Cole-Parmer ST-200D-UT Ultra-Thin Magnetic Stirrer is a compact and powerful laboratory device designed for efficient mixing of liquids. With its flat design, it can be easily placed under taller beakers and other glassware, making it ideal for space-constrained environments. The variable speed control allows for precise adjustment of stirring speed, ensuring optimal mixing for various applications. The magnetic stirrer features a durable construction and is easy to clean, making it a reliable and low-maintenance solution for laboratory use.

Cole-Parmer ST-200D-UT Ultra-Thin Magnetic Stirrer is a compact and powerful laboratory device designed for efficient mixing of liquids. With its flat design, it can be easily placed under taller beakers and other glassware, making it ideal for space-constrained environments. The variable speed control allows for precise adjustment of stirring speed, ensuring optimal mixing for various applications. The magnetic stirrer features a durable construction and is easy to clean, making it a reliable and low-maintenance solution for laboratory use.

84003-71
User manual
Ultra-thin Magnetic Stirrer
Thanks for your selection of the Cole-Parmer Ultra-flat Magnetic Stirrer.
Contents
Safety instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Maintenance and Cleaning - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Included accessories ---------------------------------
Plate overview -------------------------------------
Operating instructions -------------------------------
Warranty -----------------------------------------
Troubleshooting ------------------------------------
Technical Data -------------------------------------
Please read this user manual carefully before use and follow all the safety and
operation instructions.Please retain this manual for future reference.
1
R
4
5
2-3
10
11
12
6
7-9
Safety instructions
2
·When operating the magnetic stirrer, please follow all safety instructions, the accident prevention regulations, and
pay close attention to maintain your health and safety.
· Notice: Effects of magnetic field should be taken into account(e.g.data storage, pacemakers, etc)
· Wear appropriate protective equipment when operating, otherwise harm may result from:
- Splashing of medium
- Ejection of stir bar
- Release of toxic or flammable gases
·Use only the AC adapter supplied with unit.
·Place the instrument on a stable, clean, anti-slip, dry and fireproof surface.
·Ensure the base of instrument is clean and intact.
·Check and ensure the instrument and accessories remain intact before each use. Do not use damaged components.
·Reduce the speed if:
- The medium splashes out of container in high speed
- The container shifts on the plate
· Beware of hazards due to:
- Low-boiling flammable medium
- Improper container size
- Container movement from plate center, as container may fall off plate
!!
!!
Safety instructions
3
·The temperature of the instrument may rise under normal use.
· Process pathogenic materials only in airtight container within a suitable fume hood.
·Do not operate the instrument in explosive atmospheres, with hazardous substances or under water.
·Only use medium that will not react dangerously with the energy generated through processing or through other
ways, e.g. Light.
·Safe operation is only guaranteed with the accessories described in the ‘Optional accessories’ section.
·When using PTFE-coated magnetic bars, please note the following problems may occur:
Chemical reactions of PTFE with molten or dissolved alkaline and alkaline-earth metals, as well as with powders of
elements from Groups ll or lll of the periodic system of elements at the temperatures above 300-400°C. While at
ordinary temperatures, only elementary fluorine, trifluoride and alkaline metals will corrode PTFE, and halogenated
hydrocarbons will exert a reversible swelling effect.
· Caution: Do not spill corrosive liquids on the instrument! Do not use the instrument under water!
·The mains voltage must be in accordance with the voltage marked on the nameplate.
·Unplug the instrument from the electric outlet if it will not be used for extended periods of time.
·Do not cover the device, even partially with metallic plates or film as this may result in overheating.
!!
!!
Maintenance and cleaning
4
·Keep the surface of the plate clean and intact.
·Unplug the power line before cleaning.
·Minimize exposure to moisture when cleaning instrument.
·Wear protective gloves when cleaning.
·We only recommend using the cleaning methods listed below, using alternate cleaning methods may cause
damage to the instrument.
Suggested cleaning methods:
Dyes -------------------------------- Isopropyl alcohol
Construction materials -------------- Water containing active agent/isopropyl alcohol
Cosmetics -------------------------- Water containing active agent /isopropyl alcohol
Foodstuffs -------------------------- Water containing active agent
Fuels -------------------------------- Water containing active agent
8400 -713
User mnual
a
ltra -thi Mag neti c Sti rer
Un r
Included accessories
5
AC adapter×1 Stirring bar×1
User manual×1
Container plate
Timer indicator
Stir indicator
Reverse indicator
On/Off
Switch key
Slider bar
(for parameter adjustment)
LCD screen
Operating instructions
7
1.Connect the instrument to an electrical outlet (the mains voltage must be in accordance with the voltage marked on
the nameplate)
2.Turn on instrument by the Power key , the Stir indicator will flash, and the LCD screen will display the
stirring speed set last time
3. Press the Switch key to switch to different function setting until relevant indicator flashes and LCD screen displays
setting parameter desired
Stirring speed setting Reverse stirring setting Timer setting
Stirring speed setting
Press the Switch key until the Stir indicator flashes, then touch and move your finger on the slider bar to adjust
the stirring speed with the step size of 10 rpm and total range of 20 1500RPM. The instrument will start stirring 4
seconds after the setting is complete and the Stir indicator remains on and the LCD screen displays real time
speed.
-
8
Operating instructions
Activate/deactivate reverse stirring mode
Press the Switch key until the Reverse indicator flashes, then touch and move your finger on the slider bar to
activate or deactivate the reverse stirring mode.
Slide your finger toward the + direction until the LCD
screen displays an “on” signal. The instrument will start
stirring 4 seconds later, with the Reverse indicator
on and the LCD screen displaying the real time speed.
In this mode, the stirring bar rotates in opposite direction
every 45 seconds and pauses for 5 seconds before
reversing.
Slide your finger toward the - direction until the
LCD screen displays an “off signal. The instrument
will start stirring 4 seconds later, with the Reverse
indicator off and the LCD screen displaying the
real time speed.
Activate:
Deactivate:
Switch
SWITCH Switch
SWITCH
Caution: At certain speeds, irregularities in the shape of the stirring bar and of the bottom of the container may
cause the stirring bar to bounce irregularly during stirring. If this occurs, increase or decrease the speed
until the stir bar begins to rotate evenly.
9
Operating instructions
Timer setting
Press the Switch key until the Timer indicator flashes, then touch and move your finger on the slider bar to
adjust the timing with the step size of 5 minutes and total range of 0 9 hours. The instrument will start stirring
4 seconds after setting is complete and the Timer indicator will remain on. The LCD screen will display the
remaining countdown time. When the timer reaches zero, the instrument will automatically shut down.
-
Auto-save function
The speed /reverse mode / timing settings will be saved automatically when the instrument is turned off, and will
automatically be restored the next time you turn the instrument on.
Warranty
10
This instrument is warranted for a period of 24 months from the date of invoice. For claims under the warranty please
contact your supplier.
The warranty does not cover wear and tear of parts or accessories, nor does it apply to improper use, abnormal
operation or insufficient maintenance which is not in accordance with the instructions in this user manual.
normal
Irregularities in the shape of the stir bar
and of the bottom of the container
Increase or decrease the speed until the
stir bar begins to rotate evenly
11
Troubleshooting
Before contacting your supplier in case of an issue, please check below for troubleshooting some common issues.
Problem Possible causes
Solutions
Instruments does not
power on
Stir bar bounces
irregularly
Stir bar does not
rotate
Ensure reliable connection between power
line and power adapter
Power line and power adapter
disconnected
Power line unplugged Ensure power line is securely plugged in
Container is too far from plate center
Mismatch of stir bar specifications
and models
The material of the container is Fe or
Cu which will be magnetized
Position container directly on center of plate
Use stir bar recommended for model
Use glass or 304 stainless steel container
Technical Data
Max. stirred quantity(H O)
2
Motor rating output
Stir bar length range
Speed range
Reversible stirring function
Timer
Display
Plate material
Plate Dimensions
Housing material
Dimensions (W x H x D)
Weight
Voltage& Frequency
Permissible ambient temperature
Permissible relative moisture
Storage temperature
IP65
Protection class (DIN EN 60529)
Power adapter output voltage
Maximum load capacity
1L
3W
25 30mm-
20 1500RPM-
0 9hours-
LCD
Polyester
Diameter 100mm
Polypropylene
110 × 180 × 12mm
0.2kg
100 240 V, ~50/60Hz-
12 V 1A
5 40°C(in the operation)-
80%
-10 70°C-
1kg
12
Every 45s when activated
Toll-Free: 1-800-323-4340
Phone: 1-847-549-7600
Fax: 1-847-247-2929
Coleparmer . com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Cole-Parmer ST-200D-UT Ultra-Thin Magnetic Stirrer User manual

Type
User manual

Cole-Parmer ST-200D-UT Ultra-Thin Magnetic Stirrer is a compact and powerful laboratory device designed for efficient mixing of liquids. With its flat design, it can be easily placed under taller beakers and other glassware, making it ideal for space-constrained environments. The variable speed control allows for precise adjustment of stirring speed, ensuring optimal mixing for various applications. The magnetic stirrer features a durable construction and is easy to clean, making it a reliable and low-maintenance solution for laboratory use.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI