Contec ATLF-8(FIT)GY Owner's manual

Type
Owner's manual

Contec ATLF-8(FIT)GY is a low-pass filter module dedicated to an insulated analog input module [ADI12-8(FIT)GY]. It can reduce the noise of external signals. This passive filter does not require any power supply and is equipped with an interface connector compatible with the ADI12-8(FIT)GY. The system incorporates a screwless connector plug for easier handling and a 35mm DIN rail mounting mechanism.

Contec ATLF-8(FIT)GY is a low-pass filter module dedicated to an insulated analog input module [ADI12-8(FIT)GY]. It can reduce the noise of external signals. This passive filter does not require any power supply and is equipped with an interface connector compatible with the ADI12-8(FIT)GY. The system incorporates a screwless connector plug for easier handling and a 35mm DIN rail mounting mechanism.

F&eIT Series
Low-Pass-Filter Module
For Analog Input
ATLF-8(FIT)GY
User’s Manual
CONTEC CO.,LTD.
ATLF-8(FIT)GY i
Check Your Package
Thank you for purchasing the CONTEC product.
The product consists of the items listed below.
Check, with the following list, that your package is complete. If you discover damaged or missing
items, contact your retailer.
Product Configuration List
- Module...1
[ATLF-8(FIT)GY]
- Users Manual (this booklet)…1
User's Manual
Module
ATLF-8
CH0
CH1
CH2
CH3
+
AG
+
AG
+
AG
+
AG
CH4
CH5
CH6
CH7
+
AG
+
AG
+
AG
+
AG
User's Manual
ii ATLF-8(FIT)GY
Copyright
Copyright 2004 CONTEC CO., LTD. ALL RIGHTS RESERVED.
No part of this document may be copied or reproduced in any form by any means without prior written
consent of CONTEC CO., LTD.
CONTEC CO., LTD. makes no commitment to update or keep current the information contained in
this document. The information in this document is subject to change without notice.
All relevant issues have been considered in the preparation of this document. Should you notice an
omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD.
Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may
appear in this document or for results obtained by the user as a result of using this product.
Trademarks
F&eIT is a registered trademark of CONTEC CO., LTD. Other company and product names
mentioned herein are generally trademarks or registered trademarks of their respective owners.
ATLF-8(FIT)GY iii
Table of Contents
Check Your Package....................................................................................................................................i
Copyright......................................................................................................................................................ii
Trademarks...................................................................................................................................................ii
Table of Contents.......................................................................................................................................iii
1. Before Using the Product 1
About the Module........................................................................................................................................1
Features.................................................................................................................................................1
Customer Support........................................................................................................................................2
Web Site................................................................................................................................................2
Limited One-Year Warranty.......................................................................................................................2
How to Obtain Service................................................................................................................................2
Liability........................................................................................................................................................2
Safety Precautions.......................................................................................................................................3
Safety Information...............................................................................................................................3
Handling Precautions...........................................................................................................................4
Environment.........................................................................................................................................5
Inspection..............................................................................................................................................5
Storage..................................................................................................................................................5
Disposal.................................................................................................................................................5
2. Module Nomenclature and Settings 7
Nomenclature of Module Components......................................................................................................7
Connecting to the ADI12-8(FIT)GY.........................................................................................................7
3. Connecting to an External Device 9
Interface Connector.....................................................................................................................................9
How to Connect an Interface Connector............................................................................................9
Signal Layout on the Interface Connector.......................................................................................10
Connecting an analog input signal...........................................................................................................11
Example of connecting a differential input......................................................................................11
Example of connecting a current input............................................................................................12
4. System Reference 13
Block Diagram...........................................................................................................................................13
Specifications.............................................................................................................................................14
External Dimensions.................................................................................................................................15
iv ATLF-8(FIT)GY
1 Before Using the Product
ATLF-8(FIT)GY 1
1.
Before Using the Product
This chapter provides information you should know before using the product.
About the
Module
The ATLF-8(FIT)GY is a low-pass filter module dedicated to an insulated analog input module
[ADI12-8(FIT)GY].
The ATLF-8(FIT)GY reduces noise included in external signals.
Please read this manual carefully to configure the system, such as connecting it to external devices.
Features
- Serving as a passive filter which requires no power supply.
- Equipped with an interface connector pin-compatible with the ADI12-8(FIT)GY, allowing
connection to an external device in the same way as the ADI12-8(FIT)GY.
- Capable of being connected easily to the ADI12-8(FIT)GY placed beside only by plugging the
dedicated cable.
- The system incorporates a screwless connector plug that allows you to easily attach and detach
wires without using any special tools.
- Like other F&eIT series products, the module has a 35mm DIN rail mounting mechanism as
standard. A connection to a controller module can be effected on a lateral, stack basis in a unique
configuration, which permits a simple, smart system configuration without the need for a backplane
board.
1 Before Using the Product
2 ATLF-8(FIT)GY
Customer Support
CONTEC provides the following support services for you to use CONTEC products more efficiently
and comfortably.
Web Site
Japanese http://www.contec.co.jp/
English http://www.contec.com/
Chinese http://www.contec.com.cn/
Latest product information
CONTEC provides up-to-date information on products.
CONTEC also provides product manuals and various technical documents in the PDF.
Free download
You can download updated driver software and differential files as well as sample programs available in
several languages.
Note! For product information
Contact your retailer if you have any technical question about a CONTEC product or need its price,
delivery time, or estimate information.
Limited One-Year Warranty
CONTEC F&eIT products are warranted by CONTEC CO., LTD. to be free from defects in material
and workmanship for up to one year from the date of purchase by the original purchaser.
Repair will be free of charge only when this device is returned freight prepaid with a copy of the
original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group office,
from which it was purchased.
This warranty is not applicable for scratches or normal wear, but only for the electronic circuitry and
original products. The warranty is not applicable if the device has been tampered with or damaged
through abuse, mistreatment, neglect, or unreasonable use, or if the original invoice is not included, in
which case repairs will be considered beyond the warranty policy.
How to Obtain Service
For replacement or repair, return the device freight prepaid, with a copy of the original invoice. Please
obtain a Return Merchandise Authorization number (RMA) from the CONTEC group office where you
purchased before returning any product.
* No product will be accepted by the CONTEC group without the RMA number.
Liability
The obligation of the warrantor is solely to repair or replace the product. In no event will the warrantor
be liable for any incidental or consequential damages due to such defect or consequences that arise from
Safety Precautions.
Understand the following definitions and precautions to use the product safely.
1 Before Using the Product
ATLF-8(FIT)GY 3
Safety Precautions
Understand the following definitions and precautions to use the product safely.
Safety Information
This document provides safety information using the following symbols to prevent accidents resulting in
injury or death and the destruction of equipment and resources. Understand the meanings of these
labels to operate the equipment safely.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury or in property damage.
1 Before Using the Product
4 ATLF-8(FIT)GY
Handling Precautions
D
A
N
G
E
R
To avoid electric shock, please do not touch the module with a wet hand.
CAUTION
- Do not modify the module. CONTEC will bear no responsibility for any problems, etc., resulting
from modifying this module.
- Do not use or store the module in a hot or cold place, or in a place that is subject to severe
temperature changes.
(Operating temperature range: 0 to 50°C)
- Do not use or store the module in a place subject to direct sunlight or near a heating device, such as
a stove.
- Do not use or store the module in a dusty or humid place.
- As this module contains precision electronic components, do not use or store it in environments
subject to shock or vibration.
- Protect the module from static electricity when handling it for its operation check, adjustment and
the like as it contains components such as CMOS ICs in its circuitry.
- Be careful not to plug the power or signal cable incorrectly when using the module or performing
its operation check.
- Do not use or store the module near equipment generating a strong magnetic field or radio waves.
- When transporting, carrying, or storing the product, be sure to use the packaging materials used for
its shipment from CONTEC or equivalent materials to prevent it from causing a fault due to
vibration or shock.
- If you notice any strange odor or overheating, please unplug the power cable immediately.
- In the event of an abnormal condition or malfunction, please consult the dealer from whom the
module was purchased.
- Do not open the module casing. CONTEC will disclaim any responsibility for module whose
casing has been opened.
- Do not strike or bend the module. Doing so could damage the module.
- To prevent contact malfunction, please do not touch the metallic pins on the external module
connector.
- Do not connect the device module to the controller module already energized. To avoid
malfunction, please be sure to turn off the control module before connecting the device module to it.
1 Before Using the Product
ATLF-8(FIT)GY 5
Environment
Use this product in the following environment. If used in an unauthorized environment, the module
may overheat, malfunction, or cause a failure.
Operating temperature
0 to 50°C
Operating humidity
10 to 90%RH (No condensation)
Corrosive gases
None
Floating dust particles
Not to be excessive
Inspection
Inspect the product periodically as follows to use it safely.
ATLF-8
CH0
CH1
CH2
CH3
+
AG
+
AG
+
AG
+
AG
CH4
CH5
CH6
CH7
+
AG
+
AG
+
AG
+
AG
-
C
h
e
k
t
h
a
t
t
h
e
v
e
n
t
i
l
a
t
i
o
n
s
l
i
t
h
a
s
n
o
o
b
s
t
u
t
i
o
n
and has no dust or foreign matter adhering.
Storage
When storing this product, keep it in its original packing form.
(1) Put the module in the storage bag.
(2) Wrap it in the packing material, then put it in the box.
(3) Store the package at room temperature at a place free from direct sunlight, moisture, shock,
vibration, magnetism, and static electricity.
Disposal
When disposing of the product, follow the disposal procedures stipulated under the relevant laws and
municipal ordinances.
1 Before Using the Product
6 ATLF-8(FIT)GY
2 Module Nomenclature and Settings
ATLF-8(FIT)GY 7
2.
Module Nomenclature and Settings
Nomenclature of Module Components
Figure 2.1 shows the names of module components.
Interface connector
ATLF-8
CH0
CH1
CH2
CH3
+
AG
+
AG
+
AG
+
AG
CH4
CH5
CH6
CH7
+
AG
+
AG
+
AG
+
AG
Connection cable
Figure 2.1. Names of Module Components
Connecting to the ADI12-8(FIT)GY
Connect the ATLF-8(FIT)GY to the ADI12-8(FIT)GY using the stack connectors on their side faces.
For details, refer to the ADI12-8(FIT)GY manual.
Next, connect the connection cable of ATLF-8(FIT)GY to the interface connector of
ADI12-8(FIT)GY.
ATLF-8
CH0
CH1
CH2
CH3
+
AG
+
AG
+
AG
+
AG
CH4
CH5
CH6
CH7
+
AG
+
AG
+
AG
+
AG
ADI12-8
Device
ID
CH0
CH1
CH2
CH3
+
AG
+
AG
+
AG
+
AG
CH4
CH5
CH6
CH7
+
AG
+
AG
+
AG
+
AG
0
4
0
4
6
2
5
1
3
7
RUN STATUS
Connection cable
ADI12-8(FIT)GY
Interface connector
Figure 2.2. Connecting to the ADI12-8(FIT)GY
2 Module Nomenclature and Settings
8 ATLF-8(FIT)GY
3 Connecting to an External Device
ATLF-8(FIT)GY 9
3.
Connecting to an External Device
Interface Connector
How to Connect an Interface Connector
When connecting the Module to an external device, you can use the supplied connector plug.
When wiring the Module, strip off approximately 7 to 8 mm of the covering for the cable, and insert the
bare wire by pressing the orange button on the connector plug. Releasing the orange button after the
wire is inserted to fix the cable.
7 to 8mm
ATLF-8
CH0
CH1
CH2
CH3
+
AG
+
AG
+
AG
+
AG
CH4
CH5
CH6
CH7
+
AG
+
AG
+
AG
+
AG
- Connector used:
2.5mm pitch, 12-pin type, 4.0A rated current
MC0.5/12-G-2.5 [made by Phoenix Contact Corp.]
- Compatible plug:
Front-operable spring gauge type
FK-MC0. 5/12-ST-2.5 [made by Phoenix Contact Corp.]
Compatible cable: AWG28-20
Press this section to insert
the wire material.
Figure 3.1. Connecting an Interface Connector and Connectors That Can Be Used
CAUTION
Removing the connector plug by grasping the cable can break the wire.
3 Connecting to an External Device
10 ATLF-8(FIT)GY
Signal Layout on the Interface Connector
The Module can be connected to an external device using a 12-pin connector that is provided on the
Module face.
12
11
10
9
8
7
6
5
4
3
2
1
CH0 [+]
CH0 [-]
AG
CH1 [+]
CH1 [-]
AG
CH2 [+]
CH2 [-]
AG
CH3 [+]
CH3 [-]
AG
Channel 0ch [+]
Channel 0ch [-]
Analog ground
Channel 1ch [+]
Channel 1ch [-]
Analog ground
Channel 2ch [+]
Channel 2ch [-]
Analog ground
Channel 3ch [+]
Channel 3ch [-]
Analog ground
CH0
CH1
CH2
CH3
12
11
10
9
8
7
6
5
4
3
2
1
CH4 [+]
CH4 [-]
AG
CH5 [+]
CH5 [-]
AG
CH6 [+]
CH6 [-]
AG
CH7 [+]
CH7 [-]
AG
Channel 4ch [+]
Channel 4ch [-]
Analog ground
Channel 5ch [+]
Channel 5ch [-]
Analog ground
Channel 6ch [+]
Channel 6ch [-]
Analog ground
Channel 7ch [+]
Channel 7ch [-]
Analog ground
CH4
CH5
CH6
CH7
Figure 3.2. Signal Layout on the Interface Connector
3 Connecting to an External Device
ATLF-8(FIT)GY 11
Connecting an analog input signal
Example of connecting a differential input
This section gives examples of connections using a flat cable and a shielded cable.
The following figure shows an example of flat cable connection.
For each analog input channel, connect the "+" input to the signal and connect the "-" input to the signal
source ground. Also connect the analog ground on the ATLF-8(FIT)GY to the signal source ground.
Analog Input 0[+]..7[+]
Analog Ground
Cable Signal Source
Analog Input 0[-]..7[-]
Connector
ATLF-8(FIT)GY
Figure 3.3. Differential Input Connection (Flat Cable)
The following figure shows an example of 2-wire shielded cable connection. Use shielded cable if the
distance between the signal source and the ATLF-8(FIT)GY is long or if you want to provide better
protection from noise. For each analog input channel, connect the "+" input to the signal and connect
the "-" input to the signal source ground. Also connect the analog ground on the ATLF-8(FIT)GY and
the signal source ground to the shielding.
Analog Input 0[+]..7[+]
Analog Ground
Signal Source
Analog Input 0[-]..7[-]
Shield cable
Connector
ATLF-8(FIT)GY
Figure 3.4. Differential Input Connection (Shield Cable)
CAUTION
- Connecting the ATLF-8(FIT)GY to the ADI12-8(FIT)GY may cause an error in data converted by
the ADI12-8(FIT)GY.
- When the ADI12-8(FIT)GY inputs two or more signals, crosstalk may occur between the channels.
- A long connection cable may prevent the module from performing analog input correctly. The
connection cable should be as short as possible.
- If the connection cable is affected by noise, the analog input can be inaccurate. Route the
connection cable apart from noise sources.
- The analog signal input to the [+] and [-] inputs must not exceed the maximum input voltage with
reference to the analog ground of the ATLF-8(FIT)GY. Exceeding the input voltage can damage
the module.
- Converted data is undefined when either of the [+] and [-] input terminals is left unconnected.
Connect both of the [+] and [-] input terminals of the channel not connected to the signal source to
the analog ground.
3 Connecting to an External Device
12 ATLF-8(FIT)GY
Example of connecting a current input
To measure a current using the ATLF-8(FIT)GY, you need to convert the current into a voltage using a
resistor.
By connecting a 250
resistor between the [+] and [-] inputs, the ATLF-8(FIT)GY can measure
currents from a 0-20 mA current output device in a voltage input range from 0 to 5 volts. Note that, if
the inserted resistor has a considerable error, it adversely affects converted data, preventing accurate
measurement. You should therefore use a precision resistor (
±
0.1 %) on the connector side.
Note also that, when there are more than one current source, no potential difference must exist between
their respective GND points.
This is because the input channels of the ATLF-8(FIT)GY are not insulated from each other and share
the same analog ground. If an affecting potential difference exists between the channels, insert an
insulator such as an insulating transducer between the channels.
Analog Input 0[+]...7[+]
Analog Ground
Cable Signal Source
Analog Input 0[-]...7[-]
Connector
I
ATLF-8(FIT)GY
Figure 3.5. Current input connection
CAUTION
- If the connection cable is affected by noise, the analog input can be inaccurate. Route the
connection cable apart from noise sources.
- The analog signal input to the [+] and [-] inputs must not exceed the maximum input voltage with
reference to the analog ground of the ATLF-8(FIT)GY. Exceeding the input voltage can damage
the module.
- Converted data is undefined when either of the [+] and [-] input terminals is left unconnected.
Connect both of the [+] and [-] input terminals of the channel not connected to the signal source to
the analog ground.
4 System Reference
ATLF-8(FIT)GY 13
4.
System Reference
Block Diagram
Stack Connector
Stack Interface Connector CH0 to CH3 Interface Connector CH4 to CH7
Low Pass Filter Low Pass Filter Low Pass Filter Low Pass Filter
To ADI12-8(FIT)GY
CH0 to CH3
To ADI12-8(FIT)GY
CH4 to CH7
Figure 4.1. Circuit Block Diagram
R
C
R
AG
CH0[-]
CH0[+]
R R
R
R
C C
R
To ADI12-8(FIT)GY
Figure 4.2. Filter circuit (CH0 extracted)
4 System Reference
14 ATLF-8(FIT)GY
Specifications
Table 4.1. Functional specification
Item Specifications
Input range -10V to +10V
Maximum input voltage ±20V
Input impedance 1M (Min.)
Input channel Differential input 8 channel
Tolerance ±0.2% of FSR
Filter cutoff frequency 10Hz (Typ.)
External dimensions (mm) 50.4(W) x 64.7(D) x 94.0(H) (exclusive of protrusions)
Weight of the module itself 105g
Module installation method
One-touch connection to 35mm DIN rails
(standard connection mechanism provided in the system)
Applicable wire size
AWG28 to 20 wire type: 0.08 to 0.51mm
Connector
FK-MC 0.5/12-ST-2.5 (made by Phoenix Contact Corp.)
2.5mm-pitch, rated current: 4A (Max.)
Table 4.2. Installation Environment Requirements
Item Requirement description
Operating temperature 0 to 50°C
Storage temperature -10 to 60°C
Operating humidity 10% to 90%RH (No condensation)
Floating dust particles Not to be excessive
Corrosive gases None
4 System Reference
ATLF-8(FIT)GY 15
External Dimensions
(1.2)(1.2)
[mm]
94.0
ATLF-8
CH0
CH1
CH2
CH3
+
AG
+
AG
+
AG
+
AG
CH4
CH5
CH6
CH7
+
AG
+
AG
+
AG
+
AG
64.7 4.025.23.5
14.0
35.0
45.0
14
31.5
Figure 4.3. External Dimensions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Contec ATLF-8(FIT)GY Owner's manual

Type
Owner's manual

Contec ATLF-8(FIT)GY is a low-pass filter module dedicated to an insulated analog input module [ADI12-8(FIT)GY]. It can reduce the noise of external signals. This passive filter does not require any power supply and is equipped with an interface connector compatible with the ADI12-8(FIT)GY. The system incorporates a screwless connector plug for easier handling and a 35mm DIN rail mounting mechanism.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI