Sytech SYAC700 Owner's manual

Category
Mobile air conditioners
Type
Owner's manual

Sytech SYAC700 is a portable air conditioner that provides cooling, dehumidification, and fan-only functions. It is suitable for both home and office use.

Capabilities:

  • Cooling: Cools the air in a room to a temperature between 16°C and 30°C.
  • Dehumidification: Removes excess moisture from the air, creating a more comfortable environment.
  • Fan-only: Circulates the air in a room without cooling or dehumidifying it.

Features:

  • Two fan speeds: Choose between high and low fan speeds to adjust the airflow.
  • 24-hour programmable timer: Set the unit to turn on or off at specific times.

Sytech SYAC700 is a portable air conditioner that provides cooling, dehumidification, and fan-only functions. It is suitable for both home and office use.

Capabilities:

  • Cooling: Cools the air in a room to a temperature between 16°C and 30°C.
  • Dehumidification: Removes excess moisture from the air, creating a more comfortable environment.
  • Fan-only: Circulates the air in a room without cooling or dehumidifying it.

Features:

  • Two fan speeds: Choose between high and low fan speeds to adjust the airflow.
  • 24-hour programmable timer: Set the unit to turn on or off at specific times.
Welcome
Thank you for purchasing the new Portable Air Condition SY-AC700. Read this
instruction booklet carefully in order to benefit fully from this product. Store the user
manual in a safe place for future reference.
Important Safeguards
Please read the Manual carefully before operating the machine
ELECTRICAL CONNECTIONS:
Before plugging the appliance into the socket, check that:
. The voltage corresponds to the value indicated on the rating plate
that is located on the back of the appliance.
. The power socket and the electrical circuit are suitable for the
device.
. The socket matches the plug. If not, have the plug replaced.
. The power outlet is properly grounded. Failure to comply with these
instructions
exempts the manufacturer from all liability.
The appliance is for indoor use only.
Place the air conditioner on a fat surface and keep it placed vertically to ensure the
normal operation of its compressor.
This appliance is for domestic use only and not for commercial use.
Before inserting the mains plug into the socket, check that the mains supply voltage
and current rating corresponds with the power supply details shown on the rear
specification plate of the unit.
Read all instructions, Rated Power Supply: Please connect the unit with Grounded
Power source: 220-240VAC, 50HZ.
Disconnect the power plug before dismantling, assembling or before cleaning.
Avoid touching mobile parts of the appliance.
Never insert fingers, pencils or any other objects though the guard whenever the
power plug is connected, especially while running.
Persons (including children) with reduced physical, sensory or mental capabilities
or lack of experience and knowledge do not intend this appliance for use, unless
a person responsible for their safety has given them supervision or instruction
concerning use of the appliance
The appliance is not intended for use by young children or infirm persons unless
they have been adequately supervised by a responsible person to ensure that
they can use the unit safely.
Young children should be supervised to ensure that they do not play with the
appliance.
Do not use the appliance for any other purposes than its intended use.
The appliance must not be used if the guards are not fasten according to the
instructions.
When the power cord is damaged, it must be replaced by the manufacturer or its
service agent or a similar qualified person in order to avoid hazard
Do not use your appliance with an extension cord unless it has been checked
and tested by a qualified electrician or electrical supplier
In the case of any malfunction, return to an authorized service agent. Never open the
unit and try to repair it by yourself.
The air conditioner unit must always be stored and transported upright,
otherwise you may cause irreparable damage to the compressor; in case of
doubt we suggest to wait for at least 24 hours before you start air-
conditioning unit.
Avoid restarting the air conditioning unit unless 3 minutes have passed since
being turned off, or the compressor may be damaged.
Never use the mains plug as a switch to start and turn off the air conditioning
unit. Use the provided ON/OFF switch located on the control panel.
Do not place the Portable Air conditioner next to heat sources or direct sunlight.
Always place the portable air conditioner on a dry stable place.
Always use the original supplied accessories. Any third party accessory might
damage the appliance.
The ideal environmental temperature for the portable air conditioner should be 15-
35ºC.
The appliance shall not be installed in the laundry.
The appliance must be positioned so that the plug is accessible and it shall be
installed in accordance with national wiring regulations.
Special warning
Place the A/C on even ground and install it vertically so as to ensure normal
operation of the compressor.
The A/C should be at least 50cm away from surrounding objects. Keep air inlet
and outlet smooth.
Do not operate the A/C near gasoline or any other inflammable liquid.
Do not use spraying agent and other solvent or flammable substances near the
A/C; otherwise, its plastic may deform and electric parts may be damaged.
Energy Saving Tips
Do not cover or restrict the airflow from the Outlet or Inlet grills.
The minimum distance from furniture and wall should be 50CM.
Keep the filters clean. Under normal conditions, the filters should be cleaned
approximately every 30 days. Since the filters remove airborne particles, more
frequent cleaning maybe necessary, depending on the indoor air quality.
Set the fan speed switch to high cool and the thermostat to the coolest position for
the initial start-up, then set the fan switch to Low cool and lower the thermostat to a
comfortable setting.
Suggestions
If you want to get better effect, we suggest you not to use cooling function when
ambient environment is higher than 35 ºC.
Basic functions
This unit offers cooling, dehumidifier and fan mode, ideal for home and office
use.
The unit include 2 fan-speed level accessible by the panel control or the remote
control.
This unit is designed with various protection functions such as 24 hours
programmable timer, auto condensation, intelligent temperature sensor and
water control with warning.
The ideal temperature for using the portable air conditions is from 15ºC~35ºC.
Parts of the SY-AC700
1: Control Panel
2: Wind guide bar
3: Air Inlet (R)
4: Wheels
5: Handle
6: Air outlet
7: Air inlet (L)
8: Dehumidification drainage nozzle
9: Filter handle
10: Exhaust duct assembly
11: Window sealing plate assembly
12: Remote control
Control and Settings
1.
Power key
Press this button to turn On/Off the air conditioner.
2.
Mode Key
Press this button to select cool (cooling), fan only (wind) and
dry (dehumidification) mode
3.
Temperature / time up and down adjusting keys
Press this button in cooling mode to increase/decrease the
temperature.
Press the buttons in timing mode to adjust On/off time;
Press Up and Down keys simultaneously to switch between
Fahrenheit and Celsius temperature.
4.
Wind Speed key
Press this button to select High or low wind speed
5.
Timer key
In Standby mode, press this button to set the ON time.
In start-up mode, press this button to set the OFF time.
6.
Temperature / time display window
The LCD display indicates the adjusted temperature and time.
7.
Remote controller receiving window
Remote sensor to receive signal from the remote controller.
8.
ºC-ºF switching key
Press this button to switch between ºC and ºF
9.
Sleep Key
Press this button under cooling mode or press the “Timing” button and “Down” button
simultaneously to activate the Sleep mode.
The fan will start to blow at low speed (Low indicator light turn on)
At this time the temperature will keep on increasing 1ºC every 2 hours
and will remain constant after two increases. (The fan speed cannot be adjusted).
Placement and installation
Placement
Place the portable AC on a flat floor near a window.
Pl ace the machine in a dry place and keep it at least 50cm away from any
surrounding objects.
Installation
Screw the exhaust duct assembly (exhaust joint end) into the rear panel exhaust port
(anticlockwise).
Insert the air exhaust hose into the window sealing plate, adjust the opening width
of the window so that the window can match with the sealing plate properly; the
length of the sealing plate is adjustable.
Incorrect installation
It is important to keep the exhaust duct clean and smooth. Incorrect installation will
affect the functioning of the A/C.
Prevent bending the exhaust pipe.
Ensure air can flow smoothly in the duct.
Warning:
The exhaust duct is designed especially for this model.
Do not replace or stretch it or it will result in failure.
Notice:
The maximum developed length of the exhaust duct is 1,500mm. Shorten its length as far as
possible while in use. Keep it horizontal while installation.
Operation method
Cooling mode
When the A/C enters into the cooling mode automatically or the cooling mode is
selected after the power is turned ON, the cooling indicator lamp lights up.
Press the Up/Down key to adjust the temperature (16 ºC ~30
ºC).
Press the Speed key to select between High and Low speed.
Fan mode
Press the mode button on the control panel or the remote control to choose the
Fan mode, the wind indicator lamp will turn on.
Press the Speed button to select between High and Low speed.
The temperature cannot be set under fan mode.
Dehumidification mode
Press the mode button on the control panel or the remote control to select the
dehumidification mode. The dehumidification indicator light will turn on.
When entering dehumidification mode, if the room temperature 17 ºC (62 ºF), the
Compressor will start to work. When the room temperature 15 ºC (59 ºF), the
Compressor stops.
When the temperature raises back to 17 ºC, the compressor restarts again. (in order to protect
the compressor, it will be restarted 3min. later).
In dehumidification mode, the speed of the fan is by default at Low speed and the
wind speeds is not adjustable.
Timer mode
In standby mode, press the Timer button to set ON time. Press the Up and Down
buttons to set the starting time (1~24H), the timer indicator lamp lights on.
In startup mode, press the timer button to set OFF time. Press the Up and Down
buttons to set the switch off time (1~24H), the timer indicator lamp lights on.
Sleep mode
When in cooling mode, press the remote controls "sleep" key (or press the "timing"
+ "down" buttons simultaneously) to put the unit into sleep mode. The fan will begin
to blow on low speed and the low wind indicator will light up. In this case, the wind
speed cannot be adjusted. Press the buttons once more to exit the current mode.
Important Note:
Never turn off the air conditioner by unplugging it from the power supply. Always press the
"ON / OFF" button and wait a few minutes before unplugging it. This allows the device to
perform a check cycle to verify operation.
Water Drainage
The product has an automatic water evaporation system. The circulation of condensed water cools
down the condenser. This not only increases refrigeration efficiency but also saves energy.
If the internal vessel is full of water, the display screen will
display “FL”, and the compressor stops working automatically.
1. Turn the unit off and unplug the power cord.
2. Remove the exhaust duct assembly.
3. Move the unit to an appropriate place.
4. Unscrew the water drainage cover and unplug the water
blocker. Use a water container to remove the water from
under the unit.
5. Plug in the water drainage cover well.
6. Reinstall the exhaust duct assembly and start the machine.
Maintenance
Note: in order to avoid electric shock, please turn off the A/C and unplug before
maintenance or repair.
Cleaning the surface
Clean the housing with a duster or a soft wet cloth. Do not use any chemical solvent (such as
benzene, alcohol, gasoline). The surface may be damaged or may even deform the complete outer
casing.
Air filter cleaning
Clean the air filters every 2 weeks. If the air filter is blocked with dust, the efficiency will reduce.
1)
Pull the filter out towards you and then pull it up as shown below.
2)
Wash the air filters by immersing it gently into warm water (about 40 ºC) with a neutral detergent,
rinse it and dry it thoroughly in a dry place.
3)
Install the air filters carefully after cleaning the filters. Make sure they are well fit before using the
unit again.
If the filter is not too dirty, If the filter is very dirty,
use a vacuum cleaner clean it with warm water
to suck the dust. The ideal temperature of the water is 40ºC
Note:
1. Do not use high temperature water when cleaning the filter. (Optimum temperature is 40ºC) or
harsh detergents such as alcohol, petrol, benzene, etc..
2. In order to avoid filter screen deformation, keep the filter away from direct heat and place it in a dry
area.
3. Do not operate the machine without its filter. This can cause damage to the unit.
After Season Maintenance
1.
Pull out the plug in a drainage hole and empty the water-receiving plate, or drain out the water by
leaning the unit. Then enter into the fan mode, and press the button for 5 seconds until it sets to
the low fan speed. Keep this mode on for half a day until its inside becomes dry.
2.
Turn off the unit and pull out the plug.
3.
Clean its filter screen and reinstall back.
4.
Tie the wire and bind it together, then put it into the accessories storage space.
5.
Remove the exhaust pipe and accessories and keep them safely.
6.
Put the unit into a plastic bag, and then keep it in a cool and dry place.
7.
Take out the batteries of remote control and safely keep them.
* All accessories can be placed in the accessories storage on the back of the unit.
Using the unit after a long time
1. Check whether the water plug and filter screen are installed.
2. Check whether the power cord is intact. If it has any signs of breakage, do not use the A/C
3. Reinstall the remote control batteries.
4. Reinstall other parts following the installation instructions.
Error detection
Error-detecting code Multi-functional defection
E1 Coil temperature sensor failure
E2 Indoor temperature sensor failure
E4
Anti
-
freez
e
protection
. When the coil
temperature is below 0ºC, the
whole machine will stop. When the coil temperatures raises to 8ºC or
more, the protection will disconnect and the unit will restore to its
original working state.
TROUBLESHOOTING
TROUBLE CAUSE SOLUTION
The A/C doesn’t
work
Not plug in Plug in
The display panel displays
FL
Restart the A/C after power off and
drainage process. The unit should work
fine.
Time OFF timer function is
activated
Restart the unit after turning it off for 3
minutes.
The refrigeration
effect of the
conditioner is
not good.
Direct sunlight Draw the curtain
Doors or windows are open.
Room is too crowded or heat
source placed in the room
Close the doors and windows and
remove the heat source
Dirty filter screen Clean or replace the filter screen
Air inlet or air outlet is blocked Remove the blockage
The air conditioner
makes too much
noise
The A/C is not placed on a flat
level
Place it on a flat and solid surface and
try avoid shaking.
The compressor
Does not work
The compressor delay protection
has been activated
Wait for 3 minutes and restart the
machine when its temperature is
reduced
Important information for the correct disposal of the product in accordance with
Directive 2002/96 / EC.
At the end of its useful life, the product should not be disposed off with household
waste. It must be taken to a special selective collection center of the municipal
agencies or to a distributor who presents this service. The correct elimination of an
electrical appliance avoids possible negative consequences for the environment
and health derived from an inadequate elimination and allows to recover its
materials to obtain significant savings in energy and resources. As a reminder of the
need to dispose of the appliances selectively, the product is marked with a trash
can with wheels crossed with an X.
DECLARATION OF CONFORMITY
Manufacturer Name: Satyatrade S. L.
Address: Pol. Ind. La Raya. C/ Guadalquivir, 2.
Camarma de Esteruelas, 28816 Madrid
Tel: 902 430 967
Fax: 91 8864285
NIF: B83254763
Manufacturing country: China
Description: Portable Air Condition
Sytech® SY-AC700 complies with the following directives:
EMC Standard: Directive 2014/30/EU
LVD Standard: Directive 2014/35/EU
EER Standard: Directive 2009/125/EC
ROHS Standard: Directive 2011/65/EU Restriction of Hazardous Substances
Signed: Ajeet Nebhwani Utamchandani
Sole Administrator
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Sytech SYAC700 Owner's manual

Category
Mobile air conditioners
Type
Owner's manual

Sytech SYAC700 is a portable air conditioner that provides cooling, dehumidification, and fan-only functions. It is suitable for both home and office use.

Capabilities:

  • Cooling: Cools the air in a room to a temperature between 16°C and 30°C.
  • Dehumidification: Removes excess moisture from the air, creating a more comfortable environment.
  • Fan-only: Circulates the air in a room without cooling or dehumidifying it.

Features:

  • Two fan speeds: Choose between high and low fan speeds to adjust the airflow.
  • 24-hour programmable timer: Set the unit to turn on or off at specific times.

Ask a question and I''ll find the answer in the document