Bright Clean 20752-000 User manual

Type
User manual
IMPORTANT SAFETY INSTRUCTIONS
Read and Save:
1. Fixture can be used with an approved triac dimmer switch. Dimmable to 10% with recommended dimmers:
LUTRON-DVCL-153PR-WH.
2. Do not link together more than six units of fixtures on any single run.
3. To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions,
and other hazards read all warnings, instructions, and fixture labels.
4. Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
5. Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
6. For Residential installation: If you are unsure about the installation or maintenance of the luminaire, consult a qualified
licensed electrician and check your local electrical code.
7. DO NOT INSTALL DAMAGED PRODUCT!
8. SUITABLE FOR OPERATION IN AMBIENT TEMPERATURES NOT EXCEEDING 40°C.
9. These instructions do not purport to cover all details or variations in equipment nor provide every possible contingency
in connection with installation, operation, or maintenance.
10. Suitable for damp locations. For indoor use only.
11. Do not make or alter any open holes in an enclosure of wiring or electrical components during installation.
1
LIGHT BULB REPLACEMENT
WARRANTY
2. Turn off the unit and allow the bulb to cool before touching.
CLEANING AND MAINTENANCE
1. Clean using a mild cleaning solution and a soft cloth.
2. Never use a rough cloth or chemical cleaners containing acids, abrasives or solvents.
Model No.:20752-000, 20753-000, 20754-000, 20755-000
LED ANTIBACTERIAL UNDER CABINET
For Customer Assistance:
www.evolutionlightingllc.com
Made In China
1. Integrated LED bulb replacement not required.
3 YEAR LIMITED WARRANTY. Based on 3 hours of daily use.
2
SAFETY INFORMATION
For Customer Assistance:
www.evolutionlightingllc.com
Made In China
Please read and understand the entire manual before attempting to assemble, operate or
install the product.
WARNING
WARNING: RISK OF ELECTRICAL SHOCK
• Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
• Turn off the power when you perform any maintenance.
• Verify that supply voltage is correct by comparing it with the luminaire label information.
• Make all electrical and grounded connections in accordance with the National Electrical Code and
any applicable local code requirements.
• All wiring connections should be capped with UL approved wire connectors.
• Account for small parts and destroy packing material, as these may be hazardous to children.
ELECTRICAL CONNECTIONS (Required Supply Circuit: 120Vac, 60Hz)
CAUTION: RISK OF INJURY
• Allow fixture to cool before handling. Do not touch enclosure or light source.
• Do not exceed maximum wattage marked on luminaire label.
• Do not use 5’ power cord accessory when also direct-wiring the fixture! Use only one method to
power the fixture.
WARNING: RISK OF BURN
• Keep combustible and other materials that can burn away from luminaire and lamp/lens.
• Minimum 90° C supply conductors.
CAUTION: RISK OF FIRE
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
< Reorient or relocate the receiving antenna.
< Increase the separation between the lighting unit and receiver.
< Connect the lighting unit into an outlet on a circuit other than the outlet which the receiver is
connected.
< Consult the dealer or an experienced radio/TV technician for help.
NOTE: Please note that changes and modifcations not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
3
INSTALLATION (POWER-CORD METHOD)
For Customer Assistance:
www.evolutionlightingllc.com
Made In China
1. Remove fixture from the carton and check for any shipping
damage. Note: TURN OFF POWER AT CIRCUIT BREAKER BOX!
WIRING AND FIXTURE OPERATION CAUTION: Connect fixture
to supply wires rated for at least 90°C (194°F). Assistance may be
required to support fixture during installation.
2. Determine location of your first fixture. Make sure the mounting
location is within 5 feet of an electrical outlet.
3. Position the fixture housing against the mounting surface and
with a pencil, mark the screw hole locations to be located at the
narrow section of the keyholes (See Fig.1).
Fig.3
Fig.1
10. Plug in 5’ power cord to a grounded three-prong electrical
outlet (See Fig.5).
11. When all fixtures have been properly installed, ensure all of the
fixtures in the chain have been securely connected.
Part
Description
Qty
1
1
Direct-Wire Cavity Access Plate Screw
2
Direct-Wire Cavity Access Plate
1
3
Wire Terminals
3
4
Wire
3
5
Fixture Assembly
1
6
End-to-End Port Cover
2
7
Mounting Screws
2
8
End-to-End Row connector
1
9
Romex Bushing
1
10
13’’ Connector Cord
1
11
5’Power Cord
1
WARNING: RISK OF ELECTRICAL SHOCK
Do not use 5’ power cord accessory when also direct-
wiring the fixture! Use only one method to power the fixture.
9. After installation completed, place the End-to-End Port Cover
on the output port (See Fig.4).
12. Turn on power at the circuit breaker box and verify that fixture
functions properly. If fixture does not turn on, verify that the rocker
switch on each fixture is in the “on” position.
Fig.5
4. Using a drill with a 1/8" drill bit (not included), make two small
pilot holes at the marked locations. (Note: do not drill entirely
through mounting surface).
5. Partially install the provided mounting screws with a Phillips
screwdriver (not included).
6. Position the keyhole mounting holes over the screw heads and
slide the fixture until the screw heads are over the narrow section
of the keyholes. Finish tightening the screws to secure the fixture.
7. If using only one fixture skip to Step 9.
8. If connecting more fixtures, please repeat steps 3-6.
WARNING: Do not link together more than six units of fixtures on
any single run.
Note: The distance between fixtures cannot exceed the length of
the included 13" connector cord (See Fig.2) or end-to-end row
connector (See Fig.3).
To route your fixtures around a corner, simply install a fixture near
the corner and route the 13” connector cord around the corner
to connect the next fixture.
Fig.2
Fig.4
Fig.6
Fig.7
Fig.8
4
For Customer Assistance:
www.evolutionlightingllc.com
Made In China
1. Loosen the screw with a Phillips screw driver (not included).
(See Fig.6).
4. Loosen the screws and take down the backboard (See Fig.10).
5. Pull the wires with the wire terminals and connect with the input
cord from the conduit (see Fig.11). Insert the white supply wire
(neutral) into wire terminals with the preassembled white fixture
wire.Insert the black supply wire (hot) into wire terminals with the
preassembled black fixture wire. Insert supply ground wire into wire
terminals with the preassembled fixture ground wire.
12. Turn on power at the circuit breaker box and verify that fixture
functions properly. If fixture does not turn on, verify that the rocker
switch on each fixture is in the “on” position.
NOTEWhen install the hex nut, make sure the small step (A
side) facing the Cavity Access Plate , and the D part is parallel
with the plate, not vertical (see Fig.8). After the hex nut is
tightened, make sure its B side is parallel with the plate’s C side
(see Fig.9).
2. Remove Direct-Wire Cavity Access Plate . Determine
appropriate knockout for removal in relationship to incoming
Romex (power supply).
TO REMOVE KNOCKOUTS:
Place a standard screwdriver (not included) on edge of circle (on
opposite side from retaining tabs) and gently strike with hammer.
Grip edge with pliers and flex back and forth until removed (See
Fig. 7).
3. Push supply cable through the Romex Bushing . Strip black
and white wire leads with wire strippers to expose 3/8"-7/16" of
bare metal (See Fig.8). If wiring is being routed through the
knockout on the Direct-Wire Cavity Access Plate , install
Romex Bushing into the access plate (See Fig.8). Insert and
secure the supply cable by tighten the screws on Romex Bushing.
(See Fig.8). Secure the Direct-Wire Cavity Access Plate onto
the fixture assembly.
INSTALLATION (DIRECT-WIRE METHOD - CONVERTIBLE)
WARNING: RISK OF ELECTRICAL SHOCK
Do not use 5’ power cord accessory when also direct-wiring
the fixture! Use only one method to power the fixture.
6. Put the wires in order inside of the under cabinet, put on
backboard and screw up (See Fig.12).
7. Position the fixture housing against the mounting surface and
with a pencil, mark the screw hole locations to be located at the
narrow section of the keyholes (See Fig.1).
Fig.11
11. If using only one fixture skip to Step 12. If connecting more
fixtures, please follow steps 7-10. WARNING: Do not link
together more than six units of fixtures on any single run.
Note: The distance between fixtures cannot exceed the length of
the included 13" connector cord (See Fig.2) or end-to-end row
connector (See Fig.3).
To route your fixtures around a corner, simply install a fixture near
the corner and route the 13” connector cord around the corner
to connect the next fixture.
A
B
C
D
Fig.10
Fig.1
Fig.2
Fig.3
8. Using a drill with a 1/8" drill bit (not included), make two small
pilot holes at the marked locations. (Note: do not drill entirely
through mounting surface).
9. Partially install the provided mounting screws with a Phillips
screwdriver (not included).
10. Position the keyhole mounting holes over the screw heads and
slide the fixture until the screw heads are over the narrow section
of the keyholes. Finish tightening the screws to secure the fixture.
Fig.12
Fig.9
This product has been proven to reduce bacteria using key wavelengths that affect bacteria cells biologically. This product does NOT
emit ultra-violet light (UV). This product is NOT harmful to humans, animals, or plants.
To maximize the antibacterial effect, this product should be left on for several hours each day at full power. The longer the light is on,
the more effective it will be in reducing bacteria. This product is dimmable, but for maximum antibacterial effect, please use at full
power when operating to eliminate bacteria.
The product is intended for use in a kitchen setting, installed underneath cabinet shelves and above counter tops. The counter tops
are the target surface for eliminating bacteria. For best results, counter tops should be within 18 inches of the installed light fixture.
The fixture should be located centered over the counter to maximize direct light contact. This product will only impact bacteria that the
light directly reaches. Objects blocking the light or casting shadows will not allow for strong disinfection of the target surface.
This product is not intended to eliminate other forms of cleaning. When used in conjunction with good cleaning practices, this product
will more effectively reduce and eliminate bacteria.
This product is not for disinfecting food or liquids.
Staphylococcus aureus (incl. MRSA)
5
For Customer Assistance:
www.evolutionlightingllc.com
Made In China
APPLICATION GUIDE
What germs is Ellumi Effective Against?
Bacteria
Bacterial Endospores
Gram Positive
Bacillus cereus
Clostridium difficile
Yeast and Filamentous Fungi
Aspergillus niger
Candida albicans
Saccharomyces cerevisiae
Clostridium perfringens
Clostridium difficile
Enterococcus faecalis
Staphylococcus epidermidis
Staphyloccocus hyicus
Streptococcus pyogenes
Listeria monocytogenes
Bacillus cereus
Mycobacterium terrae
Lactococcus lactis
Lactobacillus plantarum
Bacillus circulans
Streptococcus thermophilus
Acinetobacter baumannii
Gram Negative
Pseudomonas aeruginosa
Klebsiella pneumoniae
Proteus vulgaris
Escherichia coli
Salmonella enteritidis
Shigella sonnei
Serratia spp.
Salmonella typhimurium
Consumer Service
Service d’aide aux Consommateurs
Servicio al Consumidor
http://www.evolutionlightingllc.com
LIMITED WARRANTY
EVOLUTION LIGHTING warrants all of its lighting fixtures against defects in materials and workmanship for one (1) year from the date of
original purchase. Electronic parts including passive infrared devices, photoelectric switching mechanisms, and light bulbs provided with
Evolution Lighting products are warranted for 30 days from the date of original purchase.
ENERGY STAR qualified product, which include GU24 Energy Star qualified bulbs, are warranted for repair or replacement of defective
parts of the luminaire
housing, mounting hardware, optics, ballast and trim for three (3) years from the date of purchase. GU24 based
integrated lamps included with the luminaire, carry a three (3) year warranty.
ENERGY STAR qualified Solid State product with replaceable components warrants the replaceable components for three (3) years.
ENERGY STAR qualified Solid State product with non replaceable components is warranted for five (5) years.
This warranty does not cover parts becoming defective due to misuse, accidental damage, improper handling and/o
r installation and
specifically excludes liability for indirect, incidental or consequential damages. Product found to be defective may or may not be replaced
with same or like type product, contingent on the nature of the defect, and or replacement availability and or compensated for at a pro
rated value. This warranty gives you specific rights and you may also have other rights, which vary from state to state. Proof of purchase is
required to exercise the warranty
.
GARANTÍA LIMITADA
EVOLUTION LIGHTING garantiza todas sus luminarias contra defectos de material y mano de obra por (1) año a contar de la fecha
original de compra. Las piezas electrónicas, lo que incluye dispositivos infrarrojos pasivos, mecanismos de conmutación fotoeléctrica, y
bombillas que vengan incluidas con el producto Evolution Lighting, están garantizadas por 30 días a contar de la fecha original de compra.
Los productos calificados por ENERGY STAR, lo que incluye bombillas GU24 calificadas por Energy Star, están garantizados por tres (3)
años a contar de la fecha de compra y s
erán repara dos o cambiados si la caja de la luminaria, el equipo de montaje, la óptica, el
balastro o las molduras tienen piezas defectuosas. Las bombillas integradas con base GU24 que vienen con la luminaria, están
garantizadas por tres (3) años.
Los repuestos para productos en estado sólido calificados por ENERGY STAR están garantizados por tres (3) años.
Los productos en estado sólido calificados por ENERGY STAR que no contengan repuestos están garantizados por cinco (5) años.
Esta garana no cub
re las piezas que tengan defectos debidos a su mal uso, a daños accidentales, y al manejo y/o la instalación
inapropiada de las mismas, y libera específicamente de toda responsabilidad por daños indirectos, casuales o consiguientes. Un
producto considerado defectuoso puede o no ser cambiado por otro producto idéntico o similar, dependiendo del tipo de defecto y/o a la
disponibilidad de un producto por el cual cambiarlo, y/o puede ser compensado a un valor prorrateado. Esta garana le da derechos
específicos además de los cuales puede tener otros, los cuales varían entre estados. S
e requiere un comprobante de compra para
cobrar la garana.
GARANTIE LIMITÉE
EVOLUTION LIGHTING garantit tous ses luminaires de tout faut en termes de matériel et de main-d’œuvre pendant un (1) an à
compter de la date d’achat d’origine. Les composants électroniques, incluant les éléments infrarouges passifs, les mécanismes
d’interrupteur photoélectriques et les ampoules fournies par les produits Evolution Lighting sont garantis 30 jours à compter de la date
d’achat d’origine.
Les produits homologués ENERGY STAR, incluant les ampoules GU24 homologuées Energy
Star, sont garantis pendant trois (3) ans à
compter de la date d'achat et seront réparés ou remplacés si le corps du luminaire, les pces de montage, l'optique, le contrepoids et
la bordure sont défectueux. Les lampes intégrées à culot GU24, qui viennent avec le luminaire, sont garanties pendant trois (3) ans.
Les produits à état solide homologués ENERGY STAR qui ont des composants remplaçables, ont leurs composants remplaçables
garantis pendant trois (3) ans.
Les produits à état solide homologués ENER
GY STAR qui ont des composants non remplaçables sont garantis pendant cinq (5) ans.
Cette garantie ne couvre pas les pièces qui deviennent fectueuses en raison d’une mauvaise utilisation ou manipulation, d’un accident
et/ou d’une installation incorrecte. Elle exclut scifiquement tout risque d’endommagement consécutif ou indirect. Un produit couvert
fectueux sera ou non remplacé par un produit identique ou similaire, selon la nature du faut et/ou la disponibilidu remplacement,
et/ou sera compen à une valeur au pro rata. Cette garantie vous donne des droits scif
iques, et vous pouvez également avoir
d’autres droits, qui varient selon les états. La preuve d’achat est exigée pour exercer le droit à la garantie.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Bright Clean 20752-000 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI