TC2421IX

Njoy TC2421IX Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Njoy TC2421IX Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
TC2421IX

 


2 3
nJoy  
Ranger Series 120KT / 180KT
Thank you for purchasing our products!

Focusing on quality at compeve prices, here at
nJoy, we are creang innovave and reliable power
protecon soluons for every customer in casual,
business and industrial environments.
This EBM together with the UPS will protect your electronic
equipment from physical damage and will provide emergency
baery backup power to prevent data loss in the event of
power problems.
Step 2



Installation and assembly of the cabinet1
Step 1



1
AB
2
3
45
Front of the cabinet
4 5
Step 3



Step 4




No. Name Descripon Length (cm) Quanty (pcs) Observaons
11Battery to Battery
2x AWG 1/0 35 32 Ring 8.4mm to
Ring 8.4mm
22Battery to Battery
2x AWG 1/0 50 6 Ring 8.4mm to
Ring 8.4mm
3BAT+
Battery to Breaker
pozitive (+)Pole 2x
AWG 1/0
80 1 Ring 8.4mm to
Ring 10.4mm
4BAT-
Battery to Breaker
negative (-) Pole
2x AWG 1/0
180 1 Ring 8.4mm to
Ring 10.4mm
5N1
Battery to Breaker
neutral N1 Pole 2x
AWG 1/0
60 1 Ring 8.4mm to
Ring 10.4mm
6N2
Battery to Breaker
neutral N2 Pole 2x
AWG 1/0
180 1 Ring 8.4mm to
Ring 10.4mm
BAT + Cabinet to Cabinet
2x AWG 1/0 150 1 Ring 10.4mm to
Ring 10.4mm
BAT
N
Cabinet to Cabinet
2x AWG 1/0 150 1 Ring 10.4mm to
Ring 10.4mm
BAT - Cabinet to Cabinet
2x AWG 1/0 150 1 Ring 10.4mm to
Ring 10.4mm
NOTE!
The cable numbering corresponds to the ones on the connection diagram and on
the illustrations.
Each cable in the battery cabinet consists in two cables linked to the same
connector.
7
6 7
Level 1
Level 2
Level 3
Level 4
N
Breaker
350 Ah
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
4
2
2
3
5
2
2
2
2
6
Back of the cabinet
Top
Bottom
Step 5



6 (N2)
This cable connects
from the first level to
the breaker
5 (N1)
This cable will connect
from the last level to the
breaker
Back of the cabinet
Front of the cabinet
2 (50cm)
These cables will connect to
the next row of batteries.
1
4 (BAT-)
 

8 9
Step 6




Back of the cabinet
Front of the cabinet
1
2 (50cm)
These cables will connect to
the next row of batteries.
2 (50cm)
The cables from the first
level connect to these two
batteries on the second level.
Step 7



Back of the cabinet
Front of the cabinet
2 (50cm)
These cables will connect to
the next row of batteries.
2 (50cm)
The cables from the second
level connect to these two
batteries on the third level.
1
10 11
Step 8



Back of the cabinet
Front of the cabinet
1
2 (50cm)
The cables from the third
level connect to these two
batteries on the fourth level.
5 (N1)
This cable connects
from the fourth level
to the breaker
3 (BAT+)
3 (BAT+)
6 (N2)
7
5 (N1)
4 (BAT-)
Step 9




NOTE!
There are a total of 4 cables that connect to the breaker from the battery side of
the cabinet, and 3 cables that connect to the breaker from the UPS (or another
cabinet) side.
All the cables shipped with the cabinet are black. We used colors on this manual
to make the connection diagram and illustrations easier to understand.
12 13
Step 11


Step 12









Back of the cabinet
Front of the cabinet
Step 10



Back of the cabinet
Front of the cabinet
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries with
separate collecon systems)





         


Memo
/