SGB SERIES ― GRAVITY FEED IRON
Model No. SGB600/SGB700/SGB900
Outer Cover Replacement ver.2111
Part# S6060 [Ref. #21-7]
Content: 1pc
Technical Support Steps
❶ Hold and slide up metal ring, then ❷ Remove dial screw and dial spring ❸ Remove screws(3) and gently open
detach from the outer cover set, then the dial housing the outer cover
❹ Inspect and make sure to remove ❺ Make sure to properly tuck in all wires ❻ Gently install new outer cover and lock
all broken pieces from inside of iron in between the covers before closing both covers in place with the metal ring
❼ Verify the thermostat stem is centered ❽ By losening screw(2) the cover can ❾ Repeate steps 6, 7 and 8 until the stem
If not, remove cover and make adjustments be moved slightly up, down and left, right is successfully centered. Tighten the outer
cover screws(step 3) and then the dial set
(step 2)
Copyright ©2021 Hot-Steam® All rights reserved
― For additional assistance contact Hot-Steam® Technical Support (631) 393-2811 or support@hot-steam.com ―
Before attempting to troubleshoot the iron, turn off and unplug the
iron from the power supply. Close the valve on the Water Tank and
disconnect the hose from the iron. Wait for the iron to cool down.