Contec AO-1604L-LPE, AI-1616L-LPE, AIO-160802L-LPE Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Contec AO-1604L-LPE Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PC-HELPER
High-Resolution Analog
I/O Board for PCI Express Low Profile
AIO-160802L-LPE
High-Resolution Analog
Input Board for PCI Express Low Profile
AI-1616L-LPE
High-Resolution Analog
Output Board for PCI Express Low Profile
AO-1604L-LPE
Users Guide
CONTEC CO., LTD.
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
i
Check Your Package
Thank you for purchasing the CONTEC product.
The product consists of the items listed below.
Check, with the following list, that your package is complete. If you discover damaged or missing
items, contact your retailer.
Product Configuration List
- Board (One of the following) …1
[AIO-160802L-LPE, AI-1616L-LPE or AO-1604L-LPE]
- First step guide …1
- Disk *1 [API-PAC(W32)] …1
- Standard size bracket …1
- Warranty Certificate …1
- Serial Number Label …1
*1 The bundled disk contains the driver software and User’s Guide (this guide)
Standard size
bracket
Board
First step guide
Serial Number Label
Warranty Certificate
Disk
[API-PAC(W32)]
ii
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
Copyright
Copyright 2006 CONTEC CO., LTD. ALL RIGHTS RESERVED
No part of this document may be copied or reproduced in any form by any means without prior written
consent of CONTEC CO., LTD.
CONTEC CO., LTD. makes no commitment to update or keep current the information contained in
this document. The information in this document is subject to change without notice.
All relevant issues have been considered in the preparation of this document. Should you notice an
omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD.
Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may
appear in this document or for results obtained by the user as a result of using this product.
Trademarks
MS, Microsoft, Windows and Windows NT are trademarks of Microsoft Corporation. Other brand and
product names are trademarks of their respective holder.
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
iii
Table of Contents
Check Your Package ................................................................................................................................... i
Copyright ..................................................................................................................................................... ii
Trademarks .................................................................................................................................................. ii
Table of Contents ....................................................................................................................................... iii
1. BEFORE USING THE PRODUCT 1
About the Product ....................................................................................................................................... 1
Features ................................................................................................................................................. 1
Support Software ................................................................................................................................. 2
Cable & Connector (Option) ............................................................................................................. 3
Accessories (Option) .......................................................................................................................... 3
Customer Support ....................................................................................................................................... 4
Web Site ............................................................................................................................................... 4
Limited Three-Years Warranty ................................................................................................................. 4
How to Obtain Service ............................................................................................................................... 4
Liability ........................................................................................................................................................ 4
Safety Precautions....................................................................................................................................... 5
Safety Information ............................................................................................................................... 5
Handling Precautions .......................................................................................................................... 6
Environment ......................................................................................................................................... 7
Inspection ............................................................................................................................................. 7
Storage .................................................................................................................................................. 7
Disposal ................................................................................................................................................ 7
2. SETUP 9
What is Setup?............................................................................................................................................. 9
Using the product under Windows Using the Driver Library API-PAC(W32)............................ 9
Using the product under Windows Using Software Other than the Driver Library API-
PAC(W32) ............................................................................................................................................ 9
Using the Product under an OS Other than Windows ................................................................... 10
Step 1 Installing the Software.................................................................................................................. 11
Which Driver to Use ......................................................................................................................... 11
Starting the Install Program.............................................................................................................. 12
Step 2 Setting the Hardware .................................................................................................................... 14
Replacing the Bracket ....................................................................................................................... 14
Parts of the Product and Factory Defaults ...................................................................................... 15
Setting the Product ID ....................................................................................................................... 15
Plugging the Product ......................................................................................................................... 16
Step 3 Installing the Hardware ................................................................................................................ 17
Turning on the PC ............................................................................................................................. 17
iv
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
Using the API-AIO(WDM) ................................................................................................................ 17
Step4 Initializing the Software ................................................................................................................ 19
Step 5 Checking Operations with the Diagnosis Program ................................................................... 21
What is the Diagnosis Program?...................................................................................................... 21
Check Method .................................................................................................................................... 21
Using the Diagnosis Program .......................................................................................................... 22
Setup Troubleshooting ............................................................................................................................. 25
Symptoms and Actions ..................................................................................................................... 25
If your problem cannot be resolved ................................................................................................. 25
3. EXTERNAL CONNECTION 27
How to connect the connectors ............................................................................................................... 27
Connector shape ................................................................................................................................ 27
Connector Pin Assignment ............................................................................................................... 28
Analog Input Signal Connection ............................................................................................................. 32
Single-ended Input ............................................................................................................................ 32
Analog Output Signal Connection .......................................................................................................... 33
Digital I/O signals, Counter signals and Control signals Connection ................................................ 34
4. FUNCTIONS 35
Analog Input Function ............................................................................................................................. 35
1. Setting the Conversion Conditions.............................................................................................. 36
2. Starting/Stopping Operation ........................................................................................................ 43
3. Monitoring the Status and Acquiring Data ................................................................................ 44
4.Reset ................................................................................................................................................ 47
Analog Output Function........................................................................................................................... 48
1. Setting the Conversion Conditions.............................................................................................. 49
2. Starting/Stopping Operation ........................................................................................................ 56
3. Monitoring the Status and Acquiring Data ................................................................................ 57
4.Reset ................................................................................................................................................ 57
Counter Function ...................................................................................................................................... 58
1. Setting the Operating Conditions ................................................................................................ 58
2. Starting/Stopping Operation ........................................................................................................ 59
3. Monitoring the Status and Acquiring Data ................................................................................ 59
4.Reset ................................................................................................................................................ 60
Digital Input Function .............................................................................................................................. 61
Digital Output Function ........................................................................................................................... 62
5. ABOUT SOFTWARE 63
Bundled disk Directory Structure ........................................................................................................... 63
About Software for Windows .................................................................................................................. 64
Accessing the Help File .................................................................................................................... 64
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
v
Using Sample Programs.................................................................................................................... 65
Usage of Utility Program .................................................................................................................. 68
Uninstalling the Driver Libraries ..................................................................................................... 73
About Software for Linux ........................................................................................................................ 74
Driver Software Install Procedure ................................................................................................... 74
Accessing the Help File .................................................................................................................... 75
Using Sample Programs.................................................................................................................... 75
Uninstalling the driver ...................................................................................................................... 75
6. ABOUT HARDWARE 77
For detailed technical information .......................................................................................................... 77
Hardware specification ............................................................................................................................. 78
Block Diagram .......................................................................................................................................... 82
Control Signal Timings ............................................................................................................................ 85
Control Signal Timings for Analog Input ....................................................................................... 85
Control Signal Timings for Analog Output .................................................................................... 86
Control Signal Timings for Counter ................................................................................................ 87
About Calibration ..................................................................................................................................... 88
vi
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
1. Before Using the Product
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
1
1.
Before Using the Product
About the Product
This product is a multi-function, PCI Express bus-compliant interface board that incorporates
high-precision 16-bit analog inputs, high-precision 16-bit analog outputs, digital inputs/outputs
(LVTTL level each 4ch), and a counter (32-bit, 1ch) function.
This product supports a Low Profile size slot and, if replaced with the supplied bracket, supports a
standard size slot, too.
You can use the driver library (API-PAC(W32)) supplied with the board to write Windows application
programs in any programming language (such as Visual Basic, Visual C++, etc.) that supports the
calling of Win32 API functions.
It can also collect data easily without a program when the data logger software [C-LOGGER] stored
on the bundled disk is used.
With plug-ins for the dedicated libraries, the board also supports MATLAB and LabVIEW.
Features
Multi-function
High-precision analog I/O can be implemented in a compact system. The series consists of three
different models from which you can select the best model to suit your application.
The < AIO-160802L-LPE > contains the analog input (16bit, 8ch), analog output (16bit, 2ch).
The < AI-1616L-LPE > contains the analog input (16bit, 16ch).
The < AO-1604L-LPE > contains the analog output (16bit, 4ch).
All three models include digital inputs and outputs (4 each, LVTTL level) and a counter (32-bit 1ch).
Analog I/O can be synchronized with an internal timer or external clock.
Analog I/O can both be performed at fixed time intervals or synchronized with an external signal.
Buffer memory available for background processing independent of software
The boards include buffer memory (1K Word each for analog input and output) which can be used in
either FIFO or ring format. This allows analog I/O to be performed independently of the operating
state of the PC or software.
Software-based calibration function
Calibration of analog input/output can be all performed by software. Apart from the adjustment
information prepared before shipment, additional adjustment information can be stored according to
the use environment.
Filter function for easy connection of external signals
The digital input signals, counter input signals, and the external control signals for analog I/O
incorporate a digital filter to prevent problems such as chattering.
Support for both of Low Profile and standard size slots
Support for both of Low Profile and standard size slots (interchangeable with a bundled bracket).
Supported to the data logger software [C-LOGGER] (Analog input only)
Supporting the data logger software [C-LOGGER] that enables the graph display of recorded signal
data, file saving, and dynamic transfer to the spreadsheet software program “Excel”.
1. Before Using the Product
2
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
Plug-ins for the dedicated libraries, the board also supports MATLAB and LabVIEW.
We offer a dedicated library [ML-DAQ], which allows you to use this product on MATLAB by The
MathWorks as well as another dedicated library [VI-DAQ], which allows you to use the product on
LabVIEW.
These dedicated libraries are available, free of charge (downloadable), on our web site.
Support Software
You should use CONTEC support software according to your purpose and development environment.
Windows version of analog I/O driver
API-AIO(WDM)
[Stored on the bundled disk driver library API-PAC(W32)]
The API-AIO(WDM) is the Windows version driver library software that provides products in the form of Win32
API functions (DLL). Various sample programs such as Visual Basic and Visual C++, etc and diagnostic program
*1useful for checking operation is provided.
For more details on the supported OS, applicable language and new information, please visit the CONTECs Web
site.
Linux version of analog I/O driver
API-AIO(LNX)
[Stored on the bundled disk driver library API-PAC(W32)]
The API-AIO(LNX) is the Linux version driver software which provides device drivers (modules) by shared library
and kernel version. Various sample programs of gcc are provided.
For more details on the supported OS, applicable language and new information, please visit the CONTECs Web
site.
Data Logger Software
C-LOGGER
[Stored on the bundled disk driver library API-PAC(W32)]
C-LOGGER is a data logger software program compatible with our analog I/O products. This program enables the
graph display of recorded signal data, zoom observation, file saving, and dynamic transfer to the spreadsheet
software Excel. No troublesome programming is required.
For more details on the supported OS, applicable language and new information, please visit the CONTECs Web
site.
Data Acquisition library for MATLAB
ML-DAQ
(Available for downloading (free of charge) from the CONTEC web site.)
This is the library software which allows you to use our analog I/O device products on MATLAB by the
MathWorks. Each function is offered in accordance with the interface which is integrated in MATLABs Data
Acquisition Toolbox.
For more details on the supported OS, applicable language and new information, please visit the CONTECs Web
site.
1. Before Using the Product
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
3
Data acquisition VI library for LabVIEW
VI-DAQ
(Available for downloading (free of charge) from the CONTEC web site.)
This is a VI library to use in National Instruments LabVIEW.
VI-DAQ is created with a function form similar to that of LabVIEW's Data Acquisition VI, allowing you to use
various devices without complicated settings.
For more details on the library and download of VI-DAQ, please visit the CONTECs Web site.
Cable & Connector (Option)
Shield Cable with Two 50-Pin Mini-Ribbon Connector
: PCB50PS-0.5P (0.5m)
: PCB50PS-1.5P (1.5m)
Shield Cable with One 50-Pin Mini-Ribbon Connector
: PCA50PS-0.5P (0.5m)
: PCA50PS-1.5P (1.5m)
Accessories (Option)
Screw Terminal Unit(M3 terminal block, 50 points) : EPD-50A *1
Buffer Amplifier Box for Analog Input Boards (8ch type) : ATBA-8L *1*2*3*4
Buffer Amplifier Box for Analog Input Boards (16ch type) : ATBA-16L *1*2*3
BNC Connector Screw Terminal Unit : ATP-8L *1*5
*1 PCB50PS-0.5P or PCB50PS-1.5P optional cable is required separately.
*2 Only AIO-160802L-LPE, AI-1616L-LPE can be used.
*3 An external power supply is necessary (optional AC adaptor POA200-20 prepared.)
*4 As for the AI-1616L-LPE, capable of using the analog input of up to 8ch.
*5 Capable of using the analog input of up to 8ch, and analog output of up to 2ch.
* Check the CONTECs Web site for more information on these options.
1. Before Using the Product
4
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
Customer Support
CONTEC provides the following support services for you to use CONTEC products more efficiently
and comfortably.
Web Site
https://www.contec.com/
Latest product information
CONTEC provides up-to-date information on products.
CONTEC also provides product manuals and various technical documents in the PDF.
Free download
You can download updated driver software and differential files as well as sample programs available
in several languages.
Note! For product information
Contact your retailer if you have any technical question about a CONTEC product or need its price,
delivery time, or estimate information.
Limited Three-Years Warranty
CONTEC products are warranted by CONTEC CO., LTD. to be free from defects in material and
workmanship for up to three years from the date of purchase by the original purchaser.
Repair will be free of charge only when this device is returned freight prepaid with a copy of the
original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group
office, from which it was purchased.
This warranty is not applicable for scratches or normal wear, but only for the electronic circuitry and
original products. The warranty is not applicable if the device has been tampered with or damaged
through abuse, mistreatment, neglect, or unreasonable use, or if the original invoice is not included, in
which case repairs will be considered beyond the warranty policy.
How to Obtain Service
For replacement or repair, return the device freight prepaid, with a copy of the original invoice. Please
obtain a Return Merchandise Authorization number (RMA) from the CONTEC group office where
you purchased before returning any product.
* No product will be accepted by CONTEC group without the RMA number.
Liability
The obligation of the warrantor is solely to repair or replace the product. In no event will the
warrantor be liable for any incidental or consequential damages due to such defect or consequences
that arise from inexperienced usage, misuse, or malfunction of this device.
1. Before Using the Product
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
5
Safety Precautions
Understand the following definitions and precautions to use the product safely.
Safety Information
This document provides safety information using the following symbols to prevent accidents resulting
in injury or death and the destruction of equipment and resources. Understand the meanings of these
labels to operate the equipment safely.
DANGER indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury or in property damage.
DANG
ER
WARNING
C
AU
TION
1. Before Using the Product
6
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
Handling Precautions
Do not use the product where it is exposed to flammable or corrosive gas. Doing so may result in
an explosion, fire, electric shock, or failure.
- There are switches and jumpers on the product that need to be set in advance.
Be sure to check these before installing the expansion slot.
- Only set the switches and jumpers on the product to the specified settings.
Otherwise, the product may malfunction, overheat, or cause a failure.
- Do not strike or bend the product.
Otherwise, the product may malfunction, overheat, cause a failure or breakage.
- Do not touch the product's metal plated terminals (edge connector) with your hands.
Otherwise, the product may malfunction, overheat, or cause a failure.
If the terminals are touched by someone's hands, clean the terminals with industrial alcohol.
- Do not plug or unplug the cables which are connected to the board while the PC or expansion unit
is still turned on.
Otherwise, the board may malfunction, overheat, or cause a failure.
Be sure that the personal computer power is turned off.
- Make sure that your PC or extension unit can supply ample power to all the products installed.
Insufficiently energized products could malfunction, overheat, or cause a failure.
- The specifications of this product are subject to change without notice for enhancement and quality
improvement.
Even when using the product continuously, be sure to read the manual and understand the contents.
- Do not modify the product. CONTEC will bear no responsibility for any problems, etc., resulting
from modifying this product.
- Regardless of the foregoing statements, CONTEC is not liable for any damages whatsoever
(including damages for loss of business profits) arising out of the use or inability to use this
CONTEC product or the information contained herein.
- Regarding “CE EMC Directive Notice”.
Please connect the Interface Connector with a shielded cable to meet the mentioned standard
above.
DA
NGER
CAUTION
1. Before Using the Product
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
7
Environment
Use this product in the following environment. If used in an unauthorized environment, the product
may overheat, malfunction, or cause a failure.
Operating temperature
0 - 50°C
Operating humidity
10 - 90%RH (No condensation)
Corrosive gases
None
Floating dust particles
Not to be excessive
Inspection
Inspect the product periodically as follows to use it safely.
Storage
When storing this product, keep it in its original packing form.
(1) Put the product in the storage bag.
(2) Wrap it in the packing material and then put it in the box.
(3) Store the package at room temperature at a place free from direct sunlight, moisture, shock,
vibration, magnetism, and static electricity.
Disposal
When disposing of the product, follow the disposal procedures stipulated under the relevant laws and
municipal ordinances.
- C
he
ck
that t
he bus
connecto
r
o
f
th
e boa
rd and i
ts cable
have
bee
n
plugged
corr
ectly.
-
Che
ck
tha
t t
he
boa
rd h
as
n
o
dus
t o
r f
or
eig
n m
at
ter
adh
eri
ng
.
- Th
e gold-
plat
ed le
ads
of
the b
us c
onnect
or
have
no st
ain
or c
or
rosi
on.
1. Before Using the Product
8
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
2. Setup
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
9
2.
Setup
This chapter explains how to set up the product.
What is Setup?
Setup means a series of steps to take before the product can be used.
Different steps are required for software and hardware.
The setup procedure varies with the OS and applications used.
Using the product under Windows
Using the Driver Library API-PAC(W32)
This section describes the setup procedure to be performed before you can start developing application
programs for the product using the bundled diskDriver Library API-PAC(W32).
Taking the following steps sets up the software and hardware. You can use the diagnosis program
later to check whether the software and hardware function normally.
Step 1 Installing the Software
Step 2 Setting the Hardware
Step 3 Installing the Hardware
Step 4 Initializing the Software
Step 5 Checking Operations with the Diagnosis Program
If Setup fails to be performed normally, see the Setup Troubleshootingsection at the end of this
chapter.
Using the product under Windows
Using Software Other than the Driver Library API-PAC(W32)
For setting up software other than API-PAC(W32), refer to the manual for that software. See also the
following parts of this manual as required.
This chapter Step 2 Setting the Hardware
This chapter Step 3 Installing the Hardware
Chapter 3 External Connection
Chapter 6 About Hardware
2. Setup
10
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
Using the Product under an OS Other than Windows
For using the product under Linux, see the following parts of this manual.
This chapter Step 2 Setting the Hardware
Chapter 3 External Connection
Chapter 5 About Software
Chapter 6 About Hardware
For using the product under an OS other than Windows and Linux, see the following parts of this
manual.
This chapter Step 2 Setting the Hardware
Chapter 3 External Connection
Chapter 6 About Hardware
2. Setup
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
11
Step 1 Installing the Software
This section describes how to install the Driver libraries.
Before installing the hardware on the PC, install the driver library from the
bundled disk
provided with the product.
The following description assumes the operating system as Windows XP. Although some user
interfaces are different depending on the OS used, the basic procedure is the same.
Which Driver to Use
CONTEC has two analog I/O drivers: “API-AIO(WDM)” and API-AIO(98/PC)”
API-AIO(WDM) is a new driver for analog I/O under Windows.
This driver was developed to be easier to use and to provide additional functions above those provided
by the previous API-AIO(98/PC) driver.
Please use the API-AIO(WDM) with this product. API-AIO(98/PC) is not supported.
2. Setup
12
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
Starting the Install Program
(1)
Load the bundled disk [API-PAC(W32)] on your PC.
(2)
The API-PAC(W32) Installer window appears automatically.
If the panel does not appear, run (drive letter):\AUTORUN.exe.
(3)
Click on the [Install Development or Execution Environment] button.
Before installing the software in Windows Vista, XP, XP, Server 2003, 2000, log in as a user with
administrator privileges.
CAUTION
2. Setup
AIO-160802L-LPE, AI-1616L-LPE, AO-1604L-LPE
13
Selecting API-AIO(WDM)
(1)
The following dialog box appears to select Driver to install and Install option, Usage of
driver library”.
(2)
Select the "Advanced Analog I/O driver".
(3)
Click on the [Install] button.
* Clicking the [Details] button displays detailed information about API-AIO(WDM) and
API-AIO(98/PC).
Run the installation
(1)
Complete the installation by following the instructions on the screen.
(2) The Readme file appears when the installation is complete.
You have now finished installing the software.
/