Date Issued: 09/29/17 IS-44205-CB
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
Nous sommes là pour vous aider 866-558-5706
Heures : du lundi au vendredi, de 9h à 17h (heure de l’Est)
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES -
Couper le courant au niveau du panneau du disjoncteur du
circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installation.
13) Securexturetoceilingwithlockwashers[11]andlock-up
knobs[12].
14) Insertrecommendedbulbs(notsupplied).
15) Carefullyraiseglass[13]uptothexture.Passthesmaller
openingoverthebulbandsocket.Twisttheglassintothe
socketcup[14]tosecureglass(Donotover-tighten).
16) Threadlockupknobs[14]intotheholesintheglassholder[15]
tosecureglass(donotover-tighten).
17) Repeatstep16forremainingglass.
LOOP/LINK/LINK MOUNT
1) Followsteps1and2fromRigidStemMountInstructions.
2) Threadonesmallthreadedpipe[3]intoendofeachsmall
loop[15].
3) Passxturewirethroughrstloop.Threadonerstlooponto
endofeachlaststem.
4) Ononesideofxture,passxturewirethroughsecondloop
andthroughholeincanopy[4].Passthreadedpipeatendof
secondloopthroughholeincanopy.
5) Passxturewirethroughholeinlockwasher[5].Thread
lockwasherontoendofthreadedpipeprotrudingfrominside
canopy.
6) Passxturewirethroughholeinhexnut[6].Threadhexnutonto
endofthreadedpipe.
7) Onothersideofxture,passxturewirethroughsecondloop
andthroughholeincanopy.Passthreadedpipeatendofsec-
ondloopthroughholeincanopy.
8) Passxturewirethroughlooponendofsafetycable[7].Slip
looponsafetycableoverendofthreadedpipeprotrudingfrom
insideofcanopy.
9) Passxturewirethroughholeinlockwasher.Threadlockwash-
erontoendofthreadedpipeprotrudingfrominsidecanopy.
10)Passxturewirethroughholeinhexnut.Threadhexnutonto
endofthreadedpipe.
11)Attachlockinglink[17]tosmallloopatendofeachstemandto
eachlooponcanopy.
12)Followsteps7-17fromRigidStemMountInstructions.
RIGID STEM MOUNT
1) Passwirethroughstems[1]andscrewstemsintocouplings[2]
ontopofxturebody.NOTE: Threadlockingcompoundmust
beappliedtoallstemthreadsasnotedwitharrowsymbolto
preventaccidentalrotationofxtureduringcleaning,relamp-
ing,etc.
2) Passxturewirethroughremainingstemsandscrewstems
together.
3) Oneachsideofxture,passxturewirethroughonesmall
threadedpipe[3].Screweachsmallthreadedpipeontotopof
stemoneachside.
4) Oneachsideofxture,passxturewiresthrougheachhole
incanopy[4].Lowercanopydowntowardsstems.Passeach
holeincanopyoverendofeachthreadedpipeontopof
stems.
5) Ononesideofxture,passxturewirethroughholein
lockwasher[5].Threadlockwasherontoendofthreadedpipe
protrudingfrominsidecanopy.Passxturewirethroughholein
hexnut[6].Threadhexnutontoendofthreadedpipe.
6) Onothersideofxture,passxturewirethroughlooponend
ofsafetycable[7].Sliplooponsafetycableoverendofthread-
edpipeprotrudingfrominsideofcanopy.Passxturewire
throughholeinlockwasher.Threadlockwasherontoendof
threadedpipeprotrudingfrominsidecanopy.Passxturewire
throughholeinhexnut.Threadhexnutontoendofthreaded
pipe.
7) TURNOFFPOWER.
IMPORTANT:Beforeyoustart,NEVERattemptanyworkwith-
outshuttingofftheelectricityuntiltheworkisdone.
a) Gotothemainfuse,orcircuitbreaker,boxinyourhome.
Placethemainpowerswitchinthe“OFF”position.
b) Unscrewthefuse(s),orswitch“OFF”thecircuitbreaker
switch(s),thatcontrolthepowertothextureorroomthat
youareworkingon.
c) Placethewallswitchinthe“OFF”position.Ifthextureto
bereplacedhasaswitchorpullchain,placethoseinthe
“OFF”position.
8) Atthecenterofthemountingstrap[8]areknockoutslots.
Removethesetthatmatchesyouroutletbox.
9) Securethemountingstraptotheoutletbox[9].
10) Groundinginstructions:(SeeIllus.AorB).
A) Onxtureswheremountingstrapisprovidedwithahole
andtworaisedimples.Wrapgroundwirefromoutletbox
aroundgreengroundscrew,andthreadintohole.
B) Onxtureswhereacuppedwasherisprovided.Put
groundwirefromoutletboxundercuppedwasherand
greengroundscrewandthreadscrewintoholeinmount-
ingstrap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wiretooutletboxgroundwirewithwireconnector,(notprovid-
ed)afterfollowingtheabovesteps.Neverconnectgroundwire
toblackorwhitepowersupplywires.
11) Makewireconnections.Referencechartbelowforcorrect
connectionsandwireaccordingly.
12) Pushxturetoceiling,carefullypassingmountingscrews
throughholesincanopy.NOTE:Becertainwiresdonotget
pinchedbetweenmountingstrapandcanopy.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
9
3
2
1
►
►
►
►
13
5
6
RIGID STEM MOUNT
►
►
►
►
8
10
12
11
4
7
14
15
8
10
17
16
3
4
9
7
12
11
5
6
LOOP/LINK/LOOP MOUNT
9
3
2
1
►
►
►
►
13
5
6
RIGID STEM MOUNT
►
►
►
►
8
10
12
11
4
7
14
15
8
10
17
16
3
4
9
7
12
11
5
6
LOOP/LINK/LOOP MOUNT