BEA RESTROOM KIT Product information

Type
Product information

This manual is also suitable for

BEA RESTROOM KIT

The BEA Restroom Kit is a programmable 3 relay logic module that can be used to control access to restrooms. The kit includes a variety of components that can be used to create a customized access control system, including:

  • Br3-X Restroom Control Module: The Br3-X is the brains of the system. It controls the operation of the other components and can be programmed to meet your specific needs.
  • Occupied Indicator: The occupied indicator lets people know when the restroom is in use.
  • Assistance Required Signal: The assistance required signal can be used to call for help in an emergency.

BEA RESTROOM KIT

The BEA Restroom Kit is a programmable 3 relay logic module that can be used to control access to restrooms. The kit includes a variety of components that can be used to create a customized access control system, including:

  • Br3-X Restroom Control Module: The Br3-X is the brains of the system. It controls the operation of the other components and can be programmed to meet your specific needs.
  • Occupied Indicator: The occupied indicator lets people know when the restroom is in use.
  • Assistance Required Signal: The assistance required signal can be used to call for help in an emergency.
SIZE:
DRAWN BY:
A
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY:
WJR
SCALE: DATE:
NONE 14 MARCH 2017
PART NO:
SHEET
1 OF 1
NOTES:
TITLE: Br3-X RESTROOM KIT/
EMERGENCY ADD ON KIT
(NORMALLY LOCKED & UNLOCKED)
Br3-X
GND
GND
GND
GND
NC-1
NO-1
NC-2
NO-2
RELAYS
POWER
RELAY 1
INCR.
FUNCT.
SETUP
WET
DC
WET
AC
DRY WET
INPUTS
NC-3
NO-3
COM-1
COM-2
COM-3
W
ET
WET
1
23
RoHS Compliant
Programmable 3 Relay
Logic Module
IN-1
IN-2
IN-3
IN-4
1
2
/
2
4
V
A
C
/
D
C
COM
DOOR
CONTROL
ACT
n
ELECTRIC STRIKE
INSIDE
PUSH TO
LOCK
COM. N.O.COM. N.O.
COM. N.C.
MAGNET
DOOR POSITION
SWITCH
SWITCH IS CLOSED
WHEN DOOR IS CLOSED
12/24 V
AC/DC
POWER
12/24 V
AC/DC
POWER
12/24 V
AC/DC
POWER
+
_
+
_
"PUSH TO LOCK" BUTTON
(10PTLBUTTON)
OCCUPIED INDICATOR
(10LEDSOUNDER)
(10SWITCH1084)
=L
=U
FOR NORMALLY
LOCKED RESTROOM
FOR NORMALLY
UNLOCKED RESTROOM
SEE NOTE 2
COM. N.O.
OUTSIDE
SEE NOTE 1
OCCUPIED
WHEN
LIT
PUSH
TO OPEN
PUSH
TO OPEN
OUTSIDE
(10BR3X)
LOCKED
WHEN LIT
80.0397.00
Upon completion of the installation or service work, at a minimum, perform a daily safety check in accordance with the minimum
inspection guidelines provided by AAADM. Provide each equipment owner with an owner’s manual that includes a daily safety
checklist and contains, at a minimum, the information recommended by AAADM. Offer an information session with the equipment
owner explaining how to perform daily inspections and point out the location of power/operation switches to disable the equipment if
a compliance issue is noted. The equipment should be inspected annually in accordance with the minimum inspection guidelines. A
safety check that includes, at a minimum, the items listed on the safety information label must be performed during each service call.
If you are not an AAADM certified inspector, BEA strongly recommends you have an AAADM certifi ed inspector perform an AAADM
inspection and place a valid inspection sticker below the safety information label prior to putting the equipment into operation.
24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 |
General Tech Questions: [email protected] | Tech Docs: www.beasensors.com
N/O N/C
1
2
3
4
IN THE EVENT OF AN EMERGENCY
PUSH EMERGENCY BUTTON
AND AUDIBLE AND VISUAL SIGNAL
WILL ACTIVATE
12/24 VDC
POWER
SUPPLY
V-
V+
RED
BLACK
BLACK
WHT
BLACK
RED
BUZZER
LED
ASSISTANCE REQUIRED
SIGNAL
(10ARS)
EMERGENCY SIGNAGE (70.5675)
"PUSH FOR EMERGENCY
ASSISTANCE" BUTTON
(10EBUTTONCOMBO)
SEE NOTE 3
SEE NOTE 3
INSIDE
SEE NOTE 4
SEE NOTE 4
SEE NOTE 4
SEE NOTE 4
1) FOR INPUTS 1 & 2 ANY "DRY" CONTACT ACTIVATION DEVICE MAY BE USED.
2) FAIL SAFE FOR NORMALLY UNLOCKED (WIRE N.O.)
FAIL SECURE FOR NORMALLY LOCKED (WIRE N.C.)
3) CONNECT IN SERIES WITH DOOR POSITION SWITCH WHEN USED WITH
BR3-X RESTROOM CONTROL MODULE
4) ONE POWER SUPPLY CAN BE USED TO POWER ALL DEVICES.
5) KIT DOES NOT INCLUDE POWER SUPPLY, PUSH PLATES, ELECTRIC STRIKE OR DOOR CONTROL
  • Page 1 1

BEA RESTROOM KIT Product information

Type
Product information
This manual is also suitable for

BEA RESTROOM KIT

The BEA Restroom Kit is a programmable 3 relay logic module that can be used to control access to restrooms. The kit includes a variety of components that can be used to create a customized access control system, including:

  • Br3-X Restroom Control Module: The Br3-X is the brains of the system. It controls the operation of the other components and can be programmed to meet your specific needs.
  • Occupied Indicator: The occupied indicator lets people know when the restroom is in use.
  • Assistance Required Signal: The assistance required signal can be used to call for help in an emergency.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI