universal douglas LRL14-30L840-750C Operating instructions

Type
Operating instructions

The Universal Douglas LRL14-30L840-750C is a 4' LED Lensed Module that's easy to install, has a long lifespan, and provides broad, even light distribution. With an integrated heat sink for cool operation and a Class 2 rating for simplified wiring, this module delivers up to 3150 initial lumens at 4000K with a CRI of >82. Its lumen maintenance ensures L85 > 60Khrs and L70 > 140Khrs while maintaining color consistency of <3 SDCM.

The Universal Douglas LRL14-30L840-750C is a 4' LED Lensed Module that's easy to install, has a long lifespan, and provides broad, even light distribution. With an integrated heat sink for cool operation and a Class 2 rating for simplified wiring, this module delivers up to 3150 initial lumens at 4000K with a CRI of >82. Its lumen maintenance ensures L85 > 60Khrs and L70 > 140Khrs while maintaining color consistency of <3 SDCM.

LRL1430L8xx750C
www.universaldouglas.com
April, 11 2022 Universal Lighting Technologies
Description: 4’ LED Lensed Module
Simple and easy installation
Long life with high efficacy
Diffuser lens provides broad, even light distribution
Integrated heat sink for cool operation
Class 2 rating simplifies wiring
Lumen
Performance:
Catalog Number Nominal CRI
Current
(Amps) Initial
Lumens (1) Vf (2)
(Volts)
Power
(Watts) Lm/W
LRL14-30L840-750C 0.525 2,435 35 18 133 >82
0.700 3,150 36 25 125
1.050 4,500 38 40 113
General Performance Specifications
Lumen Maintenance : L85 > 60Khrs (reported)
L70 > 140Khrs (calculated)
@I= 1050mA, tamb=40°C
Color Consistency: <3 SDCM (3500K, 4000K)
<4 SDCM (5000K)
Application:
Min. Ambient Operating Temp.:
Max. Ambient Operating Temp.:
‐22°F, ‐30°C
140°F60°C
Maximum Current rating of 1.05 Amps
Regulatory
UL8750
CSA250.13‐14
RoHS Compliant
Notes:
Performance data taken at Tamb = 25°C
Power consumption and photometric performance are
typical values
Lumen maintenance value is based on LM80 testing and
TM‐21 calculation projections.
Mechanical Dimensions
42.46”
0.8”
1.24”
1.4lbs
Length:
Width
Height:
Weight:
Lead Length:
Red & Blue 24”
(1) MID Flux Bin Values are shown for CCT of 4000K. Tolerance of ±6.5% at 25°C
(2) Vf is at Tc of 25°C with max tolerance of +/‐ 5%.
Ordering Information
Part Number CCT
Lumen Multiplier
LRL14‐30L835‐750C10C 3500K 96.7%
LRL14‐30L840‐750C10C 4000K 100.0%
LRL14‐30L850‐750C10C 5000K 104.1%
Carton Quantity: 10
Application and operation performance specification information subject to change without notification.
Page 1 of 3
LRL1430L8xx750C
www.universaldouglas.com
April, 11 2022 Universal Lighting Technologies
Installation & Assembly Guidelines
This module is to be mounted using mounting slots and
fasteners. The aluminum frame should be grounded or
mounted to a grounded metal surface.
Modules may be connected in parallel to split current
from the LED driver.
1.24
1.55
Side profile with
end cap removed
Photometric Distribution LED Color Consistency Spectral Power Distribution
4000K
Dimensions
24” 20AWG
Stranded
Copper Leads
90
95
100
105
85
25 30 35 40 45 50 55 60 65 70 75
Tc (°C)
Relative Lumens (%)
Relative Lumens vs. Temperature
Application and operation performance specification information subject to change without notification.
Page 2 of 3
LRL1430L8xx750C
www.universaldouglas.com
April, 11 2022 Universal Lighting Technologies
Conditions of Acceptability
1.The LED modules are intended for connection to a Class 2, constant current source of supply.
The connection of the LED arrays to a source of supply other than class 2, the suitability must be
determined in the end use product investigation.
2.The LED modules shall be installed in compliance with the mounting, spacing, casualty, and
the segregation requirements applicable to the ultimate application.
3. The LED modules were subjected to the Normal Temperature Test in a 40°C Ambient.
Application and operation performance specification information subject to change without notification.
Page 3 of 3
4.The LED Array modules are suitable for “DRY” locations. The use in other than dry locations
shall be evaluated to the end use application.
5.The array modules may be marked with any voltage and current rating that do not exceed the
maximum ratings specifies in the ELECTRICAL RATINGS.
6. Suitability of input connections to the LED module to be determined in
the end use product.
Application Notes:
1. The standard base model version of this module without Conformal Coating is designed for
indoor fixtures in dry applications. Damage caused by corrosion due to moisture, condensation
and other harmful elements, is not covered by the warranty.
Model
Maximum Input
Current
Location
Center of the PCB
Measured
°
C
Limit
°C
*
LRL14-30Lyzz-aaaC 1200 mA
Between
48th and
49
th LED
68.7 105
Center Bottom
Heat Sink 63.7 --
  • Page 1 1
  • Page 2 2
  • Page 3 3

universal douglas LRL14-30L840-750C Operating instructions

Type
Operating instructions

The Universal Douglas LRL14-30L840-750C is a 4' LED Lensed Module that's easy to install, has a long lifespan, and provides broad, even light distribution. With an integrated heat sink for cool operation and a Class 2 rating for simplified wiring, this module delivers up to 3150 initial lumens at 4000K with a CRI of >82. Its lumen maintenance ensures L85 > 60Khrs and L70 > 140Khrs while maintaining color consistency of <3 SDCM.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI