Pelco c561m-h User manual

Category
Video switches
Type
User manual

This manual is also suitable for

Pelco pelco c561m-h is an environmental power supply designed for indoor or outdoor applications and is ideal for use with cameras, domes, and integrated positioning systems. The device has selectable 100/120/240 VAC input power, selectable 24/26/28 VAC output power, and a stainless steel link-lock latch that can be secured with padlock (padlock not provided).

Pelco pelco c561m-h is an environmental power supply designed for indoor or outdoor applications and is ideal for use with cameras, domes, and integrated positioning systems. The device has selectable 100/120/240 VAC input power, selectable 24/26/28 VAC output power, and a stainless steel link-lock latch that can be secured with padlock (padlock not provided).

INSTALLATION/OPERATION
WCS1-4
Environmental
Power Supply
C561M-H (3/08)
C561M-H (3/08) 3
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Installation should be done only by qualified service personnel and conform to all local codes.
6. Use only installation methods and materials capable of supporting four times the maximum
specified load.
7. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
8. Only use attachments/accessories specified by Pelco.
9. Use only with the cart, stand, tripod, bracket, or table specified by Pelco, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from
tip-over.
10. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been
damaged in any way, such as liquid has been spilled or objects have fallen into the apparatus, the
apparatus does not operate normally, or has been dropped.
11. Only use parts recommended by Pelco.
12. Use stainless steel hardware to fasten the enclosure to outdoor surfaces.
13. AN ALL-POLE MAINS SWITCH with a contact separation of at least 3 mm in each pole shall be
incorporated in the electrical installation of the building (permanent 240 VAC product only).
4 C561M-H (3/08)
Description
The WCS1-4 is a single power supply designed for indoor or outdoor applications and is ideal for use with
cameras, domes, and integrated positioning systems such as Spectra
®
and Esprit
®
.
The WCS1-4 power supply has one fused output and is capable of handling up to 4 amps (100 VA) of total
load. The unit features selectable 100/120/240 VAC input power, selectable 24/26/28 VAC output power,
and a stainless steel link-lock latch that can be secured with padlock (padlock not provided).
Installation
MOUNTING INSTRUCTIONS
To mount the power supply directly to a wallboard, wall, or concrete refer to Figure 1 through 3 and do the
following:
1. Remove the retaining screw from the door latch of the WCS1-4 power supply.
2. Open the door of the WCS1-4 power supply, and then remove the plug(s) from the required conduit
hole(s) located on the bottom of the unit. Install 3/4-inch (1.91 cm) conduit fitting(s) (not supplied).
Close the lid to the power supply.
3. Determine the mounting location for the WCS1-4.
4. Use the WCS1-4 power supply as a template and mark the four fastener positions on the mounting
surface.
5. Prepare the holes for installation.
6. Attach the WCS1-4 power supply securely to the mounting surface with four fasteners of
appropriate length. Fasteners between 1/4-inch and 5/16-inch diameter (not supplied) can be used.
Figure 1.
Mounting to Wallboard
Figure 2.
Mounting to Wall
Figure 3.
Mounting to Concrete
WARNING: Under light load conditions and high input power voltage, output voltage from the
WCS1-4 power supply may reach 32 VAC. Pelco recommends that all equipment connected to the
WCS1-4 power supply be rated to handle 32 VAC. Pelco’s Spectra domes and Esprit integrated
positioning systems meet this requirement. Pelco cannot be liable for any damages resulting from
incorrect wiring of the WCS1-4 power supply.
CONDUIT
FITTINGS
CONDUIT
FITTINGS
CONDUIT
FITTINGS
Mounting to Wallboard
Mounting to Wall
MOUNTING HARDWARE WITH
ANCHOR OR TOGGLE BOLT
(NOT SUPPLIED)
Mounting to Concrete
WOOD SCREW
(NOT SUPPLIED)
MOUNTING
HARDWARE
(NOT SUPPLIED)
CONCRETE WALL
WALL
WALLBOARD
DOOR
LATCH
RETAINING
SCREW
DOOR
LATCH
RETAINING
SCREW
DOOR
LATCH
RETAINING
SCREW
C561M-H (3/08) 5
FUSE INSTALLATION
The WCS1-4 power supply is shipped from the factory with a 1.6 A fuse installed for 100/120 VAC input
power. To use input power of 240 VAC, change the 1.6 A fuse to a 500 mA fuse (supplied).
To change the fuse remove the lid to the fuse holder (refer to Figure 4) located inside the power supply and
then install the new fuse. Store extra fuses (supplied) in the spare fuse holders.
INPUT POWER WIRING
To install the input power wires to the WCS1-4 power supply, refer to Figure 4 and do the following:
1. Determine the size of the input wire needed.
2. Bring the wiring into the WCS1-4 through the conduit fitting.
3. Attach the neutral input power wire to the 100 V, 120 V, or 240 V connection on the Primary Line
Input connector strip. Attach the hot wire to the COM connection on the same strip.
4. Attach the input ground wire to the No. 6 ground stud, located between the conduit holes, and then
tighten the wire with the nut and washer (supplied).
WARNING: The WCS1-4 does not have an on/off switch. Turn off power at the circuit breaker
before wiring the power supply.
6 C561M-H (3/08)
OUTPUT WIRING
To install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the
following:
1. Refer to Table A and determine the output connection needed for your camera, dome, or positioning
system. Refer to Figure 4, for the proper connector strip connections.
2. Attach one output wire to either the Tap A (24 VAC), Tap B (26 VAC), or Tap C (28 VAC) connections
on the Secondary Output Tap’s connector strip and attach the second wire to the COM connection on
the same strip. Be sure that you have the proper wiring size and distances installed if you plan to
change connections later.
3. Close the lid to the WCS1-4 power supply, replace the retaining screw to the door latch, and then
turn power on.
Figure 4. Wiring Connector Diagram
120V-F 1.6AH
240V-F 0.5AH
C561M-H (3/08) 7
CABLE CONNECTIONS AND REQUIREMENTS
The following are the recommended maximum distances to wire the WCS1-4 to a Spectra or Esprit
positioning system.
To determine the correct voltage tap:
1. Pick the unit type.
2. Find the wire gauge used (22 gauge is not recommended).
Determine which secondary output tap (A, B, or C) is appropriate for the distance between the dome or
positioning system and the WCS1-4. Distance is in feet (meters).
Maintenance
There are no user-serviceable parts except for the fuse. If the transformer in the WCS1-4 does not work
properly, the entire environmental power supply needs to be returned to the factory for repair. Refer to
Warranty and Return Information located on the inside back cover of this manual for instructions on
returning the WCS1-4.
Clean the outer surface of the WCS1-4 box with a nonabrasive cleaning cloth and antistatic cleaner.
Do not use kerosene or similar substances that may damage the surface.
Table A. Maximum Wiring Distance From Transformer to Load
Power Consumption
(25 VA)
20 AWG
(0.5 mm
2
)
18 AWG
(1.0 mm
2
)
16 AWG
(1.5 mm
2
)
14 AWG
(2.5 mm
2
)
12 AWG
(4.0 mm
2
)
Tap A (24 VAC) 113 (34) 180 (55) 287 (87) 455 (139) 725 (221)
Tap B (26 VAC) 133 (40) 212 (64) 337 (103) 536 (163) 852 (260)
Tap C (28 VAC) 155 (47) 246 (75) 392 (119) 623 (190) 990 (302)
Power Consumption
(50 VA)
20 AWG
(0.5 mm
2
)
18 AWG
(1.0 mm
2
)
16 AWG
(1.5 mm
2
)
14 AWG
(2.5 mm
2
)
12 AWG
(4.0 mm
2
)
Tap A (24 VAC) 56 (17) 90 (27) 143 (43) 228 (69) 362 (110)
Tap B (26 VAC) 66 (20) 105 (32) 168 (51) 268 (81) 425 (129)
Tap C (28 VAC) 77 (23) 122 (37) 195 (59) 311 (94) 493 (150)
Power Consumption
(70 VA)
20 AWG
(0.5 mm
2
)
18 AWG
(1.0 mm
2
)
16 AWG
(1.5 mm
2
)
14 AWG
(2.5 mm
2
)
12 AWG
(4.0 mm
2
)
Tap A (24 VAC) 41 (12) 64 (19) 102 (31) 163 (50) 259 (79)
Tap B (26 VAC) 49 (15) 78 (24) 124 (38) 198 (60) 315 (96)
Tap C (28 VAC) 55 (17) 88 (27) 135 (41) 222 (68) 353 (107)
8 C561M-H (3/08)
Specifications
ELECTRICAL
Input Voltage Selectable 100, 120, 240 VAC, 50/60 Hz through the Primary Line Input
connector strip
Output Voltage/Power Selectable 24 VAC (Tap A), 26 VAC (Tap B), or 28 VAC (Tap C) at 100 VA
through the Secondary Output Tap’s connector strip
Fusing 1 fuse. Select from one of the following supplied fuses:
3, 1.6 A fast-acting fuses (120 VAC)
3, 500 mA fast-acting fuses (240 VAC)
Spare Fuse Holder 2 spare fuse holders (attached to transformer cover)
Required Input Current 1 A
MECHANICAL
Contruction Aluminum
Finish Gray polyester powder coat
Cable Entry 2 hole plugs will accommodate 3/4-inch (1.91 cm) conduit fittings
(not provided) that meet NEMA Type 4X standards.
Mount Method 4, 0.375-inch (0.95 cm) holes on mounting plate.
Latch 1 stainless steel link-lock latch secured with screw; latch also can be
secured with padlock (not supplied)
GENERAL
Environment Indoor/outdoor
Operating Range -50° to 122°F (-45.56° to 50°C)
Weight 6.84 lb (3.10 kg)
(Design and product specifications subject to change without notice.)
C561M-H (3/08) 9
4.01
(10.3)
6.50
(16.5)
7.65
(19.4)
7.32
(18.8)
6.63
(16.8)
6.71
(17.0)
4.50
(11.4)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES.
10 C561M-H (3/08)
REVISION HISTORY
Manual # Date Comments
C561M 11/97 Original version.
C561M-A 12/98 Changed model number. Revised Table A to update vA ratings for Spectra.
5/00 Changed model number.
C561M-B 6/00 Revised manual to support changes required for UL listing.
C561M-C 5/03 Revised Wiring Distance section to include Spectra III and Esprit information. Updated manual to new
format.
C561M-D 11/03 Revised cover photo and Figure 5 to show new conduit hole plug per ECO 01-6947.
C561M-E 8/05 Revised manual per ECO 05-11280 to change input power and a fuse value from 230 VAC to 240 VAC.
C561M-F 8/06 Revised figures 1 through 5 to reflect a new box shape. Revised the weight in the Specifications section.
C561M-G 5/07 Revised Figure 4 to reflect label change. Updated manual to meet department style guidelines.
C561M-H 3/08 Revised input power wiring instructions.
The materials used in the manufacture of this document and its components are compliant to the requirements of
Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with
Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment
(WEEE). Contact your local dealer for procedures for recycling this equipment.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of
shipment.
Exceptions to this warranty are as noted below:
Five years on fiber optic products and TW3000 Series unshielded twisted pair (UTP) transmission products.
Three years on Spectra
®
IV products.
Three years on Genex
®
Series products (multiplexers, server, and keyboard).
Three years on DX Series digital video recorders, DVR5100 Series digital video recorders, DigitalSENTRY
®
Series hardware products, DVX Series
digital video recorders, NVR300 Series network video recorders, and Endura
®
Series distributed network-based video products.
Three years on Camclosure
®
and Pelco-branded fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,
and MC3651H-2X camera models, which have a five-year warranty.
Three years on PMCL200/300/400 Series LCD monitors.
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy
®
, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
Two years on Spectra III
, Spectra Mini, Esprit
®
, ExSite
®
, and PS20 scanners, including when used in continuous motion applications.
Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).
Two years (except lamp and color wheel) on Digital Light Processing (DLP
®
) displays. The lamp and color wheel will be covered for a period of
90 days. The air filter is not covered under warranty.
Two years on Intelli-M
®
eIDC controllers.
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
Six months on all pan and tilts, scanners, or preset lenses used in continuous motion applications (preset scan, tour, and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to a Pelco designated location. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under
this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the
Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or
consequential damages (including loss of use, loss of profit, and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state
to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and
provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if
returned for credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid.
Pelco, the Pelco logo, Camclosure, DigitalSENTRY, Endura, Esprit, ExSite, Genex, Intelli-M, Legacy, and Spectra are registered trademarks of Pelco, Inc.
Spectra III is a trademark of Pelco, Inc. © Copyright 2008, Pelco, Inc. All rights reserved.
DLP is a registered trademark of Texas Instruments Incorporated.
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
www.pelco.com
ISO9001
Australia
|
Finland
|
France
|
Germany
|
Italy
|
Macau
|
The Netherlands
|
Russia
|
Singapore
South Africa
|
Spain
|
Sweden
|
United Arab Emirates
|
United Kingdom
|
United States
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Pelco c561m-h User manual

Category
Video switches
Type
User manual
This manual is also suitable for

Pelco pelco c561m-h is an environmental power supply designed for indoor or outdoor applications and is ideal for use with cameras, domes, and integrated positioning systems. The device has selectable 100/120/240 VAC input power, selectable 24/26/28 VAC output power, and a stainless steel link-lock latch that can be secured with padlock (padlock not provided).

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI