Patton OnSite 2620 Quick start guide

Category
Routers
Type
Quick start guide

This manual is also suitable for

12 SmartNode 5300 Quick Start Guide
NOTES
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
OnSite™ Model 2603 & 2620
WAN Access Router
Quick Start Guide
Important—This is a Class A device and is intended for use in a light industrial environ-
ment. It is not intended nor approved for use in an industrial or residential environment.
Part Number: 07M2620-QS, Rev. F
Revised: March 6, 2014
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: suppor[email protected]
WWW: www.patton.com
2 SmartNode 5300 Quick Start Guide
1.0 Power up the router
Your router comes with one of the following power supply options:
External AC adaptor with included power cord
Internal AC power supply
Internal DC power supply—no power accessories are included
This device contains no user serviceable parts. The equip-
ment shall be returned to Patton Electronics for repairs, or
repaired by qualified service personnel.
Mains Voltage: Do not open the case the when the power
cord is attached. Line voltages are present within the
power supply when the power cords are connected. The
mains outlet that is utilized to power the devise shall be
within 10 feet (3 meters) of the device, shall be easily acces-
sible, and protected by a circuit breaker.
For AC powered units, ensure that the power cable used
meets all applicable standards for the country in which it
is to be installed, and that it is connected to a wall outlet
which has earth ground.
For units with an external power adapter, the adapter shall
be a listed Limited Power Source.
Hazardous network voltages are present in WAN ports
regardless of whether power to the unit is ON or OFF. To
avoid electric shock, use caution when near WAN ports.
When detaching the cables, detach the end away from the
device first.
Do not work on the system or connect or disconnect cables
during periods of lightning activity.
The interconnecting cables shall be acceptable for external use and shall be
rated for the proper application with respect to voltage, current, anticipated
temperature, flammability, and mechanical serviceability.
Use only a 12V certified Limited Power Source external power adaptor
marked LPS.
WARNING
CAUTION
CAUTION
SmartNode 5300 Quick Start Guide 11
NOTES
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
10 SmartNode 5300 Quick Start Guide
NOTES
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
SmartNode 5300 Quick Start Guide 3
1.1 Models with external AC adaptor
1. Connect female plug of the AC power cord to the AC adaptor provided.
2. Connect the barrel-type connector of the AC adaptor to the barrel-type
Power jack on the OnSite router.
3. Insert the male plug of the AC power cord into an AC power outlet (100–240 VAC).
1.2 Models with internal AC power supply
1. Insert the female end of the AC power cord into the internal power supply connector.
2. Connect the male end of the power cord into an AC power outlet (100–240 VAC).
1.3 Models with internal DC power supply
1. Strip insulation 1/4-inch from the electrical wires that will connect the DC power source to the OnSite.
2. Connect the positive (+) terminal from the power source to the positive (+) terminal on the OnSite.
3. Connect the ground terminal from the power source to the ground terminal (E) on the OnSite.
4. Connect the negative (-) terminal from the power source with to the negative (-) terminal on the OnSite.
Figure 1. Connecting the DC power supply
Note +”, “E”, and “-” may be unlabeled.
1.4 Power-up indication
The
Power LED blinks as the OnSite is powering up. When the Power LED stops blinking and remains lit, the
OnSite is ready for you to configure.
2.0 Configure the IP address
The OnSite is shipped with a factory-configured IP address assigned to the Ethernet LAN port (green outline).
The address is
192.168.200.10/24. In most cases, you must change the address to be on the same sub-
net as your PC, as described in the procedures below. If you are not sure which IP address to use for your instal-
lation, contact your network administrator.
2.1 Connecting a PC and logging in
1. Using the included combination RS232/Ethernet cable and DB9-RJ45 adapter, connect a PC’s serial port
to the OnSite’s
Console port (see figure 2).
+E-
4 SmartNode 5300 Quick Start Guide
Figure 2. Connecting OnSite to the PC’s serial port
2. Start a HyperTerminal session on the PC using the settings:
9600 bps, 8 data bits, 1 stop bit, no parity, no flow control
3. Log in to the OnSite using the factory-default login and password:
Login: superuser
Password: superuser
Login successful
2.2 Modifying the IP address
1. Display current IP interface settings for the OnSite
Ethernet LAN port.
ip list interfaces <enter>
IP Interfaces:
ID | Name | IP Address | DHCP | Transport
---|------|----------------|----------|--------------
1 | ip1 | 192.168.200.10 | disabled | <eth1>
----------------------------------------------------
2. Modify the IP address for the LAN port according to your network requirements.
ip set interface ip1 ipaddress 10.10.10.5 255.255.255.0
Note The above IP address (10.10.10.5/24) is only an example. You must choose an IP address on the same
subnet as your PC.
3. Verify the new address is correct and save it in system boot memory.
ip list interfaces <enter>
system config save <enter>
Now you can connect the OnSite to your local IP network and complete the remaining configuration from your
PC using a standard web browser.
Link
Frame
TD
RD
Link
100M
Tx
Rx
WAN
Ethernet
Power
Console
ipLink Gateway
High Speed WAN Access Router
Model 2603
Connect to Console port
Serial port
PC with
terminal emulator
SmartNode 5300 Quick Start Guide 9
Copyright statement
Copyright © 2012, Patton Electronics Company. All rights reserved.
The information in this document is subject to change without notice. Patton Electronics assumes no
liability for errors that may appear in this document.
Trademarks statement
The term
OnSite is a trademark of Patton Electronics Company. All other trademarks presented in this docu-
ment are the property of their respective owners.
Warranty, Trademark, & Compliance Information
For warranty, trademark and compliance information, refer to the Models 2603, 2621, and 2635 OnSite Series
High Speed Routers User Manual available online at www.patton.com/manuals/2600SER.pdf.
In accordance with the requirements of council directive 2002/96/EC on
Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-
life you separate this product from other waste and scrap and deliver to the
WEEE collection system in your country for recycling.
8 SmartNode 5300 Quick Start Guide
B.2 Radio and TV Interference (FCC Part 15)
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in
strict accordance with the manufacturer's instructions—may cause interference to radio and television recep-
tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accor-
dance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable
protection from such interference in a commercial installation. However, there is no guarantee that interference
will not occur in a particular installation. If the equipment causes interference to radio or television reception,
which can be determined by disconnecting the cables, try to correct the interference by one or more of the fol-
lowing measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna,
and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and
receiver are on different branches).
B.3 CE Declaration of Conformity
Product Description: OnSite 2603, 2620
We certify that the apparatus described above conforms to the requirements of Council Directive 2004/108/EC
on the approximation of the laws of the member states relating to electromagnetic compatibility; and Council
Directive 2006/95/EC on the approximation of the laws of the member states relating to electrical equipment
designed for use within certain voltage limits.
The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above
directive is indicated by the CE sign on the device.
The signed Declaration of Conformity can be downloaded from www.patton.com/certifications/.
B.4 Authorized European Representative
D R M Green
European Compliance Services Limited.
Avalon House, Marcham Road
Abingdon,
Oxon OX14 1UD, UK
The safety advises in the documentation accompanying the products shall be
obeyed. The conformity to the above directive is indicated by the CE sign on
the device.
SmartNode 5300 Quick Start Guide 5
3.0 Connect to the local IP network
Connect the OnSite’s (green) Ethernet port to the same Ethernet segment as your PC (see figure 3).
Note The Model 2620 does not have an MDI-X switch, so you must use a cable wired straight-through to con-
nect the Model 2620’s Ethernet port to the IP network.
If you have a Model 2603, press the MDI-X switch until the Ethernet Link LED turns on.
Figure 3. Connecting the OnSite to the local IP network (Model 2603/K shown)
You can check the network connection with the ping command. For example, you would ping 10.10.10.5
from your PC.
4.0 Log onto the web management interface
You will now access the web management Graphical User Interface (GUI) to configure the OnSite using a stan-
dard web browser (such as Internet Explorer or Netscape browser).
1. At your PC, open a web browser and enter the IP address you assigned to the OnSite’s Ethernet LAN port
in step 2 of section 2.2 “Modifying the IP address” on page 4.
2. Log in to the web management home page using the username
superuser and the password supe-
ruser
.
6 SmartNode 5300 Quick Start Guide
Figure 4. OnSite web management home page
3. Now you can use the OnSite’s web management pages to complete your configuration (see section 6.0
“Complete the installation” on page 7).
5.0 Connect the WAN port
The OnSite 2603/T, 2603/K, and 2620 come with a T1/E1 WAN interface (presented on an RJ-48C connector
with selectable line impedances of 100-ohms for T1 and 120-ohms for E1 lines). The Model 2603 has one RJ-
48C connector and the 2620 has two. The Model 2603/K and 2620/KK also come with dual BNC connectors for
alternate connection to unbalanced 75-ohm E1 lines.
To connect the WAN port on a Model 2620 or Model 2603/T, or if you plan to use the RJ-48C port on a 2603/K,
refer to section “Connecting to the RJ-48C WAN port”. Otherwise, refer to section “Connecting to the unbalanced
75-ohm TX and RX WAN ports (Model 2603/K and 2620/KK only)” to install cables onto the BNC connectors on
the 2603/K and 2620/KK models.
Connecting to the RJ-48C WAN port
1. Obtain a twisted-pair cable with an RJ-48C plug connector at each end.
2. Plug one end of the cable into the RJ-48C socket (labeled
WAN ) on the OnSite Router.
3. Plug the other end of the cable into the T1/E1 device.
4. Repeat steps 1 through 3 to install the remaining WAN cables on a Model 2620
Connecting to the unbalanced 75-ohm TX and RX WAN ports (Model 2603/K and 2620/KK only)
1. Obtain a coaxial cable with a BNC connector at each end.
2. Plug one end of the cable into the transmit socket (labeled
TX) on the OnSite Router. Plug the other end
of the cable into the receive port of the E1 device.
3. Plug one end of the cable into the receive socket (labeled
RX) on the OnSite Router. Plug the other end of
the cable into the transmit port of the E1 device.
SmartNode 5300 Quick Start Guide 7
6.0 Complete the installation
To finish configuring your OnSite, and for detailed information about installing, configuring, operating, and trou-
bleshooting, refer to the Models 2603, 2621, and 2635 OnSite Series High Speed Routers User Manual available
online at www.patton.com/manuals/2600SER.pdf.
A.0 Customer and Technical Support
Toll-Free VoIP support: call sip:support@patton.com with a VoIP SIP phone
Online support: www.patton.com
E-mail support: support@patton.com—answered within 1 business day
Telephone support:
Standard: +1 (301) 975-1007 (USA), Monday–Friday: 8:00 am to 5:00 pm EST (1300 to
2200 UTC/GMT)
Alternate: +41 (0)31 985 25 55 (Switzerland), Monday–Friday: 8:00 am to 5:00 pm CET (0900 to 1800
UTC/GMT)
Fax: +1 (253) 663-5693 (USA) or +41 (0)31 985 25 26 (Switzerland)
B Compliance Information
B.1 Compliance
EMC:
FCC Part 15, Class A
EN55022, Class A
EN55024
Safety:
UL60950-1/CSA C22.2 No. 60950-1
IEC/EN 60950-1
AS/NZS 60950-1
PSTN Regulatory:
These devices are not intended for connection to the PSTN.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Patton OnSite 2620 Quick start guide

Category
Routers
Type
Quick start guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI