Kozyheat Lakefield XL Owner's manual

Category
Fireplaces
Type
Owner's manual
Hussong Mfg. Co, Inc. 1 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
INSTALLATION AND
OPERATION MANUAL
Lakefield XL
Model #LXL-22-L & LXL-22-MV
Direct Vent Gas Stove
English and French installation manuals are available
through your local dealer. Visit our website
www.kozyheat.com.
Les manuels dinstallation en français et en anglais sont
disponibles chez votre détaillant local. Visitez
www.kozyheat.com.
Hussong Mfg. Co, Inc. 2 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
Hussong Mfg. Co, Inc. 3 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
Hussong Manufacturing welcomes you as a new owner of a Kozy Heat gas fireplace. Kozy Heat
products are designed with superior components and materials, assembled with care by trained
craftsmen who take pride in their work. To ensure you receive a quality product, the burner and
valve assembly are 100 percent test-fired, and the complete fireplace is thoroughly inspected be-
fore packaging. Our commitment to quality and customer satisfaction has remained the same for
over 40 years. We offer a complete line of gas, wood, and electric fireplaces, along with stylish ac-
cessories to complement any decor. Adding a fireplace is one of the best ways to increase the
value of your home, and we are proud to offer a network of dealers throughout the country to
help make your experience everything you imagine. We pride ourselves in being dedicated not
only to functionality and reliability, but also customer safety. We offer our continual support and
guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas
fireplace.
Jim Hussong
President
Dudley Hussong
Board Chairman
Homeowner Reference Informaon We recommend you record the following Informaon:
Model Name: ______________________________ Date Purchased / Installed: _______________________________
Serial Number: _____________________________ Locaon of replace: ____________________________________
Dealership purchased from: _________________________________________________________________________________
Dealership phone number: ____________________
Notes: __________________________________________________________________________________________________
________________________________________________________________________________________________________
________________________________________________________________________________________________________
Read this manual before installing or operang this appliance
Please retain this owners manual for future reference.
Hussong Mfg. Co, Inc. 4 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
Hussong Mfg. Co, Inc. 5 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
HOMEOWNER REFERENCE INFORMATION .................... 3
TABLE OF CONTENTS ..................................................... 5
1.0 Introducon .......................................................... 7
1.1 Appliance Cercaon ........................................7
1.2 California Proposion 65 Warning ......................7
1.3 Requirements for the Commonwealth of
Massachuses .......................................................... 7
2.0 Specicaons ........................................................ 8
2.1 Heang Specicaons ......................................... 8
2.2 Electrical Specicaons ....................................... 8
2.3 Appliance Dimensions ......................................... 9
2.4 Safety Barrier Dimensions .................................. 10
3.0 Framing ................................................................ 11
3.1 Installaon Planning ........................................... 11
3.2 Clearance to Combusbles ................................. 12
3.3 Rough-In Vent Terminaon ................................ 13
3.4 Alcove Installaon ............................................... 14
3.5 Masonry Applicaon ........................................... 16
3.6 Outdoor Covered Gas Stove Installaon............. 17
4.0 Gas Line Connecon ............................................. 19
4.1 Gas Conversion ................................................... 19
4.2 Gas Line Installaon ............................................ 19
5.0 Terminaon Locaons .......................................... 20
5.1 Vercal Vent Terminaon ................................... 20
5.2 Minimum Terminaon Clearances ..................... 21
6.0 Venng ................................................................. 22
6.1 Approved Vent Systems ...................................... 22
6.2 Venng Requirements ........................................ 22
6.3 Vent Restricon .................................................. 22
6.4 Vent Installaon .................................................. 23
6.5 Class A Chimney/Masonry Chimney
Conversion .......................................................... 27
6.6 Co-Axial to Co-Linear Chimney Conversion ........ 28
7.0 Fireplace Setup ..................................................... 29
7.1 Safety Barrier Screen .......................................... 29
7.2 Glass Frame Assembly ........................................ 29
7.3 #LX22-500 Log Set Installaon ............................ 30
7.4 Control Board Removal and Installaon ............. 32
7.5 LX22-028MV Oponal Fan Kit
(LXL-22-MV Only) ................................................ 33
8.0 Electrical Informaon .................................................. 35
8.1 Electrical Specicaons ............................................. 35
8.2 Wiring Requirements ................................................ 35
9.0 Operang Instrucons for LXL-22-L ............................ 38
9.1 Setup Proame 2 IFC Module .................................... 39
9.2 Inialize the Control System ..................................... 39
9.3 Reset the System for Manual Operaon ................... 39
9.4 Automac Safety Turn-O ........................................ 39
9.5 Backup Baery Operaon ......................................... 39
9.6 Control System 7 Day Timeout .................................. 40
9.7 IFC Module Ignion Sequence................................... 40
9.8 Addional Diagnosc Informaon ............................ 40
9.9 Remote Control Operaon ........................................ 41
10.0 Operang Instrucons for LXL-22-MV .......................... 45
10.1 Main Burner On/O Rocker Switch Locaon ............ 46
10.1 Flame Height and Heat Output Adjustment ............. 46
10.3 7 Day Time-Out Pilot-on-Demand Installaon .......... 46
11.0 Pressure Tesng and Burner Adjustments ................. 47
11.1 Pressure Tesng (LXL-22-L) ...................................... 47
11.2 Pressure Tesng (LXL-22-MV) ................................... 48
11.3 Flame Appearance Adjustments ............................... 49
11.4 Vent Restricon Adjustments ................................... 51
12.0 Troubleshoong......................................................... 54
12.1 Electronic Ignion System (LXL-22-L) ........................ 54
12.2 Millivolt Ignion System (LXL-22-MV) ....................... 57
13.0 Maintenance .............................................................. 60
13.1 Firebox ....................................................................... 60
13.2 Fan ............................................................................. 60
13.3 Vent System .............................................................. 60
13.4 Glass Assembly .......................................................... 61
13.5 Burner and Pilot System ............................................ 62
14.0 Replacement Parts List............................................... 63
Limited Lifeme Warranty ................................................... 66
TABLE OF CONTENTS
Hussong Mfg. Co, Inc. 6 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
Hussong Mfg. Co, Inc. 7 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
1.1 Appliance Cercaon
Laboratory: PFS in Coage Grove, Wisconsin
Standards:
ANSI Z21.88-2019/CSA 2.33-2019, Vented Gas Fireplace
Heaters
CSA 2.17 2017, Gas-Fired Appliances for Use at High
Altudes
This installaon must conform with local codes, or in the
absence of local codes, with the Naonal Fuel Gas Code,
ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Instal-
laon Code, CSA B149.1.
1.2 California Proposion 65 Warning
WARNING: This product can expose you to chemicals in-
cluding Carbon Monoxide, that is an externally vented by-
product of fuel combuson, which is [are] known to the
State of California to cause birth defects or other reproduc-
ve harm. For more informaon, visit
www.P65Warnings.ca.gov.
1.3 Requirements for the Commonwealth of Mas-
sachuses
The following requirements reference various Massachuses
and naonal codes not contained in this manual.
For all sidewall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residenal purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent terminaon is less than (7) feet above
nished grade in the area of the venng, including but not
limited to decks and porches, the following requirements
shall be sased:
1.3.1 Installaon of Carbon Monoxide Detectors
At me of installaon of side wall horizontally vented gas
fueled equipment, the installing plumber or gas-er shall
observe that a hard wired carbon monoxide detector with an
alarm and baery back-up is installed on the oor level
where the gas equipment is to be installed. In addion, the
installing plumber or gas-er shall observe that a baery
operated or hard wired carbon monoxide detector is in-
stalled on each addional level of the dwelling, building or
structure served by the side wall horizontal vented gas
fueled equipment. It shall be the responsibility of the proper-
ty owner to secure the services of qualied licensed profes-
sionals for the installaon of hard wired carbon monoxide
detectors.
In the event that the side wall horizontally vented gas fueled
equipment is installed in a crawl space or ac, the hard
wired carbon monoxide detector with alarm and baery
back-up may be installed on the next adjacent oor level. In
the event that the requirements of this subdivision can not
be met at the me of compleon of installaon, the owner
shall have a period of thirty (30) days to comply with the
above requirements; provided, however, that during said
thirty (30) day period, a baery operated carbon monoxide
detector with an alarm shall be installed.
1.3.2 Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance with
the above provisions shall comply with NFPA 720 and be ANSI/
UL 2034 listed and IAS cered.
1.3.3 Signage
A metal or plasc idencaon plate shall be permanently
mounted to the exterior of the building at a minimum of eight
(8) feet above grade directly in line with the exhaust vent termi-
nal for the horizontally vented gas fueled heang appliance or
equipment. The sign shall read, in print no less the one-half inch
(½) in size, GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS”.
1.3.4 Inspecon
The state or local gas inspector of the side wall horizontally vent-
ed gas fueled equipment shall not approve the installaon un-
less, upon inspecon, the inspector observes carbon monoxide
detectors and signage installed in accordance with the provisions
of 248 CMR 5.08 (2) (a) 1 through 4.
1.3.5 Exempons
The following equipment is exempt from 248 CMR 5.08 (2) (a) 1
through 4: The equipment listed in Chapter 10 entled
Equipment Not Required To Be Ventedin the most current
edion of NFPA 54 as adopted by the Board; and Product Ap-
proved side wall horizontally vented gas fueled equipment in-
stalled in a room or structure separate from the dwelling, build-
ing or structure used in whole or in part for residenal purposes.
1.3.6 Manufacturer Requirements
1.3.6.1 Gas Equipment Venng System Provided
When the manufacturer of Product Approved side wall horizon-
tally vented gas equipment provides a venng system design or
venng system components with the equipment, the instruc-
ons provided by the manufacturer for installaon of the equip-
ment and the venng system shall include:
Detailed instrucons for the installaon of the venng sys-
tem design or the venng system components; and
A complete parts list for the venng system design or
venng system.
1.3.6.2 Gas Equipment Venng System NOT Provided
When the manufacturer of Product Approved side wall horizon-
tally vented gas equipment does not provide the parts for
venng the ue gases, but idenes special venng systems”,
the following requirements shall be sased by the manufactur-
er:
The referenced special venng systemsinstrucons shall
be included with the appliance or equipment installaon
instrucons and;
The special venng systemsshall be Product Approved by
the Board, and the instrucons for that system shall include
a parts list and detailed installaon instrucons.
A copy of all installaon instrucons for all Product Approved
side wall horizontally vented gas fueled equipment, all venng
instrucons, all parts lists for venng instrucons, and/or all
venng design instrucons shall remain with the appliance or
equipment at the compleon of the installaon.
1.0 Introducon
Hussong Mfg. Co, Inc. 8 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
2.0 Specicaons
2.1 Heang Specicaons
2.1.1 Altude Adjustment
This appliance may be installed at higher altudes. Please refer to Naonal Fuel Gas Code ANSI Z223.1/NFPA 54, CSA-B149.1 Natu-
ral Gas and Propane Installaon Code, local authories, or codes having jurisdicon in your area regarding derate guidelines.
2.1.1.1 US Installaons
Refer to the American Gas Associaon guidelines for the gas designed appliances derang method. For elevaons above
2,000’ (610m), input rangs are to be reduced by 4% for each 1,000’ (305m) above sea level.
2.1.1.2 Canadian Installaons
When the appliance is installed at elevaons above 4,500’ (1,372m), the cered high-altude rang shall be reduced at the rate of
4% for each addional 1,000’ (305m).
2.2 Electrical Specicaons
The juncon box in this appliance requires 120VAC, 60Hz, and 6 Amps.
Verify the household breaker is shut o prior to working on any electrical lines.
LXL-22-L
The AC power supply to this appliance must be hot at all mes and shall not have a switch installed in it.
LXL-22-MV
Electrical specicaons ONLY apply to when the oponal fan kit (#LX22-028MV) is used.
LXL-22-L LXL-22-MV
Natural Gas Propane Natural Gas Propane
Maximum Input Rang 40,000 Btu/h
(11.72 kW)
40,000 Btu/h
(11.72 kW)
40,000 Btu/h
(11.72 kW)
40,000 Btu/h
(11.72 kW)
Minimum Input Rang 27,500 Btu/h
(8.06 kW)
29,500 Btu/h
(8.65 kW)
27,500 Btu/h
(8.06 kW)
29,500 Btu/h
(8.65 kW)
Orice Size (DMS) 3.20mm 1.90mm 3.20mm 1.90mm
Minimum Inlet Pressure 5”WC (1.25kPa)
7” WC (1.74 kPa)
recommended
11”WC (2.74 kPa) 5”WC (1.25kPa)
7” WC (1.74 kPa) rec-
ommended
11”WC (2.74 kPa)
Maximum Inlet Pressure 10”WC (2.49 kPa) 13”WC (3.24 kPa) 10”WC (2.49 kPa) 13”WC (3.24 kPa)
Manifold Pressure (Low) 1.6” WC (0.40 kPa) 6.4” WC (1.59 kPa) 1.6” WC (0.40 kPa) 6.4” WC (1.59 kPa)
Manifold Pressure (High) 3.5” WC (0.875 kPa) 10” WC (2.49 kPa) 3.5” WC (0.875 kPa) 10” WC (2.49 kPa)
Venturi Opening Sengs 1/4” (6.35mm) Open 5/8” (15.88mm) Open 1/4” (6.35mm) Open 5/8” (15.88mm) Open
Hussong Mfg. Co, Inc. 9 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
2.3 Appliance Dimensions
Figure 2.1, Appliance dimensions
Hussong Mfg. Co, Inc. 10 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
2.4 Safety Barrier Dimensions
WARNING: A barrier designed to reduce the risk of
burns from the hot viewing glass is provided with this
appliance and shall be installed for the protecon of
children and other at-risk individuals.
If the barrier becomes damaged, the barrier shall be re-
placed with Hussong Mfg.s barriers for this appliance.
Please refer to Secon 7.1 Safety Barrier Installaon for
installaon and removal of safety barriers.
Figure 2.2, Safety barrier dimensions
Hussong Mfg. Co, Inc. 11 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
3.0 Framing
3.1 Installaon Planning
Alcove Installaon allows the gas stove to be located within a recessed secon of a room. Refer to secon 3.4, ALCOVE IN-
STALLATION for more informaon.
Masonry Applicaon allows the gas stove to sit inside an exisng masonry replace. Refer to secon 3.5, MASONRY APPLI-
CATION on for more informaon.
If planning to convert to propane, it is easier to complete the gas conversion before installing the gas stove. For LXL-22-L see
the #LCK-LX22L-S30 conversion kit manual for complete conversion instrucons. For LXL-22-MV See the #OCK-S190A con-
version kit manual for complete conversion instrucons. Refer to secon 7.4, CONTROL BOARD REMOVAL AND INSTALLA-
TION for access to the burner and pilot system before and aer installaon.
3.1.1 Appliance Placement Consideraons
WARNING: Due to high temperatures, the appliance should be located out of trac and away from furniture and draperies.
This gas stove must be installed on a level surface capable of supporng the gas stove and venng. Determine your vent
requirements before framing your appliance
This appliance may be installed in a bedroom.
Please be aware of the large amount of heat this gas stove will produce when determining a locaon.
When installing the stove ensure there is adequate space between the back the of stove and the adjacent wall for access to
remove the fan kit for maintenance. See Secon 13.2 for fan maintenance.
3.2 Floor Support and Protecon
The appliance must be placed directly on a wood or non- combusble surface (not linoleum or carpet) extending the enre
depth and width of the gas stove.
If this appliance is to be installed directly on carpeng, le, or other combusble material other than wood ooring, this
appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
If the appliance is to be installed above oor level, a solid, connuous plaorm must be constructed below the appliance.
3.3 Seng the Appliance
This secon outlines informaon on seng the appliance in the framed opening and starng the installaon process. .
General Procedure
 Find the desired locaon of the stove.
 Determine the vent path and the type of terminaon (vercal or horizontal).
 See Secon 5.0 and 6.0 for venng requirements. If the appliance will be installed as a horizontal vent terminaon see Sec-
on 3.4 for framing informaon.
 Determine the locaon of electrical (if needed) and gas line.
 Complete any nishing material below or around the appliance locaon.
 Place and secure the appliance.
 Install vent system.
Hussong Mfg. Co, Inc. 12 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
3.4 Clearances to Combusbles
See Figure 3.1 below for minimum clearances for typical installaon opons.
Refer to Figure 3.3 for rough-in clearances.
Figure 3.1, Typical Installaon Opons
Table 3.1, Minimum Appliance Clearances to Combusble Materials
From appliance top to sidewall 3” 76mm
From appliance top to back wall 3” 76mm
From appliance top corner to wall 1-1/2” 38mm
Floor to ceiling 68-1/4” 1734mm
From appliance top to ceiling 36-1/4” 920mm
From top of horizontal pipe surface to ceiling 2-1/4” 57mm
Hussong Mfg. Co, Inc. 13 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
3.3 Rough-In Vent Terminaon
This is a cold air transfer area. The gas stove rough-in must
comply with all clearances as outlined in this manual, and be
constructed in compliance with local building codes. Outside
walls should be insulated to prevent cold air from entering
room.
Exterior vent terminaon locaon must be in compliance with
secon 5.2, MINIMUM TERMINATION CLEARANCES. DO NOT
RECESS THE VENT CAP INTO WALL OR SIDING.
3.3.1 Clearances
A minimum of 1” (25mm) clearance on all sides of the
vercal vent pipe must be maintained.
A minimum of 1” (25mm) clearance from the top surface
on the horizontal pipe must be maintained.
A minimum of 1” (25mm) clearance on the sides and
boom surfaces on the horizontal pipe must be main-
tained.
A minimum of 2-1/4” (57mm) clearance from the top of
the horizontal pipe to the ceiling is required. The horizon-
tal pipe aer the wall pass-through must maintain a
1” (25mm) clearance to combusbles on all surfaces of
the pipe.
3.3.2 Vercal Terminaons
Follow vent pipe manufacturers installaon instrucons for
vercal terminaons.
Ac insulaon shields may be insulated using unfaced
insulaon products listed as non-combusble per ASTM E
136.
3.3.3 Horizontal Terminaons
IMPORTANT: Horizontal vent secons require 1/4” (6mm) rise
for every 12” (305mm) of travel.
Wall thimble products that comply with the required
1” (25mm) clearances to combusbles must be installed
for all horizontal vent runs that pass through interior or
exterior walls. These wall thimble products may be insu-
lated using unfaced insulaon products listed as noncom-
busble per ASTM E 136.
Elbows listed with approved vent systems for this appli-
ance vary in vercal length. Please consult the vent man-
ufacturers instrucons to determine the elbow dimen-
sion used for installaon. Adjust the wall pass-through
rough opening dimensions to maintain clearance require-
ments.
Figure 3.2, Rough-in Dimensions for Minimum Horizontal
Venng
3.3.3.1 Wall Pass Through Informaon and Framing
1. Measure from oor level of the gas stove to the center of
where the vent pipe will penetrate the wall. The dimensions in
Figure 3.2 is used with a Simpson DuraVent elbow.
2. Cut and frame an opening in the wall to allow the vent system
to run level through the wall pass-through.
3. Follow the vent pipe manufacturers installaon instrucons
for vent installaon.
Rigid pipe dimensions in Figure 3.2 reect Simpson DuraVent
4” x 6-5/8” coaxial pipe. Other manufacturers product dimen-
sions may vary.
Hussong Mfg. Co, Inc. 14 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
3.4 Alcove Installaon
Shown in Figure 3.3 is a top-down view of a tradional alcove installaon.
The alcove installaon may have a front wall, as shown in Figure 3.4, to visually hide the vent pipe and vent elbow, as long as
required clearances are met. The 8” mantel shown in Figure 3.4 is the maximum mantel projecon allowed in any alcove installa-
on.
Minimum clearances MUST be maintained in order to provide adequate air circulaon around the appliance and venng within
the alcove.
Figure 3.3, Tradional Alcove Framing
Hussong Mfg. Co, Inc. 15 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
Figure 3.4, Alcove Front Wall Framing
Hussong Mfg. Co, Inc. 16 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
3.5 Masonry Applicaon
Figure 3.5 shown below is a masonry applicaon where the gas stove sits inside of a masonry replace.
As referenced in Figure 3.5, the 3/4” (19mm) mantel trim can start at 40-1/2” (1029mm) above the oor with a 6” (152mm)
mantel starng at 44” (1118mm) above the oor.
As referenced in FIGURE 3.5, clearances to combusbles sided in the front (such as a mantel leg or a sidewall) is 3” (76mm)
from the masonry replace opening with an unlimited projecon.
The mantel project shown is the minimum mantel allowed. You are able to increase the mantel projecon by 1” (25mm) out
by going 1” (25mm) up. An example of this would be if you wanted a 9” (229mm) mantel you would need to go another
3” (76mm) higher than the minimum height shown. The 9” (229mm) mantel would be 43-1/2” (1105mm) o the oor.
Figure 3.5, Masonry Applicaon
Hussong Mfg. Co, Inc. 17 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
3.6 Outdoor Covered Gas Stove Installaon
An outdoor covered gas stove installaon allows a gas stove to be installed in an outdoor covered area, where the appliance is
protected from direct precipitaon.
Follow the instrucons and illustraons in this secon for installaon procedures.
3.6.1 Safety Screen Barriers
Hussong Mfg. highly recommends to use black painted safety barriers in outdoor installaons. Other screen barriers that incor-
porate a plated or pana nish are highly suscepble to oxidaon and discoloraon.
3.6.2 Requirements
Calculate your roof overhang dimensions by following Figure 3.6 below.
The connuous insulated building envelope and weatherproof membrane are not to be interrupted by gas stove installa-
on. See Figure 3.7.
Gas stove operaon is approved from 40°F to 110°F.
All wiring connecons shall be in accordance with outdoor requirements of NECA NFPA 70.
All clearances and requirements in your appliance manual must be adhered to.
Figure 3.6, Outdoor Covered Gas Stove Install
Hussong Mfg. Co, Inc. 18 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
Figure 3.7, Outdoor Covered Gas Stove Install
Hussong Mfg. Co, Inc. 19 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
4.0 Gas Line Connecon
4.1 Gas Conversion
The gas conversion kit is sold separately.
ATTENTION: The conversion shall be carried out in accordance with the requirements of the provincial authories having juris-
dicon and in accordance with the requirements of the ANSI Z223.1 installaon code.
This replace is manufactured for use with natural gas. Follow the instrucons included with the conversion kit if converng to
propane.
4.2 Gas Line Installaon
CAUTION: Installaon of the gas line must only be done by a qualied person in accordance with local building codes, if any. If
not, follow ANSI Z223.1. Commonwealth of Massachuses installaons must be done by a licensed plumber or gas er.
NOTE: The appliance and its individual shuto valve must be disconnected from the gas supply piping system during any pres-
sure tesng of that system at pressures in excess of ½ psi (3.5 kPa). For test pressures equal to or less than ½ psi (3.5 kPa), the
appliance must be isolated from the gas supply piping system by closing its individual manual shut-o valve.
A listed (and Commonwealth of Massachuses approved) 1/2” (13mm) tee handle manual shut-o valve and exible gas
connector are to be connected to the 1/2” (13 mm) control valve inlet. If substung for these components, please consult
local codes for compliance.
This replace is equipped with a 3/8” (10mm) x 18” (457mm) long exible gas connector and manual shut-o valve.
Run gas line into replace. The gas line should be run to the point of connecon where the shut-o valve and exible gas
line will connect. See Figure 2.1, LXL-22-L DIMENSIONS.
Do not run gas line in a manner that would obstruct the oponal fan operaon.
For high altude installaons, consult the local gas distributor or the authority having jurisdicon for proper rang meth-
ods.
Table 4.1, Inlet Pressure Requirements - LXL-22-L (IPI)
Gas Pressure Natural Gas Propane
Minimum Inlet Pressure 5” WC (1.25 kPa)
7” WC (1.74 kPa)
recommended
11” WC (2.74 kPa)
Maximum Inlet Pressure 10” WC (2.49 kPa) 13” WC (3.24 kPa)
Table 4.2, Inlet Pressure Requirements - LXL-22-L (Millivolt)
Gas Pressure Natural Gas Propane
Minimum Inlet Pressure 5” WC (1.25 kPa)
7” WC (1.74 kPa)
recommended
11” WC (2.74 kPa)
Maximum Inlet Pressure 10” WC (2.49 kPa) 13” WC (3.24 kPa)
Hussong Mfg. Co, Inc. 20 Rev. 3 - November 2023
LXL-22-L Report No. 21-739 Starng Serial Number: 23 01501 51
5.0 Terminaon Locaons
5.1 Vercal Vent Terminaon
WARNING: This gas appliance must not be connected to a chimney ue serving a separate solid-fuel burning appliance.
Refer to Figure 5.1 for vercal vent terminaon clearances.
Refer to Figure 5.2 for clearance between two vercal vent terminaons.
Refer to Figure 5.3 for clearance between a masonry applicaon (shown with co-axial to co-linear venng)
Figure 5.3, 3”x3Vent cap clearance
Minimum height (H) from roof
Roof Pitch Feet Meters
Flat to 6/12 1.0 0.30
1.25 0.38
1.5 0.46
2.0 0.61
2.5 0.76
3.25 0.99
4.0 1.22
5.0 1.52
6.0 1.83
7.0 2.13
7.5 2.27
8.0 2.44
Figure 5.2, Clearance between two vercal terminaons
Figure 5.1, Co-axial vercal terminaon clearances
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67