Marantec Dynamic 720 Owner's manual

Category
Gate Opener
Type
Owner's manual
GBFNLI
FULL SERVICE
OPERATOR SYSTEMS
FOR GARAGE DOORS
OPERATOR SYSTEMS
FOR SECTIONAL DOORS
OPERATOR SYSTEMS
FOR SLIDING GATES
OPERATOR SYSTEMS
FOR HINGED GATES
OPERATOR SYSTEMS
FOR ROLLER SHUTTERS
PARK BARRIER
SYSTEMS
ELECTRONIC
CONTROL UNITS
PRODUCT SERVICE
ACCESSORIES
GBFNLI
Dynamic 720
Operator system for sliding gates for industrial use
Anriebssystem für Garagen
Anriebssystem für Garagen
Installation and operating instructions
FULL-SERVICE
OPERATOR SYSTEMS
FOR GARAGE DOORS
OPERATOR SYSTEMS
FOR SECTIONAL DOORS
OPERATOR SYSTEMS
FOR SLIDING GATES
OPERATOR SYSTEMS
FOR HINGED GATES
OPERATOR SYSTEMS
FOR ROLLER SHUTTERS
PARK BARRIER
SYSTEMS
ELECTRONIC
CONTROL UNITS
PRODUCT SERVICE
ACCESSORIES
GB
English / Page 2
GB
English / Page 3
A. Table of contents
A. Table of contents ......................................................................................3
B. Warranty...................................................................................................4
C. Meaning of symbols .................................................................................4
D. Important safety advice .......................................................................5 - 6
E Supply package ........................................................................................7
F. Installation.........................................................................................8 - 36
01. Preparation......................................................................................................8
02. Overview Dynamic 720 ..............................................................................8 - 9
03. Foundation plan ....................................................................................10 - 11
04. Preparation of the drill points for installation .................................................12
05. Preparation of the operator for installation....................................................13
06. Mounting the operator to the floor........................................................14 - 15
07. Adapting the support profile .................................................................16 - 23
7.1. Preparation.............................................................................................16
7.2. Lengthen the support profile...........................................................17 - 19
7.3. Shorten the support profile.............................................................20 - 23
08. Mount the support profile to the gate ...................................................24 - 28
09. Mount the of magnet reference point....................................................29 - 32
10. Mount the closing edge safety device (optional) ....................................33 - 35
11. Connection of control unit.....................................................................36 - 37
G. Emergency unlocking device............................................................38 - 39
12. Emergency unlocking device of the sliding gate
operator at power failure .......................................................................38 - 39
12.1. Unlock operator and gate.....................................................................38
12.2. Lock operator and gate ........................................................................39
H. Initial operation and maintenance...........................................................40
I. Technical details ..............................................................................41 - 42
J. List of illustrations ...........................................................................43 - 44
K. Legend of illustrations.............................................................................45
L. Manufacturer's declaration..............................................................46 - 47
M. Declaration of conformity................................................................48 - 49
English / Page 4
B. Warranty
C. Meaning of symbols
Caution! Danger of personal injuries!
Important safety advice which must always be observed
so as to avoid personal injuries!
Attention! Danger of material damage!
Important safety advice which must always be observed
so as to avoid material damages!
Functional check:
After the mounting and programming of most operating
elements, the control unit functions can be tested. In doing so,
problems can be immediately identified and the time spent
looking for errors is saved.
Advice / Tip
The warranty with respect to the functioning and safety is valid
only if:
- the installation is properly carried out according to the instructions.
- only the original Marantec accessories are used.
- no additional objects are attached to the gate or the operator.
- regular gate and operator maintenance is observed.
Advice!
Failure to comply with these installation and operating
instructions renders the warranty null and void.
English / Page 5
D. Important safety advice
GB
Caution!
Please only mount the operator to surfaces that are statically
stable.
Installation and initial operation of this operator may only be carried out by
qualified and specially trained personnel. These persons have been sufficiently
instructed or supervised by electricians and are therefore able to recognize the
special hazards involved when working with electricity. Moreover, they are
required to have the following qualifications:
- Knowledge of the relevant electro-technical regulations
- Training in the use and maintenance of the necessary safety equipment.
Caution!
Before cabling works the operator has to be disconnected
by all means from mains supply and a waiting time of 90 sec.
has to be kept.
Only after this time the operator is without voltage!
Caution!
Before installation of the operator:
Switch off all devices which will not be needed after the
operator is installed.
Ensure that the gate is in good mechanical condition and
opens and closes properly.
Observe local safety regulations!
Always lay mains and control cables separately!
Control voltage 24 V DC.
English / Page 6
D. Important safety advice
Caution!
Disregard of these warnings may result in personal injuries
and material damages.
Advice!
To avoid installation errors and damages to the gate and
operator, follow the mounting instructions of these installation
instructions exactly!
Please keep these installation instructions for further reference;
they contain important information regarding operational checks
and maintenance work.
Caution!
Before operating the control unit, ensure that no persons
or objects are located in the operation range of gate
since the gate moves for some settings.
- All firmly mounted impulse transmitter and control devices (e.g. radio code
button) must be mounted within sight of the gate, but at a safe distance
from the moving parts of the gate.
- All existing emergency command devices have to be tested before initial
operation.
- After initial operation, the gate system operating personnel or their proxies
must be familiarised with the use of the system!
- Following installation, ensure that gate parts do not protrude onto public
footpaths or streets.
English / Page 7
E. Supply package
GB
Fig. E: Supply package
Operator unit with control unit
Drill pattern
Cover
Magnet and magnet support
Installation instructions
Dowel set for foundation
mounting
English / Page 8
F. Mounting
1. Preparation
Please check that the delivered operator package is complete.
(see as well E. Supply package).
2. Overview Dynamic 720
Fig. F.1: Overview Dynamic 720 - part 1
385
511
372
0-80
144
60
Advice:
Dimensions are always given in millimetres (mm)!
Top edge foundation
English / Page 9
F. Mounting
GB
Fig. F.2: Overview Dynamic 720 - part 2
a Frost-free depth
i Foundation
j Gate
5
=
>
Attention!
The distance of the foundation dowels to the edge has to be at
least 250 mm.
English / Page 10
F. Mounting
Attention!
Please check, whether the toothed rack can be screwed
to the gate at a height of 194 mm + (0-80 mm).
In case the toothed rack cannot be mounted in the required
height, you have to attach a suitable device to the gate.
3. Foundation plan
Advice / Tip
The operator can be mounted on the right or left side of the
gate, depending on opening direction. The pictures show the
supply package for left-hand mounting.
When you want to mount the gate to the right side, please carry
out mounting mirror image. The phases in the operator have to
be exchanged and the magnet has to be turned (see initial
operation and wiring diagram documentation Control 145 FU-S).
English / Page 11
F. Mounting
GB
Fig. F.3: Foundation plan
min. 250
a Frost-free depth
b Clear driveway
c Opening direction
d Mounting area toothed rack
e Beginning of clear driveway
f Projection of gate in closed
position
A Control cable
B Lead cable
C Empty conduit for control cable -
see point 4
D Empty conduit for lead cable -
see point 5
E Control elements or
safety elements
F Empty conduit for command
devices or safety elements
5
6
7
:
8
9
English / Page 12
F. Mounting
C Empty conduit for control
cable
D Empty conduit for lead cable
d Mounting area toothed rack
e Beginning of clear driveway
g Centre spur gear
h Drill holes (4x)
Fig. F.4: Drill pattern top view
4. Preparation of the drill points for mounting
50
min 10
50

8
9
;
<
Attention!
Observe the minimum
drill depth
(Fig. F.8)
Hold the drill pattern against the
gate (compare Fig. F.4 + F.5).
Thrill the holes for the dowels 18)
through the drill pattern.
Fig. F.5: Align drill pattern
English / Page 13
F. Mounting
GB
5. Preparation of the operator for mounting
Fig. F.6: Unlock cover
Fig. F.7: Remove cover
Unlock the cover with the key
(90˚ anticlockwise).
Remove the cover.
English / Page 14
F. Mounting
6. Floor mounting of the operator
Fig. F.10: Put operator onto threaded rods
Fig. F.9: Cables through bottom plate
Fig. F.8: Dimensions heavy-duty dowel
min 60
min 80
ø 18
0-80
"
!
!
!
G Bottom plate
H Spacer ring
I Adjusting nut
J Coupling nut
Insert the heavy-duty dowel into
the drilled holes.
Tighten the dowels with nut (J)
until they are under tension.
Insert the control cable and the lead
cable through the bottom plate of
the operator.
Put the operator onto the
threaded rods.
GB
English / Page 15
F. Mounting
Align the operator as follows:
- The operator is parallel to the gate.
- The outer edge of the spur gear
is in a distance of approx. 7 mm
to the screwing area of the
toothed rack (d).
- The operator is aligned horizontally
(can be adjusted in height).
Tighten the adjusting nuts (I) on the
threaded rods.
Fig. F.11: Distance gearwheel - gate
!
8
ca. 7 mm
English / Page 16
F. Mounting
7. Adapting the support profile
7.1 Preparation
Attention!
The drive pinion must grab into toothed rack in every
gate position.
Check whether the drive pinion grabs into the toothed rack in every
gate position:
- In case the support profile is shorter than the gate:
-> Go on mounting as described in point 7.2
'Lengthen the support profile'.
- In case the support profile is longer than the gate:
-> Go on mounting as described in point 7.3
'Shorten the support profile'.
- If the support profile corresponds to the length of the required gate
movement:
-> Go on mounting as described in point 8
'Mount the support profile to the gate'.
English / Page 17
F. Mounting
GB
7.2 Lengthen the support profile
Fig. F.12: Loosen the screws in the support profile
Fig. F.13: Toothed rack segment out of support profile
Fig. F.14: Lengthen the toothed rack segment
#
&
%
$
'
$
'
'
Loosen the screws (K) on one end
of the support profile (L).
Pull the clamping device (M),
the end position damper (N)
and the toothed rack segments (O)
out of the support profile.
Lengthen the toothed rack by as
much toothed rack segments (O)
as necessary to get the required
length.
English / Page 18
F. Mounting
Pull the assembled toothed rack
segments (O) completely into the
support profile (L).
Fig. F.15: Toothed rack segment in support profile
Fig. F.16: Screwing on of the support profile
'
$
#
$
&
%
Mount now the end position damper (N) and the clamping
device (M).
Screw the clamping device (M) to the support profile (L).
English / Page 19
F. Mounting
GB
Check whether the drive pinion grabs into the toothed rack in every
gate position:
- In case the support profile is now longer than the gate:
-> Go on mounting as described in point 7.3
'Shorten the support profile'.
- In case the support profile corresponds to the length of the required
gate movement:
-> Go on mounting as described in point 8
'Mount the support profile to the gate'.
Attention:
The toothed rack segments must be under slight tension
in the readily mounted toothed rack.
Otherwise it could lead to malfunctions and damages of the
toothed rack.
English / Page 20
F. Mounting
7.3 Shorten the support profile
Fig. F.18: Toothed rack segment out of support profile
Fig. F.17: Loosen the screws in the support profile
#
%
$
&
$
'
Loosen the screws (K) on one end
of the support profile (L).
Pull the clamping device (M),
the end position damper (N)
and the toothed rack segments (O)
out of the support profile (L).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Marantec Dynamic 720 Owner's manual

Category
Gate Opener
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI