Keston Mechanical Timer User guide

  • Hello! I've reviewed the user guide for the Keston Mechanical Timer, specifically the COMBI C 24 Hour model. It details how to set the current time, program on/off cycles via tappets, and use the manual override switch. I'm ready to answer your questions about the timer or any other content within the document.
  • How do I set the current time on the timer?
    How do I set the ON and OFF periods?
    How does the manual switch work?
2016
UIN 216276 A03
USER GUIDE
When replacing any part on this appliance, use only spare parts that you can be assured
conrm to the safety and performance specication that we require. Do not use
reconditioned or copy parts that have not been clearly authorised by Keston.
For the very latest copy of literature for specication and maintenance practices visit our
website www.keston.co.uk where you can download the relevant information in PDF format.
MECHANICAL TIMER, 24HR
Mechanical Timer, 24 Hour
The national regulations and respective safety instructions are to be observed.
Interferences and changes to the device will lead to cancellation of the warranty.
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
12
6
GRASSLIN
3
ix7481
A
lign current
time to arrow
Outer dial
24hr cloc
k
SETTING UP
The outer dial should be set to the current
time. Rotate the dial slowly in a clockwise
direction, until the correct hour is aligned with
the arrow printed on the dial.
Note that the outer dial is printed with the 24hr
clock
8.00am = 8 on the dial,
8.00pm = 20 on the dial.
Clock hands will allow for ne adjustment of
the current time setting of the dial.
Do not attempt to rotate the dial in an anti-
clockwise direction.
Suitable for the KESTON COMBI C RANGE
The national regulations and respective safety instructions are to be observed.
Interferences and changes to the device will lead to cancellation of the warranty.
Suitable for the KESTON COMBI C RANGE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
12
6
GRASSLIN
3
ix7480(1)
ON
ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
12
6
GRASSLIN
3
ix7480(1)
ON
ON
PROGRAMMING SWITCHING TIMES
Set tappets to outer edge for ON periods
and set tappets to inner edge for OFF
periods.
The example shown has been set with 2
on periods.
ON at 9.00am. OFF at 1.00pm. (13
hours)
ON at 6.00pm. (18 hours) OFF at
10.00pm (22 hours)
MANUAL SWITCH OPERATION
The manual switch will provide Fixed
On / Timed / Fixed Off control, thereby
allowing manual control of the output
without disrupting the timed (tappet)
settings.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
12
6
GRASSLIN
3
ix7479(1)
FIXED ON
FIXED OFF
-
TIMED
SWITCHES ON & OFF
DEPENDANT ON
POSITION OF TAPPETS
ON PERIOD
OFF PERIOD
3
WEEE DIRECTIVE 2012/19/EC
Waste Electrical and Electronic Equipment Directive
At the end of the product life, dispose of the packaging and product in a
corresponding recycling centre.
Do not dispose of the unit with the usual domestic refuse.
Do not burn the product.
Remove the batteries.
Dispose of the batteries according to the local statutory requirements and not
with the usual domestic refuse.
Keston Heating, PO Box 103, National Avenue, Kingston Upon Hull, HU5 4JN
Tel. 01482 443005 Fax. 01482 467133. email [email protected]. www.keston.co.uk
Keston pursues a policy of continuing improvement in the design and performance of its products.
The right is therefore reserved to vary specication without notice.
/