1. Introduction
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
1-1
Table of contents
1 Introduction........................................................................................................................................ 1-1
1.1 Styles and Symbols .....................................................................................................................................1-2
1.2 Safety Instruction.........................................................................................................................................1-3
1.2.1 Standards ............................................................................................................................................1-3
1.2.2 General safety instructions.................................................................................................................1-3
1.2.3 Installation ..........................................................................................................................................1-3
1.2.4 Placement ...........................................................................................................................................1-4
1.2.5 Operation ............................................................................................................................................1-4
1.2.6 Servicing..............................................................................................................................................1-5
1.2.7 Unpacking of Devices .........................................................................................................................1-5
1.2.8 Modification of Devices ......................................................................................................................1-5
1.2.9 Cleaning instructions screens and mirrors.........................................................................................1-6
2 Pre-Installation requirements ........................................................................................................... 2-1
2.1 Power and grounding..................................................................................................................................2-1
2.2 Environmental conditions ...........................................................................................................................2-1
2.2.1 General conditions..............................................................................................................................2-1
2.3 Floor requirements......................................................................................................................................2-2
2.4 Luminance ...................................................................................................................................................2-2
2.5 Access...........................................................................................................................................................2-2
2.6 Installation and room requirements...........................................................................................................2-2
2.7 Footprint.......................................................................................................................................................2-2
2.8 Overall dimensions......................................................................................................................................2-3
2.9 Maintenance Area .......................................................................................................................................2-4
2.10 Built-in configuration ................................................................................................................................2-4
3 Mechanical setup ............................................................................................................................... 3-1
3.1 Tools needed for installation ......................................................................................................................3-1
4 Scope of delivery ............................................................................................................................... 4-1
4.1 Engine unit...................................................................................................................................................4-1
4.2 Mirror unit....................................................................................................................................................4-1
4.3 Support unit .................................................................................................................................................4-1
4.4 Miscellaneous parts.....................................................................................................................................4-1
1. Introduction
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
1-2
5 Installation ......................................................................................................................................... 5-1
5.1 Support unit .................................................................................................................................................5-1
5.1.1 Extended configuration ......................................................................................................................5-3
5.2 Engine unit...................................................................................................................................................5-5
5.2.1 Grounding cable..................................................................................................................................5-8
5.3 Mirror unit....................................................................................................................................................5-9
6 Final adjustment ................................................................................................................................ 6-1
6.1 The projection lens for SXGA+ systems ......................................................................................................6-1
6.2 The projection lens for XGA systems ..........................................................................................................6-2
6.2.1 Strictly prohibited devices..................................................................................................................6-3
6.2.2 Adjustment devices............................................................................................................................6-4
6.3 First steps.....................................................................................................................................................6-5
6.4 Focus adjustment ........................................................................................................................................6-6
6.4.1 Picture size..........................................................................................................................................6-6
6.4.2 Vertical Trapezoid ...............................................................................................................................6-7
6.4.3 Horizontal trapezoid ...........................................................................................................................6-9
6.4.4 Rotation............................................................................................................................................ 6-10
6.4.5 Horizontal picture shift .................................................................................................................... 6-11
6.4.6 Vertical picture shift......................................................................................................................... 6-12
6.4.7 Locking the Projection Unit ............................................................................................................. 6-12
7 Finish .................................................................................................................................................. 7-1
7.1 Screen borders.............................................................................................................................................7-1
7.2 Shielding ......................................................................................................................................................7-3
7.3 Design trim ..................................................................................................................................................7-3
7.4 Security check..............................................................................................................................................7-4
8 Taking into operation ........................................................................................................................ 8-1
8.1 The IR Remote-Control Unit ........................................................................................................................8-1
8.1.1 Terminology of RCU controls ..............................................................................................................8-2
8.2 General.........................................................................................................................................................8-3
8.3 Menu Layout................................................................................................................................................8-3
8.3.1 Navigating...........................................................................................................................................8-3
8.4 Activating the Menu Bar .............................................................................................................................8-3
8.4.1 Reset Runtime ....................................................................................................................................8-3
8.4.2 Lamp Optimization .............................................................................................................................8-4
8.5 Access to the service menu ........................................................................................................................8-6
8.5.1 Projector Address................................................................................................................................8-7
8.5.2 RS232 baudrate ..................................................................................................................................8-9
1. Introduction
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
1-3
8.5.3 Internal patterns .............................................................................................................................. 8-10
8.5.4 Color/Brightness.............................................................................................................................. 8-12
8.5.5 Orientation ....................................................................................................................................... 8-26
8.5.6 Maintenance .................................................................................................................................... 8-27
8.5.7 No Source Counter ........................................................................................................................... 8-32
8.5.8 I2C Diagnostics................................................................................................................................. 8-33
8.5.9 Dimmer Sensor Power..................................................................................................................... 8-34
8.5.10 Save................................................................................................................................................ 8-35
8.5.11 Freeze............................................................................................................................................. 8-36
8.5.12 Disable IR ....................................................................................................................................... 8-37
8.5.13 Lamps............................................................................................................................................. 8-38
8.5.14 Version ........................................................................................................................................... 8-42
8.5.15 More............................................................................................................................................... 8-43
9 Manual User Interface........................................................................................................................ 9-1
9.1.1 Power Switch ......................................................................................................................................9-1
9.1.2 Standby Switch ...................................................................................................................................9-2
9.1.3 Active Lamp Selection Switch ............................................................................................................9-3
9.1.4 Indication of Power LED......................................................................................................................9-4
9.1.5 Indication of Lamp Door LED ..............................................................................................................9-4
9.1.6 Indication of the Status LEDs..............................................................................................................9-5
10 Inserting the Lamp Modules (120W/100W)................................................................................. 10-1
11 Addresses ....................................................................................................................................... 11-1
11.1 Hotline .................................................................................................................................................... 11-2
1. Introduction
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
1-1
1 Introduction
This chapter explains the used typographic styles and symbols. Safety information is provided concerning the
operation of control room solutions from Barco.
1. Introduction
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
1-2
1.1 Styles and Symbols
The typographic styles and the symbols used in this document have the following meaning:
Bold Labels, menus and buttons are printed in Bold font.
Condensed
Links to both other chapters of this manual and to sites in the Internet are printed
condensed. In the on-line version of this manual all hyperlinks appear teal.
Courier Names of files and parts from programs are printed in the Courier font.
Courier bold Inputs you are supposed to do from the keyboard are printed in Courier bold font.
If you do not heed instructions indicated by this symbol there is a risk of damage to the
equipment!
If you do not heed instructions indicated by this symbol there is a risk of electrical shock
and danger to personal health!
If you do not heed instructions indicated by this symbol there is a risk of damage to parts,
which are sensitive towared electrostatic charge!
If you do not heed instructions indicated by this symbol there is a risk to get harmed by
sharp objects!
If you do not heed instructions indicated by this symbol there is a risk that parts may
explode!
If you do not heed instructions indicated by this symbol there is a risk that hot parts impact
persons or objects!
The sheet icon indicates additional notes.
Next to this icon you find further information.
This arrow marks tips.
Next to this icon you find important notes.
1. Introduction
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
1-3
1.2 Safety Instruction
This section describes safety precautions, which must be observed when installing and operating a product from
BARCO.
1.2.1 Standards
Safety Regulations
The equipment is built in accordance with the requirements of the international safety standard IEC950, UL1950
and CSA C22.2 No. 950, which are the safety standards of information technology equipment including electrical
business equipment.
The safety standards of information technology equipment impose important requirements on the use of safety
critical components, materials and isolation, in order to protect the user or operator against the risk of electric
shock and energy hazard, and having access to live parts.
Safety standards also impose limits to the internal and external temperature rises, radiation levels, mechanical
stability and strength, enclosure construction and protection against risk of fire.
Simulated single fault condition testing ensures the safety of the equipment to the use even when the
equipment’s normal operation fails.
1.2.2 General safety instructions
• All the safety and operating instructions should be read before using this unit.
• The operating instruction manual should be retained for future reference.
• All warnings on the device and in the documentation manuals should be adhered to.
• All instructions for operating and use of this equipment must be followed precisely.
1.2.3 Installation
Installation and preliminary adjustments should be performed by qualified BARCO personnel or authorized BARCO
service dealers.
1.2.3.1 Power Connection
This product should be operated from an AC power source. Power input is auto ranging from 100V to 240V.
Check the power rating on your outlet before connecting the devices to the wall outlet or
to a power strip. Contact your facilities manager or a qualified electrician if you are not
sure what type of power is supplied to your building.
All equipment in the system is equipped with a 3-wire grounding plug, a plug having a third (grounding) pin.
This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the
plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the purpose of the
grounding-type plug.
The devices are designed to operate with single-phase power systems having a grounded
neutral conductor. To reduce the risk of electrical shock, do not plug into any other type of
power system.
Use only the power cord supplied with your device. While appearing to be similar, other power cords have not
been safety tested at the factory and may not be used to power the projector. For a replacement power cord,
contact your dealer.
1. Introduction
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
1-4
If an extension cord is used with this product, make sure that the total of the ampere ratings on the products
plugged into the extension cord does not exceed the extension cord ampere rating.
Also make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes.
A. Mains lead (AC Power cord) with CEE 7 plug:
The colors of the mains lead are colored in accordance with the following code:
Green-and-yellow: Earth (safety earth)
Blue: Neutral
Brown: Line (live)
B. Power cord with ANSI 73.11 plug:
The wires of the power cord are colored in accordance with the following code:
Green/yellow: Ground
White: Neutral
Black: Line (live)
1.2.4 Placement
Place the device in a well-ventilated area away from sources of ignition and out of direct sun light. Never expose
this product to rain or excessive moisture
Slots and openings in the cabinet or bottom are provided for ventilation; to ensure reliable operation of the
product and to protect it from overheating, these openings must not be blocked or covered.
Exposing flammable or combustible materials into close proximity of this device could result in the spontaneous
ignition of that material, resulting in a fire. For this reason, it is absolutely necessary to leave an "exclusion zone"
around all external surfaces of the device whereby no flammable or combustible materials are present. The
exclusion zone must be not less than 10 cm (4").
• Do not allow anything to rest on the power cord. Do not locate this product where persons will walk on the
cord.
1.2.5 Operation
Barco products are designed and manufactured to meet the most stringent safety regulations.
During operation, the equipment
radiates heat on its external surfaces and from ventilation ducts, which is
both normal and safe.
• Do not cover the equipment with any material while the equipment is in operation.
• Do not block the cooling fans or free air movement under and around the device.
•
Keep flammable and combustible materials away from the device at all time.
In the event of fire, use sand, CO2, or dry powder fire extinguishers; never use water on an
electrical fire.
1. Introduction
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
1-5
Do not allow anything to rest on the power cord. Do not locate this product where people will walk on the cord.
To disconnect the cord, pull it out by the plug. Never pull the cord itself.
• Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage
points or short cut parts that could result in a risk of fire or electrical shock.
• Never spill liquid of any kind on the product. Should any liquid or solid object fall into the cabinet, unplug the
set and have it checked by qualified service personnel before resuming operations.
Adjust only those controls that are covered by the operating instructions since improper adjustment of the other
controls may result in damage and will often require extensive work by a qualified technician to restore the
product to normal operation
Lightning - For extra protection for this video product during a lightning storm or when it is left unattended and
unused for a long period of time, unplug it from the wall outlet. This will prevent damage to the unit due to
lightning and AC power-line surges.
1.2.6 Servicing
Never open the case of a device without first disconnecting the power supply cord!
Measurements and tests with an opened device may be carried out only in the factory or
by specially trained personnel, due to the dangers of electrical shock.
Do not attempt to service this device yourself, as opening or removing covers may expose you to dangerous
voltage potential and risk of electric shock! Refer all service to a qualified BARCO service center.
Always have service performed on this product by authorized BARCO service personnel. Always insist on genuine
BARCO replacement parts. Never use non-BARCO replacement parts as they may degrade the safety of this
device.
Call for service in the following conditions:
• When the power cord or plug is damaged or frayed.
• If liquid has been spilled into the device.
• If the product has been exposed to rain or water.
• If the product does not operate normally when the operating instructions are followed.
• If the product has been dropped or the cabinet has been damaged;
• If the product exhibits a distinct change in performance, indicating a need for service.
When replacement parts are required, be sure the service technician has used original BARCO replacement parts
or authorized replacement parts, which have the same characteristics as the BARCO original part. Unauthorized
substitutions may result in degraded performance and reliability, fire, electric shock or other hazards.
Unauthorized substitutions may void warranty.
Upon completion of any service or repairs to this unit, ask the service technician to perform safety checks to
determine that the unit is in proper operating condition.
1.2.7 Unpacking of Devices
Note advises on the packaging for unpacking!
1.2.8 Modification of Devices
Mechanical or electrical modifications must not be made to the devices. BARCO is not liable for damages
resulting from modified devices.
1. Introduction
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
1-6
1.2.9 Cleaning instructions screens and mirrors
Wash with a solution of mild soap or detergent and lukewarm water. Use a clean lint-free soft cloth applying
only light pressure. Rinse with clean water and dry by blotting with a damp lint-free cloth or chamois.
Always use a clean,new, lint-free cloth for cleaning the screens’s front side. Do not clean
with the same cloth used for the beaded side. The used cloth ma contain bead particles,
which could scratch the screen’s front surface
Do not use the following cleaning cleaning agents, since these can scratch or detoriate
the screen surface:
Window cleaning sprays, kitchen scouring compounds, sovlents such as acetone,
gasoline, benzene, alcohol, carbon tetrachloride or lacquer thinner.
Pre-Installation requirements
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
2-1
2 Pre-Installation requirements
2.1 Power and grounding
Attention has to be paid to the electrical installation. Earth current loops in the installation must be avoided. The
neutral power conductor of the electrical net and the grounding conductor must be separated.
All circuits have to use the same ground level (also indirectly connected equipment). If possible all circuits should
come from the same phase.
Each projector has specific power requirements. (see technical specification projectors) Enough circuits have to be
available. These circuits have to be fused (16A typical for 220V). The number of projectors starting up
concurrently must be limited. One could for instance install an automatic circuit that starts up all the projectors in
batches per circuit, leaving 3 second between the different batches. (Not standard delivered)
The projectors should be kept away from strong sources of magnetic fields.
Fused circuits for the graphic generator equipment have to be installed. The number depends on the amount of
installed equipment.
Some of the graphic generator equipment functions as a Unix workstation. It must not be powered off without
carefully closing all the applications. If these units are switched off during normal operation without this
precaution, there is a risk that the file system gets corrupted and it becomes unusable. Therefor it is strongly
suggested to provide a non-interruptible Power Supply (UPS) to power these units.
Additional grounding points must be foreseen for the display wall construction, racks and other mechanics.
Power outlets for installation purposes are required as well. All connections, power, network should be available
and functional before start of the installation.
2.2 Environmental conditions
2.2.1 General conditions
The temperature and the humidity in the control room have to be controlled on the both sides of the wall.
The screens require a temperature between 10 and 40 dgc and humidity between 40 – 80 % RH. The maximum
temperature fluctuations have to be limited up to 5dgc per hr.
The projector units operate between 0 and 40 dgc. The thermal dissipation of the projector units has to be taken
in consideration. The projector units have built-in temperature detection and will switch off automatically when
the temperature limits are exceeded.
The graphical generator equipment operates between 0• and 40 dgc. In case these products are mounted in a
rack the max room ambient temperature has to be limited to max 25 dgc or additional forced cooling has to be
foreseen in the rack.
The materials and products can be stored between -30 and 65 dgc and humidity below 95 % RH, non-
condensing. Screens have to be stored below 40dgc.
24hrs prior to installation the screens have to acclimatize to the control room conditions. They can stay in their
protective packaging during this acclimatize period.
The temperature and humidity conditions in the control room must be within specification during installation and
maintained afterwards.
The room has to be dust-free during the installation and maintained afterwards. The control room must have an
acceptable dust class of 100000 or better. (100000 particles of 0.5µm or larger per cubic feet, comparable with
clean desk room).
All construction, reconstruction, decoration activities must be completed before the installation of the system.
However the trim around an integrated wall can only be mounted after completion of the wall. All precaution
should be taken to avoid any damage during the mounting of the final trim. The purchaser bears the
responsibility for any damage or degeneration during this operation.
The air pressure within the control room has to be the same on the both sides of the wall.
Pre-Installation requirements
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
2-2
2.3 Floor requirements
Sufficient floor space and maintenance area must be available when installing a display wall. (see applicable
drawing and Access)
The floor must have sufficient load carrying capability to withstand weight distribution for all feet (see technical
specifications mechanical construction). It must not sag by more than 1 mm under the load of the display wall.
No installation (venting ducts, sockets etc.) must be present in the floor in the area of the feet. (Advice: An area
of at least 150mm must be kept free around each foot.)
The total construction has to be fixed to the floor. Typical, M10 plugs will be mounted in holes in the floor. If
raised floor (false floor) is used, it’s advised to put the construction on the concrete floor underneath.
2.4 Luminance
Light falling directly on the screen will negatively influence the resulting contrast level. The design of the
lighting should avoid as much as possible light falling directly on to the screen. The real performance of the
projectors will be determined by the light condition on the screen. A good contrast ratio is guaranteed with light
input directly on the screen not more than 50 lux.
There are no constraints on the luminance on e.g. the operator positions.
Light behind the wall is required for installation and service. During normal operations all lights behind the wall
must be switched off. All daylight must be avoided as well.
Bright colors for the ceiling, the walls and floor surrounding the screen have to be avoided. Do not use reflecting
materials for the ceiling, the walls and floor surrounding the screen.
Sufficient lighting in the projection-room is required during installation.
2.5 Access
The buildings have to be accessible during extended straight time, 6AM – 12PM, 7 days per week.
From the delivery point to the installation site, the doors and passages require a minimum width of 1500mm
and height of 2000mm for an installation.
In case the projection-room is located on the ground floor the room need to be accessible with any trolley.
In case the projection-room is located on a floor level an elevator is required.
The elevator needs a minimum entrance and cabin size of 1500 x 1800 x 1200mm (width x height x depth). The
support power must be 1000 kg minimum. The elevator must be available during the installation period.
2.6 Installation and room requirements.
In case the display wall is integrated in a wall, the gap between screen and wall must be constructed as detailed
in the mechanical drawings (front, top, and side view). Typical 100mm before mounting of the trim.
The installation room must be sufficiently high. Sufficient space (recommended > 200mm) must be provided
above the display wall.
A system responsible must be available during the installation for practical arrangements and safety reasons.
Free telephone access needs to be available for local communication.
2.7 Footprint
This footprint can be used to help you set out the wall configuration the room where the wall will be installed.
Pre-Installation requirements
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
2-3
2.8 Overall dimensions
The installation room must be sufficient high. Sufficient space (recommended = 350mm from top of the screen to
finished ceiling) must be provided above the OverView fD70 units. The depth of the OverView fD70 is 780 mm.
The standard support with adjustable feet results in the lower screen edge to be at a distance of 1287.5mm.
Other heights are available on request with a minimum of 613mm.
Pre-Installation requirements
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May-2006
_______________________________________________________________
2-4
2.9 Maintenance Area
OverView fD70 is designed for front access. All maintenance and service work is done from the front. No service
area is needed behind the wall.
Since the position of the ventilation grill is on the sloped cover of the mirror module, no space for air ventilation
has to be provided between the rear of the projection system and the wall: OverView fD70 can be placed directly
against the wall.
The OverView fD70 units can have linear or curved arrangements. With a curved design, the modular aluminum
structure is built with angled connection plates. The angle between two columns can be 0°, 3°, 5°, and 8°.
2.10 Built-in configuration
When the OverView fD70 is integrated in a wall, mind the following recommendations: Leave a gap of 100mm
around the screen. Make sure to take the distance from the lower screen edge to the floor into account (standard
1287.5mm)
Mechanical setup
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May
MayMay
May-
--
-2006
2006 2006
2006
________________________________
________________________________________________________________
____________________________________________________
________________________________________
____________________
3-1
3 Mechanical setup
3.1 Tools needed for installation
• 1 set of screwdrivers
• 1 tape measure (10m)
• 1 tape measure (2m)
• 1 water level
• 1 pencil
• 1 stanley knife
• 1 hexagon key 6mm
• 1 hexagon key 5mm
• 1 torx screwdriver TX30
• 1 torx screwdriver TX20
• 1 adjustment tool set R851162 for lens
adjustment
(included in the delivery of the project,
see picture on the right.)
Scope of delivery
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May
MayMay
May-
--
-2006
2006 2006
2006
________________________________
________________________________________________________________
____________________________________________________
________________________________________
____________________
4-1
4 Scope of delivery
OverView fD70 consists of 3 units, the mirror unit, the engine unit and the support unit. Each of these parts is
pre-assembled and packed individually. An additional box comprises all the small components like the screen
borders, the design trim, etc.
Due to the pre-assembled units and the big weight of the pre-assemblies, it is
recommended to set up the system by a team of four.
All units are packed into a quadruple wall cardbox for highest stability and reliability.
4.1 Engine unit
The engine unit comes in a package of 1000mmx1600mmx810mm with a weight of 71kg.
This cardbox has a red-colored (50g) shock watch label attached to.
Before unpacking the engine unit, make sure that the shock watch indicator does not
show red! In case of a red shock watch indicator do not unpack! Please immediately
contact the shipment company and Barco project management.
4.2 Mirror unit
The mirror unit comes in a package of 1000mmx1600mmx1410mm with a weight of 81kg.
This cardbox has two snap closures. When opened, the carton can be unfolded to free the mirror unit.
4.3 Support unit
The support unit (for lower screen edge at 1288mm) comes in a palette container cardbox of
840mmx1470mmx860mm with a weight of 45kg.
The cardboxes probably don't fit through the doors.
Unpack the units to bring them to their final destination.
Handle with care! Don't bump them on the floor!
The following chapters will include the unpacking instruction as a step of the installation procedure.
4.4 Miscellaneous parts
The screen borders, the design trim, the adjustable feet etc. are packed separately.
Installation
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May
MayMay
May-
--
-2006
2006 2006
2006
________________________________
________________________________________________________________
____________________________________________________
________________________________________
____________________
5-1
5 Installation
5.1 Support unit
• Open the cardbox and lift out the support unit.
• Remove the plastic cover!
The support unit is completely assembled except for the adjustable feet and the safety brackets. The safety
brackets have to be mounted on the adjustable feet, and the feet screwed into the vertical profile.
The vertical profiles are already equipped with a counter nut to screw in the adjustable feet. Two of the
adjustable feet will have to be equipped with a safety bracket for fixation on the floor.
Attach the safety bracket to two of the adjustable feet:
• Unscrew the nut.
• Insert the bracket.
• Re-attach the nut
• Tilt the support unit to get access to these counter nuts.
• Screw in the feet.
• Make sure that the feet with the safety brackets are arranged diagonally.
Installation
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May
MayMay
May-
--
-2006
2006 2006
2006
________________________________
________________________________________________________________
____________________________________________________
________________________________________
____________________
5-2
You might want to turn the safety brackets to show inside the unit and not to be seen on
the floor.
After the installation is complete, don't forget to fix the safety bracket on the floor!
After mounting of the feet, place the support unit on it's final position and adjust the feet to level the unit. The
standard height of a support is realized by setting the feet length to 40mm (measured from floor to vertical
profile).
For further installation work, you have to remove the front shielding of the support unit.
• Pull off the adhesive tape.
• Remove the front shielding and put it aside.
If it is an extended configuration, proceed the same way with all other supports.
Subsequently connect the adjacent supports, cf. Extended configuration
In case of a standalone unit, proceed with the engine unit. The engine unit will be placed on top of the support
unit. Connection is made via 4 profile connectors already mounted to the support unit, one at each vertical
profile, cf. Engine unit
Installation
Barco - OverView fD70 series – DOC-3382-5 – installation manual – revision 04 – May
MayMay
May-
--
-2006
2006 2006
2006
________________________________
________________________________________________________________
____________________________________________________
________________________________________
____________________
5-3
5.1.1 Extended configuration
OverView fD70 systems can be lined up to achieve large display walls with a panoramic view.
In case of an nx1 configuration, it is recommended to go on with the adjacent support
unit! Proceed with the second (third, fourth) support unit as with the first one.
For linear and curved configurations, connection brackets are available to connect the individual systems at the
required angle. There are four connection points, two at the mirror unit, one at the engine unit, and one at the
support unit. The connection points are at the front and rear vertical profiles.
A set of connection brackets always consists of a block (to be applied between the adjacent profiles at the front)
and a sheet metal angle (to be applied between the adjacent profiles at the rear side).
By means of the adjustable feet, first bring the OverView fD70 systems to the identical
level!
Use the water level and align the support units to an identical height by means of the adjustable feet.
Connect adjacent support units:
• at the front side, install the connection block
• at the rear side, install the sheet metal angle.
• Screw the supporting frames together using the polygonal kit. Don’t tighten the securing screws.
The pictures show the principle of connecting the frames (they don't show OverView fD70!)
Figure 5-1
polygonal installation front view
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96

Barco OverView fDR+70-DL Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI