Airpura Industries F614 User guide

Type
User guide

This manual is also suitable for

To close the lter chamber
Replace
the gasket
Position the
indentation in the cover
into the center of the
HEPA lter
Replace
the 4 screws
and tighten
Turn the Airpura
back on casters
OPER ATING
&
FILTER REPLACEMENT
DIRECTIONS
F600
Insert the tube
into the lter
chamber inside
the Prelter
Let the spiral
open to ll
the opening
Open the top of the
spiral to make a
slight funnel
Insert the
Carbon canister into
the funnel and hold it
straight
Position the
Prelter inside
the lter
chamber
Place a felt gasket at
the bottom of the
lter chamber
Unfold the lter slider
(Supplied with replacement
lters or on request
Part#6F 001)
Roll it
into a spiral
Let the canister
slide down
thelter slider
Pull the lter slider up
out of the cavity using
both hands and let the
canister slide to the
bottom of the cavity
Remove the lter
slider and fold it
for further use
Slide in the
Hepa lter
To open the lter chamber
Turn over
the Airpura
Remove the 4
retaining screws
Take of f
the cover
Remove
the gasket
Air puriers models and lter congurations
Technical specications
3067330 60950
Poly Prelter 600 2-pack
12 months
HEPA 600RVHU lter
(99.97 % ecient)
3 to 5 years
F614 : HEPA 14 lter
(99.99 % ecient)
18 lbs, Impregnated Carbon
Filter 35% potassium
permaganate carbon, 65%
coconut shell
24 months
Odors, airborne chemical control
18 lbs enhanced Carbon
13"H x 13.25"OD x 9"ID
Particle removal
40 ft2 true HEPA
(Measured 1 side only)
7-12 pleats per inch
Pleats warm rolled with separators
Air Flow 560 cfm
More cfm than any other
home unit available
Prelter
570 in2 x 1 in
Housing
Powder coat steel
Size
23 in x 15 in
Weight
45 lbs total
Watts
120 on high / 40 on low
Sound Level at 6 feet
34.2 db on low
57.2 db on high
(Room Level 25.1)
Possible upgrade  :
UV Germicidal Lamp, 20 Watt
Prelter Particule
Alternates Cotton Prelter
TarBarrier Prelter
Upgrade HEPA 14 lter
(99.99 % ecient @ 0.3 microns)
ULPA lter
(99.9999 % ecient@ 0.1 microns)
TO BEGIN USING YOUR
AIRPURA
Inspect the exterior of your Airpura to verify there is no damage from shipping.
If any damage is noted, please follow the instructions from the distributor returns
policy.
Wipe the unit with a damp cloth to remove any dust from packaging
Plug the unit into a regular grounded 110 volt outlet
Turn on the unit to MAX and allow it to run for at least 30 minutes
Set the variable speed control to the level you wish
The most ecient way to use your Airpura for regular air quality maintenance
is to run it at a low speed 24 hours a day 7 days a week.
Always maintain a humidity level of 40% or less in your home to ensure the
unit is operating at optimal levels. Overly humid conditions can have an
adverse effect on the performance of the carbon. When using purier with a
dehumidier, please keep dehumidier at least 6 feet away.
FILTER MAINTENANCE AND REPLACEMENT
The Prelter
Can be vacuumed from the exterior of the unit once a month or more often.
Should be replaced at least after 12 months of use
To vacuum the Prelter
Use the brush attachment on your vacuum cleaner
Vacuum slowly around the mesh surface of the lter chamber
IMPORTANT SAFETY NOTE
Please ensure air purier is turned OFF when plugging into a power source.
Failure to do so may result in motor potentially stalling and/or burning.
MinMax
Off
1
MinMax
Off
2
MinMax
Off
3
  • Page 1 1