3. Operating principle
Material All the external parts are resistant transformer oils, salt fog and UV rays.
Dial Tempered glass / Polycarbonate
Standard color
Ambient temperature
Oil temperature
Degree of protection
Standard cable gland
Wires
shielded twisted pair cable
Electronic board features, only for eOLI
Power consumption
Distance for analogical output
Distance for digital output
Ventilation Valve
Electronic board features, only for Viewer
Distance for analogical input
Ventilation Valve
3.3 Technical features
3.3.1 Microswitches
Breaking and making capacity
Voltage Uninterrupted current (making capacity) Interrupted current (breaking capacity)
Table 2
3.1 Functioning
The level gauge with magnetic joint is composed of
a sturdy, watertight body made of aluminum alloy
powder coated to protect against corrosion.
The movement of the float rod and the pointer takes
place thanks to magnetic coupling and reaches a
inside the conservator tank the movement of the
float cause the rotation of the magnet joint with
consequent variation of the indication on the dial of
the gauge.
The pointer indicate the level that the oil should
reach at the temperatures printed on the dial.
The electronic version of the oil level gauge provide
an analogical and a digital signal proportional to the
oil level inside the conservator. These signals can be
remote to: PLC, PC, integrated monitoring system,
Remote Indicator.
An electronic level indicator equipped with 4-20 mA
output signal can be coupled with the electronic
Viewer. This device replicate the value of oil level
3.2. Outputs
STANDARD CONFIGURATION
STANDARD
(Comem OLI-
ComemL140)
MICRO-SWITCHES
OPTIONS (Comem eOLI) ANALOG OUTPUT
Table 1