Mugnaini G140 PA Installation, Operation and Maintenance Manual

Category
Ovens
Type
Installation, Operation and Maintenance Manual

This manual is also suitable for

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Mugnaini Commercial Gas Fired Ovens have been tested to:
ANSI Z83.11 & CAN/CGA–1.8
UL Subject 2162–2001 Safety Standards
NSF–4 Sanitation Standards
A MAJOR CAUSE OF OVEN-RELATED FIRES IS FAILURE
TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST
IMPORTANCE THAT THIS OVEN BE INSTALLED ONLY IN
ACCORDANCE WITH THESE INSTRUCTIONS.
MUGNAINI®
ITALY’S ORIGINAL PIZZA OVEN
MUGNAINI®
ITALY’S ORIGINAL PIZZA OVEN
Mugnaini Series
COMMERCIAL GAS FIRED OVEN
MUGNAINI®
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS OVEN
THIS MANUAL COVERS THE FOLLOWING TUSCANY SERIES MODELS:
G100 PA G120 PA G140 PA G160X140 PA G180X140 PA
WARNING
WHEN THIS OVEN IS NOT PROPERLY INSTALLED, A FIRE MAY RESULT. TO
REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS.
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL THE OVEN.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY AND EVEN DEATH.
WARNING
DO NOT PACK THE REQUIRED 1 AIR SPACES WITH INSULATION OR
OTHER MATERIAL.
INSTALLATION OF THE EXHAUST VENT SHALL BE IN ACCORDANCE
WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE
PROTECTION OF COMMERCIAL COOKING OPERATIONS, NFPA96.
SEEK OUT QUALIFIED INSTALLERS IN YOUR AREA AND
OBTAIN THE PROPER PERMITS. IN THE ABSENCE OF LOCAL
CODES; USE NATIONAL FUEL GAS CODE ANSI Z223.1.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS CONCERNING ANY INSTALLATION
RESTRICTIONS OR NEED FOR INSPECTION OF THE INSTALLATION.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCES.
SAVE THESE INSTRUCTIONS FOR FUTURE USE
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
TABLE OF CONTENTS
INSTALLATION INSTRUCTIONS
1. RECEIVING THE OVEN
1.1 DELIVERY LOCATION 4
1.2 CRATE CONTENTS 4
1.3 FORKLIFT AND PALLET JACK
REQUIREMENTS 4
2. UNLOADING, MOVING AND SETTING THE OVEN
2.1 UNLOADING THE OVEN: FORKLIFT REQUIRED! 5
2.2 OPENING THE CRATE 5
2.3 TOOLS REQUIRED 5
2.4 MOVING THE OVEN 6
3. CLEARANCES AND FACADES
3.1 SETTING THE OVEN 7
3.2 CLEARANCES TO COMBUSTIBLE CONSTRUCTION 7
3.3 INSTALLATION ACCESSORIES 8
3.4 FINISH MATERIALS 8
3.5 COVERING THE ARCH 8
4. VENTING THE OVEN
4.1 OVERVIEW 9
4.2 EXHAUST VENT REQUIREMENTS 9
5. DIRECT VENTING WITH FACTORY BUILT CHIMNEY
5.1 DIRECT VENT REQUIREMENTS USING FACTORY BUILT CHIMNEYS 10
5.2 ADDITIONAL REQUIREMENTS FOR CANADA 10
5.3 OVEN FLUE OUTLET 10
5.4 CONNECTING FACTORY BUILT CHIMNEY TO OVEN 10
6. DIRECT VENTING WITH FACTORY BUILT GREASE DUCT
6.1 DIRECT VENT REQUIREMENTS USING FACTORY BUILT GREASE DUCT 11
6.2 ADDITIONAL REQUIREMENTS FOR CANADA 11
6.3 OVEN FLUE OUTLET 11
6.4 CONNECTING FACTORY BUILT GREASE DUCT TO OVEN 11
7. INDIRECT VENTING
7.1 INDIRECT VENTING REQUIREMENTS 12
7.2 TYPE 1 HOOD 12
OPERATING AND MAINTENANCE INSTRUCTIONS
8. CURING THE OVEN
8.1 CURING PROCESS 13
9. FIRING THE OVEN
9.1 OVEN TOOLS REQUIRED FOR OPERATING YOUR MUGNAINI WOOD FIRED OVEN 14
9.2 CONTROL BOX 15
9.3 DAILY OPERATIONS 16
9.4 DAILY START UP 16
9.5 PRE-HEAT 16
9.6 AUTOMATIC MODE 16
9.7 MANUAL MODE 16
9.8 DAILY SHUT DOWN 16
9.9 COOKING ENVIRONMENTS 17
9.10 PIZZA OVEN ENVIRONMENT 17
9.11 ROASTING OVEN ENVIRONMENT 17
9.12 BAKE OVEN ENVIRONMENT 17
10. MAINTENANCE INSTRUCTIONS
10.1 GREASE FORMATION AND THE NEED FOR REMOVAL 18
10.2 DAILY MAINTENANCE 18
10.3 MONTHLY MAINTENANCE 18
10.4 DIRTY FLOOR MAINTENANCE 18
11. LIMITED WARRANTY
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 4
INSTALLATION INSTRUCTIONS
1. RECEIVING THE OVEN
Your oven will be shipped via Common Carrier from our Watsonville, California facility. You will need a
forklift to remove the crated oven from the truck. Once o the truck the oven can be moved with a pallet
jack. We will notify you when your oven is shipped and provide you with the PRO number (tracking
number) and the trucking companys contact number. It is always important to call the trucking company
in advance to coordinate the delivery.
NOTE: Once your oven is loaded onto a truck you have created a contract between you and the
trucking company. Mugnaini Imports does not control the delivery of your oven.
1.1 DELIVERY LOCATION
Proper planning is essential to a successful delivery. Be realistic about where you plan to take delivery of
your oven; commercial ovens are large and top heavy! Be sure to take into account the size of your oven
and entry into your building. It is common to remove doors, windows or open walls to gain access. Seek
out a qualied professional to ensure you are prepared for your installation. The trucker will require a at,
level surface safe from trac. A forklift will need to maneuver to remove the crated oven from the truck
and place it on the ground for uncrating.
NOTE: It is your responsibility to have a safe delivery location for the trucking company. Re-
delivery and re-consignment fees may be assessed if the oven cannot be o loaded. If you do not
have a safe or convenient location for unloading the truck, consider receiving the oven at another
location and having a professional deliver the oven to your location.
1.2 CRATE CONTENTS
• Fully assembled gas red oven on steel stand
• Spitre gas burner with control box (to be
mounted on front of oven enclosure)
• Stainless steel shelf (loose, bolt in place)
• Metal door (loose)
1.3 FORKLIFT AND PALLET JACK
REQUIREMENTS
Model Approx.
Wt.
Forklift
Reqd
Fork Length
100 PA 2300 lb.. 5000 lb.. 48 inches min.
120 PA 2750 lb.. 6000 lb.. 48 inches min.
140 PA 3600 lb.. 8000 lb.. 72 inches min.
160 PA 3950 lb.. 10000 lb.. 72 inches min.
180 PA 4450 lb.. 10000 lb.. 72 inches min.
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 5
2. UNLOADING, MOVING AND SETTING THE OVEN
2.1 UNLOADING THE OVEN: FORKLIFT REQUIRED!
The oven is shipped bolted to a sturdy pallet with open slat walls on all sides to allow for visual inspection.
Remove the crated oven from the truck using the appropriate forklift (see Receiving the Oven). Be sure
the forks are long enough to reach the rear supporting members of the crate.
IF THE FORKS ARE NOT LONG ENOUGH TO SUPPORT THE ENTIRE CRATE DO NOT ATTEMPT TO MOVE
THE OVEN - IT WILL TIP OVER. OBTAIN ANOTHER FORKLIFT OR USE FORK EXTENSIONS.
Once the oven is lifted from the truck immediately lower it to the ground, do not attempt to move the
oven while crated. Remove the plastic wrap and inspect the oven. Note any damage to the crate, oven or
accessories.
DO NOT SIGN THE DELIVERY BILL UNTIL THE OVEN HAS BEEN INSPECTED AND ANY DAMAGE
NOTED ON THE DELIVERY BILL. CALL OUR OFFICE IMMEDIATELY IF THERE ARE ANY SIGNS OF
DAMAGE: 888.887.7206.
2.2 OPENING THE CRATE
The oven crate is wrapped in plastic and metal banding. Parts and any accessories will be strapped to the
base and sides of the crate. The wooden slats that form the walls and roof are attached with screws, nails
and staples. The oven feet are lag bolted to the pallet base. Remove all strapping, parts and accessories
and disassemble the crate. Remove the lag bolts. The oven is now ready to be moved.
2.3 TOOLS REQUIRED
• Diagonalcuttersandrazorknife
• Hammerandprybar
• Screwgunandbits
• Socketset
WARNING
ONLY PROPER HEAVY LIFTING MACHINERY AND HEAVY LIFTING EQUIPMENT SHOULD BE USED
FOR UNLOADING, MOVING AND INSTALLING THE OVEN. THIS DUTY SHOULD BE PERFORMED BY
PROFESSIONALS TRAINED IN THIS KIND OF WORK. IMPROPER HANDLING OF THE EQUIPMENT
COULD RESULT IN DAMAGING THE OVEN OR PERSONAL INJURY AND EVEN DEATH.
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 6
2.4 MOVING THE OVEN
Use the forklift to move the oven (paying careful attention to the grade) to the entry point of the
restaurant. You may lift from any side but make sure to lift at the base of the oven body letting the steel
stand hang below. The stand can be removed if necessary.
Once the oven has been placed near or inside of the restaurant, use the pallet jack to move the oven to
the installation location. It may be necessary to place steel bars or heavy wood beams across the forks
of the pallet jack to fully engage the pallet jack. Move into place and slowly lower. You can make ne
adjustments using a long pry bar or length of wood against the stand to nudge the oven into place. Shim
as necessary to level oven.
Lift from under the body of the oven
Use bar across pallet jack to support oven
Move with pallet jack under stand
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 7
30” 30”
36”
Non-combustible
oor or oor covering
Oven front
1/2” Concrete board
Wood stud
Metal stud
1” Min
1” Min
1” Min
3. CLEARANCES AND FACADES
3.1 SETTING THE OVEN
Secure oven to oor with four [4] fasteners a minimum of 3/8” diameter. Insert at least one fastener,
appropriate for the oor, per steel mounting foot embedded 2 ½” minimum.
3.2 CLEARANCES TO COMBUSTIBLE CONSTRUCTION
The oven requires a 1” clearance on back wall and side walls to any combustible materials. Do not pack
the air gap with insulation or other material. You may bridge the gap between the oven and façade wall
with metal stud framing and concrete board. A metal stud may be fastened directly to the steel sides of
the oven. Use ½” Durock brand concrete board,or similar, to transition to any wood framing.
Clearances to Combustible Construction
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 8
3.3 INSTALLATION ACCESSORIES
Side panels are available from Mugnaini to frame in the stand on freestanding ovens. If the base of the
oven is to be completely enclosed; use the optional Gas Cover Panel Kit to ensure adequate combustion
air reaches the burner.
3.4 FINISH MATERIALS
Use only non-combustible materials such as tile, brick or stone, to nish your installation. You may attach
1/2” concrete board directly to the ovens metal enclosure. Use metal framing braced to the oven in order
to build a facade wall or transition to combustible construction.
Framing for a facade wall or site built side panel should be assembled using metal studs and 1/2” concrete
board. Non-combustible nish materials may be applied to the concrete board.
Optional side
panels
Optional Gas
Cover Panel Kit
Metal stud framing with 1/2”
concrete board
Optional Gas
Cover Panel Kit
Metal stud
framing
1/2” Concrete
board
Side panels for free standing ovens
attach to the oven stand.
3.5 COVERING THE ARCH
The arch is not removable but may be covered with ceramic tile or similar non-combustible material.
Remove the paint on the arch to create a proper bonding surface. Use Thinset or other cement based
product to mount tiles. Do not use adhesives or glue to attach nish materials to front panel or arch.
CHECK WITH LOCAL HEALTH DEPARTMENT REGARDING ACCEPTABLE MATERIALS FOR THE ARCH
OR FRONT PANEL.
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 9
4. VENTING THE OVEN
4.1 OVERVIEW
The oven may be vented in a variety of ways depending upon the usage, the building the oven is installed
in and restrictions due to local codes. It is very important to take into consideration the complete venting
system, including maintenance, before committing to a location.
SEEK OUT QUALIFIED INSTALLERS IN YOUR AREA AND OBTAIN THE PROPER PERMITS. MANY
BUILDING AND PLANNING DEPARTMENTS REQUIRE MECHANICAL DRAWINGS OF THE VENTING
SYSTEM DEMONSTRATING CODE COMPLIANCE.
4.2 EXHAUST VENT REQUIREMENTS
Installation of the exhaust vent shall be in accordance with the Standard for Ventilation Control and Fire
Protection of Commercial Cooking Operations, NFPA 96. This code references UL 737 for direct venting
and UL 2162 for indirect venting.
The oven may be vented in either of the following methods:
1. Direct vent by connecting the oven to an approved 8” factory built chimney pipe per UL 737.
2. Indirect vent by installing the oven under a Type 1 Grease Hood per UL 2162.
SINGLE WALL AND B-TYPE VENT PIPES ARE NOT ACCEPTABLE FOR THIS TYPE OF APPLIANCE!
IT IS IMPORTANT FOR THE INSTALLER TO CONTACT THE LOCAL BUILDING OR FIRE INSPECTOR TO
DETERMINE WHICH VENTING METHOD IS ACCEPTABLE.
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 10
5. DIRECT VENTING WITH FACTORY BUILT CHIMNEY
5.1 DIRECT VENT REQUIREMENTS USING FACTORY BUILT CHIMNEYS
• Oven installations utilizing direct vent insulated chimneys must comply with UL 737 and NFPA 96
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
• Factory built insulated chimneys must be listed to UL 103 HT or ULC S627.
• Example chimney pipe: Simpson DuraTech www.duravent.com
• Applicable for building with chimneys 3 stories or less
• 2 sets of osets (elbows) allowed (15 or 30 degree angles only)
• Attach chimney anchor plate to oven using Direct Vent Flue Adaptor - part# DVA
• Chimney must be installed per chimney manufacturers installation instructions
• Chimney must terminate to an approved chimney cap with spark arrestor (screen mesh)
• Chimney lengths 25 feet or longer may require an exhaust fan. The Enervex GSV series fan is listed
for use with a wood burning pizza oven see: http://www.greasefans.com
• Applicable for pizza and bread products only
5.2 ADDITIONAL REQUIREMENTS FOR CANADA
• The use of smoke detectors is highly recommended
• The chimney connector shall not pass through an attic, roof space, closet oor, ceiling, or similar
concealed space. Where passage through a wall or partition of combustible construction is desired,
the installation shall conform with CAN/CSA-B365
5.3 OVEN FLUE OUTLET
• Flue size: 8” round (internal diameter)
• Flue location: on top of oven centered above arch, 7 3/8”
(+/- 1”) behind the front panel
5.4 CONNECTING FACTORY
BUILT CHIMNEY TO OVEN
Mugnaini oers an optional Direct Vent Flue Adaptor for
installation in the factory. Part# DVA is a ush mount adaptor
designed to accept a standard Anchor Plate used with UL 103
double wall insulated chimney.
Part# DVA with anchor plate adaptor
(anchor plate not supplied)
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 11
6. DIRECT VENTING WITH FACTORY BUILT GREASE DUCT
6.1 DIRECT VENT REQUIREMENTS USING FACTORY BUILT GREASE DUCT
• Oven installations utilizing direct vent grease duct must comply with NFPA 96
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
• Factory built grease duct assemblies must be listed to UL 1978
• Example grease duct: Metal Fab G-Series www.metal-fabinc.com
• Ideal for complicated runs, long lengths or horizontal runs
• Weld grease duct starter piece to oven using Direct Vent Flue Adaptor - part# GDV
• Chimney must be installed per chimney manufacturers installation instructions
• Chimney must terminate to an approved chimney cap with spark arrestor (screen mesh)
• Chimney lengths 25 feet or longer may require an exhaust fan. The Enervex GSV series fan is listed
for use with a wood burning pizza oven see: http://www.greasefans.com
• Applicable for any menus including cooking meat
6.2 ADDITIONAL REQUIREMENTS FOR CANADA
• The use of smoke detectors is highly recommended
• The chimney connector shall not pass through an attic, roof space, closet oor, ceiling, or similar
concealed space. Where passage through a wall or partition of combustible construction is desired,
the installation shall conform with CAN/CSA-B365
6.3 OVEN FLUE OUTLET
• Flue size: 8” round (internal diameter)
• Flue location: on top of oven centered above arch, 7 3/8”
(+/- 1”) behind the front panel
6.4 CONNECTING FACTORY BUILT
GREASE DUCT TO OVEN
Mugnaini oers an optional Direct Vent Flue Adaptor for
installation in the factory. Part# GDV has a 2” weldable stainless
stub for a eld welded grease duct adaptor.
Part # GDV Grease duct adaptor
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 12
7. INDIRECT VENTING
7.1 INDIRECT VENTING REQUIREMENTS
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
• Oven installations using indirect venting require a Type 1 Hood listed to UL 710
• The hood shall allow adequate clearance for removal and cleaning of the grease baes (Captive
Aire model SND is a low prole hood that enhances access)
• Fire suppression system shall be used in the hood only and not pointed into the oven
• Flue outlet temperatures reach 550 F so be sure to place fusible link appropriately
• May be vented with single wall grease duct or insulated factory built grease duct list to UL 1978
• Example grease duct: Metal Fab G-Series www.metal-fabinc.com
• Exhaust fan listed for use with a wood burning oven is recommended. The Enervex GSV series fan is
listed for use with a wood burning pizza oven see: http://www.greasefans.com
7.2 TYPE 1 HOOD
• Minimum Type 1 Hood dimensions: 36” wide x 42” deep
• Example: Captive Aire model SND Exhaust Hood www.captiveaire.com
• Install hood directly on top of oven using ceiling supports
• The hood shall extend 12” beyond the front of the oven opening (arch/mouth) and extend 6”
beyond the sides of the oven opening. See diagrams on following page.
SEEK OUT A QUALIFIED PROFESSIONAL TO DESIGN AND INSTALL YOUR VENTING
SYSTEM. CHECK WITH LOCAL AUTHORITIES FOR SPECIFIC CODE REQUIREMENTS
Type 1 Hood Placement
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 13
OPERATING AND MAINTENANCE INSTRUCTIONS
8. CURING THE OVEN
Once the installation of your gas-burning oven is complete, it is necessary to “CURE” the oven to eliminate
any potential moisture within the walls and oor. The task is to slowly increase the heat inside the oven
without using high heat. As you begin to use your oven, ne shallow cracks will become noticeable in the
inner lining of the walls. This is to be expected as a result of the thermal expansion and does not indicate
a failure of the material. However, if excessive moisture is allowed to migrate into the walls, deep and
potentially damaging cracks in the clay elements could result at high temperatures.
IT IS IMPORTANT TO COMPLETE THE CURING PROCESS BEFORE USING THE OVEN AT MAXIMUM
HEAT.
8.1 CURING PROCESS
Day 1: Fire the oven on the lowest setting for 4 hours
• After 4 hours turn the power o and place the door in the fully closed position.
• Leave overnight to allow heat to saturate oven components.
• Do not continue to re the oven for more than 4 hours or at a higher temperature.
Day 2: Fire the oven on the lowest setting and then raise temperature hourly for 6 hours
• Turn the power on and select Min setting. Fire for one hour.
• Select Auto, press Set button and use arrows to change set point to 65 C, press Set.
• Use the FIRE CONTROL arrows to set the power between 20-40%.
• Every hour, increase the set point 25 C.
• Fire for 6 hours or more.
• Turn the power o and place the door in the fully closed position.
Day 3: Fire the oven on the lowest setting and then raise to operating temperature
• Turn the power on and select the Min setting. Fire for 20 minutes.
• Select Auto, press Set button and use arrows to change set point to 125 C, press Set.
• After the oven has come up to temperature raise set point to 250 C.
• Use the FIRE CONTROL arrows to set the power between 20-40%.
• Allow oven to come up to pizza temperature and maintain for 6 hours.
• You may now cook as soon as the oven is up to temperature.
Your Mugnaini gas red oven is now fully cured and ready for service!
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 14
9. FIRING THE OVEN
The Mugnaini Gas Fired Pizza Oven is an open hearth appliance designed to cook with high heat and
a live re. The oven may be utilized for a variety of cooking techniques such as high heat roasting, as a
bake oven and of course a pizza oven. No matter what style of cooking you intend on using, the oven
must always be pre-heated and then regulated to the desired operating temperature following these
instructions.
PRECAUTIONS
READ ALL INSTRUCTIONS CAREFULLY. IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A
BUILDING FIRE OR PERSONAL INJURY. INSTRUCTIONS SHOULD BE THOROUGHLY UNDERSTOOD
BY ALL OPERATING AND SUPERVISING PERSONNEL.
THIS OVEN IS INTENDED FOR OPERATION BY TRAINED AND QUALIFIED PERSONNEL ONLY.
DO NOT OVER FIRE. IF FLAMES EXTEND BEYOND THE OVEN DOOR OPENING, YOU ARE OVER-
FIRING.
DO NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH THIS OVEN.
NEVER USE WATER OR ICE TO LOWER TEMPERATURE INSIDE THE OVEN.
9.1 OVEN TOOLS REQUIRED FOR OPERATING YOUR MUGNAINI GAS FIRED OVEN
• Long handle metal peel with 8” round head
• Long handle oor brush with brass bristles
• Pizza peel of choice, metal or wood
• Hand held infrared thermometer rated to 750 F and set to .95 emmissivity
• Metal door (included with oven)
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 15
9.2 CONTROL BOX
The Spitre gas burner system is a sophisticated controller that can be used in either a Manual mode or an
Automatic mode with Set Point. In addition, the size of the ame can be regulated independently of the
oven temperature.
9.2.1 POWER BUTTON
The power switch is the button in the top left corner of
the control box. A green light will be illumined when the
burner is on.
9.2.2 OVEN TEMPERATURE
The oven temperature is display with LED numbers in the
middle of the control box. The Spitre burner system reads
the oven temperature in front of the burner using a thermal
couple. While this number is accurate, it is primarily used as
a guide for setting the burner not for cooking. See Cooking
Environments for details.
9.2.3 SET POINT
The Set button is pressed to change the Target
temperature or set point of the burner when in Auto mode.
Press Set and then use the up and down arrows to change
the set point. Press Set again to lock in the set point. The
Spitre burner will automatically raise and lower the ame
to maintain that temperature.
NOTE:Theactualtemperatureinsidetheovenwillbedierentthanthetemperaturedisplayedonthe
controlbox.ThisSetPointshouldbeusedinconjunctionwithaninfraredthermometertobalance
theovenforthedesiredcookingenvironment.Testvarioussetpointsin10degreeincrementsto
determinethesetpointthatachievesthedesiredoortemperature.
9.2.4 RESET BUTTON
If the oven loses its ame, the Reset button will be illumined. Press the Reset button to relight the burner.
If the burner goes out three times in a row contact Mugnaini service department to rectify the problem.
9.2.5 FIRE CONTROL
The size or intensity of the ame can be changed by pressing the up or down arrows to achieve the
desired ame.
9.2.6 MAX BUTTON
Press the Max button to allow the oven to run at maximum power. The ame can be adjusted manually by
using the Fire Control up and down arrows.
9.2.7 AUTO BUTTON
Press the Auto button to manage the oven based on the set point. See Set Point for details.
9.2.8 MIN BUTTON
Press the Min button to run the oven with the smallest ame. Use this mode when pre-heating an oven or
to keep a hot oven stable between lunch and dinner service.
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 16
9.3 DAILY OPERATIONS
The goal for daily service is to have an oven that is pre-heated with a live ame regulated to the manner in
which you wish to cook. The oven can be used in the Manual mode or in the Automatic mode by pressing
the appropriate button. Either mode requires a handheld infrared thermometer set to read Fahrenheit to
accurately read the oor temperature where you are cooking.
9.4 DAILY START UP
Remove oven door and remove any debris using the oor brush.
9.5 PRE-HEAT
Press the power button to turn the oven on. The ambient air temperature is shown in Celsius. It is a good
practice to use the Min setting to pre-heat the oven for 20 minutes prior to using the automatic or manual
modes.
9.6 AUTOMATIC MODE
Press the Auto button to put the oven in automatic mode. The oven will now self regulate according to
the Target Temperature or set point. Pressing the Set button will display the set point. Press and hold
the Set button to change the set point using the up and down arrows. Press Set again to lock in the set
point. Remember, the set point is used to regulate the burner and is not an accurate measurement of the
cooking surface so just use it as a guide.
9.7 MANUAL MODE
Press the Min button to re the oven with the lowest ame setting.
Press the Max button to re the oven with the highest ame setting.
Use the up and down arrows to ramp the ame up or down to the desired size.
Spitre rates the size of the ame as a percentage of the maximum ame.
NOTE: At any time you may press the up and down arrows to change the size of the ame
9.8 DAILY SHUT DOWN
At the end of service simply press the power button to turn o the burner system and place the door
inside the arch in the fully closed position. To close the door, angle the door as you insert it inside the arch
and then straighten it up and push it back all the way in an upright position.
Photo instruction and oven accessories are available on our website: www.mugnaini.com
Please call our oce 888.887.7206 for more personalized instruction, to schedule a class or to purchase
any accessories you may need.
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 17
9.9 COOKING ENVIRONMENTS
Once your oven has been pre-heated, you will need to regulate it for the style of cooking you will be
doing. All cooking methods in an open hearth pizza oven are based on oor temperature and the size of
the ame. Floor temperatures are best measured with a handheld infrared thermometer. Regardless of the
target temperature (set point) on the gas control box; you will always want to read the oor temperature
with the infrared thermometer and adjust the set point to achieve the desired cooking environment.
9.10 PIZZA OVEN ENVIRONMENT
This is dened as a hot oven having a oor temperature of 650-750 F and a live ame reaching the middle
of the oven or further. Naturally, your product will determine the temperature you can bake at but you
can think of the oor temperature and the ame size as a ratio. Then you can adjust your dough and
toppings to work for either a bake time or a oor temperature. Expect to adjust the ame manually or use
the automatic system as service changes throughout the day. The door is removed for pizza service.
FLOOR TEMP (use infrared
thermometer)
FLAME SIZE (use Fire Control arrows
to adjust)
PIZZA BAKE TIME (approx. range)
750 F or more Reaching past the middle of dome 1 ½ minutes
650 F Reaching the middle of dome 2 ½ minutes
550 F Reaching up the side dome 4-5 minutes
9.11 ROASTING OVEN ENVIRONMENT
High heat roasting of meats and vegetables is achieved with a oor temperature of 550 -600 F and a
maintenance ame that reaches just up the side of the oven but not across the top. The door may be
placed at a slight angle on the shelf in front of the arch. If black soot accumulates on the oven dome then
either turn down the ame or open the door to allow more air into the oven.
9.12 BAKE OVEN ENVIRONMENT
You can still cook in your oven using only the retained heat stored deep in the oven walls and oor. Bread
can be baked the next morning or meats roasted between and after service with no ame. The door is
placed in the fully closed position: an upright position fully inserted behind the arch to close o the bake
chamber.
WARNING
THE BURNER SYSTEM MUST BE TURNED OFF IF THE DOOR IS FULLY CLOSED.NEVER USE WATER
OR ICE TO LOWER TEMPERATURE INSIDE THE OVEN.
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 18
10. MAINTENANCE INSTRUCTIONS
WARNING
READ ALL INSTRUCTIONS CAREFULLY. IMPROPER USE OR MAINTENANCE OF THIS OVEN MAY
RESULT IN A BUILDING FIRE OR PERSONAL INJURY.
10.1 GREASE FORMATION AND THE NEED FOR REMOVAL
When exhaust air is drawn through the ue, grease laden vapors may be present. These grease laden
vapors condense in the relatively cool oven ue or exhaust hood duct and residue accumulates on the
ue lining or ducting. When ignited this grease residue makes an extremely hot re. The exhaust hood
ducting should be inspected at least once a month or until a schedule of cleaning has been determined
by a qualied technician.
10.2 DAILY MAINTENANCE
The oven, exhaust hood and grease lters (if Type 1 hood is used) should be cleaned on a daily basis. The
grease lters can be removed and cleaned in a dishwasher or sink. Follow exhaust hood manufacturers
recommendations or NFPA 96 requirements for inspection, maintenance and cleaning.
10.3 MONTHLY MAINTENANCE
Seek out a qualied chimney sweep or exhaust duct service technician to inspect and clean the ue
system on a regular schedule starting monthly and adjust according to build up.
10.4 DIRTY FLOOR MAINTENANCE
Stains can be burned o the oven oor at the end of the day by using the Max setting for 30 - 45 minutes.
This is similar to a conventional ovens self cleaning mode. Allow the oven oor to raise to over 750 F and
brush o any debris. Be careful to not over re the oven.
Note: The scheduled maintenance cycle may change according to oven usage, the products cooked
and seasonal weather/HVAC changes.
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 19
11. LIMITED WARRANTY
MUGNAINI IMPORTS, INC. (“Mugnaini”), a California corporation, is a distributor of Italian wood-
burning residential and commercial ovens (the “Oven(s)”). Mugnaini warrants to the original
purchaser only (“Original Purchaser”) that the Oven will be free from defects in materials and
workmanship for a period of five (5) years from the date of delivery (“Warranty Period”).
Remedies available to the Original Purchaser against Mugnaini under this warranty are
limited to: (i) repair and replacement of parts and/or the necessary labor and services
required to repair the Oven; or, (ii) at Mugnaini’s option, refund of the purchase price.
Information in Mugnaini’s catalog or other information provided by Mugnaini is given after the exercise
of due care in its compilation, preparation, and issuance; however, Mugnaini disclaims any liability
resulting from such information, except for the obligation under the warranty provided herein.
NO OTHER EXPRESS WARRANTY IS GIVEN, AND NO AFFIRMATION OF MUGNAINI, BY WORDS OR ACTION,
SHALL CONSTITUTE AN ADDITIONAL WARRANTY. THIS WARRANTY IS NON-TRANSFERRABLE.
THIS WARRANTY IS EXPRESSLY IN LIEU OF AND EXCLUDES ALL OTHER EXPRESS OR IMPLIED WARRANTIES
WITH RESPECT TO THE OVEN OR ANY RELATED EQUIPMENT OR ACCESSORY, INCLUDING, BUT NOT
LIMITED TO, WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR PARTICULAR PURPOSE, USE OR
APPLICATION AND ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF MUGNAINI, UNLESS SUCH
OTHER WARRANTIES, OBLIGATIONS OR LIABILITIES ARE EXPRESSLY AGREED TO IN WRITING BY MUGNAINI.
This warranty shall not apply:
(a) to any Oven or related equipment or accessory that is improperly installed or maintained
(b) to products resold in other than Mugnaini original packaging or to
Ovens modified or altered by the Original Purchaser;
(c) to failure or malfunction of the Oven or any related accessories that is caused by improper use or any
failure to assemble or install pursuant to factory instructions; to any Oven or related accessories that
have been materially altered from the condition in which they were shipped to the Original Purchaser;
(e) to any cracking caused by overfiring, by failure to follow a proper curing schedule, or by
expansion or contraction in either refractory mortar or refractory Oven component;
(f) to normal wear and tear; and,
(g) to freight and shipping charges for sending an Oven to Mugnaini for repair.
All claims under warranty (“Warranty Claim(s)”) must be made within fifteen (15) days after
occurrence of circumstances giving rise therein and all Warranty Claims must be received
within the applicable Warranty Period by Mugnaini or its authorized representative. Any and
all rights under this warranty or at law of Original Purchaser against Mugnaini shall terminate and
be void in the event Warranty Claims are not submitted within the time set forth in the immediately
preceding sentence. Such Warranty Claims must be in writing and include the Oven type, the
model and serial number of the Oven, the purchase date and a full description of the circumstances
giving rise to the Warranty Claim. Warranty Claims under this warranty are to be mailed to:
MUGNAINI®
MUGNAINI SERIES
GAS FIRED OVEN MANUAL
Mugnaini Imports, Inc.
11 Hangar Way, Watsonville CA 95076
888.887.7206  │  831.761.7167  │  Fax:  831.728.5570
www.mugnaini.com  │  [email protected]
PAGE 20
MUGNAINI IMPORTS, INC.
11 Hangar Way
Watsonville, California 95076
Before any Oven is returned for repair, written authorization must be obtained from Mugnaini or its
authorized representative for the return and instructions, as to how and where the Oven should be
shipped. Any Oven returned to Mugnaini for examination shall be shipped with all shipping charges
prepaid, at Original Purchasers expense, via the means of transportation indicated as acceptable
by Mugnaini. Mugnaini reserves the right to reject any Warranty Claim not promptly reported and
any Warranty Claim on any Oven that has been altered or has been shipped by non-acceptable
means of transportation. When an Oven is returned for examination and inspection or for any other
reason, Original Purchaser shall be responsible for all damages resulting from improper packing or
handling and the risk of loss in transit, notwithstanding any defect or nonconformity in the Oven.
In all cases, Mugnaini has sole responsibility in its reasonable judgment for determining
the cause and nature of failure, and Mugnaini’s determination with regard thereto shall be
final and binding upon the Original Purchaser. If it is found that Mugnaini’s Oven has been
returned without cause and is still serviceable, Original Purchaser will be notified and the Oven
returned at Original Purchaser’s expense. In addition, a charge for testing and examination
may, in Mugnaini’s sole and reasonable discretion, be made on any Oven so returned.
THE LIABILITY OF MUGNAINI FOR WARRANTY CLAIMS (REGARDLESS OF THE LEGAL THEORY
ASSERTED, SUCH AS BREACH OF CONTRACT, BREACH OF WARRANTY, NEGLIGENCE, TORT, VIOLATION
OF STATUTE OR REGULATION, STRICT PRODUCTS LIABILITY, CONSUMER PROTECTION STATUTES
OR DECEPTIVE TRADE PRACTICES STATUTES); OR (2) DAMAGES (INCLUDING SETTLEMENTS,
JUDGMENTS AND AWARDS, AND COSTS, INCLUDING ATTORNEYS FEES AND EXPENSES INCURRED
IN DEFENDING CLAIMS) ARISING OUT OF THE OVEN, SHALL NOT BE GREATER THAN THE ACTUAL
PRICE OF THE OVEN WITH RESPECT TO WHICH THE WARRANTY CLAIM OR DAMAGES ARISES.
UNDER NO CIRCUMSTANCES IS MUGNAINI LIABLE FOR CONSEQUENTIAL, SPECIAL, INCIDENTAL OR
INDIRECT DAMAGES OF ANY KIND OR TYPE INCLUDING WITHOUT LIMITATION, CLAIMS FROM ORIGINAL
PURCHASER, OR OTHER THIRD PARTIES, PROSPECTIVE OR PRESENT LOSS OF PROFITS, BUSINESS
REPUTATION OR GOODWILL, EVEN IF MUGNAINI WAS AWARE OF A POTENTIAL FOR SUCH DAMAGE.
If Original Purchaser is not satisfied with the warranty service, the Original Purchaser must submit a
Warranty Claim in writing to Mugnaini’s Dispute Settlement Representative at 11 Hangar Way, Watsonville,
California 95076. The written notice must include the Oven type, the model and serial number of the
Oven, the purchase date, a detailed description of the problem and the address at which the Original
Purchaser can be reached. Mugnaini will review each notice and respond to the Original Purchaser
in an eort to settle such dispute. Under federal law, no lawsuit may be initiated unless and until the
dispute settlement procedures outlined in this warranty have been exhausted. Any Warranty Claim shall
be governed by and construed in accordance with the internal laws of the State of California. Original
Purchaser consents to the jurisdiction and venue of any court, federal or state, sitting in the State of
California, County of Santa Cruz, for the resolution of any dispute arising out of the Warranty Claim.
This warranty gives Original Purchaser specific legal rights, and Original Purchaser may also have
other rights that vary from state to state. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may not apply.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Mugnaini G140 PA Installation, Operation and Maintenance Manual

Category
Ovens
Type
Installation, Operation and Maintenance Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI