ASRock Rack EC262D4U-2L2T User manual

Category
Server/workstation motherboards
Type
User manual
User Manual
EC262D4U-2L2T
EC266D4U-2L2T
Version 1.0
Published June 2023
Copyrightยฉ2023 ASRock Rack INC. All rights reserved.
Version 1.0
Published June 2023
Copyrightยฉ2023 ASRock Rack INC. All rights reserved.
Copyright Notice:
No part of this documentation may be reproduced, transcribed, transmitted, or translated
in any language, in any form or by any means, except duplication of documentation by the
purchaser for backup purpose, without written consent of ASRock Rack Inc.
Products and corporate names appearing in this documentation may or may not be
registered trademarks or copyrights of their respective companies, and are used only for
identi๎€Ÿcation or explanation and to the ownersโ€™ bene๎€Ÿt, without intent to infringe.
Disclaimer:
Specifications and information contained in this documentation are furnished for
informational use only and subject to change wit hout notice, and should not be
constructed as a commitment by ASRock Rack. ASRock Rack assumes no responsibility
for any errors or omissions that may appear in this documentation.
With respect to the contents of this documentation, ASRock Rack does not provide
warranty of any kind, either expressed or implied, including but not limited to the implied
warranties or conditions of merchantability or ๎€Ÿtness for a particular purpose.
In no event shall ASRock Rack, its directors, o๎€žcers, employees, or agents be liable for
any indirect, special, incidental, or consequential damages (including damages for loss of
pro๎€Ÿts, loss of business, loss of data, interruption of business and the like), even if ASRock
Rack has been advised of the possibility of such damages arising from any defect or error
in the documentation or product.
๎€is device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
๎€is equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. ๎€ese limits are designed to provide reason-
able protection against harmful interference in a residential installation. ๎€is equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in ac-
cordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment o๎€œ and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit di๎€œerent from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
INTEL END USER SOFTWARE LICENSE AGREEMENT
IMPORTANT - READ BEFORE COPYING, INSTALLING OR USING.
LICENSE. Licensee has a license under Intelโ€™s copyrights to reproduce Intelโ€™s Software
only in its unmodified and binary form, (with the accompanying documentation, the
โ€œSo๎€›wareโ€) for Licenseeโ€™s personal use only, and not commercial use, in connection with
Intel-based products for which the So๎€›ware has been provided, subject to the following
conditions:
(a) Licensee may not disclose, distribute or transfer any part of the So๎€›ware, and You agree
to prevent unauthorized copying of the So๎€›ware.
(b) Licensee may not reverse engineer, decompile, or disassemble the So๎€›ware.
(c) Licensee may not sublicense the So๎€›ware.
(d) ๎€e So๎€›ware may contain the so๎€›ware and other intellectual property of third party
suppliers, some of which may be identi๎€Ÿed in, and licensed in accordance with, an enclosed
license.txt ๎€Ÿle or other text or ๎€Ÿle.
(e) Intel has no obligation to provide any support, technical assistance or updates for the
So๎€›ware.
OWNERSHIP OF SOFTWARE AND COPYRIGHTS. Title to all copies of the So๎€›ware
remains with Intel or its licensors or suppliers. ๎€e So๎€›ware is copyrighted and protected
by the laws of the United States and other countries, and international treaty provisions.
Licensee may not remove any copyright notices from the So๎€›ware. Except as otherwise ex-
pressly provided above, Intel grants no express or implied right under Intel patents, copy-
rights, trademarks, or other intellectual property rights. Transfer of the license terminates
Licenseeโ€™s right to use the So๎€›ware.
DISCLAIMER OF WARRANTY. ๎€e So๎€›ware is provided โ€œAS ISโ€ without warranty of
any kind, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION,
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PUR-
POSE.
LIMITATION OF LIABILITY. NEITHER INTEL NOR ITS LICENSORS OR SUPPLIERS
WILL BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF USE, INTERRUPTION OF
BUSINESS, OR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAG-
ES OF ANY KIND WHETHER UNDER THIS AGREEMENT OR OTHERWISE, EVEN
IF INTEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
LICENSE TO USE COMMENTS AND SUGGESTIONS. ๎€is Agreement does NOT ob-
ligate Licensee to provide Intel with comments or suggestions regarding the Software.
However, if Licensee provides Intel with comments or suggestions for the modi๎€Ÿcation,
correction, improvement or enhancement of (a) the So๎€›ware or (b) Intel products or pro-
cesses that work with the So๎€›ware, Licensee grants to Intel a non-exclusive, worldwide,
perpetual, irrevocable, transferable, royalty-free license, with the right to sublicense, under
Licenseeโ€™s intellectual property rights, to incorporate or otherwise utilize those comments
and suggestions.
TERMINATION OF THIS LICENSE. Intel or the sublicensor may terminate this license
at any time if Licensee is in breach of any of its terms or conditions. Upon termination,
Licensee will immediately destroy or return to Intel all copies of the So๎€›ware.
THIRD PARTY BENEFICIARY. Intel is an intended bene๎€Ÿciary of the End User License
Agreement and has the right to enforce all of its terms.
U.S. GOVERNMENT RESTRICTED RIGHTS. The Software is a commercial item (as
de๎€Ÿned in 48 C.F.R. 2.101) consisting of commercial computer so๎€›ware and commercial
computer so๎€›ware documentation (as those terms are used in 48 C.F.R. 12.212), consistent
with 48 C.F.R. 12.212 and 48 C.F.R 227.7202-1 through 227.7202-4. You will not provide
the So๎€›ware to the U.S. Government. Contractor or Manufacturer is Intel Corporation,
2200 Mission College Blvd., Santa Clara, CA 95054.
EXPORT LAWS. Licensee agrees that neither Licensee nor Licenseeโ€™s subsidiaries will
export/re-export the Software, directly or indirectly, to any country for which the U.S.
Department of Commerce or any other agency or department of the U.S. Government or
the foreign government from where it is shipping requires an export license, or other gov-
ernmental approval, without ๎€Ÿrst obtaining any such required license or approval. In the
event the So๎€›ware is exported from the U.S.A. or re-exported from a foreign destination
by Licensee, Licensee will ensure that the distribution and export/re-export or import of
the So๎€›ware complies with all laws, regulations, orders, or other restrictions of the U.S.
Export Administration Regulations and the appropriate foreign government.
APPLICABLE LAWS. ๎€is Agreement and any dispute arising out of or relating to it will
be governed by the laws of the U.S.A. and Delaware, without regard to conflict of laws
principles. The Parties to this Agreement exclude the application of the United Nations
Convention on Contracts for the International Sale of Goods (1980). ๎€e state and federal
courts sitting in Delaware, U.S.A. will have exclusive jurisdiction over any dispute arising
out of or relating to this Agreement. ๎€e Parties consent to personal jurisdiction and venue
in those courts. A Party that obtains a judgment against the other Party in the courts iden-
ti๎€Ÿed in this section may enforce that judgment in any court that has jurisdiction over the
Parties.
Licenseeโ€™s speci๎€Ÿc rights may vary from country to country.
CALIFORNIA, USA ONLY
๎€e Lithium battery adopted on this motherboard contains Perchlorate, a toxic substance
controlled in Perchlorate Best Management Practices (BMP) regulations passed by the
California Legislature. When you discard the Lithium battery in California, USA, please
follow the related regulations in advance.
โ€œPerchlorate Material-special handling may apply, see www.dtsc.ca.gov/hazardouswaste/
perchlorateโ€
AUSTRALIA ONLY
Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and compensation for
any other reasonably foreseeable loss or damage caused by our goods. You are also entitled
to have the goods repaired or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure. If you require assistance please call ASRock
Rack Tel : +886-2-55599600 ext.123 (Standard International call charges apply)
ASRock Rack INC. hereby declares that this device is in compliance with the essential re-
quirements and other relevant provisions of related UKCA Directives. Full text of UKCA
declaration of conformity is available at: http://www.asrockrack.com
ASRock Rack INC. hereby declares that this device is in compliance with the essential re-
quirements and other relevant provisions of related Directives. Full text of EU declaration
of conformity is available at: http://www.asrockrack.com
ASRock Rack follows the green design concept to design and manufacture our products,
and makes sure that each stage of the product life cycle of ASRock Rack product is in line
with global environmental regulations. In addition, ASRock Rack disclose the relevant in-
formation based on regulation requirements.
Please refer to https://www.asrockrack.com/general/about.asp?cat=Responsibility for in-
formation disclosure based on regulation requirements ASRock Rack is complied with:
DO NOT throw the motherboard in municipal waste. ๎€is product has been
designed to enable proper reuse of parts and recycling. This symbol of the
crossed out wheeled bin indicates that the product (electrical and electronic
equipment) should not be placed in municipal waste. Check local regulations
for disposal of electronic products.
Contents
Chapter 1 Introduction 1
1.1 Package Contents 1
1.2 Speci๎€Ÿcations 2
1.3 Unique Features 6
1.4 Motherboard Layout 7
1.5 Onboard LED Indicators 10
1.6 I/O Panel 11
1.7 Block Diagram 13
Chapter 2 Installation 14
2.1 Screw Holes 14
2.2 Pre-installation Precautions 14
2.3 Installing the CPU 15
2.4 Installing the CPU Fan and Heatsink 17
2.5 Installing Memory Modules (DIMM) 18
2.6 Expansion Slots (PCI Express Slots) 20
2.7 Jumper Setup 21
2.8 Onboard Headers and Connectors 22
2.9 Dr. Debug 28
2.10 Unit Identi๎€Ÿcation purpose LED/Switch 34
2.11 Dual LAN and Teaming Operation Guide 35
2.12 M.2 SSD Module Installation Guide 36
Chapter 3 UEFI Setup Utility 38
3.1 Introduction 38
3.1.1 UEFI Menu Bar 38
3.1.2 Navigation Keys 39
3.2 Main Screen 40
3.2.1 Motherboard Information 41
3.2.2 Processor Information 41
3.2.3 Memory Information 42
3.3 Advanced Screen 43
3.3.1 CPU Con๎€Ÿguration 44
3.3.2 DRAM Con๎€Ÿguration 47
3.3.3 Chipset Con๎€Ÿguration 48
3.3.4 Storage Con๎€Ÿguration 50
3.3.5 NVME Con๎€Ÿguration 51
3.3.6 ACPI Con๎€Ÿguration 52
3.3.7 USB Con๎€Ÿguration 53
3.3.8 Super IO Con๎€Ÿguration 54
3.3.9 Serial Port Console Redirection 55
3.3.10 H/W Monitor 58
3.3.11 Network Stack Con๎€Ÿguration 59
3.3.12 Intel SPS Con๎€Ÿguration 61
3.3.13 Driver Health 62
3.3.14 Tls Auth Con๎€Ÿguration 63
3.3.15 Instant Flash 64
3.4 Server Mgmt 65
3.4.1 BMC Network Con๎€Ÿguration 67
3.4.2 System Event Log 69
3.4.3 BMC Tools 70
3.5 Event Logs 71
3.6 Security Screen 72
3.6.1 Key Management 73
3.7 Boot Screen 77
3.8 Exit Screen 79
Chapter 4 Software Support 80
4.1 Download and Install Operating System 80
4.2 Download and Install Software Drivers 80
4.3 Contact Information 80
Chapter 5 Troubleshooting 81
5.1 Troubleshooting Procedures 81
5.2 Technical Support Procedures 83
5.3 Returning Merchandise for Service 83
EC262D4U-2L2T
EC266D4U-2L2T
PB 1
English
Chapter 1 Introduction
๎€ank you for purchasing ASRock Rack EC262D4U-2L2T/EC266D4U-2L2T motherboard, a
reliable motherboard produced under ASRock Rackโ€™s consistently stringent quality control. It
delivers excellent performance with robust design conforming to ASRock Rackโ€™s commitment
to quality and endurance.
In this manual, chapter 1 and 2 contains introduction of the motherboard and step-by-step
guide to the hardware installation. Chapter 3 and 4 contains the con๎€Ÿguration guide to BIOS
setup and information of the So๎€›ware Support.
1.1 Package Contents
โ€ข ASRock Rack EC262D4U-2L2T/EC266D4U-2L2T Motherboard
(Micro-ATX Form Factor: 9.6in x 9.6in, 24.4cm x24.4cm)
โ€ข Quick Installation Guide
โ€ข 1 x SATA3 Cable (60cm)
โ€ข 1 x Oculink to 4 SATA Cable (60cm)
โ€ข 1 x I/O Shield
โ€ข 1 x Screw for M.2 Socket
If any items are missing or appear damaged, contact the authorized dealer.
Because the motherboard speci๎€Ÿcations and the BIOS so๎€žware might be updated, the con-
tent of this manual will be subject to change without notice. In case any modi๎€Ÿcations of
this manual occur, the updated version will be available on ASRock Rack website without
further notice. Find the latest memory and CPU support lists on ASRock Rack website as
well. ASRock Rackโ€™s Website: www.ASRockRack.com
About this motherboard technical support, please visit the website for speci๎€Ÿc information
http://www.asrockrack.com/support/
2 3
English
1.2 Speci๎€Ÿcations
EC262D4U-2L2T / EC266D4U-2L2T
MB Physical Status
Form Factor Micro-ATX
Dimension 9.6'' x 9.6'' (244mm x 244mm)
Processor System
CPU Supports Intelยฎ Xeonยฎ E-2400 series processors
Socket Single Socket V1 (LGA1700)
๎€ermal Design
Power (TDP)
95W
Chipset EC266D4U-2L2T: Intelยฎ C266
EC262D4U-2L2T: Intelยฎ C262
System Memory
Supported
DIMM Quantity
4 DIMM slots (2DPC)
Supported Type Supports DDR5 288-pin ECC UDIMM
Max. Capacity
per DIMM
32GB
Max. Frequency 4400MT/s (2SPC - 1DIMM) / 4000MT/s (2SPC - 2DIMM 1R)
/ 3600MT/s (2SPC - 2DIMM 2R)
Voltage 1.1V
Note memory support is to be validated
PCIe Expansion Slots (SLOT7 close to CPU)
SLOT7 PCIe4.0 x4* [CPU]
SLOT6 PCIe5.0 x16 [CPU]
SLOT5 PCIe4.0 x4** [PCH]
SLOT4 PCIe4.0 x1 [PCH]
Note *SLOT7 share lanes with OCuLink4. OCuLink4 will disable when SLOT7 is
populated
**M.2 share lanes with SLOT5, M.2 support possible by depopulating SLOT5
and other BOM change
Other PCIe Expansion Connectors
M.2 1 M-key (PCIe4.0x4)**; support 2280/2260/2242/2230 form
factor [PCH]
OCuLink EC262D4U-2L2T:
1 OCuLink (PCIe4.0 x4)* [CPU]
1 OCuLink (PCIe4.0 x4 or 4 SATA 6Gb/s) [PCH]
EC266D4U-2L2T:
1 OCuLink (PCIe4.0 x4)* [CPU]
1 OCuLink (PCIe4.0 x4 or 4 SATA 6Gb/s) [PCH]
2 OCuLink (PCIe4.0 x4) [PCH]
EC262D4U-2L2T
EC266D4U-2L2T
2 3
English
Note *OCulink4 shares lanes with SLOT7 and will be disabled when SLOT7 is
populated
**M.2 share lanes with SLOT5, M.2 support possible by depopulating SLOT5
and other BOM change
SATA/SAS Storage
PCH Built-in
Storage
Intelยฎ C266/C262 (8 SATA 6Gb/s; RAID 0/1/5/10):
4 SATA 7-pin, 1 OCuLink
Ethernet
Additional
Ethernet
Controller
2 RJ45 (10GbE) by Intelยฎ X710
2 RJ45 (1GbE) by Intelยฎ i210
USB
Controller/Hub Intelยฎ C266 / Intelยฎ C262
Connectors/
Headers
External:
2 Type-A (USB3.2 Gen1)
Internal:
1 header (19-pin, 2 USB3.2 Gen1)
1 header (9-pin, 2 USB2.0)
1 V/T USB2.0 Connector
Graphics
Controller ASPEED AST2600:
1 DB15 (VGA)
Security
TPM 1 (13-pin, SPI)
Rear I/O
UID Button/
LED
1 UID button w/ LED
Video Output 1 DB15 (VGA)
Serial Port 1 DB9 (COM)
USB 2 Type A (USB3.2 Gen1)
RJ45 2 RJ45(10GbE), 2 RJ45(1GbE), 1 dedicated IPMI
Hardware Monitor
Temperature CPU, MB, Card side, VR, M.2, X710, TR1 Temperature
sensing
Fan Fan Tachometer
CPU Quiet Fan (Allow Chassis Fan Speed Auto-Adjust by
CPU Temperature)Fan Multi-Speed Control
Voltage 3VSB, 5VSB, CPU_VCORE, VCCIN_AUX,VDD2, 1.05V_
PCH, 0V82SB_PCH, VCCGT, 1V8SB, VCCSA, BAT, 3V, 5V,
12V
Server Management
BMC Controller ASPEED AST2600: iKVM, vMedia support
IPMI Dedicated
GLAN
1 RJ45 Dedicated IPMI LAN port by Realtek RTL8211F
4 5
English
System BIOS
Type AMI 256Mb SPI Flash ROM
Features Plug and Play, ACPI 6.4 and above compliance wake up
events, SMBIOS 2.8 and above, ASRock Rack Instant Flash
Internal Connectors/Headers
PSU Connector 1 (24-pin, ATX main power), 1 (8-pin, ATX 12V)
Auxiliary Panel
Header
1 (18-pin): chassis intrusion, system fault LED, LAN1/LAN2
activity LED, locate, SMBus
System Panel
Header
1 (9-pin): power switch, reset switch, system power LED,
HDD activity LED
LAN3/LAN4
LED Header
1
NMI Button 1
VGA Header 1
Speaker Header 1 (4-pin)
Buzzer 1
Fan Header 7 (4-pin)
๎€ermal Sensor
Header
1
TPM Header 1 (13-pin, SPI)
SGPIO Header 1
SMbus Header 1
PMbus Header 1
IPMB Header 1
Clear CMOS 1 (contact pads)
LED Indicators
Standby Power
LED
1 (5VSB)
80 Debug Port
LED
1
Fan Fail LED 7
BMC Heartbeat
LED
1
Support OS
OS Microso๎€›ยฎ Windowsยฎ
- Server 2022 (64bit)
Linuxยฎ
- Red Hat Enterprise Linux Server 8.5 (64bit) / 9.2 (64bit)
- SUSE Enterprise Linux Server 15 SP3 (64bit) / 15 SP5 (64bit)
- Ubuntu 21.04 (64 bit) / 22.04.2 (64bit)
*Please refer to the website for the latest OS support list.
EC262D4U-2L2T
EC266D4U-2L2T
4 5
English
๎€is motherboard supports Wake from on Board LAN. To use this function, please make
sure that the โ€œWake on Magic Packet from power o๎€œ stateโ€ is enabled in Device Manager
> Intelยฎ Ethernet Connection > Power Management. And the โ€œPCI Devices Power Onโ€ is
enabled in UEFI SETUP UTILITY > Advanced > ACPI Con๎€Ÿguration. A๎€žer that, onboard
LAN1&2 can wake up S5 under OS.
If installing Intelยฎ LAN utility or Marvell SATA utility, this motherboard may fail Win-
dowsยฎ Hardware Quality Lab (WHQL) certi๎€Ÿcation tests. If installing the drivers only, it
will pass the WHQL tests.
NOTE: Please refer to the website for the latest speci๎€Ÿcations.
Enviroment
Operating
Temperature
10 - 35ยฐC (50 - 95 degF)
Non-operating
Temperature
-40 - 70ยฐC (-40 - 158degF)
6 7
English
1.3 Unique Features
ASRock Rack Instant Flash is a BIOS ๎€šash utility embedded in Flash ROM. ๎€is convenient
BIOS update tool allows user to update system BIOS without entering operating systems
๎€Ÿrst like MS-DOS or Windowsยฎ. With this utility, press the <F6> key during the POST or the
<F2> key to enter into the BIOS setup menu to access ASRock Rack Instant Flash. Just launch
this tool and save the new BIOS ๎€Ÿle to the USB ๎€šash drive, ๎€šoppy disk or hard drive, then
update the BIOS only in a few clicks without preparing an additional ๎€šoppy diskette or other
complicated ๎€šash utility. Please be noted that the USB ๎€šash drive or hard drive must use
FAT32/16/12 ๎€Ÿle system.
EC262D4U-2L2T
EC266D4U-2L2T
6 7
English
1.4 Motherboard Layout
3 4 5 62
17 8
9
10
11
12
13
14
16
15
17
18
19
20
21
22
23
2425262728293031
32
33
3435
36
38
39
40
42
41
37
43
24.4 cm (9.6 in)
24.4 cm (9.6 in)
UID1
T:USB3_2
B:USB3_1
IPMI_LAN
USB 3.2
Gen1 Ports
LAN4
LAN3
VGA
COM1
LAN2
LAN1
FRNT_VGA1
ATX12V1ATX12V2
BAT1
PWM_CFG1
FAN7
FAN6
FAN5
DDR5_B2
DDR5_B1
DDR5_A2
DDR5_A1
PSU_SMB1
ATXPWR1
FAN4
CPU1
USB3_3_4
FAN3
FAN2
FAN1
OCU4
OCU2
OCU1
USB_5
PANEL1AUX_PANEL1
TPM_BIOS_PH1SATA_SGPIO1
SATA_6_7SATA_4_5
BUZZER1
SPEAKER1
NUT30_1
M2_1
NUT42_1
NUT60_1
NUT80_1
IPMB1
BMC_SMB1
OCU3
PCIE4
PCIE5
PCIE6
PCIE7
SPEED
AST2600
BMC
ROM
CLRCMOS1
BIOS
ROM
Dr. Debug
USB_1_2
PECI1TR1
NMI_BTN1SEC_OR1LED_LAN3_4
(EC266D4U-2L2T only)
(EC266D4U-2L2T only)
EC262D4U-2L2T
EC266D4U-2L2T
Intelยฎ๎€Ÿ
C262/C266
IntelยฎX710
8 9
English
No. Description
1 Chassis Fan Connector (FAN6)
2 Chassis Fan Connector (FAN7)
3 Front VGA Header (FRNT_VGA1)
4 PWM Con๎€Ÿguration Header (PWM_CFG1)
5 ATX 12V Power Connector (ATX12V1)
6 ATX 12V Power Connector (ATX12V2)
7 PSU SMBus Header (PSU_SMB1)
8 ATX Power Connector (ATXPWR1)
9 2 x 288-pin DDR5 DIMM Slots (DDR5_A2, DDR5_B2)*
10 2 x 288-pin DDR5 DIMM Slots (DDR5_A1, DDR5_B1)*
11 Chassis Fan Connector (FAN4)
12 Chassis Speaker Header (SPEAKER1)
13 Single Socket (LGA-1700) (CPU1)
14 USB 3.2 Gen1 Header (USB3_3_4)
15 OCuLink x4 Connector (OCU4)
16 OCuLink x4 Connector (OCU2) (EC266D4U-2L2T only)
17 OCuLink x4 Connector (OCU1)
18 USB Connector (USB_5)
19 Chassis Fan Connector (FAN3)
20 Chassis Fan Connector (FAN2)
21 Chassis Fan Connector (FAN1)
22 SATA3 Connectors (SATA_7)(Upper), (SATA_6)(Lower)
23 SATA3 Connectors (SATA_5)(Upper), (SATA_4)(Lower)
24 System Panel Header (PANEL1)
25 Auxiliary Panel Header (AUX_PANEL1)
26 SATA SGPIO Connector (SATA_SGPIO1)
27 SPI TPM Header (TPM_BIOS_PH1)
28 USB 2.0 Header (USB_1_2)
29 CPU PECI Mode Jumper (PECI1)
30 ๎€ermal Sensor Header (TR1)
31 Intelligent Platform Management Bus Header (IPMB1)
32 BMC SMBus Header (BMC_SMB1)
33 Non Maskable Interrupt Button (NMI_BTN1)
34 Security Override Jumper (SEC_OR1)
EC262D4U-2L2T
EC266D4U-2L2T
8 9
English
No. Description
35 Front LAN LED Connector (LED_LAN3_4)
36 OCuLink x4 Connector (OCU3) (EC266D4U-2L2T only)
37 PCI Express 5.0 x16 Slot (PCIE4)
38 Clear CMOS Pad (CLRMOS1)
39 M.2 Socket (M2_1) (Type 2230/2242/2260/2280)
40 PCI Express 4.0 x1 Slot (PCIE5)
41 PCI Express 5.0 x16 Slot (PCIE6)
42 PCI Express 4.0 x4 Slot (PCIE7)
43 Chassis Fan Connector (FAN5)
* For DIMM installation and configuration instructions, please see p.18 (Installation of Memory Modules
(DIMM)) for more details.
10 11
English
No. Item Status Description
1LED_FAN5 Red FAN5 failed
2LED_FAN6 Red FAN6 failed
3LED_FAN7 Red FAN7 failed
4LED_FAN4 Red FAN4 failed
5LED_FAN3 Red FAN3 failed
6LED_FAN2 Red FAN2 failed
7LED_FAN1 Red FAN1 failed
8 SB_PWR1 Green STB PWR ready
9BMC_LED1 Green BMC heartbeat LED
1.5 Onboard LED Indicators
123
4
5
6
7
8
9
EC262D4U-2L2T
EC266D4U-2L2T
10 11
English
1.6 I/O Panel
37
2
189
5
46
No. Description No. Description
1VGA Port (VGA) 6 1G LAN RJ-45 Port (LAN2)**
2 Serial Port (COM1) 7 10G LAN RJ-45 Port (LAN3)***
3 USB 3.2 Gen1 Ports (USB3_1_2) 8 10G LAN RJ-45 Port (LAN4)***
4 LAN RJ-45 Port (IPMI_LAN)* 9 UID Switch (UID1)
51G LAN RJ-45 Port
(LAN1, shared NIC)**
LAN Port LED Indications
*๎€ere is an LED on each side of IPMI LAN port. Please refer to the table below for the
LAN port LED indications.
IPMI LAN Port LED Indications
Activity / Link LED Speed LED
Status Description Status Description
O๎€œ No Link O๎€œ 10M bps connection or no
link
Blinking Yellow Data Activity Orange 100M bps connection
On Link Green 1Gbps connection
ACT/LINK LED
SPEED LED
LAN Port
12 13
English
**๎€ere is an LED on each side of 1G LAN port. Please refer to the table below for the LAN
port LED indications.
1G LAN Port LED Indications
Activity / Link LED Speed LED
Status Description Status Description
O๎€œ No Link O๎€œ 10Mbps connection or
no link
Blinking Yellow Data Activity Orange 100Mbps connection
On Link Green 1Gbps connection
***๎€ere is an LED on each side of 10G LAN port. Please refer to the table below for the
LAN port LED indications.
10G LAN Port LED Indications
Activity / Link LED Speed LED
Status Description Status Description
O๎€œ No Link O๎€œ 100Mbps Connection
or No Link
Blinking Yellow Data Activity Orange 1Gbps Connection
On Link Green 10Gbps Connection
ACT/LINK LED
SPEED LED
LAN Port
SPEED LED
ACT/LINK LED
LAN Port
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

ASRock Rack EC262D4U-2L2T User manual

Category
Server/workstation motherboards
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI