GAS CONVERSION INSTRUCTIONS
DIRECT VENT GAS FIREPLACE
DVCT36CFP95P CONVERSION KIT PART NUMBER 37507
FOR CONVERSION TO NATURAL GAS
WARNING
This conversion kit must be installed by an Empire Comfort Systems distributor (or other qualied agency¹)*in
accordance with the manufacturers instructions and all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result in serious injury or property damage. The qualied
agency performing this work assumes responsibility for this conversion.
1National Fuel Gas Code Z223.1 (Latest Edition)
*The term “qualied individual, rm, corporation or company which either in person or through a representative
is engaged in and is responsible for (a) the installation of gas piping or (b) the connection, installation repair,
or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has
complied with all the requirements of the authority having jurisdiction.
CHECK SAFETY SHUTDOWN PERFORMANCE
WARNING
Perform the safety shutdown test anytime work is done on a gas system to avoid the possibility of re or explosion
with property damage, personal injury or loss of life.
SAFETY SHUTDOWN SYSTEM
Intermittent Pilot System
1. Turn "OFF" using remote control. Main burner and pilot should go off.
2. Pilotgasowshouldstopwithin30seconds.
PARTS LIST
PART DESCRIPTION CONVERSION KIT - 36885
QUANTITY
SUPPLIED
MainBurnerOrice,Front P300 1
MainBurnerOrice,Rear P319 1
SIT Gas Valve Conversion Kit R11381 1
Gas Conversion Label 1224 1
Target 37261 2
ToolsNeeded:StandardScrewdriver,1/4InchHexDriver,5/16InchHexDriver,7/16InchWrench,and7/16InchDeepSocketSet
Gas input for direct-vent replace converted to Natural gas: DVCT36CFP95N - 40,000 BTU per hour
Thedirect-ventgasreplacewhenconvertedtoNaturalgaswillhaveamanifoldpressureofapproximately
3.5inchesw.c.(.871kPa)atthevalveoutletwiththeinletpressuretothevalvefromaminimumof4.5inchesw.c.
(1.120kPa)forthepurposeofinputadjustmenttoamaximumof14.0inchesw.c.(3.484kPa).
37326-0-1116Page 2 Empire Comfort Systems Inc. • Belleville, IL
INSTRUCTIONS FOR CONVERSION
1. Ifthereplaceisinstalled,turnOFFgasandelectricsupply
toreplacebeforemakinggasconversion.AllowFireplaceto
coole completely.
2. Removebarrierscreen,glassdoor,logsandembers,and
liners. (See Homeowner's Manual)
Figure 1
3. Removefrontandrearburnersbyremovingscrewsonleft
andpullingouttowardsleftside.(Figure 2)
Figure 2
.
4. Remove(2)screwsholdingpilotassemblytoburnerpan.
Thiswillallowpilotassemblytodrop.(Figure 3)
Figure 3
5. Remove(2)screwsholdingburnerbaseinplace.
Liftburnerbaseoutofrebox.(Figure 4)
Figure 4
6. Usea7/16inchdeepsocketsettoremoveorices.
(Figure 5)
REAR
FRONT
REAR
FRONT
Figure 5
7. Locatetheoricemarked"2.40."Usea7/16inchdeep
socketsettoinstalloricemarked"2.40"ontorearorice
holder.Useneedle-nosepliers,screwreartargetontorear
oriceholder.(Figure 6)
8. Locatetheoricemarked"48."Usea7/16inchdeepsocket
settoinstalloricemarked"48"ontofrontoriceholder.
Useneedle-noseplierstoscrewfronttargetontoorice
holder. (Figure 6)
REAR
FRONT
Figure 6
37326-0-1116 Page3Empire Comfort Systems Inc. • Belleville, IL
9. Loosenrearairshutterscrewandrotatehandletotheleft
until1/8inchopeningisachievedandtightendownscrew.
(Figure 7)
10.Repeatwithfrontuntilfullyclosed.
REAR AIR
SHUTTER
SCREW
FRONT AIR
SHUTTER
SCREW
CLOSED
OPEN
REAR
FRONT
Figure 7
11. Usea7/16inchopenwrenchtoloosenpilotbodybyslightly
turningcounterclockwise.Slideoricebrackettootherside
andtightenpilotbodyclockwise.(Figure 8)
“NAT” MARKING
Figure 8
12. Replaceitemsremovedinsteps2-5inreverseorder.
13.Gasconversioniscompleted.
Checkthemainburnerameandpilotburneramemustbe
checkedforproperamecharacteristics,asoutlinedinthe
InstallationInstructionsandOwner'sManual.
Verify Input Rate of Converted Fireplace
Checktheinputofthereplace:
1.Turnoffallothergasappliances.Clockthegasmeterand
determine the number of seconds required to consume one
cubic foot of gas.
2.3600÷time(inseconds)=cu.ft.perhour.
3.Thencu.ft.perhourxheatingvalueofgas=inputrate
(Btuh).Oninstallationwithoutgasmeters,checkmanifold
for proper pressure.
Ifreplaceisnotinstalledorprojectregistrationcardhasnot
beenreturnedtoEmpireComfortSystem’s,checkofftypeof
gasconvertedtoonthecard.Alsoindicateconversionbyadding
“Conv.” behind type of gas.
37326-0-1116Page 4 Empire Comfort Systems Inc. • Belleville, IL
www.empirecomfort.com
Empire Comfort Systems Inc.
Belleville, IL
If you have a general question
aboutourproducts,pleasee-mail
If you have a service or repair
question,pleasecontactyourdealer.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

American Hearth Rushmore DVCT36 Conversion Kit (LP to Nat) Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI