BELLSON ELECTRIC PAL Touch-5 Series Installation & Maintenance Instructions Manual

Type
Installation & Maintenance Instructions Manual
BELLSON ELECTRIC PTY LTD
www.bellson.com.au P.O. BOX 2966 TAREN POINT NSW 2229 FAX: (02) 9531 2666
1/3 CAPTAIN COOK DRIVE CARINGBAH NSW 2229 PHONE: (02) 9531 1555
INSTALLATION & MAINTENANCE
INSTRUCTIONS ON THE
PCR-5
4 CHANNEL
REMOTE CONTROL SYSTEM
FEATURES
Easy to Install
Approved to UL1563 & CSA C22.2 No. 218-1-13
Pending
Remote Control Operation from PCT-5
Transmitter
Optional Wi-Fi Control from Apple iOS Devices
or Android Devices
Optional Local Control from BR-04 Module
IP65 Wet Location Construction
PENDING
LIGHTING
TMTM
Page 2
INSTALLATION INSTRUCTIONS FOR PCR-5 4 CHANNEL REMOTE CONTROL SYSTEM
The PCR-5 4 Channel Remote Control System only works as a system with the
PCR-4 or PCR-200 PAL Colour Touch Drivers.
As shown in the illustration below the system is controlled by TOUCH from the
PCT-5 Transmitter or by optional Wi-Fi Control from Android or Apple Smart Phones
and Tablets.
To control the PCR-5 Remote Control Unit by Wi-Fi the PCR-4 or PCR-200 must be
fitted with the PAL Touch-5 Wi-Fi Module (Part No. 42-PCTWF5)
The PCR-5 can be fitted with the BR-04 module to provide local control with
LED Indication. This module can also be hardwired to provide remote control with
indication.
Optional BR-04
Local Control Module
IP65
PAL Pool Lighting
Channel 5
C
hannel 1 -
4
PAL Mini
4 Loads such as Pumps, Blowers, Heater, Valve Control
PAL LED Optics
PCR-4
CLASS 2 POWER SUPPLY FOR
PAL 4 WIRE LED LIGHTS
SUPPLY VOLTAGE = 100 - 240V (47 - 63 Hz)
SUPPLY CURRENT (TYP.) = 0.7A/115VAC, 0.3A/240VAC
OUTPUT VOLTAGE = 12V D/C
OUTPUT POWER = 50 WATTS
APPROVED TO IEC/AS/NZS 61347 NO. TUV15577EA & UL 8750
RECEIVER/DRIVER
TM
Tc :50 C
Suitable for
Wet Locations
IP65
o
E357127
LED DRIVER
4ZD6
IP65
4 CHANNEL REMOTE CONTROL
1
POWER ON
REMOTE CONTROL MODULE BTR-4
2
3 4
Page 3
IMPORTANT INFORMATION
The PCR-5 must be installed in accordance with the National Electrical Code by a Certified
Electrician or Qualified Pool Technician.
Step 1. The PCR-5 Enclosure must be located a minimum distance of 5 feet
measured horizontally from the inside wall of the pool and not less than 1 foot
above the maximum pool water level measured to the top of the PCR-5 Enclosure.
NOTE: The enclosure must be mounted using the mounting feet on the enclosure
with the 4x 6# x 3/4” long 316 grade stainless steel screw set supplied.
If the enclosure is to be mounted on a concrete or block wall:
Mark out the mounting hole locations and drill 3/16” holes using a masonry drill
then fit the Star Plugs supplied into the holes and fix using the stainless steel
screws supplied.
Step 2. Using the conduit entry in top right hand side of the PCR-5 (as shown)
connect the 100-120V power supply to the NEC code requirements.
Step 3. Using the conduit entries at the bottom of the PCR-5 (as shown)
to connect the switch wires to the Power Relays.
Step 4. The PCR-5 Driver / Receiver is factory set to operate with the PCT-5
Transmitter supplied. Just fit the 2 x batteries supplied with the PCT-5
and the Transmitter is coded ready to provide Touch control to the system.
Please refer to the information supplied with the PCT-5 transmitter for full
operating instructions and features of the system.
Step 5. To operate any of the four channels from the PCT-5 transmitter just simply press the
“ON” from the selected channel to start and by pressing “OFF” to turn off.
Channel 4 can control 2 Speed Pumps if wired as shown on Page 5.
If the “ON” button is pressed on Channel 4 once the motor will start in HIGH Speed.
To select LOW speed press the “ON” button twice and after 3 minutes to allow the
pump to prime in HIGH speed the power relays will change over to LOW speed.
NB: If the motor is run for longer than 3 minutes in HIGH speed by pressing the
“ON” button on Channel 4 it will change the power relays to LOW speed.
INSTALLATION INSTRUCTIONS FOR PCR-5 RGB OUTDOOR CONTROLLER
2 SPEED SELECTION ON CHANNEL 4
Page 4
INSTALLATION INSTRUCTIONS FOR PCR-5 RGB OUTDOOR CONTROLLER
Connect Loads to Power Relays as shown on Page 5
1 2 3 4
All PCR-5 drivers are
supplied with 1x PCT-5
Hand Held Transmitter
& Wall Holder
1/2" PVC
Conduit
1/2” PVC Conduit Adaptor
1/2” PVC
Conduit
Adaptor
To
Power
Supply
Note: Use the 4x Mounting Feet
to fasten the enclosure to
the wall with the screw
set supplied.
ELECTRONIC
POWER SUPPLY
100 - 240 AC/12V DC
& DRIVER/RECEIVER
V- CH4 AUX
EARTH ACTIVE NEUTRAL
E A N
COM
Low
Speed
High
Speed
R1
FZ1
FZ4
FZ2
FZ3
R2
R3
R4
R4A
LED 4A
Power On
Code Setting
LED
4CH-PCT 5U
ON
LED
ON
LED
ON
LED
ON
LED
Page 5
R1 R2 R3
CH1
TO CH1
LOAD
FROM
SUPPLY
FROM
SUPPLY
L1
N/L2
L1 N/L2
CH2
TO CH2
LOAD
L1
N/L2
L1 N/L2
FROM
SUPPLY
CH3
TO CH3
LOAD
L1
N/L2
L1 N/L2
R4A
R4
COM
Low
Speed
High
Speed
R4A
L1
L2
COM
N/ON/C
CH4
240V
2 SPEED
MOTOR
CABLE CONNECTION DETAILS FOR CHANNEL 4 FOR 240V 2 SPEED MOTOR
COM
Low
Speed
High
Speed
R4A
R4
L1
N
COM
N/ON/C
CH4
CH4A
120V
2 SPEED
MOTOR
CABLE CONNECTION DETAILS FOR CHANNEL 4 FOR 120V 2 SPEED MOTOR
CABLE CONNECTION DETAILS FOR CHANNEL 1, 2 & 3
TIMER INSTRUCTIONS
Page 6
TIME SETTING
To set the current time turn the minute Hand clockwise. Do not set the time by Rotating the “outer” dial.
Turn the minute hand clockwise until the time of day on the outer dial is aligned with the triangle
marker on the inner dial (two o’clock position).
Example for 24-hour program dial 11:00 AM. Turn the minute hand clockwise until 11:00 AM is aligned
with the triangle on the inner dial. The hour and the minute dial will show exactly 11:00.
The 24-Hour dial has quarter-hour divisions and AM/PM indications.
The time switch is programmed by pushing the captive trippers to the outer ring position for the entire
period that the load is to be turned “ON”, i.e., fifteen minutes for each tripper on the 24-Hour dial.
When the tripper is pushed to the inside, the switch is in the “OFF” position.
OPERATION
With the Time Clock programmed and set in Automatic Mode
The time clock will switch “ON” and “OFF” Channel 4 controlling the pump.
With the Time Clock “OFF”
Channel 4 can be switched “ON” & “OFF” from the PCT-3 Transmitter.
With the Time Clock “ON”
The PCT-3 Transmitter cannot switch “OFF” Channel 4.
NOTE: If the Channel 4 button on the PCT-3 Transmitter is pressed when the
Time Clock is “ON” channel 4 will stay “ON” after the time clock switches “OFF”
until channel 4 is turned “OFF” by the PCT-3 Transmitter.
TABS IN
TO SET “OFF”
OPERATION
TABS OUT
TO SET “ON”
OPERATION
DIMENSIONAL DETAILS
Publication No. P42-13AU Page 7
All PCR-5 remotes are
supplied with 1x PCT-5
Hand Held Transmitter
& Wall Holder
13/16” / 21.0mm
Knockout is fitted on the
bottom of both sides of the
enclosure
Knockout Instructions
It is recommended that the
cover is fitted and the cover
screws tight when the knockouts
are being removed.
When removing the knock outs
place a flat blade screwdriver with
a 3/16” (4mm) blade as shown
and a light hit with a hammer to
the head of the screw driver will
allow the Knockout to be removed.
Alternatively drill location points
are located in the centre of each
Knock out to allow the use of a
hole saw to remove the knockouts.
IP65
6 7/8” / 174.0mm
6 7/8” / 174.0mm
7 1/8” / 181.0mm
8 7/8” / 225.0mm
9 1/8” / 232.0mm
2 5/16” / 75.0mm 5/8” / 15.0mm
3 9/16” / 90.0mm
13/16” / 21.0mm
Knock Out
Drill Location
Points
13/16” / 21.0mm
Knockout to connect
power supply
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

BELLSON ELECTRIC PAL Touch-5 Series Installation & Maintenance Instructions Manual

Type
Installation & Maintenance Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI