GE TM2010CCU2K Specification

  • Hello! I am an AI chatbot trained to assist you with the GE TM2010CCU2K Specification. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the main ampere rating of the GE TM2010CCU2K load center?
    How many 1-inch spaces does the GE TM2010CCU2K load center have?
    How many 1/2-inch spaces does the GE TM2010CCU2K load center have?
    What is the maximum wire size that can be used with the GE TM2010CCU2K load center?
    What is the minimum circuit breaker quantity that can be ordered for the GE TM2010CCU2K load center?
GE
Industrial Solutions
PowerMark Gold
*
Load Centers
100 - 200 Amp, 20/40 Circuit
Single Phase, Three Wire, 120/240 VAC, 22 kAIC Rated
• UL Listed (Panelboards No. 67)
• 60°C/75°C Conductor Rating
Suitable for use as Service Entrance Equipment when
installed in accordance with the National Electric Code
Technical Data
Main
Ampere
Rating
1 Pole 2 Pole 1 Pole 2 Pole
Total
1 Pole
Spaces
Main Style Catalog # Front Type Feed
Main Wire Size
(AWG/kcmil)
Cu-Al
Equipment
Ground Kit
Box
#
1" Spaces 1/2" Spaces
100 20 10 20 Main Breaker TM2010CCU
Combination
Flush/Surface
Top
Bottom
4-1/0 TGK24 (order separately) 6
200
18 10 40 18 40 Main Breaker
TM2020CCU
Combination
Flush/Surface
Top
Bottom
1-250 (Cu),
2/0-250 (Al)
TGK32 (order separately)
8
TM2020CCUW
White Combo
Flush/Surface
T G K 2 4 ( o r d e r s e p a r a t e l y )
TGK42 (order separately)
TM2020CCUG
Combination
Flush/Surface
TGK32 (order separately)
TM2020CCUGW
White Combo
Flush/Surface
TGK32 (order separately)
20 10 40 18 40
Main Breaker TM2020RCU Top
1-250 (Cu),
2/0-250 (Al)
T G K 2 4 ( o r d e r s e p a r a t e l y )
TGK42 (order separately)
R6
Main Lug /
Combination
TLM2020CCU
1
Combination
Flush/Surface
Top
Bottom
6-250
TGK32 (order separately)
8TLM2020CCUW
1,2
White Combo
Flush/Surface
TGK32 (order separately)
TLM2020CCUG
1
Combination
Flush/Surface
TGK42 (installed)
TLM2020RCU
1
Top 6-250
T G K 2 4 ( o r d e r s e p a r a t e l y )
TGK42 (order separately
R6A
1
For main breaker, order THQMVXXXD circuit breaker from BuyLog page 1-6.
2
Minimum order quantity is 40 for below 24 circuits; Minimum order quantity is 24 for 24 circuits and above. (See DEE-590).
GE
Industrial Solutions
41 Woodford Avenue
Plainville, CT 06062
www.geindustrial.com
Dimensions (inches)
Box Width Height Depth
6 14 23 3 3/4
8 14 26 7/16 3 3/4
R6 14 35 3/17 4 5/8
R6A 13 33 5
Breaker
Symbol
Breaker Fill
1" THQL 1/2" THQP
1
1 2
Terminal
Symbol
Wire Range (AWG/kcmil)
Cu Al
C
6-2/0 6-2/0
E
1-300 1-300
W
D
H
D
H
W
TM2010CCU, TM2010RCCU
TLM2020CCUTM2020CCU TM2020RCU TLM2020RCU
Box R6 and R6ABox 6 and 8
TM2020CCU, TM2020RCU,
TLM2020CCU, TLM2020RCU
© 2015 General Electric Company
* Indicates a trademark of the General Electric Company and/or its subsidiaries.
Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under
laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions.
DET-854 1115