Broan C3, C4, C5 Replacement Coils for MH Installation guide

Type
Installation guide

This manual is also suitable for

708228A (Replaces 7082280)
ADDENDUM
IMPORTANT NOTE:
When installing this coil as a replacement coil in an air handler or cased coil, the suction
line tube on the coil must be repositioned to allow the tube to exit through the close-off
plate on the air handler or cased coil.
Re-position the tube by un-brazing the joint in the 2 piece suction header, rotate the tube
145° so it is in the 12 o’clock position, then re-braze the joint.
Specifications & illustrations subject to change without notice or incurring obligations (06/15).
O’Fallon, MO, © Nortek Global HVAC LLC 2015. All Rights Reserved.