Invacare IRC5PO2W User manual

Category
Oxygen Equipment
Type
User manual

This manual is also suitable for

Dealer: This manual MUST be given to the end
user of this product.
User:
BEFORE using this product, read this
manual and save for future reference.
User Manual
For more information regarding
Invacare products, parts, and services,
please visit www.invacare.com
Perfecto
2
Series
Oxygen Concentrators without SensO
2
®,
Oxygen Concentrators with SensO
2
HomeFill
®
Compatible
Perfecto
2
with SensO
2
Model IRC5PO2
Model IRC5PO2W
Model IRC5PO2V
Perfecto
2
Model IRC5P
Model IRC5PW
WARNING
Perfecto
2
Series 2 Part No 1143482
WARNING
DO NOT USE THIS PRODUCT OR ANY AVAILABLE
OPTIONAL EQUIPMENT WITHOUT FIRST
COMPLETELY READING AND UNDERSTANDING
THESE INSTRUCTIONS AND ANY ADDITIONAL
INSTRUCTIONAL MATERIAL SUCH AS OWNER’S
MANUALS, SERVICE MANUALS OR INSTRUCTION
SHEETS SUPPLIED WITH THIS PRODUCT OR
OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO
UNDERSTAND THE WARNINGS, CAUTIONS OR
INSTRUCTIONS, CONTACT A HEALTHCARE
PROFESSIONAL, DEALER OR TECHNICAL
PERSONNEL BEFORE ATTEMPTING TO USE THIS
EQUIPMENT - OTHERWISE, INJURY OR DAMAGE
MAY OCCUR.
ACCESSORIES WARNING
Invacare products are specifically designed and
manufactured for use in conjunction with Invacare
accessories. Accessories designed by other manufacturers
have not been tested by Invacare and are not
recommended for use with Invacare products.
ACCESSORIES
Therearemanydifferenttypesofhumidifiers,oxygentubing,
cannulasandmasksthatcanbeusedwiththisdevice.You
shouldcontactyourlocalhomecareproviderfor
recommendationsonwhichofthesedeviceswillbebestfor
you.Theyshouldalsogiveyouadviceontheproperusage,
maintenance,andcleaning.
NOTE:Updatedversionsofthismanualcanbefoundat
www.invacare.com.
TABLE OF CONTENTS
Part No 1143482 3 Perfecto
2
Series
Table of Contents
ACCESSORIES .................................................. 2
SPECIAL NOTES ............................................... 4
LABEL LOCATION ............................................ 6
SECTION 1—GENERAL GUIDELINES .................. 7
To Reduce the Risk of Burns, Electrocution, Fire or Injury to
Persons ......................................................................................................... 7
Operating Information ....................................................................... 8
Radio Frequency Interference.......................................................... 8
SECTION 2—FEATURES .................................. 10
SECTION 3—HANDLING ................................. 11
Unpacking............................................................................................11
Inspection............................................................................................11
Storage.................................................................................................11
SECTION 4—TYPICAL PRODUCT
PARAMETERS ............................................... 12
SECTION 5—OPERATING INSTRUCTIONS ....... 15
Introduction........................................................................................15
Select a Location ...............................................................................15
Set Up ..................................................................................................16
Power Switch .....................................................................................18
Flowrate...............................................................................................19
Front Panel Indicators - Units with SensO2 ...............................20
Front Panel Indicators - Units without SensO2.........................21
SECTION 6—MAINTENANCE .......................... 23
Routine Maintenance........................................................................23
SECTION 7—TROUBLESHOOTING GUIDE ......... 26
LIMITED WARRANTY .................................... 31
SPECIAL NOTES
Perfecto
2
Series 4 Part No 1143482
SPECIAL NOTES
Signalwordsareusedinthismanualandapplytohazardsor
unsafepracticeswhichcouldresultinpersonalinjuryor
propertydamage.Refertothefollowingtablefordefinitions
ofthesignalwords.
NOTICE
Theinformationcontainedinthisdocumentissubjectto
changewithoutnotice.
DANGER
DO NOT SMOKE while using this device. Keep all
matches, lighted cigarettes or other sources of ignition
out of the room in which this product is located and away
from where oxygen is being delivered.
NO SMOKING signs should be prominently displayed.
Textiles and other materials that normally would not
burn are easily ignited and burn with great intensity in
oxygen enriched air. Failure to observe this warning can
result in severe fire, property damage and cause physical
injury or death.
SIGNAL WORD MEANING
DANGER
Danger indicates an imminently hazardous situation
which, if not avoided, will result in death or serious
injury.
WARNING
Warning indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury.
CAUTION
Caution indicates a potentially hazardous situation
which, if not avoided, may result in property
damage or minor injury or both.
SPECIAL NOTES
Part No 1143482 5 Perfecto
2
Series
CAUTION
“Caution:Federallawrestrictsthisdevicetosaleorrentalby
oronorderofaphysician,oranyotherpractitionerlicensed
bythelawoftheStateinwhichhe/shepracticestouseor
ordertheuseofthisdevice.”
Invacarerecommendsanalternatesourceofsupplemental
oxygenintheeventofapoweroutage,alarmconditionor
mechanicalfailure.Consultyourphysicianorequipment
providerforthetypeofreservesystemrequired.
Thisequipmentistobeusedasanoxygensupplementandis
notconsideredlifesupportingorlifesustaining.
LABEL LOCATION
Perfecto
2
Series 6 Part No 1143482
LABEL LOCATION
FOR OPERATING INSTRUCTIONS or ALARMS (See Operator’s Manual)
DANGER - ELECTRIC SHOCK
DANGER - RISK OF FIRE
NO SMOKING - Keep ALL sources of ignition out of the room in which this product is located and
away from areas where oxygen is being delivered. Textiles, oil and other combustibles are easily
ignited and burn with great intensity in oxygen enriched air.
DO NOT remove cover. Refer servicing to qualied service personnel.
Flowrates below 0.5 L/min. will trigger Low Flow Alarm (rapid audible alarm).
Set owmeter at 3.0 L/min. or less when lling HomeFill® cylinders.
P
/
N
1
1
4
7
9
2
0
R
e
v
.
B
HomeFill®
Compatible
CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.
Perfecto
2
Serial Number Label is
located on the resonator
intake assembly
Specification Label is
located on the back
near the bottom
SECTION 1—GENERAL GUIDELINES
Part No 1143482 7 Perfecto
2
Series
SECTION 1—GENERAL GUIDELINES
Inordertoensurethesafeinstallation,assemblyand
operationofthePerfecto
2
concentratortheseinstructions
MUSTbefollowed.
WARNING
Thissectioncontainsimportantinformationforthesafe
operationanduseofthisproduct.
To Reduce the Risk of Burns,
Electrocution, Fire or Injury to Persons
DANGER
Risk of electric shock. DO NOT disassemble. Refer servicing
to qualified service personnel. No user serviceable parts.
Avoid using while bathing. If continuous usage is required
by the physician’s prescription, the concentrator MUST be
located in another room at least 7 ft from the bath.
DO NOT come in contact with the concentrator while wet.
DO NOT place or store product where it can drop into
water or other liquid.
DO NOT reach for product that has fallen into water.
Unplug IMMEDIATELY.
If the concentrator has a damaged cord or plug, if it is not
working properly, if it has been dropped or damaged, or
dropped into water, call qualified technician for
examination and repair.
A spontaneous and violent ignition may occur if oil, grease
or greasy substances come in contact with oxygen under
pressure. These substances MUST be kept away from the
oxygen concentrator, tubing and connections, and all
other oxygen equipment. DO NOT use any lubricants
unless recommended by Invacare.
Avoid creation of any spark near medical oxygen
equipment. This includes sparks from static electricity
created by any type of friction.
SECTION 1—GENERAL GUIDELINES
Perfecto
2
Series 8 Part No 1143482
Operating Information
Foroptimumperformance,Invacarerecommendsthateach
concentratorbeonandrunningforaminimumof30minutes
atatime.Shorterperiodsofoperationmayreducemaximum
productlife.
Keeptheoxygentubing,cord,andunitoutfromundersuch
itemsasblankets,bedcoverings,chaircushions,clothingand
awayfromheatedorhotsurfaces,includingspaceheaters,
stovesandsimilarelectricalappliances.
DONOTmoveorrelocateconcentratorbypullingonthe
powercord.
NEVERdroporinsertanyobjectorliquidintoanyopening.
InvacarerecommendsthatCrushProofoxygentubingbe
usedwiththisproductandnotexceed50ftinlength.
Therearenouserserviceableparts.Thisdoesnotinclude
normalmaintenanceitems.Seemaintenancesectionforuser
maintenanceitems.
AproductshouldNEVERbeleftunattendedwhenplugged
in.MakesurethePerfecto
2
isOffwhennotinuse.
Closesupervisionisnecessarywhenthisproductisusednear
childrenorphysicallychallengedindividuals.
Additionalmonitoringorattentionmayberequiredfor
patientsusingthisdevicewhoareunabletohearorsee
alarmsorcommunicatediscomfort.
DONOTconnecttheconcentratorinparallelorserieswith
otheroxygenconcentratorsoroxygentherapydevices.
Radio Frequency Interference
Thisequipmenthasbeentestedandfoundtocomplywith
EMClimitsspecifiedbyIEC/EN6060112.Theselimitsare
designedtoprovideareasonableprotectionagainst
electromagneticinterferenceinatypicalmedicalinstallation.
SECTION 1—GENERAL GUIDELINES
Part No 1143482 9 Perfecto
2
Series
Otherdevicesmayexperienceinterferencefromev en thelow
levelsofelectromagneticemissionspermittedbytheabove
standards.TodetermineiftheemissionsfromthePerfecto
2
is
causingtheinterference,turnthePerfecto
2
Off.Ifthe
interferencewiththeotherdevice(s)stops,thenthePerfecto
2
iscausingtheinterference.Insuchrarecases,interference
maybereducedorcorrectedbyoneofthefollowing
measures:
•Reposition,relocate,orincreasetheseparation
betweentheequipment.
Connecttheequipmentintoanoutletonacircuit
differentfromthattowhichtheotherdevice(s)is
connected.
SECTION 2—FEATURES
Perfecto
2
Series 10 Part No 1143482
SECTION 2—FEATURES
Oxygen Outlet
Flowmeter
Oxygen Purity Indicator
Lights / Fault and Power
Indicator Lights
Power Switch
Circuit Breaker
Elapsed Time
Meter
Cabinet Filter
REAR VIEW
ACCESSORIES (NOT SHOWN):
PreciseRX™ Pediatric Humidifier/Flowmeter
Accessory - IRCPF16 (Perfecto
2
5 Only)
HomeFill home oxygen compressor - IOH200
*Outlet
Fitting
Power
Cord
*NOTE:Thisoutletfittingistobe
usedonlyforfillingoxygencylinders
withtheHomeFillhomeoxygen
compressor.Theoutletfittingdoesnot
affectconcentratorperformance.
RefertotheHomeFillownerʹs
manual,partnumber1100873,for
connectionandoperating
instructions.Whennotinuse,the
plugprovidedwiththeconcentrator
shouldbeinsertedintotheoutlet
fitting.Formoreinformationabout
theHomeFill,contactyourInvacare
dealer.
SECTION 3—HANDLING
Part No 1143482 11 Perfecto
2
Series
SECTION 3—HANDLING
TheconcentratorshouldALWAYSbekeptintheupright
positiontopreventcabinetdamagewhilebeingtransported.
Iftheconcentratoristobereshippedbycommoncarrier,
additionalcartonsareavailablefromInvacare.
Unpacking
NOTE:Forthisprocedure,refertoFIGURE3.1.
1. Checkforanyobvious
damagetothecartonor
itscontents.Ifdamageis
evident,notifythe
carrier,oryourlocal
dealer.
2. Removeallloosepacking
fromthecarton.
3. Carefullyremoveallthe
componentsfromthe
carton.
FIGURE 3.1 Unpacking
NOTE:Unlesstheoxygenconcentratoristobeusedimmediately,
retaincontainersandpackingmaterialsforstorageuntiluseofthe
concentratorisrequired.
Inspection
Inspect/examineexterioroftheoxygenconcentratorfornicks,
dents,scratchesorotherdamages.Inspectallcomponents.
Storage
1. Storetherepackagedoxygenconcentratorinadryarea.
2. DONOTplaceobjectsontopofrepackagedconcentrator.
SECTION 4—TYPICAL PRODUCT PARAMETERS
Perfecto
2
Series 12 Part No 1143482
SECTION 4—TYPICAL PRODUCT
PARAMETERS
Electrical Requirements: 120 VAC ± 10% (132 VAC/108 VAC), 60 Hz
Rated Current Input: 3 A
Sound Level: 43 ± 2 dBA Average for Perfecto
2
Models and
Perfecto
2
V Model
40 ± 2 dBA Average for Perfecto
2
W Models
Altitude: All Perfecto
2
Models: Up to 8,000 ft (2438
meters) above sea level without degredation of
concentration levels. From 8,000 ft to 13,129
(4000 meters) below 90% efficiency.
All Perfecto
2
Models while filling a
HomeFill System: Up to 6,000 ft (1828 meters)
above sea level without degradation of
concentration levels. From 6,000 ft (1828 meters)
to 13,129 ft (4000 meters) below 90% efficiency.
*Oxygen Output
Concentration Levels:
87% to 95.6% for flows ranging at 0.5 to 5 L/min
Maximum Outlet Pres-
sure:
5 psi ± 0.5 psi (34.5 kPa ± 3.45 kPa)
Flow Range: 0.5 to 5 L/min
For flowrates less than 1 L/min, we recommend
the use of the Invacare Pediatric Flowmeter
IRCPF16 Accessory.
Low Flow Alarm: 0 L/min to 0.5 L/min
Rapid Audible Alarm Beeping (No Accessories
Connected).
Average Power
Consumption:
Perfecto
2
and Perfecto
2
W Models: 280 W
(Operating @ 3 L/min)
Perfecto
2
V Model: 325 W
Pressure Relief Mecha-
nism Operational at:
35 psi ± 3.5 psi (241 kPa ± 24.1 kPa)
SECTION 4—TYPICAL PRODUCT PARAMETERS
Part No 1143482 13 Perfecto
2
Series
Change in maximum
recommended flow when
back pressure of 7kPa is
applied:
0.7 L/min
Filters: Cabinet, Outlet HEPA and Compressor Inlet
Safety System: Current overload or line surge shutdown. High
temperature compressor shutdown. High
Pressure Alarm w/compressor shutdown. Low
Pressure Alarm w/compressor shutdown.
Battery Free Power Loss Alarm. SensO
2
Oxygen
System (SensO
2
Model) Low Flow Alarm.
Width: 15 in ± 3/8 in (38.1 cm ± 1 cm)
Height: 23 in ± 3/8 in (58.4 cm ± 1 cm)
Depth: 12 in ± 3/8 in (30.5 cm ± 1 cm)
Weight: 43 lbs ± 2 lbs (19.5 kg ± 1 kg) Perfecto
2
Models
45 lbs ± 2 lbs (20.5 kg ± 1 kg) Perfecto
2
W Models
40 lbs ± 2 lbs (18.1 kg ± 1 kg) Perfecto
2
V Model
Shipping Weight: 48 lbs ± 2 lbs (21.8 kg ± 1 kg) Perfecto
2
Models
50 lbs ± 2 lbs (22.8 kg ± 1 kg) Perfecto
2
W Models
45 lbs ± 2 lbs (20.4 kg ± 1 kg) Perfecto
2
V Model
Operating Ambient
Temperature:
50°F - 95°F (10°C - 35°C) at 20-60% relative
humidity Perfecto
2
Models and Perfecto
2
V Model
50°F - 90°F (10°C - 32°C) at 20-60% relative
humidity Perfecto
2
W Models
Exhaust: Less than Ambient + 35°F (+19°C)
Oxygen Output
Temperature:
Less than Ambient + 6°F (+3°C)
Cabinet: Impact Resistant flame-retardant plastic cabinet
that conforms to UL94V-0.
Regulatory Listing: Double Insulated Product ETL certified
complying with UL1431 and UL1097 ETL certified
to CSA C22.2 No. 68.
Electrical: No extension cords.
SECTION 4—TYPICAL PRODUCT PARAMETERS
Perfecto
2
Series 14 Part No 1143482
*NOTE:Statedconcentrationlevelsachievedafterinitialwarmup
period(approximately30minutes).
Placement: No closer than three inches from any wall,
furniture, draperies, or similar surfaces.
Tubing: 7 ft cannula with a maximum 50 ft of Crush-Proof
Tubing (DO NOT pinch).
Relative Humidity: 20 to 60%
Time of Operation: Up to 24 hours per day.
Recommended Storage
and Shipping Tempera-
ture:
-20°F to 150°F (-29°C to 65°C), at 15-95%
relative humidity.
SECTION 5—OPERATING INSTRUCTIONS
Part No 1143482 15 Perfecto
2
Series
SECTION 5—OPERATING
INSTRUCTIONS
Introduction
Youroxygenconcentratorisintendedforindividualuse
indoors.Itisanelectronicallyoperateddevicethatseparates
oxygenfromroomair.Itprovideshighconcentrationofoxygen
directlytoyouthroughanasalcannula.Clinicalstudieshave
documentedthatoxygenconcentratorsaretherapeutically
equiv alent toothe r typesofoxygendeliv erysystems.
Yourproviderwillshowyouhowtouseyouroxygen
concentrator.He/Sheshouldbecontactedwithanyquestions
orproblemsregardingyouroxygenconcentrator.This
ownersmanualwilltellyouaboutyourconcentratorandwill
serveasareferenceasyouuseyourconcentrator.
Select a Location
WARNING
NEVERblocktheairopeningsoftheproductorplaceitona
softsurface,suchasabedorcouch,wheretheairopeningmay
beblocked.Keeptheopenings freefromlint,hairandthelik e.
Keepunitatleast3inchesawayfromwalls,draperies,
furniture,andthelike.
Youmayse le ct aroomwhereusingyouroxygenconcentrator
wouldbemostconvenient.Yourconcentratorcanbeeasily
rolledfromroomtoroomonitscasters.
Youroxygenconcentratorwillperformbestwhenoperated
underthefollowingconditions.RefertoTypicalProduct
Parametersonpage 12.Usageinenvironmentsotherthan
thosedescribedmayresultintheneedforincreased
equipmentmaintenance.Theairintakeoftheunitshouldbe
locatedinawellventilatedareatoavoidsmoke,airborne
pollutantsand/orfumes.DONOTplaceinacloset.
SECTION 5—OPERATING INSTRUCTIONS
Perfecto
2
Series 16 Part No 1143482
Set Up
Plug in Power Cord
Pluginpowercordtoanelectricaloutlet.
Connect Humidifier (If So Prescribed)
WARNING
DONOToverfillhumidifier.
DONOTreversetheoxygeninputandoutputconnections.
Waterfromthehumidifierbottlewilltravelthroughthe
cannulabacktothepatient.
NOTE:Forthisprocedure,refertoFIGURE5.1,FIGURE5.2on
page 17,FIGURE5.3onpage 18.
1. Removecapfrombottle.
2. Fillhumidifierwithdistilledwatertothelevelindicated
bythemanufacturer.Replacethehumidifiercapand
securelytighten.
FIGURE 5.1 Filling the Humidifier
3. Insertaflatheadscrewdriverintheplategrooveonthetop
edgeofthefilteraccessdoorandgentlyprythefilter
accessdooroff(FIGURE5.2).
4. Pullupandremovethehumidifierbottleadapter
(FIGURE5.2).
Humidifier
Bottle w/o Cap
Humidifier
Bottle with Cap
SECTION 5—OPERATING INSTRUCTIONS
Part No 1143482 17 Perfecto
2
Series
FIGURE 5.2 Humidifer Bottle Adapter
5. Attachthehumidifierbottleadaptertothehumidifier
bottlebyturningthewingnutonthehumidifierbottle
counterclockwiseuntilitissecurelyfastened.SeeDetail
“A inFIGURE5.3.
6. Placethehumidifierbottle/adapterassemblyinthe
humidifiercompartmentontheconcentrator.SeeDetail
“B”inFIGURE5.3.
7. Attachoxygentubingfromthehumidifierbottle/adapter
assemblytooxygenoutletconnectorontheconcentrator.
SeeDetail“B”inFIGURE5.3.
8. Attachthecannula/patientsupplytubingtothe
humidifierbottleoutlet.SeeDetail“B”inFIGURE5.3.
9. Afterassembly,ensurethatoxygenisflowingthroughthe
cannula.
Filter Access Door
Cabinet Filter
Humidifier
Bottle Adapter
Insert Flat Head
Screwdriver
Here
SECTION 5—OPERATING INSTRUCTIONS
Perfecto
2
Series 18 Part No 1143482
FIGURE 5.3 Humidifier Compartment
Power Switch
NOTE:Forthisprocedure,referto
FIGURE5.4.
1. Presspowerswitchtoon
position.Allthepanel
lightsandtheaudible
alarmwillcomeon for
onesecond,indicating
thattheunitisfunctioning
properly.
FIGURE 5.4 Power Switch
Humidifier
Bottle
Humidifier
Compartment
Humidifier
Bottle
Adapter
Humidifier
Bottle
DETAIL “A”
DETAIL “B”
Oxygen
Tubing
Oxygen Outlet
Connector
Humidifier
Bottle
Outlet
On/Off
(I/O)
Power
Switch
SECTION 5—OPERATING INSTRUCTIONS
Part No 1143482 19 Perfecto
2
Series
Flowrate
NOTE:Forthisprocedure,refertoFIGURE5.5onpage 20.
1. Turntheflowrateknobtothesettingprescribedbyyour
physicianortherapist.
CAUTION
Neversettheflowgreaterthan5L/min.
WARNING
DONOTchangetheL/minsettingontheflowmeterunlessa
changehasbeenprescribedbyyourphysicianortherapist.
NOTE:Toproperlyreadtheflowmeter,locatetheprescribedflowrate
lineontheflowmeter.Next,turntheflowknobuntiltheballrisesto
theline.Now,centertheballontheL/minlineprescribed.
2. Iftheflowrateontheflowmetereverfallsbelow0.5L/min
formorethanaboutoneminute,theLOWFLOWalarm
willbetriggered.Thisisarapidbeepingoftheaudible
alarm.Checkyourtubingoraccessoriesforblockedor
kinkedtubingoradefectivehumidifierbottle.Afterrated
flowisrestored,between0.5L/minand0.75L/min,the
LOWFLOWaudiblealarmwillturnoff.
NOTE:Theuseofsomeaccessoriessuchasthepediatricflowstand
andtheHomeFillcompressorwilldeactivatetheLowFlowAlarm.
SECTION 5—OPERATING INSTRUCTIONS
Perfecto
2
Series 20 Part No 1143482
FIGURE 5.5 Flowrate
Front Panel Indicators - Units with
SensO
2
TheSensO
2
featuremonitorsthepurityofoxygengenerated
bytheoxygenconcentrator.Ifpurityfallsbelowfactorypreset
standards,indicatorlightsonthecontrolpanelwill
illuminate.
FIGURE 5.6 Front Panel Indicators - Units with SensO2
Flow Knob
Ball
Flowmeter
Front Panel
0.5 L/min
O
2
Auto Shut Down
Use Backup
Below
Normal
Normal
RED
Call Supplier
YELLOW
GREEN
OXYGEN PURITY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Invacare IRC5PO2W User manual

Category
Oxygen Equipment
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI