.
2. Removethecoverfromthebackpanel.
3. AachwiresaccordingtotheSTE-6011wiring
diagramonthenextpage.
4. Aachthebackpaneltothebackplateusingtwo
screws.
5. Checkthatleadstothethermistorarestraight
andthethermistoriscompletelyextended.
6. Replacethecover.
Hollow Wall Installation
1. Removethecoverfromthebackpanel.
2. Usethebackpanelasatemplatetodrilltwo
holesformountingscrews(7/64inchesor3mm
indiameterand1.4inches,1-13/32inches,or35.6
mmapart)andtocutacenterhole(7/8inchor20
mm)fortheterminalblockorjack.
3. AachwiresaccordingtotheSTE-6011wiring
diagramonthenextpage.
4. Aachthebackpaneltothewallusingtwo
#6self-threadingscrews.(Plasticanchorsare
recommended,andthesizeoftheholeswillthen
needadjusting.)
5. Checkthatleadstothethermistorarestraight
andthethermistoriscompletelyextended.
6. Replacethecover.
All dimensions
are in inches
Location and Cover Removal
Installthesensoronaninsidewallwhereitcansense
theaverageroomtemperatureandbeawayfrom
directsunlight,heatsources,windows,airvents,
andaircirculationobstructions(curtains,furniture,
etc.).Itcanbemountedonahollowwallor(with
auniversalbackplateHMO-6036/6036W)toa2x4
inchhandybox.
Thecoverisheldtotheblack,backpanelbythree,
small,roundpegsthattintheholesofthecover.
Theboompegisonatabandsnapsintothecenter
boomhole.
1. WithasmallPhillipsscrewdriverorhexwrench,
press in and hold the tab buon that snaps into
the center hole on the boom cover.
2. Carefullypullorprythebackpanelfromthe
frontcover.
STE-6010/6013/6015 Only
Handy Box Installation (Recommended)
1. Mountauniversalbackplate
HMO-6036orHMO-6036Wtothe
handyboxusingthetwoscrews
provided.
2. Removethecoverfromthebackpanel.
3. Aachthebackpaneltothebackplateusingthe
twoscrewsprovided.
4. Aachthecabletotheterminalblockorjack
accordingtotheappropriatewiringdiagramon
thenextpage.
5. Replacethecover.
Hollow Wall Installation
1. Removethecoverfromthebackpanel.
2. Usingthebackpanelasatemplate,drilltwoholesfor
mountingscrews(7/64inchesor3mmindiameter
and1.4inches,1-13/32inches,or35.6mmapart)and
cutacenterhole(sizeneededisdependentonmodel)
fortheterminalblockorjack.
3. Aachthebackpaneltothewallusingtwo
#6self-threadingscrews.(Plasticanchorsare
recommended,andthesizeoftheholeswillthen
needadjusting.)
STE-6010/6011/6013/6015 Room Temperature Sensors 2 Installation Guide
STE-6013
STE-6011
Controller Connection
Connectwiresasshownfortherelevantmodel.
Thermistor (10K Ohms)
(Wires are
interchangeable)
ConnectinganSTE-6010/6015toaKMCcontroller
requiresaspecialcablewith(onthesensorend)an
RJ-45modularconnectorand(onthecontrollerend)
anRJ-11modularconnectorwithadditionalwiresfor
KMCcontrollerinputs.Purchasingpre-assembled
cablesfromKMCismorecost-eectiveandreliable
thancreatingcustomcablesintheeld.Useoneof
thefollowingcables:
• KMD-5693=25feet
• KMD-5694=50feet
• KMD-5695=75feet
Theadditionalwireconnectionstothecontrollerare:
Orangeisthethermistorsignaltothecontrollers
appropriateinput
Greenistheoptional10 VDC supply voltage
fromanoutputofacontrollertotheSTE-6015
LED(fortheSTE-6010,cliportapetheunused
wire)
Orange/whiteshouldbeclippedortapedback
sinceasetpointsignalisnotusedwithanSTE-
6010/6015
STE-6010/6015
KMD–5693 = 25 feet; KMD–5694 = 50 feet; KMD–5695 = 75 feet
1 8
Orange Wire = Thermistor Input to Controller
Orange/White Wire = Setpoint Signal Input to Controller
(for STE-6014/6016/6017/6018 only; clip or tape when not used)
12 inches
52
RJ-11 and
Wire Leads
to Controller
RJ-45
to STE
Sensor
Green Wire = Aux. Supply Voltage to STE-6015/6018
(10 VDC) or STE-6016 (7.5/12 VDC) (clip or tape when not used)
RJ-11 RJ-45 Color
(Lead) 8 Orange
7 N.C.
(Lead) 6 Green
3 5 Blue
4 4 Blue/White
5 3 Green/White
2 N.C.
(Lead) 1 Orange/White
(Cables crossed, 20 AWG)
Common (“Ground”)
Thermistor (10K Ohms)
D
B
C
10 VDC LED Supply (from Controller)
(Override
Button)
Up (Toward Ceiling at Installation)
Maintenance
Carefulinstallationwillalsoensurelong-term
reliabilityandperformance.Removedustasneces-
saryfromholesintopandboom.Cleanwithaso,
dampclothandmildsoap.
© 2012 KMC Controls, Inc. 866-019-03C
KMC Controls, Inc.
19476IndustrialDrive
NewParis,IN46553
574.831.5250
www.kmccontrols.com;[email protected]
More Information
Model
Number
Interface
Features
Cable
Connections
Override
Button
LED
Status
Indicator
Screw
Clamp
Terminals
RJ-45
Connector
EIA-485
Data
Port
STE-6010-10 X X
STE-6011-10 X
STE-6013-10 X X X
STE-6015-10 X X X X
STE-6010/6011 STE-6013/6015
Formountingconsiderations,net-
workconnection,controllercon-
guration,programming,trouble-
shooting,andotherinformation,
seetheSTE-6010/6011/6013/6015
Application Guide.
Forgeneralproductinformation,
seetheSTE-6000 Series Room
Temperature Sensors/Transmit-
ters Data SheetontheKMC
Controlswebsite.
  • Page 1 1
  • Page 2 2

KMC Controls STE-6010 Installation guide

Type
Installation guide

KMC Controls STE-6010 is a precise and versatile room temperature sensor designed for various indoor applications.

With its compact design and multiple mounting options, STE-6010 can be easily installed on walls or in 2 x 4 inch handy boxes, making it suitable for a wide range of environments. The device features a screw-clamp terminal block for secure wire connections.

STE-6010 accurately measures room temperature using a thermistor and transmits the data via an RJ-45 connector to a controller or other compatible devices. It provides reliable temperature monitoring for applications like HVAC systems, building automation, and environmental control.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI