Braemar Ducted Gas TB TE TX Owner's manual

Category
Split-system air conditioners
Type
Owner's manual

This manual is also suitable for

H
o
m
e
O
wn
e
r
s
G
uid
e
G
A
S
DUC
TE
DH
E
A
TE
R
T
B
SE
R
IES
APRIL 2002
F
ea
t
u
r
es
1. Heat exchanger - 10 year warranty
2. Fully automatic electronic ignition
3. Approved by the
Australian Gas Association
4. Extra Air Models - TBX
I
N
T
R
O
DUC
TIO
N
Congratulations on choosing a Braemar Gas Ducted Heating Unit.
Your Braemar Heater is built from the highest quality materials
and is engineered to provide many years of trouble free performance.
Please take a moment to read these instructions.
D
e
li
ve
r
y
The customer or installer, upon delivery of the heater should ensure
that the model number and gas type is as requested.
A data label on the end of the heater details both the model
number and gas type.
Please check the heater and report any freight damage.
D
es
ign
e
d
a
nd
m
a
nu
f
ac
t
u
r
e
din
A
u
s
t
r
a
li
a
t
o
exac
t
ing
s
t
a
nd
a
r
d
s
.
ill0001tb
G
A
S
DUC
TE
DH
E
A
TE
R
T
B
/ TE / TX SE
R
IES
G
as
in
C
o
m
bu
s
t
ion
A
i
r
I
n
t
ake
L
ou
v
r
es
H
ea
t
e
r
D
a
t
a
L
a
b
e
l
M
a
in
s
I
n
&
T/S
t
a
t
A
I
R
I
N
A
l
t
e
r
n
a
t
i
ve
F
lu
e
L
o
ca
t
ion
TE
Gas Ducted Heater
TE
Gas Ducted Heater
P
a
r
t
No
.
.
.
!
D
O
N
O
T
O
p
e
r
a
te
this a
p
p
lia
n
c
e
be
fo
r
e
r
e
a
d
ing
th
e
in
s
tr
u
c
t
io
n
bo
o
k
l
e
t
D
O
N
O
T
P
l
a
c
e
a
rt
icle
s
o
n
o
r
a
g
a
ins
t t
h
is
a
p
p
li
a
n
c
e
D
ON
O
T
S
to
r
e
c
h
e
m
ic
a
ls
,
fla
mm
a
b
le
m
a
te
r
i
a
ls
o
r
s
p
r
a
y
a
e
ro
s
o
ls
n
e
a
r
th
is
a
p
p
lian
ce
.
D
O
N
O
T
O
p
e
r
at
e
w
it
h p
a
n
e
ls
,
co
v
e
rs
o
r
g
u
a
rd
s
r
em
o
v
e
d
fr
o
m
th
is
a
p
p
li
a
n
c
e
.
F
OR
I
N
S
T
A
L
L
A
T
I
O
N
I
N
D
OO
R
S
O
N
L
Y
T
O
B
E
I
N
S
T
A
L
L
E
D
B
Y
A
N
A
U
T
H
O
R
I
S
E
D
P
E
R
S
O
NO
N
L
Y
9
6
0
1
0
5
5
E
N
E
R
G
Y
R
A
T
I
N
G
U
S
E
T
H
I
S
L
A
B
E
L
T
O
C
O
M
P
A
R
E
D
I
F
F
E
R
E
N
T
M
O
D
E
L
C
E
N
T
R
A
L
H
E
A
T
E
R
S
C
O
M
P
A
R
A
T
IV
E
E
N
E
R
GY
C
O
N
S
U
M
P
T
IO
N
T
H
I
S
B
R
A
E
M
A
R
T
B
6
5
,
T
B
9
0
,
T
B
1
2
0
U
S
E
D
W
H
E
N
T
E
S
T
E
D
T
O
A
U
S
T
R
A
L
I
A
N
G
A
S
C
O
D
E
A
G
1
0
6
A
C
TU
A
L
E
N
E
R
G
Y
U
S
E
D
W
IL
L
D
E
P
E
N
D
O
N
W
H
E
R
E
Y
O
U
LIV
E
A
N
D
HO
W
T
HE
A
PP
L
I
A
N
C
E
I
S
U
S
E
D
A
P
P
L
I
A
N
C
E
R
U
N
N
I
N
G
C
O
S
T
I
N
F
O
R
M
A
T
I
O
N
I
S
A
V
A
I
L
A
B
L
E
FR
O
M
Y
O
U
R
L
O
C
A
L
G
AS
S
U
P
P
L
I
E
R
M
J
/
m
3
P
E
R
Y
E
A
R
GA
S
XXX
N
8
3
7
E
lec
trica
l A
p
p
rova
l
to A
S 3
10
0
A
G
A
A
PPR
O
V
A
L
N
o. 5904
SPECIFICATIONS
Gas Rate MJ ( nom )
65
90
120
Gas Pressure Nat. kPa .87
.87
.87
LPG kPa
2.75 2.75
2.75
Injector Size - Nat - mm
2.20
2.20 2
.20
-LPG- mm 1.30 1.30
1.30
A
irflow @
100 Pa L/se
c 420
540 7
90
Nominal Temp Rise -
o
C 30
30
30
Operatin
g Voltage
240 240 2
40
Fan Motor Size - Watts 315 315 315
Max Current - Amps
3.0
3.0
6.0
L
ig
h
t
in
g
I
n
s
t
r
u
c
tio
n
s
1
.
S
e
t
R
o
o
m
T
h
e
r
m
o
sta
t
t
o
B
e
lo
w
R
o
o
m
T
e
m
p
e
r
a
tu
r
e
.
2
.
Tu
r
n
G
a
s
T
a
p
a
n
d
P
o
w
e
r
O
N
.
3
.
S
e
t
R
o
o
m
T
h
e
r
m
o
s
t
a
t
t
o
a
b
o
v
e
R
o
o
m
Te
m
p
e
r
a
tu
r
e
.
4
.
T
h
e
H
e
a
te
r
i
s
n
o
w
in
A
u
t
o
m
a
t
i
c
M
o
d
e
.
A
f
te
r
a
b
o
u
t
3
0
se
c
o
n
d
s
th
e
R
o
o
m
F
a
n
w
il
l
co
m
e
O
N
.
5
.
S
e
t t
h
e
R
o
o
m
T
h
e
r
m
o
s
t
a
t t
o
t
h
e
d
e
sir
e
d
C
o
m
f
o
r
t
L
e
v
e
l
.
P
R
OD
U
C
T
IO
N
L
A
B
E
L
A
G
A
M
A
K
E
R
S
W
A
R
R
A
N
TY
B
A
D
G
E
M
a
nu
fa
c
t
u
red b
y
S
ee
l
ey
I
nte
r
n
a
tio
n
a
l
7
7
N
or
th
S
t A
lb
u
r
y
N
S
W
2
6
4
0
W
a
r
ran
ty
&
S
e
rv
ice
1
3
00
6
5
0
6
4
4
T
e
c
h
nic
al
S
u
p
po
r
t
1 3
0
0 6
5
0 3
99
GE
N
E
RA
L
A
I
R
O
U
T
S
t
a
nd
a
r
d
100
mm
F
lu
e
O
u
t
l
e
t
S
id
e
P
a
n
e
l
S
pli
t
s
a
long
t
hi
s
lin
e
t
o
gi
ve
L
H
a
nd
RH
op
e
r
a
t
ion
.
1
T
URN
I
N
G T
H
E
H
E
A
TE
R
O
N
FO
R
T
H
E FI
R
ST TI
M
E
S
i
m
pl
y
f
ollow
t
h
es
t
e
p
s
b
e
low
.
1
. E
n
s
u
r
e
t
h
e
g
as
t
a
p
a
tt
h
e
h
ea
t
e
r
i
s
t
u
r
n
e
don
.
2
. T
u
r
n
t
h
e
T
h
e
r
m
o
s
t
a
tt
o
t
h
e
O
N
P
o
s
i
t
ion
.
R
e
f
e
r
t
o
t
h
e
in
s
t
r
u
c
t
ion
s
h
ee
t
in
t
h
e
t
h
e
r
m
o
s
t
a
t
p
acka
g
e
.
3
. S
e
tt
h
e
T
h
e
r
m
o
s
t
a
tt
o
a
bo
ve
t
h
e r
oo
m
t
e
m
p
e
r
a
t
u
r
e
.
4
. T
h
e
h
ea
t
e
r
i
s
now in
a
u
t
o
m
a
t
i
c
m
od
e
.
The combustion fan will start.
After 15 seconds the sparker will commence to spark.
As soon as the heater lights the sparker will stop.
( it will normally take only 1 or 2 sparks for the heater to light )
After a short period of time, the room fan will commence to blow
warm air through the vents.
5
. S
e
tt
h
e
r
oo
m
t
h
e
r
m
o
s
t
a
tt
o
t
h
e
d
es
i
r
e
d
t
e
m
p
e
r
a
t
u
r
e
.
When desired room temperature is reached the gas and combustion
fan will turn off. The room fan will continue to run ( about 2 minutes )
to extract all the heat from the heat exchanger.
M
A
I
N
TE
NANC
E S
CH
E
DU
LE
Periodic maintenance of the heater will ensure a long and satisfactory
service life with the heater operating at optimum performance.
Maintenance should be performed on a yearly basis by an Authorised
person trained in the service of the Braemar Heaters.
If heater does not operate satisfactorily refer to the trouble shooting
chart at the rear of this book or contact your Braemar Dealer.
2
T
R
O
UB
LE S
H
OOTI
N
G
If you have difficulty operating your Heater check the
trouble shooting guide before calling for service
Problem?
H
E
A
TS
hould b
e
O
N
bu
tt
h
e
h
ea
t
e
r
i
s
no
t
wo
r
k
ing
.
Turn the thermostat to the off position, wait 5 seconds set the
thermostat temperature to above room temperature.
The heater should now operate.
Problem?
H
ea
t
e
r
i
s
no
t
op
e
r
a
t
ing
e
ff
ec
t
i
ve
l
y
.
Check that there are enough outlets opened for the fan speed
selected. Is the return air filter blocked ?
We recommend cleaning every fortnight.
Problem?
N
o
t
e
nough
H
ea
t
ing
.
Is the thermostat located in the correct area according
to the Installation Instructions.
Increase the SET temperature.
Problem?
H
ea
t
e
rr
un
s
wh
e
nno
t
p
r
og
r
a
mm
e
d
-
E
l
ec
t
r
oni
c
t
h
e
r
m
o
s
t
a
t
s
.
Check the time AM or PM.
Sleep or away programmed temperature is too high: lower.
FOR SERVICE CALL : 1 300 650 644
3
I
M
PO
R
T
AN
T
Record the Serial No. and Model No. of the heater here.
M
od
e
l
N
o
:
____________________
S
e
r
i
a
l
N
o
:
____________________
D
a
t
e
o
f
I
n
s
t
a
ll
a
t
ion
:
_____
/
______
/
______
I
n
s
t
a
ll
e
r
:
_______________________
SE
R
VI
C
E
B
e
f
o
r
eca
lling
f
o
r
se
r
v
i
ce
h
ave y
ou
:
1
.
C
h
ecke
d
t
h
r
ough
t
h
e
t
r
oubl
es
hoo
t
ing guid
e
.
2
.
N
o
t
e
d
t
h
e
S
e
r
i
a
l
N
o
.
&
M
od
e
l
N
o
.
o
ft
h
e
h
ea
t
e
r
.
( if they are not recorded above, the numbers are
located on the side of the heater. )
3
. S
po
ke
n
t
o
y
ou
r
B
r
ae
m
a
r
D
ea
l
e
r
/ I
n
s
t
a
ll
e
r
.
FO
R
SE
R
VI
C
E
CA
LL
:
1 300 650 644
ECN1100 Doc. No. 613949 /c
Specialty Press
xref0091 August 04
Manufacturers and Designers of Technically Advanced Quality Heating and Cooling Products
Seeley International Pty Ltd has a policy of continuous product development and therefore
reserves the right to make changes to these specifications without notice. Whilst every
care has been taken to assure accuracy of the data compiled in the document,
Seeley International Pty Ltd does not assume any liability for errors and/or omissions.
Braemar is a registered trademark of Braemar Industries Pty Ltd.
Seeley International Pty Ltd ACN 23 054 687 035
Albury Manufacturing
77 North Street Albury, NSW 2640
www.seeley.com.au
TECHNICAL SUPPORT CENTRE: 1300 650 399
For technical support regarding
the installation of this product
SALES: 1300 650 141
For all your sales enquiries
SERVICE: 1300 650 644
For all your Braemar warranty and service needs.
Or
Contact your local Braemar direct dealer.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Braemar Ducted Gas TB TE TX Owner's manual

Category
Split-system air conditioners
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI