Digisol DG-CS7004 Quick Installation Guide

Category
Network switches
Type
Quick Installation Guide

This manual is also suitable for

DG-CS7000 series User Manual
DG-CS7000 Series
Stallion Chassis Switch
Install guide
V1.0
2012-03-20
As our products undergo continuous development the specifications are subject to change without prior notice
DG-CS7000 series User Manual
2
Content
1 PRODUCT OVERVIEW ..............................................................6
1.1 PRODUCT BRIEF ........................................................................................6
1.2 INTRODUCTION ..........................................................................................7
1.3 MAIN FEATURES ........................................................................................8
1.4 TECHNICAL SPECIFICATIONS .......................................................................9
1.5 PHYSICAL SPECIFICATIONS.......................................................................15
1.6 HARDWARE COMPONENTS .......................................................................16
1.6.1.1 DG-CS7004 Chassis...........................................................................................16
1.6.1.2 DG-CS7010 Chassis...........................................................................................21
1.6.1.3 DG-CS7010-MM-I................................................................................................29
1.6.1.4 DG-CS7000-12GC12GT and DG-CS7000-12GC12GT2XFP ......................32
1.6.1.5 DG-CS7000-48GT...............................................................................................35
1.6.1.6 DG-CS7004-MM-12GC12GT1XFP...................................................................36
1.6.1.7 DG-CS7000-4XFP...............................................................................................38
1.6.1.8 DG-CS7000-48GX...............................................................................................40
1.6.1.9 DG-CS7004-MM-12GC12GX1XFP ..................................................................41
1.6.1.10 DG-CS7000-12GC12GX and DG-CS7000-12GC12GX2XFP....................44
1.6.1.11 DG-CS7010-MM-II ............................................................................................46
1.6.1.12 DG-CS7000-12GT24GX and DG-CS7000-12GT24GX2XFP ....................49
DG-CS7000 series User Manual
3
1.6.1.13 DG-CS7000-12GC12GT (R2) and DG-CS7000-12GC12GT2XFP (R2) ..52
1.6.1.14 DG-CS7000-48GX (R2)....................................................................................55
1.6.1.15 DG-CS7004-MM-12GC12GT1XFP (R2) .......................................................56
1.6.1.16 DG-CS7010-MM-I (R2).....................................................................................59
Power supply............................................................................................................ 63
1.6.1.17 DG-SA-RPS-7004AC........................................................................................63
1.6.1.18 DG-SA-RPS-7004DC........................................................................................65
1.6.1.19 DG-SA-RPS-7010AC........................................................................................67
Power Distribution Box .............................................................................................69
1.6.1.20 DG-CS7004 Power Distribution Box...............................................................69
1.6.1.21 DG-CS7010 Power Distribution Box...............................................................70
System Backplane ................................................................................................... 71
Fan Tray................................................................................................................... 72
1.6.1.22 DG-CS7004 Fan Tray.......................................................................................72
1.6.1.23 DG-CS7010 Fan Tray.......................................................................................73
Dust Gauze .............................................................................................................. 75
1.6.1.24 DG-CS7004 Dust Gauze..................................................................................75
1.6.1.25 DG-CS7010 Dust Gauze..................................................................................76
Rear Panel ............................................................................................................... 76
1.6.1.26 DG-CS7004 Rear Panel...................................................................................76
DG-CS7000 series User Manual
4
1.6.1.27 DG-CS7010 Rear Panel...................................................................................77
Side Panels .............................................................................................................. 79
1.6.1.28 DG-CS7004 Side Panels..................................................................................79
1.6.1.29 DG-CS7010 Side Panels..................................................................................80
1.7 SYSTEM FEATURES..................................................................................81
DG-CS7004 System Features..................................................................................81
DG-CS7010 System Features..................................................................................82
2 HARDWARE INSTALLATION ...................................................83
1.8 INSTALLATION NOTICE..............................................................................83
Basic Requirements ................................................................................................. 83
1.8.1.1 Site Requirements ...............................................................................................83
1.8.1.2 Temperature and Humidity Requirements.......................................................84
1.8.1.3 Dust and Particles ...............................................................................................86
1.8.1.4 Preventing Electrostatic Discharge Damage...................................................87
1.8.1.5 Anti-interference Requirements.........................................................................87
1.8.1.6 Rack Configuration ..............................................................................................88
1.8.1.7 Power Supply Requirements .............................................................................89
Safety Guidelines ..................................................................................................... 90
Safety Warning......................................................................................................... 91
Hot Line Work Safety Guidelines ............................................................................. 91
DG-CS7000 series User Manual
5
1.9 PREPARING FOR INSTALLATION .................................................................93
Checking Switch Hardware Configuration and Accessories..................................... 93
Required Tools and Fixings...................................................................................... 93
1.10 HARDWARE INSTALLATION ......................................................................93
Switch Installation ....................................................................................................94
1.10.1.1 Desktop installation ...........................................................................................94
1.10.1.2 Rack-mounting DG-CS7000 series ................................................................95
1.10.1.3 Wearing an ESD Wrist Strap .........................................................................100
Switch grounding.................................................................................................... 100
Card and module installation.................................................................................. 102
1.10.1.4 Removing and Installing the Cards...............................................................102
1.10.1.5 Removing and installing the Dust Gauze.....................................................103
1.10.1.6 Removing and Installing the Fan Tray .........................................................105
1.10.1.7 Removing and Installing Power Supply Modules .......................................109
Connecting to the Console ..................................................................................... 113
Connecting to the Management Port...................................................................... 113
SFP transceiver installation.................................................................................... 114
Copper Cable/Fiber Cable Connection................................................................... 115
Power supply connection ....................................................................................... 117
DG-CS7000 series User Manual
1 Product Overview
RECOMMENDATION:
Please read this manual first before using the switch,
following the instructions to avoid damaging the device.
1.1 Product Brief
FIG
1-1 DG-CS7004 Switch
6
DG-CS7000 series User Manual
FIG
1-2 DG-CS7010 Switch
1.2 Introduction
DIGISOL DG-CS7000 series is a high performance routing switch that can be deployed
as a core layer device for campus and enterprise networks, or an aggregation device for IP
metropolitan area networks (MAN).
DG-CS7004 provides 4 slots. DG-CS7010 provides 10 slots, 8 of which are interface
module slots.
DG-CS7000 series supports various types of line cards, and can seamlessly support
network interfaces from 100Mb, 1000Mb to 10GB Ethernet. Featuring functions such as
7
DG-CS7000 series User Manual
8
policy-based routing, IPv6, and load balance, it is capable of flexibly meeting the different
requirements of complex customer environments. Furthermore, DG-CS7000 series allows
redundancy for management modules, power supply. It supports both AC-input and DC-input*
power supplies, with hot-swapping support for cards, power supplies and fans. The working
temperature of all cards can be monitored in real-time, offering carrier-class reliability.
1.3 Main Features
DG-CS7004 4 slots that can be configured in Primary controller-Primary Backup mode
with 2 management modules and 2 network modules, or Single controller mode with one
management module and 3 network modules.
DG-CS7010 10 slots that can be configured in Primary controller-Primary Backup mode
with 2 management modules and 8 network modules, or Single controller mode with one
management module and 8 network modules.
Store-and-forward switching, ensuring minimal latency.
Auto MDI/MDI-X, enabled on all RJ-45 ports, allows connections to other switches using a
non-crossover twisted pair cable.
Full-duplex IEEE802.3x flow control, half-duplex backpressure flow control.
Console management port provided.
Port working status and statistics available.
Restart and reset to factory setting can be done both locally and remotely.
DG-CS7000 series User Manual
9
TFTP /FTP firmware upgrade available.
Can be installed into standard 19-inch chassis.
1.4 Technical specifications
Item DG-CS7004 DG-CS7010
Slot
4
10
Port
10/100/1000BASE-T, 188 at best
1000Base-SX, 188 at best
1000Base-LX, 188 at best
10GBase, 13 at best
10/100/1000BASE-T, 384 at best
1000Base-SX, 384 at best
1000Base-LX, 384 at best
10GBase, 32 at best
Backboard
bandwidth
1.2Tbps(can extend to 2.4Tbps) 2.4Tbps(can extend to 4.8Tbps)
Exchange capacity 640Gbps
1.28Tbps/2.4Tbps (the second
generation engine)
Packet Forwarding
Speed
476Mpps
952Mpps/1785Mpps (the second
generation engine)
Forwarding Delay
Time among Ports
<=6ms <=6ms
VLAN Item 4K 4K
DG-CS7000 series User Manual
10
Layer 2 Protocol
Specifications
IEEE802.3(10Base-T), IEEE802.3u(100Base-TX), IEEE802.3z(1000BASE-X),
IEEE802.3ab(1000Base-T), IEEE802.3ae(10GBase), IEEE802.1Q(VLAN),
IEEE802.3ak(10GBASE-CX4), IEEEE802.1d(STP), IEEEE802.1W(RSTP),
IEEEE802.1S(MSTP), IEEE802.1p(COS), IEEE802.1x(Port Control),
IEEE802.3x(Flow control), IEEE802.3ad(LACP), Port Mirror, RSPAN, ULDP ,
LLDP, IGMP Snooping, QinQ, GVRP,VLAN, PVLAN, VOICE VLAN, Protocol
Vlan, Multicast VLAN, Mac Vlan, Broadcast Storm Control
Layer 3 Protocol
Specifications
(IPv4)
Support ARP, ARP Proxy, ARP Limiting Speed, ARP Repeat-
A
uthentication,
Gratuitous ARP
Support DNS client
Support Static Routing, RIPv1/v2, OSPFv2, BGP4, GRE Unicast Routing
Protocol etc.
Support Routings for OSPF’s different process import each other
Support LPM Routing, Policy-based Routing(PBR), ECMP
Support VRRP, URPF, Black Hole Routing
Support IGMP v1/2/3, DVMRP, PIM-DM, PIM-SM, PIM-SSM, IGMP Proxy,
anycast RP, MSDP, Static multicast Routing, boundary multicast Routing etc.
Strengthen Extend
Support in-embed firewall, IDS, IPSce VPN, Content-exchange service, Network
Analysis hardware module etc.
Free-Resource Support
DG-CS7000 series User Manual
11
IPv6
Support ICMPv6, ND, DNSv6
Support IPv6 LPM Routing, IPv6 Policy-based Routing(PBR)
Support IPv6 VRRPv3, IPv6 URPF, IPv6 Black Hole Routing
Support RIPng, OSPFv3, BGP4+ Unicast Routing Protocol etc.
Support 6to4 Tunnels, configured Tunnels, ISATAP etc.
Support MLD Snooping, IPv6 Muticast VLAN
Support MLDv1/v2, PIM-SM/DM for IPv6, IPv6 anycast RP, IPv6 Static multicast
Routing, IPv6 boundary multicast Routing, IPv6 multicast tunnel etc.
Support IPv6 ACL, IPv6 QOS
Strengthen
A
RP/NDP Safety
function
Support ARP/NDP Spoofing Prevention, ARP/NDP Scanning Prevention
MPLS MPLS, LDP, MPLS VPN, MPLS TE, Access public network technology
QoS
Carry out by hardware completely, have no effect for performance.
Each port has 8 queues. Support SP, WRR, SWRR queue scheduling algorithm.
Support traffic class base on 802.1p, ToS, port, DiffServ
Class traffic by ACL; configure the COS, TOS, DSCP bases class result. Class
traffic by high-layer content for ACL-X’s 80 bytes
Support SP, WRR, SWRR etc. Provide different service quality requested for
speech, data and video transmit at the same network.
Support Traffic Shaping
Support priority Mark/Remark
DG-CS7000 series User Manual
12
ACL
Carry out by hardware completely, have no effect for forwarding performance.
Support Standard ACL and Extended ACL
Support IP ACL, base on IP-subnet ACL, MAC ACL, IP-MAC ACL,
Support IP or MAC based on source/destination, Layer 3 IP protocol type,
TCP/UDP layer 4 port number, IP priority (DSCP, ToS, Precedence), base on
VLAN, Tag/Untag, CoS etc.
Support REDIRECT based on ACL, Traffic statistic based on ACL
ACL-X
Support to transfer security policy automatically base on time.
A
CL’s deepness content can be used for QoS sort standard, the deepness can
extend 80 bytes.
DCSCMv4/v6
Support IPv4/IPv6 Multicast Source Controllable, Prevent lawless Multicast
Source
Support IPv4/IPv6 multicast user Controllable
Support IPv4/IPv6 policy multicast
DG-CS7000 series User Manual
13
Port Function
Support MAC+ port binding, IP+ MAC+ port binding, IP+ port binding
Support MAC filter
Support Port Limit(bandwidth management)
Support Port Loopback Detection
Support Port Mirror(CPU Port Mirror, ingress or egress unilateralism/
bidirectional, one-to-one, many-to-one, stride board, stride equipment),
Support Flow Control: HOL prevent head-packet block, half-duplex back
pressure, full-duplex IEEE802.3x
Support Port aggregation IEEE802.3ad(LACP), port-to-port GEC/FEC, each
trunk can up to 8 ports, support load equipoise
DHCPv4/v6
Support IPv4/IPv6 DHCP Client, IPv4/IPv6 DHCP Relay, IPv4/IPv6 DHCP
Snooping
Inside-install IPv4/IPv6 DHCP Server, DHCP Option82
Security Access Support IEEE 802.1x, DCSM
AAA
Authentication
Support IPv4/IPv6 RADIUS
DG-CS7000 series User Manual
14
Security Function
Configuration
Support IPv4/IPv6 syslog
Support the unite for IPv4/IPv6 HTTP and SSL
Support the user IP security inspection for IPv4/IPv6 SNMP
Support MIB and TRAP
Support IPv4/IPv6 FTP/TFTP
Support IPv4/IPv6 NTP
Support RMOM 1, 2, 3, 9 four group
Support the RADIUS authentication for IPv4/IPv6 telnet user name and
password
Support IPv4/IPv6 SSHs
The right configuration for users can adopt radius server’s shell management
Support the function for timing-reset bases needs
sFlow Function
Support network flow analysis,Support RFC3176,can realize the flow
monitoring and statistic based on protocol or address
IPFIX A standard protocol can measure the flow information of the IETE network
Exception
monitoring and
fault check-up
Monitoring the Task exception, Memory exception, CPU utilance, Stack
exception, Switching-chip exception, board temperature exception etc. And
giving an alarm
Centralized Web
Management
Software
It is adopted the DIGISOL centralized web management software LinkManager’
for unified management.
DG-CS7000 series User Manual
15
1.5 Physical Specifications
Management Port
One RJ-45 serial port for each management module
AC Power Input
Input: 90~264V, 50 ~ 60Hz
Built-in Universal Power Supply
DC Power Input
Input: -36V~ -72VDC
Built-in Universal Power Supply
Power Consumption
DG-CS7004: 400W Max
DG-CS7010: 1200W Max
Operating Temperature
0C ~ 45C
Storage Temperature
-40C ~ 70C
Relative humidity
10% ~ 90% with no condensate
Dimension
DG-CS7004 440mm×266mm×421mm (W x H x D)
DG-CS7000 series User Manual
16
DG-CS7010 436mm×797mm×478mm (W x H x D)
Weight
DG-CS7004: 30kg (max. full configuration weight)
DG-CS7010: 65kg (max. full configuration weight)
Mean Time Before Failure
Min. 80,000 Hours MTBF
1.6 Hardware Components
DG-CS7004 consists of the chassis, power supply system, ventilation system, system
board, etc.
1.6.1.1 DG-CS7004 Chassis
The DG-CS7004 uses a 19-inch Rack Mountable Chassis, with the standard dimensions
of 440mm (W) x 266mm (H) x 421mm (D). The chassis consists of functional block and power
supply block. The function module block is a board rack, which is the supporting structure for
DG-CS7004 system boards (4 boards max). The fan block is located on the left side of the
board rack, allowing one fan tray (4 axial fans for each fan tray). Dust gauze is provided on
the right of the board rack for filtering air circulation through the rack. The power block upper
the dust gauze provides power to the system, supporting up to two power modules. The
power modules insert into the power slots from the front, with the distribution box at the back
of the rack for maintenance.
DG-CS7000 series User Manual
In addition, there is an ESD Wrist Strap Connectors on the board rack, located on the left
side of the upper.
Fig 1-3 DG-
CS7004 Module Outlook
17
DG-CS7000 series User Manual
Fig 1-4 DG-CS7004 Front Panel View
① Management slot: It supports two management slots. DG-CS7004-MM-
12GC12GX1XFP can be inserted in to the Management slots. The second
slot can also be used as I/O slot for configuring various I/O modules.
② Network slot: 2 network slots are provided. Various network modules can
be added to the network slots. Such as DG-CS7000-4XFP and DG-
CS7000-12GC12GT etc.
Power slot: Used for system power supply modules. Support up to two
400W AC/DC modules.
Fan tray slot: Supports up to one system fan assemblies, each assembly
consists of four axial fans.
⑤ Dust gauze slot: Exterior air inlet for the ventilation subsystem.
Distribution box slot: For system distribution box use, works in AC mode
based on the power modules.
1.6.1.1.1 Board Rack
The board rack consists of board slots and a system board.
The boards are inserted vertically into the DG-CS7004 4 unit boards are provided. There are
four slots in DG-CS7004 from number 1 to number 4 in order of top to down. The first slot is
18
DG-CS7000 series User Manual
19
used to install management module; the second slot is used to management module under
1+1 redundant backup mode or install various I/O interface modules.
A reset button (printed on the panel as
Reset
), hot swap button (printed on the panel as
SWAP
), board power indicator (printed on the panel as
PWR
) and board running status
indicator (printed on the panel as
RUN
) are provided for each board. On the Main Control
cards there is Master-Slave indicator (printed on the panel as
M/S
) There is also a power
module status indicator (printed on the panel as
Power
), fan assembly status indicator
(printed on the panel as
Fan
), and interface status indicators for corresponding management
interfaces and network interfaces (printed on the panel as
Link
and
Act
).
The DG-CS7004 system board is an essential part of the switch, located inside the
switch and providing interconnectivity between the management switch modules (short for
management card
) and network interface modules (
line card
), and for all management and
control signals.
DG-CS7000 series User Manual
20
1.6.1.1.2 Power Supply
When using A.C. power supply, we shall adopt power supply of 110V/220V and
corresponding A.C. distribution box. The permissible range of power supply is 90~264VAC,
50~60Hz. The maximum output power of single power supply module is 400W.
When using D.C. power supply, we shall adopt power supply of -48V and corresponding
D.C. distribution box. The permissible range of power supply is -36V~-72VDC. The
maximum output power of single power supply module is 400W.
1.6.1.1.3 Ventilation and Cooling System
The operating ambient temperature of the DG-CS7004 is 0 ~ 45C, the thermal design
of the equipment can ensure that the surface temperature of the device will not exceed 50-
80% of the highest temperature allowable.
The switch uses fan assemblies to disperse heat, with the air flow being drawn in through
the right section and out through the left section to facilitate air circulation, so that the switch
can maintain normal operation under specified environmental conditions. The fan tray is
attached to the fan tray slots left the board rack, and ventilation is provided via 4 axial fans
that pump out air. Fan trays are hot swappable for maintenance, their status are indicated by
the FAN indicators on the main switch panel. In addition, dust gauze is provided on the right
of the board rack for filtering the air circulating through the rack. The dust gauze can be
unplugged and removed through the back for maintenance.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118

Digisol DG-CS7004 Quick Installation Guide

Category
Network switches
Type
Quick Installation Guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI