9
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE
Power indicator not
lighting
Check your whole power
system.
Check and insert the plug
into right position.
Check the indicator plug or
replace the indicator light by
professional.
Close the door or lid,do not
open it frequently.
Do not freeze large quantities
of fresh food at the same time,
nor add goods frequently.
Please place the location of the
appliance as the Manual guide.
1 is the warmest and 7 is the
coldest, please adjust according
to the actual requirements.
1 is the warmest and 7 is the
coldest, please adjust according
to the actual requirements.
Temperature setting is too cold.
Recently added a large quantity of warm food
to the cabinet.
The door or lid is not shut properly or opened
excessively.
Close proximity to heat source or direct
sunlight. Ambient temperature is very high.
Please place the location of the
appliance as the Manual guide.
Do not freeze large quantities
of fresh food at the same time,
nor add goods frequently.
Close the door or lid,do not
open it frequently.
A fuse may be blown or the circuit breaker
tripped, there is no power.
Freezer runs
continuously
Freezer have some
noise when
operating
The refrigerant inside the appliance will make
a gurgling noise as it changes from a liquid to
a gas and back again.
Having trouble
opening the door or
lid
The freezer door or lid may be difficult to open
immediately after closing it.This is normal
difference between the cold interior of the
freezer and the warm air that has just entered
the freezer when it was opened
Temperature setting is too warm.
The door or lid is not shut properly or opened
excessively.
Recently added a large quantity of warm food
to the cabinet.
Close proximity to heat source or direct
sunlight. Ambient temperature is very high.
Internal temperature
not cold enough
CORRECTIVE ACTION
The appliance was not placed in a level.
The fasten screw of compressor was loose.
Abnormal sound of door hinge due to drying
of lubricating oil.
This noise is completely normal.
Choose a level floor to place
the freezer; Adjust the leveling
legs to proper position.
Remove the compressor cabin
cover and tight the fasten screws.
Add some lubricating oil to the
door hingle.
Wait a few minutes,then open
the door or lid.
Plug not fully inserted into the wall outlet
Indicator plug loose or the indicator light was
damaged.