Magne 3 and 4
Electromagnetic process lock
2TLC172315M0201, rev K 2 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Please read and familiarize yourself with the contents of this user
manual.
Please read and familiarize yourself with the contents of this user manual before starting to use the products.
Please contact your ABB JOKAB SAFETY representative if you have any questions or comments.
GUARANTEE
ABB JOKAB SAFETY guarantees that the products are free from material or performance defects for one (12)
months (or other period if stated) from date of purchase from ABB JOKAB SAFETY.
ABB JOKAB SAFETY DISCLAIMS GUARANTEES OF ALL KIND, EXPRESSED OR IMPLIED, ON NON
INFRINGEMENT, SALEABILITY OR SUITABILITY FOR CERTAIN PURPOSES WHERE THE BUYER OR USER
ALONE DETERMINES WHETHER THE PRODUCTS MEETS THE REQUIREMENTS OR ARE SUITABLE FOR A
SPECIFIC PURPOSE. ABB JOKAB SAFETY OFFERS NO ADDITIONAL GUARANTEES, EITHER EXPRESSED
OR IMPLIED
LIMITATION OF LIABILITY
ABB JOKAB SAFETY DISCLAIMS LIABILITY FOR SPECIFIC, INDIRECT OR CONSEQUENTIAL DAMAGE,
LOSS OF REVENUE OR BUSINESS OF ANY KIND IN RELATION TO THESE PRODUCTS, IRRESPECTIVE OF
SUCH A CLAIM BEING BASED ON AN AGREEMENT, GUARANTEE, CARELESSNESS OR PURE LIABILITY.
Under no circumstances, can ABB JOKAB SAFETY's liability exceed the cost of the individual product for which
liability is cited.
ABB JOKAB SAFETY IS NOT LIABLE UNDER ANY CIRCUMSTANCES FOR ANY GUARANTEE, REPAIR OR
OTHER CLAIMS WITH REGARD TO THE PRODUCTS IF ABB JOKAB SAFETY’S ANALYSIS CONFIRMS THAT
THE PRODUCTS HAVE NOT BEEN CORRECTLY HANDLED, STORED, INSTALLED OR MAINTAINED OR
SUBJECTED TO DAMAGE, INCORRECT USAGE OR INAPPROPRIATE MODIFICATION OR REPAIR.
PRODUCT SUITABILITY
ABB JOKAB SAFETY is not liable for compliance with standards, regulations or directives that apply for product
combinations in the customer's application or product usage. ABB JOKAB SAFETY will supply, on customer
request, certification documents from a third party with data on classification and usage limitations for the products.
This information is not in itself sufficient for a complete assessment of the suitability of the products in combination
with the end product, machinery, system or other application or usage.
Please see below several examples of application areas where particular attention must be observed. This is not a
complete list of all possible application areas for the products, nor is it claimed that the application areas named are
suitable for the products in question:
Outdoor use, application areas that entail risk of chemical contamination or electric shocks or conditions or
application areas that are not described in this manual.
Control systems for nuclear power, combustion systems, railway systems, aviation systems, medical equipment,
slot machines, vehicles and installations that are subject to separate industry directives or national regulations.
Systems, machinery and equipment that can comprise danger to life or property.
Check and take note of all prohibited application areas for the products.
NEVER USE THE PRODUCTS IN AN APPLICATION THAT ENTAILS SERIOUS DANGER TO LIFE OR
PROPERTY WITHOUT FIRST ASCERTAINING THAT THE SYSTEM AS A WHOLE IS DESIGNED TO MANAGE
SUCH RISKS, AND THAT THE PRODUCT FROM ABB JOKAB SAFETY HAS THE RIGHT CLASSIFICATION
AND IS PROPERLY INSTALLED FOR THE USE INTENDED AS PART OF EQUIPMENT OR SYSTEMS.
PERFORMANCE INFORMATION
Even though everything has been done to ensure the veracity of the information in this manual,
ABB JOKAB SAFETY disclaims liability for errors or omissions and reserves the right to make changes and
improvements without prior notice. The information on product performance provided in this manual is intended for
guidance purposes only for the user when assessing the product's suitability and does not comprise any guarantee.
This can concern tests performed by ABB JOKAB SAFETY and the user must observe the requirements for the
application intended. For actual performance, please see the wording in ABB JOKAB SAFETY's Guarantee and
Limitation of Liability.
2TLC172315M0201, rev. K 3 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Contents
1 Introduction ..................................................................................................................................... 4
Scope ........................................................................................................................................................................ 4
Dear reader, .............................................................................................................................................................. 4
Prior knowledge ........................................................................................................................................................ 4
Specific comments .................................................................................................................................................... 4
2 Overview .......................................................................................................................................... 5
General description ................................................................................................................................................... 5
Safety directives........................................................................................................................................................ 5
3 Connections .................................................................................................................................... 6
Magne 3X .................................................................................................................................................................. 6
Magne 4X DYN ......................................................................................................................................................... 7
Magne 4 DYN-Info .................................................................................................................................................... 8
Magne 4 OSSD-Info ................................................................................................................................................. 9
4 Connecting .................................................................................................................................... 10
Series connection of Magne 4 DYN-Info ................................................................................................................ 10
Series connection of Magne 4 OSSD-Info .............................................................................................................. 12
5 Installation and maintenance ....................................................................................................... 14
Installation directions .............................................................................................................................................. 14
Maintenance ........................................................................................................................................................... 15
Positioning and orientation of Eva. ......................................................................................................................... 15
Testing of safety functions ...................................................................................................................................... 15
Replacing Eva ......................................................................................................................................................... 16
Troubleshooting ...................................................................................................................................................... 17
6 Operation ....................................................................................................................................... 18
LED indication ......................................................................................................................................................... 18
7 Overview of models....................................................................................................................... 19
Accessories and spare parts (not included) ........................................................................................................... 19
8 Technical data ............................................................................................................................... 21
Dimensions ............................................................................................................................................................. 24
9 EU Conformity ............................................................................................................................... 26
2TLC172315M0201, rev K 4 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
1 Introduction
Scope
These user instructions are intended to describe the Magne electromagnetic process lock and to provide necessary
information required for assembly, installation, checking and adjusting after installation and maintenance. These
instructions contain basic information needed for the electrical installation of Magne.
Dear reader,
This document is intended for authorized installation personnel.
Prior knowledge
It is assumed that the reader of this document has knowledge of the following:
Basic knowledge of products from ABB Jokab Safety.
General knowledge about safety devices and process locks.
General knowledge of equipment safety
Specific comments
Please pay attention to the following specific comments throughout the entire document:
Warning
Risk of serious personal injury
An instruction, directive or procedure that, if not performed correctly, can cause injuries to
operators or other personnel.
Caution
Risk of damage to the equipment.
An instruction, directive or procedure that, if not performed correctly, can lead to damage to the
equipment.
Important!
Comments that are made to provide important or explanatory information.
2TLC172315M0201, rev. K 5 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
2 Overview
General description
Magne is an electromagnetic process lock that is designed without any moving parts, which means it is
hardwearing and ideal for industrial applications and harsh environments. Magne can keep a door or cover locked
with a holding force of up to 1500 N. When the power is then broken, magnetic materials will not stick to the
surface
Magne 3 is an electromagnetic lock that can be complemented by any choice of external interlocking device.
The Magne 4 variants are electromagnetic locks with an integrated Eden safety sensor for secure interlocking
protection. They are available with dynamic or OSSD signal Magne 4 is available in a choice of different variants.
These include an M12 8-pole connector, which permits information connectors for indication (e.g. when the anchor
plate is locked to the electromagnet). The 5-pole variant has a connector configuration that enables connection to a
Urax B1R adaptor unit for connection to the AS-i-bus.
Two variants of the Magne anchor plate are available. The one coded with a B has an inbuilt permanent magnet,
which holds the door or cover closed with a force of approx. 30 N when the power to the electromagnet is cut.
Magne 3 and 4 are supplied without an anchor plate and Magne 4 is also supplied without Eva (Eva is the passive
part of the non contact sensor that is integrated in Magne 4).
For further details, see chapter Overview of models.
Y-connectors can be used to connect several Magne units and Eden sensors in series, which enables control and
monitoring with one single Pluto safety PLC or Vital safety module
No current spikes over the rated current when locking is activated, which simplifies dimensioning of the system.
Safety directives
Warning
Please carefully read the entire user instructions before you use the unit.
Installation of these units should always be done by a qualified electrician who follows the safety
directives, standards stated and the machinery directive.
Failure to comply with instructions, usage that is not in accordance with that stated in these
instructions and incorrect installation or handling of the unit can endanger the safety of individuals
and the facility.
The comments provided are to be carefully followed on installation and during prescribed use of
the product, and the technical standards relevant to the application must be observed.
Failure to comply with these instructions or standards, and in particular in the case of manipulation
and/or modification of the product, invalidates all liability.
2TLC172315M0201, rev K 6 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
3 Connections
Important!
Shielded cable ought to be used to connect this unit.
Caution
All cable colors are in accordance with ABB Jokab Safety standard cabling.
Magne 3X
Important!
Several Magne 3X can be locked with a M12-3A, but then no information will be sent back.
Warning
The info output is non-failsafe and must therefore never be used to control a safety application.
M12 5 pole male
connector seen from
the cable side.
M12 5 pole female
connector seen from
the cable side.
M12 5-pole connector:
1 ) Brown: +24 VDC/Lock signal
2 ) White: Not used
3 ) Blue: 0 V
4 ) Black: Not used
5 ) Gray: Info output, locked
2TLC172315M0201, rev. K 7 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Magne 4X DYN
Important! Shielded cable is necessary between the unit and the rest of the safety loop.
Important! Several Magne 4X DYN can be locked with a M12-3S, but then no information will be sent back.
M12 5-pole connector:
1 ) Brown: +24 VDC
2 ) White: Dynamic signal in
3 ) Blue: 0 V
4 ) Black: Dynamic signal out
5 ) Gray: Locking signal +24VDC
M12 5 pole male
connector seen from
the cable side.
M12 5 pole female
connector seen from
the cable side.
2TLC172315M0201, rev K 8 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Magne 4 DYN-Info
Warning
The info output is non-failsafe and must therefore never be used to control a safety application.
The safe dynamic or OSSD signals from the interlocking device Eden is used to control the safety
application.
Important!
Shielded cable is necessary between the unit and the rest of the safety loop.
M12 8-pole connector:
1 ) White: Dynamic signal in
2 ) Brown: +24 VDC
3 ) Green: Locking signal +24 VDC
4 ) Yellow: 0 V
5 ) Gray: Info output (Eden + Locked)
6 ) Pink: Dynamic signal out
7 ) Blue: 0 V
8 ) Red: Not used
M12 8 pole male
connector seen from
the cable side.
M12 8 pole female
connector seen from
the cable side.
2TLC172315M0201, rev. K 9 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Magne 4 OSSD-Info
Warning
The info outputs are non-failsafe and must therefore never be used to control a safety application.
The safe dynamic or OSSD signals from the interlocking device Eden is used to control the safety
application.
Important!
Shielded cable is necessary between the unit and the rest of the safety loop.
Important!
Several Magne OSSD-info can be locked with the aid of M12-3G.
M12 8-pole connector:
1 ) White: OSSD1 out
2 ) Brown: +24 VDC
3 ) Green: OSSD1 in
4 ) Yellow: OSSD2 in
5 ) Gray: Info output (Eden + Locked)
6 ) Pink: OSSD2 out
7 ) Blue: 0 V
8 ) Red: Locking signal +24 VDC
M12 8 pole male
connector seen from
the cable side.
M12 8 pole female
connector seen from
the cable side.
2TLC172315M0201, rev K 10 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
4 Connecting
Several Magne 4s can be connected together in series. However, it is not possible to combine OSSD and dynamic
signals. If only one OSSD is used or if Magne OSSD is the first in the series, +24 VDC must be connected in at
OSSD1 In and OSSD2 In. Otherwise, OSSD output signals will not be generated from Magne. See images below
with examples of series connection of Magne 4 DYN-Info and Magne 4 OSSD-Info.
Series connection of Magne 4 DYN-Info
2TLC010021T0005 Magne 4 Dyn-Info Pluto
2TLC172315M0201, rev. K 11 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
2TLC010021T0004 Magne 4X Dyn Pluto M12-3S
2TLC172315M0201, rev K 12 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Series connection of Magne 4 OSSD-Info
2TLC010021T0003 Magne 4 OSSD Pluto
2TLC010021T0002 Magne 4 OSSD Sentry
2TLC172315M0201, rev. K 13 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
2TLC010021T0001 Magne 4 OSSD Sentry M12-3G
2TLC172315M0201, rev K 14 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
5 Installation and maintenance
Maximum installation tolerance between electromagnet and anchor plate is ±5 mm lengthways to Magne and
±3 mm sideways. Available fittings for closing doors are designed for 515 mm door gap Dimensions for installation
of a sliding door as drawing below.
The anchor plate is mounted with 2 X M8 bolts with cellular rubber between the anchor plate and door. The cellular
rubber enables the anchor plate to adjust to Magne. The cellular rubber should not be compressed to a thickness
less than 8 mm. Choose suitable bolt that reaches the bottom of the anchor plate hole allowing sufficient play in the
cellular rubber to ensure anchor plate movement. Recommended torque is 7 ±2 Nm.
Installation instructions included with the respective installation kit.
Important!
All dimensions given in millimeters.
Positioning of Eva
Installation directions
Please carefully follow the instructions below to avoid personal injuries or damage to the unit.
Caution
After installation, check that the surfaces of the magnet and anchor plate are flush and
parallel such that full contact is obtained with the door is closed.
Installation tolerances (general)
Installation tolerances (sliding door with Magne 3 and JSM
D23)
Magne
2TLC172315M0201, rev. K 15 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Magne must be installed as close to the door handle as possible. The distance between
the lock and the handle creates a lever effect, reducing the operating force necessary to
force the lock. The bigger the distance the greater the risk of the anchor plate not being
flush with the electromagnet, which significantly reduces the holding force.
The holding force of the lock can be significantly reduced if the anchor plate and cellular
rubber have no scope to move. Check that full alignment is always obtained.
It is important that Eva is correctly positioned in relation to the inbuilt Adam sensor (for
Magne 4). See section Positioning and orientation of Eva.
The anchor plate can suffer permanent damage if the tightening torque is greater than
9 Nm (7 ±2 Nm) on installation. The anchor plate is not to be used as the only door stop.
Additional door stops must be used to avoid damaging the Magne.
Warning
The installation tolerance in the inbuilt sensor can be reduced if Magne is installed directly
onto steel. A gap of 2.5 mm between the installation surface and Magne is recommended
to assure performance.
The M12 connector should be connected after Magne has been installed on the intended
surface.
All safety functions must be tested before the unit is commissioned.
Maintenance
The electromagnet should be regularly cleaned to maintain its full holding power.
Warning
The safety functions and mechanism must be regularly tested, at least once a year, to check that
all safety functions are working correctly (EN ISO 13849-1:2015/EN 62061:2005/A2:2015)
Contact your nearest ABB Jokab Safety service center or retailer in the event of a malfunction or product damage.
Do not attempt to repair the product as this can result in permanent damage, which impairs the safety of the unit,
which in turn, can lead to serious personal injuries.
Positioning and orientation of Eva.
This section concerns the Magne 4 only.
The integrated interlocking device Eden consists of two different units, Adam and Eva. The units must be
positioned correctly for the sensor to work as intended. Adam is built into the casing around Magne 4 and sits
between the electromagnet and the M12 connector. The figure below shows Eva correctly positioned above Magne
when the door is closed.
The safety application is based on the Eden sensor deciding if the guard is open or closed, which means it is very
important that the units are carefully positioned, and the safety functions tested.
Testing of safety functions
This section concerns the Magne 4 only. Similar tests should be performed when using an external safe
interlocking breaker together with Magne 3.
Check that the safety functions work by following these steps:
The Eva unit correctly positioned and oriented above the Adam unit that is built into Magne 4.
2TLC172315M0201, rev K 16 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
1) Break the safety circuit before this unit when Eva is in position next to Adam. The LED should blink between
green and red and the safety monitor goes into safe state. For information on indications, see section
Troubleshooting and section LED indication.
2) Reset the safety circuit and safety monitor.
3) Magne should shine green (solid light).
4) Move Eva away from position next to Adam. The LED should change color (solid light) from green to red
and the safety monitor should go to safe state.
5) Move Eva back close to Adam and reset the safety circuit and safety monitor.
Another function test that can be done is to slowly move Eva away from Adam (i.e. slowly open the door from the
fully closed position). The LED should rapidly alternate between green and red when Eva is within 2 mm of the
maximum sensory range of Adam.
Replacing Eva
When a coded Eva needs to be replaced, the old code must be deleted from the internal Adam sensor in Magne.
To delete a coded Eva, follow the instructions below for Eden Dynamic and OSSD. (This is not necessary when
replacing an Eva General with another Eva General.)
Eden Dynamic
1) Move the old Eva out of sensory range.
2) Disconnect the power supply voltage to Magne. (0 V should be connected at all times.)
3) Connect +24 VDC to Dynamic in.
4) Connect power voltage to Magne (marked +24 VDC).
5) Disconnect the voltage to Dynamic in after 5 seconds but within 10 seconds.
The Adam unit in Magne is now reset and Magne should blink red.
6) Disconnect power voltage to Magne (marked +24 VDC).
7) Check that the new Eva is within sensory range and connect the power voltage to Magne.
The LED in Magne should show green and the programming is completed.
Eden OSSD
1) Move the old Eva out of sensory range.
2) Disconnect the power supply voltage to Magne. (0 V should be connected at all times.)
3) Connect +24 VDC to OSSD1 Out and OSSD2 Out.
4) Connect power voltage to Magne (marked +24 VDC).
5) Disconnect the voltage to Dynamic in after 5 seconds but within 10 seconds.
The Adam unit in Magne is now reset and Magne should blink red.
6) Disconnect power voltage to Magne (marked +24 VDC).
7) Check that the new Eva is within sensory range and connect the power voltage to Magne.
The LED in Magne should show green and the programming is completed.
2TLC172315M0201, rev. K 17 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Troubleshooting
This section concerns all Magne 3 and 4.
LED indication
Supposed cause of fault
Check and rectify
No LED light
No voltage supply.
Check +24 VDC/0 V voltage supply.
Blue (blinking)
Anchor missing or not
centered.
Check anchor position.
Blue (rapid blinking)
Overcurrent on attempted
locking.
Unit needs replacing.
Contact ABB Jokab Safety.
This section concerns Magne 4 X-DYN, Magne 4 DYN-Info
LED indication
Supposed cause of fault
Check and rectify
Shines red
Eva away from Adam.
Move Eva within sensory range of Adam.
Metal between Eden sensors.
Remove metal.
Weak light or green
and red showing at
same time
Unit is defective.
Unit needs replacing.
Contact ABB Jokab Safety.
Green and red light
alternating rapidly
Valid Eva code missing
Perform procedure to replace Eva. If it still does not
work, the unit is defective and must be replaced.
Alternating green and
red light
Dynamic signal in missing
Check previous unit.
This section concerns Magne 4 OSSD Info
LED indication
Supposed cause of fault
Check and rectify
Shines red
Eva away from Adam.
Move Eva within sensory range of Adam.
Metal between Eden sensors.
Remove metal.
Lights green (but no
dynamic signal
detected)
Defective dynamic input
signal to unit (asymmetrical
pulses).
Check the dynamic signal to the unit before this in the
safety circuit.
Weak light or green
and red showing at
same time
Unit is defective.
Unit needs replacing.
Contact ABB Jokab Safety.
Green and red light
alternating rapidly
Valid Eva code missing
Perform procedure to replace Eva. If it still does not
work, the unit is defective and must be replaced.
Blinking red/red/green
light
Defective input signal
Restart voltage cycle, if fault recurs, check incoming
signals.
Warning
A defective unit should be replaced with a new unit. Never bypass the safety circuit.
2TLC172315M0201, rev K 18 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
6 Operation
Locking:
1. Close the door.
2. Locking as PLC program (e.g. via signal from push button).
Unlocking:
1. Unlocking as PLC program (e.g. via signal from push button, or automatically when the machine/process
cycle is ended as it is supposed to).
2. Open the door.
LED indication
LED
Indication
Description
LED on Magne
(Magne 4)
Green
Eva close, safety circuit closed (door closed)
GreenRed (blinking)
Eva close, safety circuit broken earlier (door closed)
GreenRed (rapid
blinking)
Eva is within 2 mm of max sensory distance (door closed)
Red
Eva remote, safety circuit broken (door open)
LED on Magne
(Magne 3 and 4)
Blue (rapid blinking)
Overcurrent signaled on attempted locking.
Blue (slow blinking)
Lock signal but Magne not detecting the anchor plate.
Blue
Magne is locked.
2TLC172315M0201, rev. K 19 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
7 Overview of models
Description of the Magne model names
For available fittings for different door types (closing or sliding door), see Accessories and spare parts.
Type
Product code
Description
Magne 3X
2TLA042022R2700
Magne without inbuilt Eden sensor. Electromagnet 1500 N. M12
5 pole connector with output for lock information signal. The lock
information signal is loud when Magne is locked. Supplied
without anchor plate.
Magne 4X DYN
2TLA042022R3000
Magne with inbuilt Adam, no output for information signal.
Electromagnet 1500 N with M12 5-pole connector. Supplied
without anchor plate or Eva.
Magne 4 DYN-Info
2TLA042022R3400
Magne with inbuilt Adam DYN info, with output for information
signal. The information signal is loud if both Eva is within range
and Magne is locked. Electromagnet 1500 N with M12 8 pole
connector. Supplied without anchor plate or Eva.
Magne 4 OSSD-Info
2TLA042022R4600
Magne with inbuilt Adam OSSD info, with output for information
signal. The information signal is loud if both Eva is within range
and Magne is locked. Electromagnet 1500 N with M12 8 pole
connector. Supplied without anchor plate or Eva.
Accessories and spare parts (not included)
Type
Product code
Description
Accessories
2TLA020046R0800
Eva with general coding
Accessories
2TLA020046R0900
Eva with general coding
Accessories
2TLA042023R1300
Anchor plate 32A incl. cellular rubber (32 mm wide, without permanent
magnet).
Accessories
2TLA042023R0400
Anchor plate 32B incl. cellular rubber (32 mm wide, without permanent
magnet).
Accessories
2TLA042023R0100
JSM D28 handle profile in aluminum that completely conceals Magne
with door closed. For closing door (515 mm door gap). Fits all Magne.
Eva installed in the profile.
Accessories
2TLA042023R0500
JSM D21B installation kit for Magne.
For closing door (515 mm door gap). Fits all Magne.
Important! An installation kit is also required for Eva (JSM D24) when
installing Magne 4.
Accessories
2TLA042023R0200
JSM D23 installation kit for Magne. For sliding door. Fits all Magne.
Accessories
2TLA042023R0300
JSM D24 installation kit for Eva. For sliding door.
Accessories
2TLA042023R1000
JSM D27 handle for JSM D21B.
Spare part
2TLA042023R3600
Cellular rubber for Anchor plate.
Accessories
2TLA020055R0000
M12-3A Y connector for connecting several units in series. For Magne
3X. Individual status not possible. Cascade locking.
Accessories
2TLA020055R0600
M12-3S Y connector for connecting several units in series. For
Magne 3X and Magne 4X Dyn. Cascade locking.
2TLC172315M0201, rev K 20 www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Accessories
2TLA020055R0700
M12-3G Y connector for connecting several units in series. For Magne
4 OSSD-Info
Accessories
2TLA020053R7100
JSOP-2. Terminal plug for Y connector M12-3G.
Accessories
2TLA020054R1800
Tina 12A connector block for two units.
For Magne 4 DYN-Info
Accessories
2TLA020072R0200
Urax B1R adapter for connecting to AS-i-bus. A failsafe input node and
three non-failsafe outputs. Connector for local resetting.
AS-i-AUX power supply required. For Magne 4X DYN only
Important!
All installation kits include bolts for fitting on ABB Jokab Safety Quick-Guard®
fencing systems.
A product from Jokab Safety with product code starting with 2TLJ is fully compatible with ABB products with
product codes starting with 2TLA.
Magne 4 incl. Eva sensor and JSM D21B,
JSM D24 plus JSM D27 (closing door)
Product code:
2TLA042023R0500 JSM D21B
2TLA042023R0300 JSM D24
2TLA042023R1000 JSM D27
JSM D28 handle profile in aluminum
for all Magne (sliding door)
Product code:
2TLA042023R0100 JSM D28
Magne 4 incl. Eva sensor and JSM D23 (sliding
door)
Product code:
2TLA042023R0200 JSM D23
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

ABB Magne 4 Series User Instructions

Type
User Instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI