5
MAINTENANCE
Electrical shock hazard. Before removing
fixture from pool wall, ALWAYS TURN OFF THE POWER
at the breaker. Installation and maintenance of this cir-
cuit, the light, light niche, and any other accessories
attached to this circuit must be performed by a licensed
electrician. The complete electrical system must be
installed, tested, and approved by a licensed electrician
before it is placed in operation.
Risk of cuts, burns, and electrical shock.
Avoid direct impacts on glass lens. Do not install dam-
aged or broken lens.
For Sunsaver™ Lamps
See Figure 2, Page 6, for Key numbers.
1. Be sure the power is off. Allow the lamp to cool
before relamping.
2. Remove niche leader screw (Key No. 1 ) in the top
center of face ring.
3. Tilt the fixture out of the niche, remove from the water
and place face down on the pool deck.
4. Place the head of a flat head screw driver into the “V”
shaped space (located on the face ring), Key No. 2,
between each snap fit arm and the fixture housing
(Key No. 5) and twist. Repeat for all eight snap fit
arms.
5. 12V model: Pull left lamp straight out to the right and
pull right lamp straight out to the left.
120V model: Slide the lamp to the right and swing the
left end down until it clears the lamp housing enough
to pull the lamp out of the right socket.
6. Using a clean soft lint free cloth, carefully wipe all
sealing surfaces on the lamp housing and lens.
Replace lamp with an equivalent to the original lamp.
NOTE: Do not touch lamp with bare fingers. If contact
occurs, clean lamp glass with alcohol and a clean
cloth.
7. 12V model: Push each lamp straight into its socket.
Replace both lamps at the same time to maximize
lamp life.
120V model: Following the first arrow engraved on
the reflector, insert the right end of the lamp into the
socket first. Swing the left end of the lamp up into the
slot cut inside the reflector while pushing the lamp all
the way to the right. Follow the second arrow with the
left end into the left socket.
8. Check through the peep holes to assure both ends of
the lamp rest on the metal contacts of each socket.
For Sunbrite™ Lamps
See Figure 3, Page 7, for Key numbers.
1. Be sure that the power is off. Allow the lamp to cool
before re-lamping.
2. Loosen the captive leader screw (Key No. 1) from the
top of the fixture face ring (Key No. 2)
NOTICE: The screw in the face ring may be recessed.
3. Remove the lamp housing (Key No. 6) and place on
the pool deck.
4. Using a clean soft lint free cloth, carefully wipe all
sealing surfaces on the lamp housing and lens.
Replace lamp with an equivalent to the original lamp.
5. Replace the gasket (Key No. 4).
6. To reassemble the lens assembly to the lamp housing,
reverse the disassembly process. Be sure that the lamp
housing is clean, dry, and free of all traces of mois-
ture, before sealing the fixture.
7. Wind the extra cord around the lamp housing and
place the lamp housing back in the niche. Be sure to
align the locator tab at the bottom of the lamp hous-
ing with the notch in the bottom of the niche.
8. Fasten the lamp housing into the niche using the cap-
tive leader screw (Key No. 1) at the top of the trim
ring.
SPECIFICATIONS
Stainless Steel Thermoplastic Cord Length
Model Model in Feet (m)
12 Volts -
100 Watts
05201-2296 05101-2268 15 (4.5)
05201-2297 05101-2269 30 (9.1)
05201-2298 05101-2270 50 (15.2)
05201-2299 05101-2271 75 (22.8)
05201-2300 05101-2272 100 (30.5)
05201-2301 05101-2273 125 (38.1)
05201-2302 05101-2274 150 (45.7)
12 Volts -
200 Watts
05201-2303 05101-2275 15 (4.5)
05201-2204 05101-2276 30 (9.1)
05201-2205 05101-2277 50 (15.2)
05201-2206 05101-2278 75 (22.8)
05201-2207 05101-2279 100 (30.5)
05201-2208 05101-2280 125 (38.1)
05201-2209 05101-2281 150 (45.7)
120 Volts -
300 Watts
05202-2282 05102-2254 15 (4.5)
05202-2283 05102-2255 30 (9.1)
05202-2284 05102-2256 50 (15.2)
05202-2285 05102-2257 75 (22.8)
05202-2286 05102-2258 100 (30.5)
05202-2287 05102-2259 125 (38.1)
05202-2288 05102-2260 150 (45.7)
120 Volts -
500 Watts
05202-2289 05102-2261 15 (4.5)
05202-2290 05102-2262 30 (9.1)
05202-2291 05102-2263 50 (15.2)
05202-2292 05102-2264 75 (22.8)
05202-2293 05102-2265 100 (30.5)
05202-2294 05102-2266 125 (38.1)
05202-2295 05102-2267 150 (45.7)
Sunsaver™ Large Underwater Pool Lights (Canada)