IMPORTANT PRE-INSTALLATION CHECKLIST – R3 ALL VERSIONS
Will the cooker be positioned between base units?
Will the cooker be positioned onto an empty wall? If
so please ensure this is marked to enable us to correctly
position the cooker.
Will the cooker be going into an alcove or recessed
area? If so, electrical switches cannot be located above
or behind the cooker. They must be outside of the recess
following the distances advised in our instructions.
Is there space for a 3mm gap to be left each side of
the cooker top plate?
Is there space for a 60mm gap to be left above the lid
handles to allow for opening?
Is the cooker going against a side wall?
If so additional clearances will be needed
The cooker dimensions and clearances can be found
between pages 37-41 (cooker version dependent) of the
installation instructions.
Is the rear wall clear of pipes, wires, drains and other
services?
The rear wall must be clear of any obstructions.
How much gap do you need left behind the cooker
position?
The minimum 14mm gap will be left between the top
plate and finished surface behind. However, if you will be
tiling or fitting anything behind afterwards we will need to
know how much extra space will be required. The
minimum 14mm gap must be left open and uncovered.
More details on this are shown between pages 40-41 of
the instructions.
The cooker hotplate height is 913mm off the finished
floor. Will your surrounding surfaces match this
height?
The cooker dimensions can be found between pages 37-
39 (cooker version dependent) of the installation
instructions.
Electrics
(Twin
Hotplate
option)
Where are you planning on positioning your
electrical connections?
The AGA requires 2 x 13amp switched fused spurs within
2m of the cooker and in the same room. These must not
be above or behind the cooker and must be accessible.
Your electrician may connect these into connection
points near to the cooker. If connection points are
required, these must be within 2.5m either side of the
rear bottom corners. The connection points can be
behind the AGA as long as they are lower than 450mm
from the finished floor.
Full details of this can be found between pages 41-42
(cooker version dependent) of the installation instructions