agape IRUB1112 is a flexible hose with O-ring seal connectors that can be hand-tightened. It has a maximum torque of 3 Nm and should not be tightened with inappropriate tools or in inappropriate ways. The hose should not be set in the wall, and it should not be exposed to lateral stress or overtightened by any tool. It has a minimum bend radius of 25 mm for DN6, 30 mm for DN8, 35 mm for DN10, and 45 mm for DN13. Before bending the hose, consider a straight part of at least 1.5-2 times the external diameter.

agape IRUB1112 is a flexible hose with O-ring seal connectors that can be hand-tightened. It has a maximum torque of 3 Nm and should not be tightened with inappropriate tools or in inappropriate ways. The hose should not be set in the wall, and it should not be exposed to lateral stress or overtightened by any tool. It has a minimum bend radius of 25 mm for DN6, 30 mm for DN8, 35 mm for DN10, and 45 mm for DN13. Before bending the hose, consider a straight part of at least 1.5-2 times the external diameter.

ISTRUZIONI DI MONTAGGIO
ASSEMBLY INSTRUCTIONS
Rubinetti / Taps
1/2
RUBINETTI
FLESSIBILI
ISTRUZIONI DI MONTAGGIO
ASSEMBLY INSTRUCTIONS
Rubinetti /Taps- essibili/hose
COD.
16018 20160610/0 - SV
VERS. 2/2
Prima dell’installazione controllare la pre
-
sibili da ambo i lati.
Before installation, check presence and
integrity of the clamping of the side tu
bes.
Non serrare con utensili non
adatti o in punti non corretti.
Do not tighten by inappropriate
tools or in inappropriate ways.
Dopo il montaggio evitare sol
lecitazioni laterali anche mini
me, con qualsiasi utensile.
-
rante o astina).
Do not expose the hose to
lateral stress nor overtight by
any tool.
(Ex.: during the installation of
the faucet stud or the drain
pop-up lever).
Non incassare il condotto
nel muro.
Do not set the hose in the
wall.
torsione o in tensione.
Tighten the hose without
any twist or tension.
Il contatto prolungato con sostanze, pur
blandamente aggressive, può determina
re il danneggiamento della treccia ed il
Prolonged contact with any substance,
even scarcely aggressive, can cause
external braid damage and subsequent
Avvitare i raccordi con tenuta O.R.
a mano. Coppia massima di ser
raggio 3 Nm.
Hand-tighten O-ring seal connec
tors.
Max torque 3 Nm.
Avvitare i raccordi con tenuta a
guarnizione (dadi) a mano più
1/4 di giro con chiave appro
priata.
Hand-tighten connectors with
gasket seal (nuts) then apply
1/4 turn using an appropriate
wrench.
Rispettare il raggio minimo di cur
vatura.
Maintain minimum bend radius.
DN6 = 25 mm DN8 = 30 mm
DN10 = 35 mm DN13 = 45 mm
Prima dell’inizio della curvatura la
sciare un tratto rettilineo di almeno
1,5 - 2 volte il diametro esterno.
Before bending the hose please
consider a straight part of at least
1,5-2 times the external diameter.
Non collegare la messa a terra dell’impianto elettrico al
Chiudere l’impianto idraulico in caso di prolungata assen
nor to any other water piping.
Turn o the plumbing in case of long absence. Replace the
hose in case of leakage and anyway.
1
2
3
4
5
6
7
8
9
10
11
  • Page 1 1
  • Page 2 2

agape IRUB1112 Assembly Instructions

Category
Sanitary ware
Type
Assembly Instructions
This manual is also suitable for

agape IRUB1112 is a flexible hose with O-ring seal connectors that can be hand-tightened. It has a maximum torque of 3 Nm and should not be tightened with inappropriate tools or in inappropriate ways. The hose should not be set in the wall, and it should not be exposed to lateral stress or overtightened by any tool. It has a minimum bend radius of 25 mm for DN6, 30 mm for DN8, 35 mm for DN10, and 45 mm for DN13. Before bending the hose, consider a straight part of at least 1.5-2 times the external diameter.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages