CSI Pure Digital Fiberlink 7222 is a transmitter unit that provides 4 optical outputs of RGBHV video with stereo audio. Each output transmits over one single mode or multimode fiber at 1310 nm wavelength. The unit is designed to provide point-to-multipoint signal distribution and is compatible with all receiver units within the 7220 Series. The unit’s all digital encoding delivers noise-free transmissions that retain all of their initial parameters, regardless of fiber optic cable attenuation.

CSI Pure Digital Fiberlink 7222 is a transmitter unit that provides 4 optical outputs of RGBHV video with stereo audio. Each output transmits over one single mode or multimode fiber at 1310 nm wavelength. The unit is designed to provide point-to-multipoint signal distribution and is compatible with all receiver units within the 7220 Series. The unit’s all digital encoding delivers noise-free transmissions that retain all of their initial parameters, regardless of fiber optic cable attenuation.

P/N: 123189 Rev. B
Models 7222, 7224 and 7226
RGBHV Video with
Stereo Audio
USER’S MANUAL
WORLD HEADQUARTERS
55 Cabot Court
Hauppauge, N.Y. 11788 USA
Tel: (631) 273-0404 Fax: (631) 273-1638
www.commspecial.com
Communications Specialties Pte Ltd
100 Beach Road
#22-09 Shaw Tower
Singapore 189702
Tel: +65 6391 8790 Fax: +65 6396 0138
General Information ................................................... 2
Introduction ............................................................ 2
Technical Specifications ......................................... 2
Installation Instructions .............................................. 4
Installation Procedure ............................................. 4
System Connections ............................................... 5
Indicator LEDs ....................................................... 6
Operating Pointers and Troubleshooting ................... 6
Maintenance and Repairs ........................................... 7
Limited Warranty ....................................................... 8
CONTENTS
1
8
LIMITED WARRANTY
Communications Specialties, Inc. (CSI) warrants that for a period of
three years after purchase by the Buyer, the Pure Digital Fiberlink
®
7222, 7224 and 7226 transmitters will be free from defects in material
and workmanship under normal use and service. A Return Material Au-
thorization (RMA) number must be obtained from CSI before any equip-
ment is returned by the Buyer. CSIs obligation under this warranty
will be limited, at its option, to either the repair or replacement of de-
fective units, including free materials and labor. In no event shall CSI
be responsible for any incidental or consequential damages or loss of
profits or goodwill. CSI shall not be obligated to replace or repair equip-
ment that has been damaged by fire, war, acts of God, or similar causes,
or equipment that has been serviced by unauthorized personnel, altered,
improperly installed or abused.
RMA numbers and repairs can be obtained from:
Communications Specialties, Inc.
55 Cabot Court
Hauppauge, NY 11788 USA
Tel: (631) 273-0404 Fax: (631) 273-1638
www.commspecial.com Email: info@commspecial.com
Or, in the Asia Pacific Region:
Communications Specialties Pte Ltd
100 Beach Road, #22-09 Shaw Tower
Singapore 189702
Tel: +65 6391 8790 Fax: +65 6396 0138
Email: csiasia@commspecial.com
Please have your serial number (located on the top label of the unit)
available with contacting us.
GENERAL INFORMATION
The Pure Digital Fiberlink
®
7222, 7224 and 7226 transmitter units
provide 4, 8 and 12 optical outputs respectively of RGBHV video with
stereo audio. Each output transmits over one single mode or multimode
fiber at 1310 nm wavelength. The units are designed to provide point-
to-multipoint signal distribution and are compatible with all receiver
units within the 7220 Series.
The unitsall digital encoding delivers noise-free transmissions that
retain all of their initial parameters, regardless of fiber optic cable at-
tenuation. System operation may be easily monitored using integral in-
dicator LEDs on each unit that continuously signify the presence of
baseband video and audio signals.
Introduction
Technical Specifications
Model Part Number Configurations:
All units transmit at
1310 nm wavelength
over single mode or
multimode fiber. ST
connectors are
provided.
Video:
Input Impedance ....................... RGB: 75 Ohms; H&V: Hi-Z
Input Level ............................... RGB: 714 mV p-p; H&V: 3 to 5 V p-p
H Sync Frequency Range ......... 31.5 to 60 kHz
V Sync Frequency Range ......... 30 to 85 Hz
Number of Video Channels ...... 1 RGBHV
RGB Format Supported ............ RGB with separate H and V
Unit Type Part Number
Four output transmitter 7222-7S-PP*
Eight output transmitter 7224-7S-PP*
Twelve output transmitter 7226-7S-PP*
*PP Values (line cord): NA = N. America, AU = Australia,
EU = Europe, JP = Japan, UK = United Kingdom
2
Therefore, any minute particles of dirt or dust can easily block the fiber
from accepting or radiating light. To prevent this from happening, al-
ways use the provided dust caps whenever optical connectors are ex-
posed to air. It is also a good idea to gently clean the tip of an optical
connector with a lint-free cloth moistened with alcohol whenever dust
is suspected.
The status of the VIDEO and AUDIO indicator LEDs should provide
the first clue as to the origin of an operational failure. If these are off, it
usually means that the fiber is broken or has too much attenuation. Next,
be certain that the input and output signal connections are correct.
If, after reviewing the above possibilities, the system is still not oper-
ating, please contact the Customer Service Department for further as-
sistance.
MAINTENANCE AND REPAIRS
The Pure Digital Fiberlink
®
7222, 7224 and 7226 transmitters have
been manufactured using the latest semiconductor devices and tech-
niques that electronic technology has to offer. They have been designed
for long, reliable and trouble-free service and are not normally field
repairable. Should difficulty be encountered, Communications Special-
ties maintains a complete service facility to render accurate, timely and
reliable service of all products.
The only maintenance that can be provided by the user is to ascertain
that the optical connectors are free of dust or dirt that could interfere
with light transmission and that electrical connections are secure and
accurate. DANGER! Always turn off the transmitter’s power before
removing the optical fiber from the unit!
All other questions or comments should be directed to our Customer
Service Department. It should be noted that manyproblems” can eas-
ily be solved by a simple phone call.
7
Miscellaneous:
Operating Temp. Range ........... -20 to +50 degrees C
Operating Power ...................... 95-250 volts AC, 47-63 Hz, 9 watts
Signal Connectors ................................ HD-15F
RGB Processing ................................... 24 bits, no compression or
scaling
Optical:
Operating Wavelength ......................... 1310 nm; MM or SM
Optical Fiber ........................................ 62.5/125 microns MM,
50/125 microns MM or
8-10/125 microns SM
Optical Connector ................................ ST
Class I Laser Product complies with FDA performance standard for
laser products, Title 21, Code of Federal Regulations, Sub-Chapter J
Audio:
Number of Audio Channels .................. 2, unbalanced
Frequency Response ............................. +0/-0.5 dB, 20 Hz to 20 kHz
Input Impedance ................................... >24 k Ohms
Output Impedance ................................ <1 Ohm
Maximum Audio Level ........................ +10 dBu
THD+N ................................................. 0.005%; 20 Hz - 20 kHz
SNR (A-Weighted) ............................... 95 dB
Channel Phase Differential ................... +/-0.1
o
Crosstalk ............................................... Min. 95 dB (1 kHz)
Signal Connectors ................................ 3.5mm Stereo jack
Audio to Video Diff. Delay (skew) ..... <300 uS
3
Power: ON: (GREEN) Indicates that correct power has been applied.
Video: OFF: Indicates no video detected on the input.
BLINKING GREEN: Indicates either H or V sync detected at
the input but not both.
STEADY GREEN: Indicates both H and V sync detected on
the input.
Audio: OFF: Indicates no audio detected on the transmitter unit.
BLINKING: Indicates audio detected on the transmitter unit.
Indicator LEDs:
The Pure Digital Fiberlink
®
7222, 7224 and 7226
transmitters each have three integral indicator LEDs that are used to
monitor the state of the unit.
The status of the LEDs are as follows:
OPERATING POINTERS AND TROUBLESHOOTING
Optical Fiber:
The 7222, 7224 and 7226 transmitters operate with most
multimode (MM) and single mode (SM) optical fibers. All models within
the 7220 Series use the same 1310 nm wavelength and optics for trans-
mitting over multimode or single mode fiber, but be aware that the type
of fiber you use will affect the system’s loss budget and the maximum
transmission distance that it can support.
Troubleshooting:
Multimode fiber optic cable contains an optical fiber with a light
carrying corethat is only .0025 inches (62.5 microns) in diameter.
Single mode fiber optic cable has an even smaller “core,” only .00032
to .0004 inches (8-10 microns). This is smaller than a human hair!
6
INSTALLATION INSTRUCTIONS
Installation Procedure:
The Pure Digital Fiberlink
®
7222, 7224 and 7226 units are ready for
immediate use. Each model features indicator LEDs for monitoring pur-
poses. The following instructions describe the typical installation pro-
cedure and the function of the LED indicators.
1. Connect the video source to the video INPUT RGBHV connector on
the transmitter unit.
2. Connect the audio input signals to the transmitter AUDIO jack.
3. Optionally, connect the LOOP THROUGH RGBHV output to a com-
puter monitor or other destination.
4. Optionally, connect the LOOP THROUGH AUDIO output to speakers
or other destination.
Loss Budget and Maximum Transmission Distance:
Wavelength Loss Budget (in dB) Distance* (in km)
1310 MM 0-15 0-0.75
1310 SM 0-15 0-30
*Distance specifications are only approximate and are not
guaranteed. Operating loss budget must not be exceeded.
DANGER! The transmitting element in the Pure Digital Fiberlink 7222, 7224 and
7226 transmitter units contain solid state Laser Diodes located within the
optical connectors. These lasers emit invisible infrared electromagnetic
radiation which can be harmful to human eyes. The radiation from these optical
connectors, if viewed at close range without a fiber optic cable connected to
the optical connector, may be of sufficient intensity to cause instantaneous
damage to the retina of the eye. Direct viewing of this radiation should be avoided
at all times.
4
5. Connect fiber optic cable(s) between each optical output that will be
used and a corresponding Pure Digital Fiberlink 7220 Series receiver
unit. BE SURE TO LEAVE PROTECTIVE CAPS ON ANY OUT-
PUTS THAT WILL NOT BE USED.
6. Turn unit on, causing the green POWER LED to light.
7. The VIDEO and AUDIO LEDs will give an indication as described
on the following page.
8. The system should now be operational.
System Connections:
The input and output connections for the Pure Digital Fiberlink
®
7222, 7224 and 7226 models are as follows:
Audio Connector INPUT and LOOP-THRU: 3.5mm stereo jack
Video Connector INPUT and LOOP-THRU: HD-15F connector
Video Pin Out: Input Loop-Through
1 Red In Red Out
2 Green In Green Out
3 Blue In Blue Out
4 N/C N/C
5 Ground Ground
6 Ground Ground
7 Ground Ground
8 Ground Ground
9 N/C N/C
10 Ground Ground
11 N/C N/C
12 N/C N/C
13 Hor. Sync. In Hor. Sync Out
14 Vert. Sync In Vert. Sync Out
15 N/C N/C
5
INSTALLATION INSTRUCTIONS
Installation Procedure:
The Pure Digital Fiberlink
®
7222, 7224 and 7226 units are ready for
immediate use. Each model features indicator LEDs for monitoring pur-
poses. The following instructions describe the typical installation pro-
cedure and the function of the LED indicators.
1. Connect the video source to the video INPUT RGBHV connector on
the transmitter unit.
2. Connect the audio input signals to the transmitter AUDIO jack.
3. Optionally, connect the LOOP THROUGH RGBHV output to a com-
puter monitor or other destination.
4. Optionally, connect the LOOP THROUGH AUDIO output to speakers
or other destination.
Loss Budget and Maximum Transmission Distance:
Wavelength Loss Budget (in dB) Distance* (in km)
1310 MM 0-15 0-0.75
1310 SM 0-15 0-30
*Distance specifications are only approximate and are not
guaranteed. Operating loss budget must not be exceeded.
DANGER! The transmitting element in the Pure Digital Fiberlink 7222, 7224 and
7226 transmitter units contain solid state Laser Diodes located within the
optical connectors. These lasers emit invisible infrared electromagnetic
radiation which can be harmful to human eyes. The radiation from these optical
connectors, if viewed at close range without a fiber optic cable connected to
the optical connector, may be of sufficient intensity to cause instantaneous
damage to the retina of the eye. Direct viewing of this radiation should be avoided
at all times.
4
5. Connect fiber optic cable(s) between each optical output that will be
used and a corresponding Pure Digital Fiberlink 7220 Series receiver
unit. BE SURE TO LEAVE PROTECTIVE CAPS ON ANY OUT-
PUTS THAT WILL NOT BE USED.
6. Turn unit on, causing the green POWER LED to light.
7. The VIDEO and AUDIO LEDs will give an indication as described
on the following page.
8. The system should now be operational.
System Connections:
The input and output connections for the Pure Digital Fiberlink
®
7222, 7224 and 7226 models are as follows:
Audio Connector INPUT and LOOP-THRU: 3.5mm stereo jack
Video Connector INPUT and LOOP-THRU: HD-15F connector
Video Pin Out: Input Loop-Through
1 Red In Red Out
2 Green In Green Out
3 Blue In Blue Out
4 N/C N/C
5 Ground Ground
6 Ground Ground
7 Ground Ground
8 Ground Ground
9 N/C N/C
10 Ground Ground
11 N/C N/C
12 N/C N/C
13 Hor. Sync. In Hor. Sync Out
14 Vert. Sync In Vert. Sync Out
15 N/C N/C
5
Miscellaneous:
Operating Temp. Range ........... -20 to +50 degrees C
Operating Power ...................... 95-250 volts AC, 47-63 Hz, 9 watts
Signal Connectors ................................ HD-15F
RGB Processing ................................... 24 bits, no compression or
scaling
Optical:
Operating Wavelength ......................... 1310 nm; MM or SM
Optical Fiber ........................................ 62.5/125 microns MM,
50/125 microns MM or
8-10/125 microns SM
Optical Connector ................................ ST
Class I Laser Product complies with FDA performance standard for
laser products, Title 21, Code of Federal Regulations, Sub-Chapter J
Audio:
Number of Audio Channels .................. 2, unbalanced
Frequency Response ............................. +0/-0.5 dB, 20 Hz to 20 kHz
Input Impedance ................................... >24 k Ohms
Output Impedance ................................ <1 Ohm
Maximum Audio Level ........................ +10 dBu
THD+N ................................................. 0.005%; 20 Hz - 20 kHz
SNR (A-Weighted) ............................... 95 dB
Channel Phase Differential ................... +/-0.1
o
Crosstalk ............................................... Min. 95 dB (1 kHz)
Signal Connectors ................................ 3.5mm Stereo jack
Audio to Video Diff. Delay (skew) ..... <300 uS
3
Power: ON: (GREEN) Indicates that correct power has been applied.
Video: OFF: Indicates no video detected on the input.
BLINKING GREEN: Indicates either H or V sync detected at
the input but not both.
STEADY GREEN: Indicates both H and V sync detected on
the input.
Audio: OFF: Indicates no audio detected on the transmitter unit.
BLINKING: Indicates audio detected on the transmitter unit.
Indicator LEDs:
The Pure Digital Fiberlink
®
7222, 7224 and 7226
transmitters each have three integral indicator LEDs that are used to
monitor the state of the unit.
The status of the LEDs are as follows:
OPERATING POINTERS AND TROUBLESHOOTING
Optical Fiber:
The 7222, 7224 and 7226 transmitters operate with most
multimode (MM) and single mode (SM) optical fibers. All models within
the 7220 Series use the same 1310 nm wavelength and optics for trans-
mitting over multimode or single mode fiber, but be aware that the type
of fiber you use will affect the system’s loss budget and the maximum
transmission distance that it can support.
Troubleshooting:
Multimode fiber optic cable contains an optical fiber with a light
carrying corethat is only .0025 inches (62.5 microns) in diameter.
Single mode fiber optic cable has an even smaller “core,” only .00032
to .0004 inches (8-10 microns). This is smaller than a human hair!
6
GENERAL INFORMATION
The Pure Digital Fiberlink
®
7222, 7224 and 7226 transmitter units
provide 4, 8 and 12 optical outputs respectively of RGBHV video with
stereo audio. Each output transmits over one single mode or multimode
fiber at 1310 nm wavelength. The units are designed to provide point-
to-multipoint signal distribution and are compatible with all receiver
units within the 7220 Series.
The unitsall digital encoding delivers noise-free transmissions that
retain all of their initial parameters, regardless of fiber optic cable at-
tenuation. System operation may be easily monitored using integral in-
dicator LEDs on each unit that continuously signify the presence of
baseband video and audio signals.
Introduction
Technical Specifications
Model Part Number Configurations:
All units transmit at
1310 nm wavelength
over single mode or
multimode fiber. ST
connectors are
provided.
Video:
Input Impedance ....................... RGB: 75 Ohms; H&V: Hi-Z
Input Level ............................... RGB: 714 mV p-p; H&V: 3 to 5 V p-p
H Sync Frequency Range ......... 31.5 to 60 kHz
V Sync Frequency Range ......... 30 to 85 Hz
Number of Video Channels ...... 1 RGBHV
RGB Format Supported ............ RGB with separate H and V
Unit Type Part Number
Four output transmitter 7222-7S-PP*
Eight output transmitter 7224-7S-PP*
Twelve output transmitter 7226-7S-PP*
*PP Values (line cord): NA = N. America, AU = Australia,
EU = Europe, JP = Japan, UK = United Kingdom
2
Therefore, any minute particles of dirt or dust can easily block the fiber
from accepting or radiating light. To prevent this from happening, al-
ways use the provided dust caps whenever optical connectors are ex-
posed to air. It is also a good idea to gently clean the tip of an optical
connector with a lint-free cloth moistened with alcohol whenever dust
is suspected.
The status of the VIDEO and AUDIO indicator LEDs should provide
the first clue as to the origin of an operational failure. If these are off, it
usually means that the fiber is broken or has too much attenuation. Next,
be certain that the input and output signal connections are correct.
If, after reviewing the above possibilities, the system is still not oper-
ating, please contact the Customer Service Department for further as-
sistance.
MAINTENANCE AND REPAIRS
The Pure Digital Fiberlink
®
7222, 7224 and 7226 transmitters have
been manufactured using the latest semiconductor devices and tech-
niques that electronic technology has to offer. They have been designed
for long, reliable and trouble-free service and are not normally field
repairable. Should difficulty be encountered, Communications Special-
ties maintains a complete service facility to render accurate, timely and
reliable service of all products.
The only maintenance that can be provided by the user is to ascertain
that the optical connectors are free of dust or dirt that could interfere
with light transmission and that electrical connections are secure and
accurate. DANGER! Always turn off the transmitter’s power before
removing the optical fiber from the unit!
All other questions or comments should be directed to our Customer
Service Department. It should be noted that manyproblems” can eas-
ily be solved by a simple phone call.
7
General Information ................................................... 2
Introduction ............................................................ 2
Technical Specifications ......................................... 2
Installation Instructions .............................................. 4
Installation Procedure ............................................. 4
System Connections ............................................... 5
Indicator LEDs ....................................................... 6
Operating Pointers and Troubleshooting ................... 6
Maintenance and Repairs ........................................... 7
Limited Warranty ....................................................... 8
CONTENTS
1
8
LIMITED WARRANTY
Communications Specialties, Inc. (CSI) warrants that for a period of
three years after purchase by the Buyer, the Pure Digital Fiberlink
®
7222, 7224 and 7226 transmitters will be free from defects in material
and workmanship under normal use and service. A Return Material Au-
thorization (RMA) number must be obtained from CSI before any equip-
ment is returned by the Buyer. CSI’s obligation under this warranty
will be limited, at its option, to either the repair or replacement of de-
fective units, including free materials and labor. In no event shall CSI
be responsible for any incidental or consequential damages or loss of
profits or goodwill. CSI shall not be obligated to replace or repair equip-
ment that has been damaged by fire, war, acts of God, or similar causes,
or equipment that has been serviced by unauthorized personnel, altered,
improperly installed or abused.
RMA numbers and repairs can be obtained from:
Communications Specialties, Inc.
55 Cabot Court
Hauppauge, NY 11788 USA
Tel: (631) 273-0404 Fax: (631) 273-1638
www.commspecial.com Email: info@commspecial.com
Or, in the Asia Pacific Region:
Communications Specialties Pte Ltd
100 Beach Road, #22-09 Shaw Tower
Singapore 189702
Tel: +65 6391 8790 Fax: +65 6396 0138
Email: csiasia@commspecial.com
Please have your serial number (located on the top label of the unit)
available with contacting us.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

CSI Pure Digital Fiberlink 7222 User manual

Type
User manual
This manual is also suitable for

CSI Pure Digital Fiberlink 7222 is a transmitter unit that provides 4 optical outputs of RGBHV video with stereo audio. Each output transmits over one single mode or multimode fiber at 1310 nm wavelength. The unit is designed to provide point-to-multipoint signal distribution and is compatible with all receiver units within the 7220 Series. The unit’s all digital encoding delivers noise-free transmissions that retain all of their initial parameters, regardless of fiber optic cable attenuation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI