NOTE:
This luminaire has been modied and can no longer operate the originally intended lamp.
The provided label must be applied to the retrotted luminaire where visible during re-lamping.
TURN POWER OFF AT BREAKER PANEL BEFORE WIRING.
Housing Compatibility
CDR6: 6”min - 6.7”max
CDR8: 7.7”min - 8.4”max
Remove existing lamp(s) and discard existing reector. (See Fig. 1)
Locate J-box of existing xture and remove cover.
Cut all input and output wires from ballast. (See Fig. 2)
Remove lamp base whip and exible metal conduit from existing J-Box.
Remove desired knockout from J-Box for driver power supply.
Place LED Driver box through ceiling cut-out and rest on ceiling.
Install Driver power supply into J-Box. (See Fig. 3)
a. Connect Black wire to live wire.
b. Connect White wire to neutral wire
c. Connect Green wire to ground wire
d. Route and connect purple and grey 0-10V dimming control wires
in accordance with dimmer instructions and electrical code.
NOTE: If 0-10V dimming is NOT to be connected, it is recommended
to cut o the exposed, tinned leads on the purple and grey
wires, and cover the ends with a small piece of electrical tape
or wire nut. If bare 0-10V control wires should accidentally
touch a grounded surface, it could cause unintended
ickering or dimming of the light xture.
Attach Safety Cable: Secure xture to structure per state and local codes.
Locate and loosen cable fastener.
Wrap cable around suitable anchor.
Guide end of cable into hole on top of fastener button.
Press fastener button to allow cable to pass through fastener.
Pull cable to tighten loop around frame. (See Fig. 4)
Plug orange connector from driver box into orange connector
on LED Lamp. (See Fig. 5)
Place lamp into existing frame. Ensure it is securely fastened.
Restore power after installation of xture is completed.
Attach provided lamping replacement marking label and cautionary label to light
xture where visible during re-lamping.
1
2
3
4
5
6
7
8
Fig. 1
Fig. 2
Fig. 3
Fig. 5
Fig. 4
CDR Commercial Downlight Retrot
INSTALLATION INSTRUCTIONS
Model(s): CDR6
CDR8