PLANNING
GUIDE
DR30GS, DR30GFS, DR30GIS, DR30GIFS
Distinctive
30” Wide
All Gas Ranges
Document # PG05-007
Revised 04/04/13 Page 1/5
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
All tolerances ±1/16” (±1.6 mm) unless otherwise noted.
OVERALL DEPTH DIMENSIONS - SIDE VIEW
AVAILABLE BACKGUARDS
Part Number Description Compatibility
AER30GLBG Lowprole(13/4inch)
Standard on models DR30GIS, DR30GIFS
Optional on models DR30GS, DR30GFS
AERB30G03 3 Inch
Optional on models DR30GS, DR30GFS
NOT compatible with models DR30GIS, DR30GIFS
AERB30G06 6 Inch
Standard on models DR30GS, DR30GFS
NOT compatible with models DR30GIS, DR30GIFS
AERB30G09 9 Inch
Optional on models DR30GS, DR30GFS
NOT compatible with models DR30GIS, DR30GIFS
1 1/8” (2.9 cm)
DR30GI[F]S:
1/4” (6.4 mm)
thick top trim
Front of open door
Front of handle
Front panel
Rear of front panel
Backguard thickness
26 1/8” (66.4 cm)
28 9/16” (72.5 cm)
Front of knobs
28” (71.1 cm)
24” (61.0 cm)
3” (7.6 cm)
backguard*
DR30G[F]S:
Full stainless
steel side panels
DR30GI[F]S:
3 1/2” (8.9 cm)
partial stainless
steel side panels
(removable)
External handle
shown, some models
have integral handle
(see inside cover)
Grates extend
1” above trim
6” (15.2 cm)
backguard*
1 3/4” (4.4 cm) backguard*
* See table for compatibility
Product width:
29 7/8” (75.9 cm)
NOTE: Models DR30GS and
DR30GFS are not compatible
with a raised vent.
35
(88.9 cm)
to
37
(94.0 cm)
9” (22.9 cm)
Backguard*
46 3/4” (118.7 cm)
2
1
1
Only backguard model AER30GLBG is compatible with a raised vent.
1
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DR30GS, DR30GFS, DR30GIS, DR30GIFS
Distinctive
30” Wide
All Gas Ranges
Document # PG05-007
Revised 04/04/13 Page 2/5
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
A* B
C
30” min.
(76.2 cm)
36” (91.4 cm) recommended
30” (76.2 cm) min.
37” (94.0 cm)
max.
FREESTANDING INSTALLATION CABINET CUTOUT DIMENSIONS - MODELS DR30GS, DR30GFS, DR30GIS AND DR30GIFS
* See the cutout dimensions on following page for self-rimming installations.
Failure to meet or exceed the maximum and
minimum dimensions/clearances stated may result
in a fire hazard.
The range should be placed away from drafts that
may be caused by doors, windows and heating and
air conditioning outlets.
To eliminate the risk of burns or fire by reaching
over heated surface units, cabinet storage space
located above surface units should be avoided. If
cabinet storage space is to be provided directly
above the range, the risk of personal injury may be
reduced by installing a range hood.
In all instances, installation of a range hood is highly
recommended. The hood should project horizontally
a minimum of five (5) inches beyond the face of
the cabinets. See the range hood specifications for
minimum clearances.
If installing a raised vent, install only Dacor model
ERV3015.
The range may be installed flush to the rear wall.
See diagram and notes for rear wall surface
requirements. It is not necessary to install non-
combustible materials behind the range below the
countertop height.
Any openings in the wall behind the appliance or in
the floor underneath it must be sealed.
1
30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. clearance if bottom of
wood or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015”
(0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30” (76.2 cm) min. clearance between top of range grates and bottom
of unprotected wood or metal cabinet. If installing range hood, check the hood specifications for minimum required clearances.
2
Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See Product Dimensions.
3
Consult local code and following pages for requirements.
4
This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range.
5
10” (25.4 cm) min. to combustible sidewalls above range (both sides).
6
Non-combustible surface required for models DR30GIS and DR30GIFS up to vertical distance specified in note 1 or range hood, whichever is lower. Non-
combustible surface recommended, but not required, for models DR30GS and DR30GFS.
Note 2
B
A
Back wall
immediately
behind range
6
Top of
finished
counter
13” (33.0 cm)
max.
4
14” (35.6 cm)
min.
4
C
Suggested
location of
utilities
3
Note 5
Note 1
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DR30GS, DR30GFS, DR30GIS, DR30GIFS
Distinctive
30” Wide
All Gas Ranges
Document # PG05-007
Revised 04/04/13 Page 3/5
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
1
On models DR30GIS and DR30GIS, non-combustible surface required immediately behind range, as specified on previous page, when back of
backguard is less than 2 1/2” (6.4 cm) from rear wall.
2
Models DR30GIS and DR30GIS include self-rimming trim piece that attaches to back of range and covers the edge of the countertop overhang in back.
3
To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm). This configuration is only for models DR30GIS
and DR30GIS with side panels behind door removed.
For all self-rimming installations:
Countertop height: 34 3/4” (88.3 cm) min.
36 7/8” (93.7 cm) max.
Countertop thickness: 1 5/8” (4.1 cm) max.
CABINET DEPTH GREATER THAN 25 1/8”
2
3 1/4” SIDE PANELS REMOVED, RANGE BACK
OVERHANGING COUNTERTOP (TOP VIEW)
CABINET DEPTH GREATER THAN 24”
2
3 1/4” SIDE PANELS INSTALLED, RANGE BACK
OVERHANGING COUNTERTOP (TOP VIEW)
CABINET EXACTLY 24” DEEP, 3 1/4” SIDE PANELS
REMOVED, RANGE BACK FLUSH TO WALL (TOP VIEW)
CABINETS LESS THAN 24” DEEP, 3 1/4” SIDE PANELS
INSTALLED, RANGE BACK FLUSH TO WALL (TOP VIEW)
Non-combustible
rear wall required
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
10” min. (25.4 cm)
to any combustibles
above counter both sides
21
(53.3
cm)�
to
24
(61.0 cm)
20 3/4”
(52.7 cm)
25 5/8”
max.
(65.1 cm)
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
10” min. (25.4 cm)
to any combustibles
above counter both sides
Countertop overhang
1 5/8” (4.1 cm) max.
24
(61.0 cm)
Non-combustible
rear wall required
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/4” min. (1.9 cm)
countertop overhang
10” min. (25.4 cm)
to any combustibles
above counter both sides
21 1/8”
(53.7 cm)
to
24 1/8”
(61.3 cm)
20 7/8”
(53.0 cm)
25 3/4”
(65.4 cm)
max.
Countertop front
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
1” min. (2.5 cm)
Countertop overhang
10” min. (25.4 cm)
to any combustibles
above counter both sides
Countertop overhang
1 5/8” (4.1 cm) max.
24 1/8”
(61.3 cm)
Self-Rimming Installation, custom Cutout Options (Models DR30GIS and DR30GIFS Only)
1
1
1
1
3
3
3
3
NOTE: The diagrams below are for installations that require custom cutouts. See page 5/5 for installation in standard 30 inch wide cutout.
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DR30GS, DR30GFS, DR30GIS, DR30GIFS
Distinctive
30” Wide
All Gas Ranges
Document # PG05-007
Revised 04/04/13 Page 4/5
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
1
To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm). Width notches remains 30”.
2
For 24 to 24 1/4 inch deep cabinets, the side panels and control panel will protrude from the cabinet face a total of 5 5/8 inches.
For all installations with a raised vent:
Countertop height: 34 3/4” (88.3 cm) min.
36 7/8” (93.7 cm) max.
Countertop thickness: 1 5/8” (4.1 cm) max.
NOTE: For all raised vent installations, use only Dacor raised vent model
ERV3015.
CUSTOM CABINET 27 1/2” OR DEEPER,
PARTIAL SIDE PANELS REMOVED (TOP VIEW)
SIDE VIEW - DR30GI[F]S RANGE AND
ERV3015 RAISED VENT
24 1/4” - 27 1/2” CABINET DEPTH
PARTIAL SIDE PANELS INSTALLED (TOP VIEW)
24” - 24 1/4” CABINET DEPTH
PARTIAL SIDE PANELS INSTALLED (TOP VIEW)
2
Raised Vent (Self-Rimming) Installation Cutout Options (Models DR30GIS and DR30GIFS Only)
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
3/8” (9.5 mm) min.
countertop overhang
3”
(7.6 cm)
10” min. (25.4 cm)
to any combustibles
above counter both sides
Countertop overhang
1 5/8” (4.1 cm) max.
20 5/8”
(52.4 cm)
raised vent opening
27 1/2” (69.9 cm)
Cabinet face
Countertop
IMPORTANT: If optional side panels are not installed cabinet
face must be flush with back of control panel.
Back of
control panel
DR30GI[F]S
range
3/8” min. (1.0 cm)
space behind raised vent
chassis to clear stiffener
3/8” min. (1.0 cm) flat countertop
overhang required behind cutout
Shown with partial
side panel installed
29 1/2” (74.9 cm)
ERV3015
raised vent
Stiffener
Wall
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
3/8” (9.5 mm) min.
countertop overhang
3”
(7.6 cm)
10” min. (25.4 cm)
to any combustibles
above counter both sides
Countertop overhang
1 5/8” (4.1 cm) max.
24 1/8”
(61.3 cm)
raised vent opening
27 1/2” (69.9 cm)
20 7/8”
(53.0 cm)
to
24 1/8”
(61.3 cm)
Countertop
front
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
3/8” (9.5 mm) min.
countertop overhang
3” (7.6 cm)
10” min. (25.4 cm)
to any combustibles
above counter both sides
20 5/8”
(52.4 cm)
raised vent opening
27 1/2” (69.9 cm)
25 3/4”
(65.4 cm)
max.
1
1 1
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DR30GS, DR30GFS, DR30GIS, DR30GIFS
Distinctive
30” Wide
All Gas Ranges
Document # PG05-007
Revised 04/04/13 Page 5/5
12 1/4”
(31.1 cm)
to
14 1/4”
(36.2 cm)
4 1/4”
(10.8 cm)
10” (25.4 cm)
10” (25.4 cm)
12” (30.5 cm)
2 1/2”
(6.4 cm)
3 1/2”
(8.9 cm)
1” (2.5 cm)
BACK OF RANGEUTILITY CLEARANCE BEHIND RANGE
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Natural 5” 6” 1/2 psi
LP 10” 11 1/2 psi
ELECTRICAL REQUIREMENTS
Electrical Circuit
Required
Total Connected
Load
120 Vac, 60 Hz, 15 Amps.,
dedicated, grounded
4.0 Amps. @
120 Vac, 60 Hz
IMPORTANT: The information above is for reference only. If the above
data does not agree with the product data label, use the data on the
product data label.
The gas inlet on the regulator accommodates a 1/2” NPT gas line
connection. The range can also accommodate a 3/4” NPT gas line
connection by removing the 1/2” to 3/4” adapter on the regulator inlet.
6’ (183 cm)
long
STANDARD WIDTH CUTOUT FOR MODEL DR30DI[F]S
SELF-RIMMING TRIM KIT ATKDR30GW REQUIRED
Electrical Specifications/Dimensions, All Models
Self-Rimming Installation, Standard Cutout Requirements (Models DR30GIS and DR30GIFS Only)
Non-combustible
rear wall required
30” (76.2 cm)
countertop/cabinet opening
below countertop
Countertop front
Cabinet face
10” min. (25.4 cm)
to any combustibles
above counter both sides
24 3/8”
min.
(61.9 cm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Dacor DR30GFSNG User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI