American Standard TU106507.278 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

- 1 -
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2018
Thank you for selecting American Standard...
the benchmark of ne quality for over 100 years.
RECOMMENDED TOOLS
M965929 Rev. 1.0 (12/18)
ROUGHING-IN DIMENSIONS
Patience
Pressure Balancing
Bath and Shower Trim Kit
INSTALLATION
INSTRUCTIONS
TU106500
TU106501
TU106502
TU106507
TU106508
Plumbers’ Putty
or Caulking
Adjustable Wrench Channel Locks
Phillips Screwdriver
To assure proper positioning in relation to wall.
Note roughing-in dimensions.
Teon Tape
Flat Blade Screwdriver
FINISHED WALL
4"
TOP OF TUB RIM
BOTTOM OF TUB
74" (1879 mm)
FOR HEAD
CLEARANCE
3-3/4"
(97 mm)
2" TO 3"
(51 TO 76 mm)
18" (457 mm)
OPTIONAL
7"
(177 mm)
7-5/8"
(207 mm)
1/2" NPT
1/2" COPPER
FOR SLIP-ON
SPOUT
7-13/16" DIA.
(198 mm)
1-1/2"
4-1/8"
(105 mm)
7-3/8"
(187 mm)
9-1/2"
(223 mm)
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 78"
(1651 AND 1981 mm)
7"
(160 mm)
2-3/4"
(83 mm)
2-3/4" MAX. (69 mm)
1-3/4" MIN. (45 mm)
5"
(127 mm)
CARTRIDGE INSTALLATION
11
1
2
6
5
3
4
UP
UP
To ensure that your installation proceeds smoothly-please
read these instructions carefully before you begin.
For use with shower heads rated at 4.9 L/min (1.3 gpm) or higher.
Remove PLASTER GUARD (6)
(Keep it installed for thin wall Installation).
Remove BONNET NUT (1) by unthreading it
Counter clockwise. Remove test CAP (2).
Remove PROTECTIVE HOUSING (3) from
CARTRIDGE (4). Install with “UP” text on top.
Reinstall BONNET NUT (1) onto VALVE BODY (5)
and tighten rmly with 12 Nm or 9 lbs/ft.
NOTE: Specied tightening torque
of BONNET NUT (1) is critical to
assure sealing function.
- 2 -
UP
4
2
UP
1
1
2
UP
1
PLASTER
GUARD
Figure 2.
Figure 1.
Figure 1a.
1
Figure 2a.
4
3
C
H
4
3
C
H
2
4
Hold ADAPTER (4) onto CARTRIDGE STEM (2) and install ADAPTER SCREW (5)
through ADAPTER (4) into CARTRIDGE STEM (2). Tighten ADAPTER SCREW
(5) to secure ADAPTER (4) to CARTRIDGE STEM (2).
Install HANDLE (1) by pushing it onto CARTRIDGE STEM (2) and tightening SET
SCREW (3) from below with 2.5 mm Hex Wrench supplied.
HANDLE INSTALLATION
M965929 Rev. 1.0 (12/18)
3
INSTALL TUB SPOUT, SHOWER HEAD,
SHOWER ARM WITH FLANGE
Remove pipe cap and plug from shower and tub
rough piping.
Slip DECORATIVE PLATE (5), then slip TUB SPOUT (1) onto tub
nipple and tighten with 4mm Hex Wrench.
CAUTION: Protect nish on TUB SPOUT when installing.
Install SHOWER ESCUTCHEON (2) onto SHOWERARM (3). Apply
sealant or Teon tape to threads on both ends of SHOWER ARM (3)
and thread longer leg of SHOWER ARM (3) into shower elbow.
Thread SHOWER HEAD (4) onto SHOWER ARM (3).
CAUTION: Protect nish on SHOWER HEAD and ARM when
installing.
CAUTION
Protect nish on SHOWER HEAD
and TUB SPOUT when installing.
PIPE
PLUG
PIPE
CAP
4
3
2
SHR.
ELBOW
TUB FILLER
NIPPLE
1-1/2" REF.
2.5 MM HEX
WRENCH
1
5
OFF
1
5
4
2.5MM HEX
WRENCH
3
2
Figure 1. Remove plaster guard from valve. Push CAP (1)
over VALVE CARTRIDGE (2) until seated against stop.
Figure 2. Push ESCUTCHEON (3) onto CAP (1) and attach
to valve body with LONG SCREWS (4).
THIN WALL INSTALLATION
Figure 1a. Push CAP (1) over VALVE CARTRIDGE (2) until
seated against stop.
Figure 2a. Push ESCUTCHEON (3) onto CAP (1) and attach
to valve body with LONG SCREWS (4).
STANDARD WALL INSTALLATION
- 3 -
M965929 Rev. 1.0 (12/18)
7
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
6
5
By restricting HANDLE rotation and limiting the amount of hot water
allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1)
reduces risk of accidental scalding. To set the maximum hot water
temperature of your faucet valve, adjust the setting on the HOT LIMIT
SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before
making adjustment to HOT LIMIT STOP (1). Pull forward and rotate
counterclockwise one number to limit hot water temperature.
Use NUMBERS (5) on CARTRIDGE (4) on HOT LIMIT STOP (1)
for indication.
ADJUST HOT LIMIT STOP
COLDER
(Larger Numbers)
1 2 3 4 5 6 7 8 9 10
HOTTER
(Smaller Numbers)
1 2 3 4 5 6 7 8 9 10
3
4
1
5
2
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE, see STEP 1 and STEP 2 and REVERSE process.
Clean SEALS on the side of CARTRIDGE. Clean inside sealing surface of VALVE BODY.
Re-assemble CARTRIDGE. Install trim. Turn on water supply and check for leaks.
REPLACING CARTRIDGE
To remove CARTRIDGE (1), install split WASHER (3) between the ridge on the cartridge and the bonnet nut (only
supplied with replacement cartridge) as shown.
Proceed to unthread BONNET NUT (2) counter clockwise.
Note: CARTRIDGE (1) should be pulling out while unthreading BONNET NUT (2).
Upon removal of the old Cartridge, install a new cartridge and secure it with BONNET NUT
(Hand tighten).
BACK TO BACK INSTALLATION
NOTE: Must purchase specialized back to back cartridge. (Part number M970640-0070A)
• Remove CARTRIDGE (1) as detailed in steps above.
• Install back to back cartridge.
Remove HANDLE (see step 3 and reverse).
Remove ESCUTCHEON and CARTRIDGE CAP (see step 1 and reverse).
SERVICE
TO GAIN ACCESS TO VALVE FOR SERVICING
CAUTION
Turn off hot and cold water
supplies before beginning.
Figure 1.
1
3
2
- 4 -- 4 -
M965929 Rev. 1.0 (12/18)
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
M970092-YYY0A
Shower Arm & Flange
1660739.YYY
Shower Head
(2.5 gpm)
1660738.YYY
Shower Head
(1.75 gpm)
M907858-YYY0A
Escutcheon
M907053-YYY0A
Cartridge Cap
M970281-YYY0A
Handle Kit
8888101.YYY
Tub Spout
M970457-0070A
Adaptor Kit
078016-0020A
Escutcheon Screw
M907414-YYY0A
Decorative Ring
M970410-0070A
Cartridge
M954805-YYY0A
Deep rough-in kit
PURCHASE SEPARATELY
C
H
OFF
PURCHASE SEPARATELY
M970640-0070A
Back-to-Back
Cartridge
Patience
Pressure Balancing
Bath and Shower Trim Kit
MODEL NUMBER
TU106500
TU106501
TU106502
TU106507
TU106508
Replace the “YYY” with
appropriate nish code
POLISHED CHROME 002
POLISHED NICKEL 013
LEGACY BRONZE 278
BRUSHED NICKEL 295
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

American Standard TU106507.278 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI