Stellar 17 Remote Control User manual

Category
Fireplaces
Type
User manual
Page 1
17 - REMOTE CONTROL OPERATION INSTRUCTIONS
B. REMOTE CONTROL INFORMATION
Figure 17A
Thermostat Mode
Battery Life
Set Temperature
(visible only in
Thermostat Mode)
Light Level
Child Proof
Manual On/Off
Room
Temperature
Fan Speed
Continuous
Pilot
Flame Height
Pilot
Left To Right:
Flame, Light, Fan and Set
Up
Mode
Down
A. REMOTE ICON IDENTIFICATION
IMPORTANT ELECTRICAL WARNING AND INFORMATION
Electrical wiring must be installed by a licensed electrician.
• Do NOT wire 110V to wall switch.
• Uninterrupted or continuous power is required at all times in IPI systems EXCEPT when using battery back-up.
• Incorrect wiring will override IPI safety lockout and may cause an explosion.
• Disconnect 110V before servicing
A double receptacle box cover and (3) wire nuts are supplied in replace components packet to be used when hardwiring to electrical box
located under rebox on right side of replace.
IMPORTANT ELECTRICAL WARNING AND INFORMATION
THIS SYSTEM GOES THROUGH A CALIBRATION MODE WHEN SWITCHING FROM ‘ON’ TO ‘THERMO’ TO ‘OFF’ MODES, CREATING A
HUMMING SOUND WHICH IS A NORMAL PART OF OPERATION.
Page 2
C. CONTINOUS PILOT - FOR VERY COLD CONDITIONS
The IPI gas control system has the option of a continuous (standing) pilot feature. This allows you to change from a spark-to-pilot system to a stand-
ingpilotsystemduringcoldweatherconditions.Byhavingthepilotoncontinuously,thereboxwillremainwarmandadraftisestablishedinthevent,
allowingthemainburnertoturnonwithlessair-owdisruption.
Whencontinuouspilotmodeisactivated,thepilotwillsparkandlight.WhenreplaceisturnedOFF,thepilotwillremainlitwhenmainburnerhasbeen
turnedOFF.
Thispilotfeaturecanbeactivatedorde-activatedbythehandheldremotecontroltransmitterortheswitchonthemodule.Instructionsonfollowing
page.
D. OPERATION USING BATTERY POWER
E. MATCHING SECURITY CODES
Beforematchingsecuritycodesmakesure120VACisconnectedandpoweredtoreplace,andhandheldremotecontrolisinstalledwith(2)
batteries.ItmaybenecessarytoprogrammaincontrolmoduletoLEARNthesecuritycodeofthehandheldremotecontroluponinitialuse,if
batteriesarereplaced,orifareplacementremotecontrolispurchasedfromyourdealer.
1. Whenmatchingsecuritycodes,besureslidebuttononmain
controlmoduleisinREMOTE;thecodewillnot“LEARN”ifslide
isinOFF.
2. ProgrammaincontrolmoduletoLEARNanewsecuritycodeby
pushinginLEARNbuttononmaincontrolmoduleusingapencil
pointfor2secondsandletgo(youshouldhearaseriesof‘beeps’
letting you know module is ready to learn a new code).
3. ImmediatelypressMODEbuttononhandheldremotecontrol
(youshouldhearfour‘beeps’inrapidsuccessioninmaincontrol
module, indicating remote
control’scodehasbeenprogrammedintothemaincontrol
module).Whenanexistingmaincontrolmoduleisintroduced
to a new hand held remote control, the new security code will
overwrite the old one.
Ifiteverbecomesnecessarytoclearthememoryfromthehandheld
remotecontrol,simplypushandholdtheLEARNbuttonfor10seconds
(youshouldhearthreelongbeepsinsuccession).Youmaynowfollow
stepsoutlinedaboveto‘RE-LEARN’securitycodes.
Figure 17E
Slide To REMOTE
17 - REMOTE CONTROL OPERATION
IMPORTANT NOTE
When operating replace in this capacity, the only function available is ame modulation.
1. Thisreplacehasanoptionalbatteryoperationifelectricalpowerislost(seePage45,Figure16B).Positionbatterypackwithfour“AA”size
batteriesinstalledbetweenvalveandfrontofreplace.Thisisthecoolestlocationunderrebox,ensuringlongerbatterylife.
2. Nextlocatethereplace'scontrolmodule(seePage45,Figure16A).The"Remote/Off"slideswitchonthebacksideofthemodulemustbeslid
intothe"Off"positiontoallowthebatterypacktofunction.
3. Onceaccomplished,thereplacecanbeturnedfullyonoroffusingtheOn/OffRockerSwitchlocatedonthefrontbracketofthevalveassembly
below.
NOTE: When in Battery Mode, the only functions available are turning the replace on or off.
No ame adjustments are available nor will the remote control be available for the fan, ember lights, thermostat, etc.
LEARN BUTTON
PILOT IGNITOR
CONNECTION
PILOT SENSOR
CONNECTION
REMOTE
ON/OFF SWITCH
CONTINUOUS
PILOT SWITCH
120 VAC
ADAPTER
CONNECTION
WIRE HARNESS CONNECTION
TO EXTENSION MODULE
WIRE HARNESS CONNECTION
TO VALVE STEPPER MOTOR
Page 3
17 - REMOTE CONTROL OPERATION
F. INTITAL SET-UP
Plug Extension Module and AC Adaptor into receptacles.
Install(4)AAbatteriesintobatterycompartmentofBackup Battery Pack,makingsurebatteriesareinstalledinproperdirection.Positionbetween
valveandfrontofstove.AVelcrostriphasbeenattachedtohelpsecureinplace.
The Hand Held Remoteoperateson(2)AAAbatteries.WerecommendalwaysusingALKALINEbatteriestoextendbatterylifeandimprove
operational performance.
Thissystemallowsforgastypeconversionandtemperatureunitconversionbyfollowingthesetupprocedureoutlinedbelow.
G. GAS TYPE CONVERSION
Press and hold LearnButtononMainControlModulefor20seconds.Abeepwillbeheardlettingyouknowtheprocedurehasbeencompleted.
• If converting from NAT to LP gas: (1) one second long beep
• If converting from LP to Nat gas: (3) three second long beep
Continuewithgastypeconversionbyfollowinginstructionsincludedwithgasconversionkit.
H. CELSIUS/FAHRENHEIT CONVERSION
PressUPandDOWNkeyssimultaneouslytochooseCelsiusorFahrenheit.
I. IMPORTANT SAFETY FEATURE
J. CONTINUOUS PILOT FEATURE
K. CHILDPROOF FEATURE
Thissystemhasamaximumroomtemperaturelimitof95°F(35°C)inbothmanualandthermostatmodes.Whenroomtemperatureisatorabove
this point the system will shut down and the hand held remote control will read OFF. If you turn the system ON when room temperature is still at or
abovethistemperature,thesystemwillagainshutdownafter2minuteswhenroomtemperatureisrecalculated.
Activationofthisoptionalfeatureisaccomplishedbypressingthe
PILOTbuttononce.ThecontinuouspiloticonwillappearontheLCD
screen. Pressing PILOTbuttonagainwillde-activatethisfeature.
ThisfeaturecanalsobeactivatedviaCONTINUOUS PILOT switch on
MainControlModule.
ActivationofthisoptionalfeatureisaccomplishedbypushingSET &
UPbuttonssimultaneouslyfor5seconds.Thechildproof icon will
appearonthescreen.Whenatransmitterbuttonispressedtheicon
willashonscreen,butnosignalwillbetransmitted.Pressingand
holdingthesesametwobuttonsagainformorethan5secondswill
de-activate this function.
This feature controls only manual functions of the hand held remote,
automaticfunctions(thermostatmode)willnotbeaffected
.
Figure 17J
Figure 17K
IMPORTANT NOTE
This system is sent to you set up for Natural Gas and temperature units readable in Fahrenheit.
Page4
17 - REMOTE RECEIVER INFORMATION
L. MANUAL MODE
M. FAN MODE
N. LIGHTING MODE
Thisremotecanbemanuallyorthermostaticallyoperated.
Press MODEbuttonformanualON.Theameiconwillappearon
the LCD screen. Press MODEbuttonagaintoputthecontrolinto
THERMO mode. Pressing MODEagainwillturnreplaceOFF.
Thisremotewilloperatethefan,allowingfor(6)differentspeedlevels.
When the FANbuttonispressed,FAN levelsettingwillashonthe
LCD screen. Press UP or DOWNbuttonstoselectdesiredfanspeed
level.Ifnoadjustmentismadewithin7seconds,thecontrolwillexit
function setting mode and LCD display will return to normal view.
Thisremotewilloperatethelights,allowingfor(6)differentlightlevels.
When LIGHTbuttonispressed,LIGHTlevelsettingwillashonthe
LCD screen. Press UP or DOWNbuttonstoselectdesiredlightlevel.
Ifnoadjustmentismadewithin7seconds,thecontrolwillexitfunction
setting mode and LCD display will return to normal view.
Figure 17L
Figure 17N
Figure 17M
IMPORTANT NOTE
Fireplace does not have to be burning to operate the lights.
IMPORTANT NOTE
Delayed ON/OFF - The fan will not turn on until replace has been
burning for 5 minutes and will not turn off for 12 minutes after
replace has been turned off.
EXCEPTION: If replace is turned back on during 12 minute off-
delay time frame, the fan will remain on. This applies to MANUAL
and THERMO modes
.
IMPORTANT NOTE
The MODE button operates in a seri
es that will cycle from ON to
THERMO to OFF.
Page5
O. FLAME MODE
Thisremotewilloperatetheame,allowingfor(6)differentame
height levels. When MAIN FLAMEbuttonispressed,FLAME level
settingwillashontheLCDscreen.PressUP or DOWNbuttonsto
selectdesiredamelevel.Ifnoadjustmentismadewithin7seconds,
thecontrolwillexitfunctionsettingmodeandLCD display will return to
normal view.
P. THERMO (THERMOSTATE) MODE
Thisremotefeatureallowsyoutothermostaticallycontrolthereplacewhenhandheld
remote is set to THERMO mode.
SetTemperatureRange:45˚F(7˚C)to90˚F(32˚C).
SetremotetoTHERMOmodebypressingMODEbutton.ThesmallerSET window of
numbersappearsontheLCDscreen.TherstSETnumberwillread45˚F.PressUP
buttontodesiredsetroomtemperature.Within5secondsreplacewilloperatetothatSet
Temperature. The FLAME, ON and THERMO icons will appear on the LCD screen. By
pressing UP or DOWNbuttonsanewsettemperaturemaybeattained.
SET Temperature will only appear when THERMOSTAT MODE is activated, but is
implemented in all MODES with the exception of MANUAL MODE.
ToexitTHERMO mode press the MODE button.ThisalsoshutsreplaceOFF.
Q. SYSTEM OPERATION WITHOUT HANDHELD REMOTE
This system is designed to operate with the hand held remote or a
thermostat,butintheunlikelyeventthatitisrequiredtobeoperated
without the hand held remote or a thermostat, follow this simple
procedure.
SlideREMOTE /OFF switch on main control module to OFF. The
replacecannowbelitandshutoffbyuseoftheON/OFF rocker switch
locatednexttothemodule.
Figure 17O
Figure 17P
LEARN BUTTON
PILOT IGNITOR
CONNECTION
PILOT SENSOR
CONNECTION
REMOTE
ON/OFF SWITCH
CONTINUOUS
PILOT SWITCH
120 VAC
ADAPTER
CONNECTION
WIRE HARNESS CONNECTION
TO EXTENSION MODULE
WIRE HARNESS CONNECTION
TO VALVE STEPPER MOTOR
Switch
Remote
To OFF
Figure 17Q
IMPORTANT NOTE
When in THERMO mode the replace will not turn on until room temperature falls below SET TEMPERATURE.
IMPORTANT NOTE
The replace will initially light at the highest level. After 5
seconds the ame will adjust to last chosen level before replace
was turned OFF.
This applies to MANUAL and THERMO modes
.
IMPORTANT NOTE
The ame height can adjust up to (6) different height levels
according to amount of heat required. This range however is
dictated by the Flame Level setting (see previous page). When
desired temperature is met, the replace will shut off until more
heat is required.
IMPORTANT NOTE
When operating replace in this capacity, the only function
available is burner operation on HI.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Stellar 17 Remote Control User manual

Category
Fireplaces
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI