DE 6 Kompressor-Kühlbox
Bedienungsanleitung
EN 24 Compressor Cooler
Instruction Manual
FR 41 Glacière à compression
Manuel d’utilisation
ES 59 Nevera por compresor
Instrucciones de uso
IT 77 Frigorifero a compressore
Istruzioni per l’uso
NL 96 Compressorkoelbox
Gebruiksaanwijzing
DA 113 Kompressor-køleboks
Betjeningsvejledning
SV 130 Kylbox med kompressor
Bruksanvisning
NO 147 Kjøleboks med kompressor
Bruksanvisning
FI 164 Kompressori-kylmälaatikko
Käyttöohje
PT 181 Geleira com compressor
Manual de instruções
RU 199 Компрессорный
холодильник
Инструкция по эксплуатации
PL 217 Lodówka kompresorowa
Instrukcja obsługi
CS 235 Kompresorový chladicí box
Návod k obsluze
SK 252 Chladiaci box s kompresorom
Návod na obsluhu
HU 269 Kompresszor hűtőláda
Használati utasítás
Fordern Sie weitere Informationen zur umfangreichen Produktpalette aus dem Hause
Dometic WAECO an. Bestellen Sie einfach unsere Kataloge kostenlos und unverbindlich
unter der Internetadresse: www.dometic-waeco.de
We will be happy to provide you with further information about Dometic WAECO products.
Please order our free catalogue with no obligation to buy on our homepage:
www.dometic-waeco.com
Demandez d’autres informations relatives à la large gamme de produits de la maison
Dometic WAECO. Commandez tout simplement notre catalogue gratuitement et sans
engagement à l’adresse internet suivante : www.dometic-waeco.com
Solicite más información sobre la amplia gama de productos de la empresa Dometic
WAECO. Solicite simplemente nuestros catálogos de forma gratuita y sin compromiso en
la dirección de Internet: www.dometic-waeco.com
Per ottenere maggiori informazioni sull’ampia gamma di prodotti Dometic WAECO è
possibile ordinare una copia gratuita e non vincolante del nostro Catalogo all’indirizzo
Internet: www.dometic-waeco.com
Maak kennis met het omvangrijke productscala van de firma Dometic WAECO. Bestel onze
catalogus gratis en vrijblijvend onder het internetadres: www.dometic-waeco.com
Bestil yderligere information om det omfattende produktudvalg fra Dometic WAECO.
Bestil vores katalog gratis og uforpligtende på internetadressen: www.dometic-waeco.com
Inhämta mer information om den omfattande produktpaletten från Dometic WAECO:
Beställ våra kataloger gratis och utan förpliktelser under vår Internetadress:
www.dometic-waeco.com
Be om mer informasjon om det rikholdige produktutvalget fra Dometic WAECO. Bestill vår
katalog gratis uforbindtlig på Internettadressen: www.dometic-waeco.com
Pyytäkää lisää tietoja Dometic WAECOn kattavista tuotevalikoimista. Tilatkaa
tuotekuvastomme maksutta ja sitoumuksetta internet-osoitteesta:
www.dometic-waeco.com
Peça mais informação sobre a ampla gama de produtos da empresa Dometic WAECO.
Peça simplesmente os nossos catálogos de forma gratuita e sem qualquer compromisso,
disponível no site: www.dometic-waeco.com
Запросите дальнейшую информацию об обширном ассортименте продукции
компании Dometic WAECO. Просто закажите наши каталоги на сайте
www.dometic-waeco.com; эта услуга предоставляется бесплатно и ни к чему не
обязывает.
Proszę si
ę zapoznać z informacjami na temat szerokiej gamy produktów Dometic WAECO.
Proszę zamówić nasz bezpłatny katalog i zapoznać się zniewiążącą ofertą pod adresem:
www.dometic-waeco.com
Žádejte další informace o rozsáhlé nabídce výrobků firmy Dometic WAECO. Stačí zdarma
a nezávazně objednat naše katalogy na internetové adrese: www.dometic-waeco.com
Vyžiadajte si ďalšie informácie o rozsiahlej palete výrobkov Dometic WAECO. Objednajte
si bezplatne a nezáväzne náš katalóg na internetovej adrese: www.dometic-waeco.com
Kérjen további információkat a Dometic WAECO cég széles körű termékpalettájáról.
Rendelje meg ingyenes katalógusainkat kötelezettség nélkül a következő internetcímen:
www.dometic-waeco.de
DE
EN
FR
ES
IT
NL
DA
SV
NO
FI
PT
RU
PL
CS
SK
HU
CoolFreeze
3
1
2
1
2
CDF18
12/24V DC
COLD FREEZE
ERROR
POWER
HIGH
0
LOW
TEMPERATURE BATTERY MONITOR
1 2 3 4
5
ERROR
POWER
°
1
34
5 6 7
2
3
CDF26
EN
Explanation of symbols CoolFreeze
24
Please read this operating manual carefully before starting the device.
Keep it in a safe place for future reference. If the device is passed on to
another person, this operating manual must be handed over to the user
along with it.
The manufacturer cannot be held liable for damage resulting from
improper usage or incorrect operation.
Contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5 Function description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7 Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
8 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
10 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
11 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
1 Explanation of symbols
D
!
DANGER!
Safety instruction: Failure to observe this instruction will cause
fatal or serious injury.
WARNING!
Safety instruction: Failure to observe this instruction can cause
fatal or serious injury.
EN
CoolFreeze Safety instructions
25
!
A
I
Action: This symbol indicates that action is required on your part. The
required action is described step-by-step.
This symbol describes the result of an action.
Fig. 1 5, page 3: This refers to an element in an illustration. In this case,
item 5 in figure 1 on page 3.
2 Safety instructions
2.1 General safety
!
WARNING!
Do not operate the device if it is visibly damaged.
If this device's power cable is damaged, it must be replaced by
the manufacturer, customer service or a similarly qualified
person in order to prevent safety hazards.
This device may only be repaired by qualified personnel.
Improper repairs can lead to considerable hazards.
This device can be used by children aged 8 years or over, as
well as by persons with diminished physical, sensory or mental
capacities or a lack of experience and/or knowledge, providing
they are supervised or have been taught how to use the device
safely and are aware of the resulting risks.
Cleaning and user maintenance must not be carried out by
children without supervision.
Children must not play with the device.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to
injury.
NOTICE!
Failure to observe this instruction can cause material damage and
impair the function of the product.
NOTE
Supplementary information for operating the product.
EN
Safety instructions CoolFreeze
26
Children must be supervised to ensure that they do not play with
the device.
Always keep and use the device out of the reach of children
under the age of 8 years.
Do not store any explosive substances such as spray cans with
a flammable propellant in the device.
!
CAUTION!
Disconnect the device from the mains
before each cleaning and maintenance
after every use
Food may only be stored in its original packaging or in suitable
containers.
A
NOTICE!
Check that the voltage specification on the type plate
corresponds to that of the energy supply.
Only connect the device to a DC plug socket in the vehicle (e. g.
cigarette lighter) with the DC cable.
Never pull the plug out of the socket by the cable.
Disconnect the cooler and other power consuming devices from
the battery before connecting the quick charging device.
Disconnect the cooler or switch it off when you turn off the
engine. Otherwise you may discharge the battery.
The cooling device is not suitable for transporting caustic
materials or materials containing solvents.
2.2 Operating the device safely
D
DANGER!
Do not touch exposed cables with your bare hands.
!
CAUTION!
Before starting the device, ensure that the power supply line
and the plug are dry.
A
NOTICE!
Do not use electrical devices inside the cooler unless they are
recommended by the manufacturer for the purpose.
EN
CoolFreeze Scope of delivery
27
Do not place the device near naked flames or other heat
sources (heaters, direct sunlight, gas ovens etc.).
Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the
heat that arises during operation does not build up. Make sure
that the device is sufficiently far away from walls and other
objects so that the air can circulate.
Ensure that the ventilation openings are not covered.
Do not fill the inner container with ice or fluid.
Never immerse the device in water.
Protect the device and the cable against heat and moisture.
3 Scope of delivery
fig. 1, page 3, shows the scope of delivery.
3.1 Accessories
To operate the device at the AC mains supply, we recommend using one of
the following WAECO rectifiers.
Available as accessory (not included in scope of delivery):
220240 V: CoolPower EPS100
110240 V: CoolPower MPS35
Item Quantity Description
11Cooler
2 1 Connection cable for 12/24 Vg connection
1 Operating manual
EN
Intended use CoolFreeze
28
4 Intended use
The cooler is suitable for cooling and freezing foods. The device is
also suitable for use on boats.
The device is designed to be operated from a 12 Vg or 24 Vg on-
board supply socket of a vehicle (e. g. cigarette lighter), boat or
caravan.
I
!
5 Function description
The cooler can chill products, keep them cool as well as freeze them. A main-
tenance-free, CFC-free refrigerant circuit with compressor provides the cool-
ing. The extra strong CFC-free insulation and powerful compressor ensure
especially fast cooling.
The cooler is designed for mobile use.
When used on boats, the cooler can be withstand a constant heel (inclina-
tion) of 30°.
An integrated dual-stage (CDF18) / three-stage (CDF26, CDF36,
CDF46) battery monitor prevents your vehicle battery from exces-
sive discharging.
NOTE
To operate the device at the AC mains supply, we recommend
using one of the following WAECO rectifiers:
220240 V: CoolPower EPS100
110240 V: CoolPower MPS35
CAUTION! Health hazard!
Please check if the cooling capacity of the device is suitable for
storing the food or medicine you wish to cool.
EN
CoolFreeze Function description
29
5.1 Operating and display elements
CDF18
Operating panel and connection socket (fig. 2, page 3):
Item Description Explanation
1 TEMPERATURE Temperature controller,
cooling temperature at the end positions:
COLD: +10 °C
FREEZE: –18 °C
2 POWER Operating display
LED is lit green: Device is switched on and
ready for operation
LED is lit yellow: Set temperature has been
reached
3 ERROR LED flashes red: Switched on device is not
ready for operation
4 BATTERY
MONITOR
Switch-on device/battery monitor:
0: Device is switched off
HIGH: Device is switched on, bat-
tery monitor is in HIGH
mode
LOW: Device is switched on, bat-
tery monitor is in LOW
mode
5 12/24V DC Connection socket DC voltage supply
EN
Function description CoolFreeze
30
CDF26
Operating panel and connection socket (fig. 3, page 3, fig. 5, page 4):
Item Description Explanation
1ON
OFF button
Switches the cooler on or off when the button is
pressed for between one and two seconds
2 POWER Status indication
LED lights up green: Compressor is on
LED lights up orange: Compressor is off
LED flashes orange: Display switched off auto-
matically due to low battery
voltage
3 ERROR LED flashes red: Device is switched on but
not ready for operation
4 SET Selects the input mode
– Temperature setting
– Celsius or Fahrenheit display
– Set battery monitor
5 Display, shows the information
The first three digits of the four-digit display show the
temperature, the fourth digit shows the temperature
unit (°C or °F).
6 UP + Press once to increase the value
7 DOWN – Press once to decrease the value
EN
CoolFreeze Operation
31
CDF36, CDF46
Operating panel and connection socket (fig. 3, page 3, fig. 5, page 4):
6 Operation
6.1 Before initial use
I
Item Description Explanation
1ON
OFF button
Switches the cooler on or off when the button is
pressed for between one and two seconds
2 POWER Status indication
LED lights up green: Compressor is on
LED lights up orange: Compressor is off
LED flashes orange: Display switched off auto-
matically due to low battery
voltage
3 ERROR LED flashes red: Device is switched on but
not ready for operation
4 SET Selects the input mode
– Temperature setting
– Celsius or Fahrenheit display
– Set battery monitor
5 Display, shows the information
The first three digits of the four-digit display show the
temperature, the fourth digit shows the temperature
unit (°C or °F).
6 ADJUST Press once to increase the value
Press once to decrease the value
NOTE
Before starting your new cooler for the first time, you should clean
it inside and outside with a damp cloth for hygienic reasons
(please also refer to the chapter “Cleaning and maintenance” on
page 38).
EN
Operation CoolFreeze
32
6.2 Energy saving tips
Choose a well ventilated installation location which is protected against
direct sunlight.
Allow warm food to cool down first before placing it in the device to keep
cool.
Do not open the cooling device more often than necessary.
Do not leave the cooler unit open for longer than necessary.
Defrost the cooler once a layer of ice forms.
Avoid unnecessary low temperatures.
6.3 Connecting the cooler
The cooler can be operated with 12 V or 24 V DC.
A
For safety reasons the cooler is equipped with an electronic system to pre-
vent the polarity reversal. This protects the cooler against short-circuiting
when connecting to a battery.
Plug the 12/24-V connection cable (fig. 1 2, page 3) into the DC voltage
socket and also into the cigarette lighter or a 12 V or 24 V socket.
6.4 Using the battery monitor
If the cooler is operated when the vehicle ignition is switched off, the cooler
switches off automatically as soon as the supply voltage falls below a set
level. The cooler will switch back on once the battery has been recharged to
the restart voltage level.
A
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW”
and “MED” (see the following table).
NOTICE! Danger of damaging the device!
Disconnect the cooler and other consumer units from the battery
before you connect the battery to a quick charging device.
Overvoltage can damage the electronics of the device.
NOTICE! Danger of damage!
When switched off by the battery monitor, the battery will no
longer be fully charged. Avoid starting repeatedly or operating
current consumers without longer charging phases. Ensure that
the battery is recharged.
EN
CoolFreeze Operation
33
CDF18:
CDF26, CDF36, CDF46:
I
CDF26: Setting the battery monitor mode
This is how to select the battery monitor mode:
Switch on the cooler.
Press the “SET” button three times.
Use the “+” and “–” buttons to select the battery monitor mode.
The selected mode then appears in the display for a few seconds. The
display flashes several times before it returns to the current temperature.
Battery monitor mode LOW HIGH
Switch-off voltage at 12 V
10,2 V ± 0,3 V 11,2 V ± 0,3 V
Restart voltage at 12 V
11,2 V ± 0,3 V 12,2 V ± 0,3 V
Switch-off voltage at 24 V
22,0 V ± 0,3 V 23,9 V ± 0,3 V
Restart voltage at 24 V
23,3 V ± 0,3 V 25,1 V ± 0,3 V
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V
10,1 V 11,4 V 11,8 V
Restart voltage at 12 V
11,1 V 12,2 V 12,6 V
Switch-off voltage at 24 V
21,5 V 24,1 V 24,6 V
Restart voltage at 24 V
23,0 V 25,3 V 26,2 V
NOTE
When the cooler is supplied by the starter battery, select the bat-
tery monitor mode “HIGH”. If the cooler is connected to a supply
battery, the battery monitor mode “LOW” will suffice.
If you wish to operate the cooler from the AC mains, set the bat-
tery monitor to the “LOW” position.
EN
Operation CoolFreeze
34
CDF36, CDF46: Setting the battery monitor mode
This is how to select the battery monitor mode:
Switch on the cooler.
Press the “SET” button three times.
Use the “ADJUST” button to select the battery monitor mode.
6.5 Using the cooler
A
Place the cooler on a firm foundation.
Make sure that the ventilation slots are not covered and that the heated
air can dissipate.
Close the cooler, see chapter “Connecting the cooler” on page 32.
A
Locking the cooler
Close the lid.
Press the lock (fig. 6 1, page 4) down, until it latches in place audibly.
CDF18: Switching on the cooler
Slide the sliding switch “BATTERY MONITOR” to HIGH if you wish to
operate from a starter battery or to “LOW” if you want to operate from a
supply battery.
I
The “POWER” LED is lit green.
NOTICE! Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the
heat that generated during operation can dissipate. Ensure that
the ventilation slots are not covered. Make sure that the device
is sufficiently far away from walls and other objects so that the
air can circulate.
NOTICE! Danger from excessively low temperature!
Ensure that the only those objects are placed in the cooler that are
intended to be cooled at the selected temperature.
NOTE
If you wish to operate the cooler from the AC mains, set the bat-
tery monitor to the “LOW” position.
EN
CoolFreeze Operation
35
The cooler starts cooling the interior.
Set the cooling temperature with the temperature controller “TEMPERA-
TURE”.
When the cooling temperature has been reached, the “POWER” LED is
lit yellow.
CDF26, CDF36, CDF46: Switching on the cooler
Press the “ON/OFF” button for three seconds.
The “POWER” LED is lit green.
The display switches on and shows the current cooling temperature.
The cooler starts cooling the interior.
I
CDF18: Switching off the cooler
Empty the cooler.
To Switch the cooler off: Slide the sliding switch “BATTERY MONITOR
to “0”:
Pull out the connection cable.
If you do not want to use the cooler for a longer period of time:
Leave the cover slightly open. This prevents odour build-up.
CDF26, CDF36, CDF46: Switching off the cooler
Empty the cooler.
Switch the cooler off.
Unplug the connection cable.
If you do not want to use the cooler for a longer period of time:
Leave the lid slightly open. This prevents build-up of odours.
NOTE
If you wish to operate the cooler from the AC mains, set the bat-
tery monitor to the “LOW” position.
EN
Operation CoolFreeze
36
6.6 Setting the temperature
CDF26:
Press the “SET” button once.
Use the “+” and “–” buttons to set the cooling temperature.
The set cooling temperature then appears in the display for a few sec-
onds. The display flashes several times before it returns to the current
temperature.
CDF36, CDF46:
Press the “SET” button once.
Use the “ADJUST” button to set the cooling temperature.
The set cooling temperature then appears in the display for a few seconds.
The display flashes several times before it returns to the current temperature.
6.7 Selecting the temperature unit
CDF26:
You can switch the temperature display between Celsius and Fahrenheit. To
do this, proceed as follows:
Switch on the cooler.
Press the “SET” button twice.
Use the “+” and “–” buttons to set the cooling temperature.
The set temperature unit then appears in the display for a few seconds.
The display flashes several times before it returns to the current temper-
ature.
CDF36, CDF46:
You can switch the temperature display between Celsius and Fahrenheit. To
do this, proceed as follows:
Switch on the cooler.
Press the “SET” button twice.
Use the “ADJUST” button to set the Celsius or Fahrenheit temperature
unit.
EN
CoolFreeze Operation
37
6.8 Defrosting the cooler
Humidity can form frost in the interior of the cooling device or on the vapor-
iser. This reduces the cooling capacity. Defrost the device in good time to
avoid this.
A
To defrost the cooler, proceed as follows:
Take out the contents of the cooling device.
If necessary, place them in another cooling device to keep them cool.
Switch off the device.
Leave the cover open.
Wipe off the defrosted water.
6.9 Replacing the plug fuse (12/24 V)
Pull the adapter sleeve (fig. 7 4, page 4) off of the plug.
Unscrew the screw (fig. 7 5, page 4) out of the upper half of the housing
(fig. 7 1, page 4).
Carefully raise the upper half of the housing from the lower (fig. 7 6,
page 4) half.
Take out the contact pin (fig. 7 3, page 4).
Replace the defective fuse (fig. 7 2, page 4) with a new one that has the
same rating (8A 32V).
Re-assemble the plug in the reverse order.
6.10 Replacing the light bulb (CDF26, CDF36, CDF46)
Press the switch pin (fig. 8 2, page 5) downwards so that the transpar-
ent part (fig. 8 1, page 5) of the lamp can be removed at the front.
Replace the light bulb.
Press the lamp back into the housing.
NOTICE! Danger of damaging the device!
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
EN
Cleaning and maintenance CoolFreeze
38
7 Cleaning and maintenance
!
A
Occasionally clean the device interior and exterior with a damp cloth.
Make sure that the air inlet and outlet vents on the device are free of any
dust and dirt, so that heat can be released and the device is not damaged.
8 Guarantee
The statutory warranty period applies. If the product is defective, please
contact the manufacturer's branch in your country (see the back of the
instruction manual for the addresses) or your retailer.
For repair and guarantee processing, please include the following docu-
ments when you send in the device:
A copy of the receipt with purchasing date
A reason for the claim or description of the fault
WARNING!
Always disconnect the device from the mains before you clean
and service it.
NOTICE! Risk of damage
Never clean the cooler under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during
cleaning as these can damage the cooler.
EN
CoolFreeze Troubleshooting
39
9 Troubleshooting
10 Disposal
Place the packaging material in the appropriate recycling waste bins
wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
Fault Possible cause Suggested remedy
Device does not
function, LED does
not glow.
There is no voltage
present in the 12/24 V
socket (cigarette lighter)
in your vehicle.
The ignition must be switched on in most
vehicles to apply current to the cigarette
lighter.
No voltage present in
the AC voltage socket.
Try using another plug socket.
The device does not
cool (plug is inserted,
“POWER” LED is lit).
Defective compressor. This can only be repaired by an
authorised customer services unit.
The device does not
cool (plug is inserted,
“ERROR” LED
flashes).
Battery voltage is too
low.
Test the battery and charge it as needed.
When operating from
the 12/24-V socket
(cigarette lighter):
The ignition is on
and the device is not
working and the LED
is not lit.
Pull the plug out of the
socket and make the
following checks.
The cigarette lighter
socket is dirty. This
results in a poor electrical
contact.
If the plug of your cooler becomes very
warm in the cigarette lighter socket,
either the lighter socket must be cleaned
or the plug has not been assembled
correctly.
The fuse of the 12/24 V
plug has blown.
Replace the fuse (5 A) in the cigarette
lighter plug, see chapter “Replacing the
plug fuse (12/24 V)” on page 37.
The vehicle fuse has
blown.
Replace the vehicle’s 12/24 V socket fuse
(usually 15 A). Please refer to your
vehicle’s operating manual.
“ERROR” LED flashes
for longer than
2 minutes, as follows:
3 flashes, pause,
3 flashes, pause, ...
Device is defective. This can only be repaired by an author-
ised customer services unit.
EN
Technical data CoolFreeze
40
11 Technical data
I
The coolant circuit contains R134a.
WAECO CoolFreeze
CDF18 CDF26 CDF36 CDF46
Art.-Nr.: 9105100002 9105303457 9105303458 9105303459
Overall
capacity:
18 l 21 l 31 l 39 l
Connection
voltage:
12/24 Vg
Rated cur-
rent:
– 12 Vg: 4.0 A ± 0.5 5.0 A ± 0.5 5.0 A ± 0.5 5.0 A ± 0.5
– 24 Vg: 1.7 A ± 0.5 2.5 A ± 0.5 2.5 A ± 0.5 2.5 A ± 0.5
Cooling
capacity:
+1C to1C +1C to1C
Dimen-
sions
(W x H x D)
in mm:
456 x 414 x 300 550 x 425 x 260 560 x 380 x 340 560 x 475 x 340
Weight: 11.5 kg 12.7 kg 12.4 kg 13.7 kg
Test/certifi-
cates:
NOTE
At ambient temperatures above 32 °C (90 °F) the minimum tem-
perature cannot be achieved.
E4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288

Dometic CoolFreeze CDF18, CDF26, CDF36, CDF46 User manual

Category
Cool boxes
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI