Generac 005939-0 Owner's manual

Category
Power generators
Type
Owner's manual

This manual is also suitable for

G ®
-
r|Owne s IVlanual
GPSeriesPortableGefl
br
introduction.............................................................1
ReadthisiVlanualThoroughly.................................1
Safety Rules...........................................................1
StandardsIndex.............................................................3
Generalinformation................................................4
1.1 Unpacking......................................................................4
1.1.1 Accessory Box..................................................4
1.2 Assembly.......................................................................4
1.2.1 Assemblingthe AccessoryKit............................4
1.2.2 StarterConnection(ElectricStart Only)..............4
Operation................................................................4
2.1 Knowthe Generator.......................................................4
2.2 Hourmeter......................................................................5
2.3 CordSets andConnectionPlugs....................................6
2.3.1 120 VAC,20 Amp, DuplexReceptacle...............6
2.3.2 120/240VAC,30 Amp, Receptacle....................6
2.4 Howto Usethe Generator..............................................6
2.4.1 Groundingthe Generator....................................6
2.4.2 ConnectingElectricalLoads...............................7
2.5 Don'tOverloadthe Generator..........................................7
2.6 WattageReferenceGuide...............................................7
2.7 BeforeStartingtheGenerator.........................................8
2.7.1 Adding EngineOil..............................................8
2.7.2 Adding Gasoline.................................................8
2.8 Starting Pull Start Engines..............................................8
2.9 Starting ElectricStart Engines........................................9
2.10 Stoppingthe Engine.....................................................10
2.11 LowOil LevelShutdownSystem..................................10
2.11.1 SensingLowOil Level......................................10
2.12 Chargingthe Battery(ElectricStart UnitsOnly).............10
Maintenance.........................................................10
3.1 MaintenanceSchedule.................................................10
3.2 ProductSpecifications..................................................10
3.2.1 GeneratorSpecifications..................................10
3.2.2 EngineSpecifications.......................................11
3.2.3 EmissionsInformation.....................................11
3.3 GeneralRecommendations...........................................11
3.3.1 GeneratorMaintenance....................................11
3.3.2 ToCleanthe Generator.....................................11
3.3.3 EngineMaintenance.........................................11
3.3.4 CheckingOil Level...........................................11
3.3.5 Changingthe Oil..............................................11
3.3.6 Replacingthe SparkPlug.................................12
3.3.7 BatteryReplacement........................................12
3.4 ServiceAir Filter...........................................................12
3.5 ValveClearance............................................................13
3.6 General........................................................................13
3.7 Long TermStorage.......................................................13
3.8 OtherStorageTips.......................................................13
Troubleshooting....................................................14
4.1 TroubleshootingGuide..................................................14
Notes....................................................................15
Warranty...............................................................16
Manualdel propietario.............................19
Manueld'entretien....................................39
iNTRODUCTiON
Thankyou for purchasingthis modelby GeneracPowerSystems,
Inc. This model is a compact, high performance, air-cooled,
engine driven generatordesigned to supply electrical power to
operateelectrical loads where no utility power is availableor in
placeof utility dueto a poweroutage.
BEADTHiSMANUALTHOROUGHLY
If any portion of this manual is not understood, contact the
nearest Authorized Dealerfor starting, operating and servicing
procedures.
The operator is responsiblefor proper and safe use of the
equipment.We strongly recommendthat the operator read this
manualandthoroughlyunderstandall instructionsbeforeusingthe
equipment.Wealsostronglyrecommendinstructingotherusersto
properlystart andoperatethe unit.This preparesthem ifthey need
to operatetheequipmentin an emergency.
Thegeneratorcan operatesafely,efficiently and reliablyonly if it
is properlylocated,operatedand maintained.Beforeoperatingor
servicingthe generator:
Becomefamiliar with and strictly adhereto all local, stateand
nationalcodes and regulations.
Study all safety warnings in this manual and on the product
carefully.
Becomefamiliar with this manualandthe unit beforeuse.
Themanufacturercannot anticipateevery possible circumstance
that might involvea hazard.Thewarnings in this manual,and on
tags and decals affixedto the unit are,therefore,not all inclusive.
If usinga procedure,work method or operatingtechniquethat the
manufacturerdoes not specifically recommend,ensurethat it is
safe for others. Also make sure the procedure,work method or
operatingtechnique utilizeddoes not renderthe generatorunsafe.
THE INFORMATIONCONTAINEDHEREIN WAS BASED ON
MACHINESIN PRODUCTIONAT THE TIME OF PUBLICATION.
GENERACRESERVESTHERIGHTTOMODIFYTHISMANUALAT
ANYTIME.
SAFETYRULES
Throughoutthis publication,and on tags and decals affixedto the
generator,DANGER,WARNING,CAUTIONand NOTEblocks are
usedto alert personnelto special instructionsabout a particular
operation that may be hazardous if performed incorrectly or
carelessly.Observethem carefully.Theirdefinitionsareasfollows:
INDICATES A HAZARDOUS SITUATION OR ACTION
WHICH, iF NOT AVOIDED, WILL RESULT iN DEATH
OR SERIOUS INJURY.
Indicates a hazardous situation or action which, if
not avoided, could result in death or serious injury.
,ACAUTION!
Indicates a hazardous situation or action which,
if not avoided, could result in minor or moderate
injury.
NOTE:
Notes containadditional informationimportantto a procedure
and will be found withinthe regulartextbody of thismanual.
These safety warnings cannot eliminate the hazards that they
indicate. Common sense and strict compliancewith the special
instructionswhileperforming theaction or serviceareessentialto
preventingaccidents.
Four commonly used safety symbols accompany the BANGER,
WARNINGand CAUTIONblocks. The type of information each
indicatesis asfollows:
,_This symbol points out important safety
information that, if not followed, could
endanger personal safety and/or property of
others.
This symbol points out potential explosion
hazard.
//_This symbol points out potential fire hazard.
This symbol points out potential electrical
shock hazard.
GENERAL HAZARDS
NEVERoperatein an enclosed area, in a vehicle, or indoors
EVENIFdoorsand windows areopen.
For safety reasons, the manufacturer recommends that the
maintenanceof this equipmentis carried out by an Authorized
Dealer.Inspectthe generatorregularly,and contactthe nearest
AuthorizedDealerfor parts needingrepairor replacement.
Operategeneratoronly on levelsurfacesandwhereit will notbe
exposedto excessivemoisture,dirt, dust or corrosivevapors.
Keep hands, feet, clothing, etc., away from drive belts, fans,
and othermoving parts. Neverremoveany fan guardor shield
whilethe unit isoperating.
Certain parts of the generator get extremely hot during
operation. Keep clear of the generator until it has cooled to
avoidsevereburns.
Do NOToperategeneratorinthe rain.
Do not alter the construction of the generator or change
controlswhich might createan unsafeoperatingcondition.
Never start or stop the unit with electrical loads connected
to receptaclesAND with connecteddevicesturned ON. Start
the engine and let it stabilize before connecting electrical
loads. Disconnectall electricalloads beforeshutting downthe
generator.
Do notinsert objectsthrough unit's cooling slots.
When working on this equipment, remain alert at all times.
Never work on the equipment when physically or mentally
fatigued.
Neverusethegeneratororanyofitspartsasastep.Stepping
ontheunitcanstressandbreakparts,andmayresultin
dangerousoperatingconditionsfromleakingexhaustgases,
fuelleakage,oilleakage,etc.
Onelectricstartmodels,disconnectthePOSITIVE(+)battery
cablefromtheenginestarterORtheNEGATIVE(-)battery
cablefromthebatteryterminal,whicheveriseasier,before
transportingthegenerator.
EXHAUST& LOCATIONHAZARDS
Never operate in an enclosed area or indoors!NEVERuse
in the home, in a vehicle,or in partlyenclosed areassuch
as garages,evenif doors and windowsare open! ONLYuse
outdoors and far from openwindows,doors, vents,andinan
areathatwill notaccumulatedeadly exhaust.
Using a generator indoors CAN KILL YOU IN MINUTES,
Generator exhaust contains carbon monoxide. This is
a poison you cannot see or smell,
NEVER use insidea home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents=
The engine exhaustfumes contain carbon monoxide, which
you cannot see or smell. This poisonous gas, if breathedin
sufficientconcentrations,can causeunconsciousnessor even
death.
Adequate, unobstructed flow of cooling and ventilating air
is critical to correct generator operation. Do not alter the
installation or permit even partial blockage of ventilation
provisions, as this can seriously affect safe operationof the
generator.ThegeneratorMUSTbeoperatedoutdoors.
This exhaustsystemmust be properlymaintained.Do nothing
that mightrendertheexhaustsystemunsafeorinnoncompliance
with any localcodes and/orstandards.
Alwaysusea batteryoperatedcarbonmonoxidealarmindoors,
installedaccordingto themanufacturersinstructions.
If you start to feet sick, dizzy,or weak after the generatorhas
beenrunning,moveto fresh air IMMEDIATELYSeea doctor,as
you couldhavecarbonmonoxidepoisoning.
ELECTRICALHAZARDS
The generator produces dangerously high voltage when in
operation.Avoidcontactwith barewires,terminals,connections,
etc., while the unit is running,even on equipmentconnected
to the generator. Ensureall appropriate covers, guards and
barriersarein placebeforeoperatingthegenerator.
Never handle any kind of electrical cord or device while
standinginwater,while barefootorwhile handsor feet arewet.
DANGEROUSELECTRICALSHOCKMAYRESULT.
TheNationalElectricCode(NEC)requirestheframeandexternal
electrically conductive parts of the generator be properly
connectedto an approvedearthground.Local electricalcodes
may also require proper grounding of the generator.Consult
with a localelectricianfor groundingrequirementsin thearea.
Use a ground fault circuit interrupter in any damp or highly
conductivearea(such as metaldecking or steelwork).
Do not useworn, bare,frayed or otherwisedamagedelectrical
cord setswith the generator.
Beforeperforminganymaintenanceonthegenerator,disconnect
the enginestarting battery (if equipped)to prevent accidental
start up. Disconnectthe cablefrom the batterypost indicated
by a NEGATIVE,NEGor (-) first. Reconnectthatcable last.
In caseof accidentcausedby electricshock, immediatelyshut
down the source of electrical power. If this is not possible,
attempt to free the victim from the live conductor. AVOID
DIRECTCONTACTWITH THEVICTIM, Use a non-conducting
implement,such asa rope or board,to freethevictim from the
live conductor.If the victim is unconscious,applyfirst aid and
getimmediatemedical help.
FIREHAZARDS
GasolineishighlyFLAMMABLEanditsvaporsare EXPLOSIVE.
Do not permitsmoking,open flames, sparksor heat in the
vicinitywhilehandling gasoline.
Neveraddfuel whileunit isrunning or hot. Allow engineto cool
completelybeforeaddingfuel.
Never fill fuel tank indoors.Comply with all laws regulating
storageand handlingof gasoline.
Do not overfill the fuel tank. Always allow roomfor fuel
expansion.If tank is over=filled,fuel can overflow onto a hot
engineandcauseFIREor an EXPLOSION.Neverstoregenerator
with fuel in tank where gasolinevapors might reachan open
flame, spark or pilot light (as on a furnace, water heateror
clothes dryer). FIREor EXPLOSIONmay result. Allow unit to
cool entirelybeforestorage.
Wipe up any fuel or oil spills immediately.Ensure that no
combustiblematerialsareleft on or nearthegenerator.Keepthe
areasurroundingthe generatorcleanandfree from debrisand
keepa clearanceof five (5) feet on all side to allow for proper
ventilationofthe generator.
* Do notinsert objectsthrough unit's cooling slots.
* Do not operatethe generatorif connected electrical devices
overheat,if electricaloutputislost, if engineor generatorsparks
or ifflames or smokeare observedwhileunit is running.
* Keepafire extinguishernearthe generatoratall times.
STANDARDS/#DEX
Intheabsenceof pertinentstandards,codes,regulationsandtaws,
the publishedinformationlistedbelowmay be usedas aguideline
foroperationofthis equipment.Alwaysreferencethelatestrevision
availablefor the standardslisted.
1. NFPANo. 70, NFPAHANDBOOKOF NATIONALELECTRIC
CODE.
2. Article X, NATIONALBUILDINGCODE,available from the
American InsuranceAssociation, 85 John Street, New York,
N.Y 10038.
3. AGRICULTURALWIRINGHANDBOOK,availablefrom the Food
and EnergyCouncil, 909 UniversityAvenue, Columbia, MO
65201.
4. ASAE EP-3634, INSTALLATIONAND MAINTENANCEOF
FARMSTANDBYELECTRICALSYSTEMS,availablefrom the
AmericanSocietyof AgriculturalEngineers,2950 NilesRoad,
St. Joseph,MI 49085.
MODELNO:
SERIALNO:
Unit ID Location
DATA
DECAL
CALIFORNIAPROPOSITION65 WARNING
Engineexhaustand someof its constituentsareknown
to theStateof Californiato causecancer,birth defects
andotherreproductiveharm.
CALIFORNIAPROPOSITION65 WARNING
This productcontainsor emitschemicalsknown tothe
Stateof Californiato causecancer,birth defectsand
otherreproductiveharm.
1.1 UNPACKING
Removeall packagingmaterial.
Removeseparateaccessorybox.
Removethe generatorfrom carton.
1.1.1 ACCESSORYBOX
Checkall contents.If anyparts aremissing or damaged,locatean
authorizeddealerat 1-888-GENERAC.
1 - Owner'sManual 1 - HandleAssembly
1-LiterOiISAE30 1-FrameFoot
2 - Never-FlatWheels 1 - BatteryCharger(electric
start only)
1 - HardwareBag (containingthefollowing):
2-RubberFeet 2-M8Bolt(Long)
2-1/2"AxlePins 2-M8Bolts(Short)
2-CotterPins 2-M8AcornNut
2-1/2"FlatWashers 4-HexFlangedM8Nuts
1.2 ASSEMBLY
The generator requires some assembly prior to using it. If
problems arise when assemblingthe generator,please call the
GeneratorHetplineat 1-888-GENERAC.
1.2.1 ASSEMBLINGTHEACCESSORYKIT
The wheels are designed into the unit to greatly improve the
portability ofthe generator.
You will needthe following tools to properlyinstall the accessory
kit.
NeedleNosePliers
Ratchetand a 13mm (1/2") socket
13mm (1/2") boxwrench
NOTE:
The wheels are net intendedfor over-the-road use.
1. Refer to Figure 1 and install the Wheels as follows:
Slidethe AxlePinsthroughthe Wheel,1/2" FlatWasher,and Wheel
Bracketon the frame.
Insertthe CotterPinthroughthe AxlePinthenbendthetabs (ofthe
OotterPins) outwardto lock into place.
2. Refer to Figure 1 and install the Frame Foot and Rubber
Bumpers as shown.
Slidethe RubberBumperstuds throughthe FrameFootthen install
the LockingFlangeNuts.
Slidethe HexHeadBoltsthrough the holes in the FrameRail.
Slide the Frame Foot onto the Hex Head Bolts then install the
LockingFlangeNuts.
3. Refer to Figure 1 and install the Handle as shown.
Slidethe long Bolts through the HandleBracketand Handle,then
installthe HexNuts.
Figure 1- Wheel & Handle Assembly
Y_ H8 ]3r]LT
(LONG)
M8 ACORN NUT--,..,. -- -- -- L
\_ _ /_2x M8 BOLT
HANBLE _ _%, II II/ (SHORT)
.
FRAHE / 7" \ \ WASHER
FOOTJ / _ _2X COTTER
8X RUBBER FOOTJ _xPI:8
NUT
1.2.2 STARTERCONNECTION(ELECTRICSTARTONLY)
The unit has been deliberately shipped with the starter cable
disconnected.
Toconnectstarter:
1. Locatestarter cable.
2. Pullvinyl boot backonto startercable.
3. Removenutand washerfrom starter post.
4. Putstarter cableontopost and re-installwasher and nut.
2.1 KNOWTHEGENERATOR
Read the Owner'sManual and Safety Rules before operating
this generator.
Compare the generator to Figures 2 through 4 to become
familiarizedwith thelocationsofvariouscontrolsandadjustments.
Savethis manualfor future reference.
1. 120 VoltAC,20 Amp, DuplexReceptacle- Supplieselectrical
powerfor theoperationof 120VoltAC,20 Amp,single-phase,
60 Hzelectricallighting,appliance,tool and motor loads.
2. 120/240 Volt AC, 30 Amp LockingReceptacle - Supplies
electricalpowerfor the operationof 120 and/or240 VoltAC,
30 Amp, single-phase,60 Hz, electrical lighting, appliance,
tool andmotor loads.
3. CircuitBreakers(AC)- Eachreceptacleis providedwith a
push-to-reset circuit breakerto protectthe generatoragainst
electricaloverload.
4. Oil Drain- Useto drainengineoil.
5. Air Filter - Filtersintakeair as it isdrawn intothe engine.
6. ChokeKnob- Usedwhen startinga cold engine.
7. FuelTank- SeegeneratorSpecificationsfor tankcapacity.
8. Grounding Lug - Groundthe generatorto an approvedearth
groundhere.See"Groundingthe Generator"for details.
g. Run/Step Switch - Controls the operationof the generator
(pullstart models only).
gA. Start Switch - Used to start engine from the starter motor
(electricstart modelsonly).
10. Muffler - Quietsthe engine.
Figure 2 - Contro/ Pane/ Figure 4 - Generator Contro/s
11. Handle - Pivot and retract for storage. Press the spring-
loadedbuttonto move handles.
12. GasCap- Fuelfill location.
13. FuelGauge- Showsfuel levelin tank.
14. OilFill - Add oil here.
15. Recoil Starter - Useto start enginemanually.
15. FuelShut Off- Valvebetweenfueltank and carburetor.
17. Battery Charger Input - This receptacleallowsthe capability
to recharge the 12 volt DC storage battery provided with
the 12 Volt Adaptor Plug Chargerwhich is included in the
Accessory Box. Located behindthe battery chargerinput is
a 1.50 Amp in-line fuse which is inside the control panelto
protectthe batter(electricstart only).
18. Battery - Powersthe electricstarter (electricstart only).
19. Hourmeter- Trackshoursof operation.
Figure3 - GeneratorControls
2.2 HOURIVIETER
TheHourmetertrackshoursofoperationforscheduledmaintenance
(Figure5):
Therewill be a"CHGOIL"messageevery100 hours.Themessage
will flash one hour before and one hour after each 100 hour
interval,providinga two hourwindow to perform service.
This messagewill actuallybeginflashing at 99 hoursand disable
itselfat 101 hoursagain,providingatwo hourwindow to perform
theservice.
Every200 hoursthe "SVC"icon on the lower left hand corner of
thedisplay will flash. Themessagewill flash one hourbeforeand
onehour aftereach200 hourintervalprovidingatwo hourwindow
to perform service.
Whenthe hour meter is inthe FlashAlert mode, the maintenance
message will always alternate with elapsedtime in hours and
tenths. The hours wilt flash four times, then alternate with the
maintenancemessagefourtimes untilthemeter resetsitself.
* 100 hours- CHGOIL-- OilChangeInterval(Every100 hrs)
Note:
The hour glassgraphicwill flash on and off when the engine
is running.This signifiesthat the meter is tracking hours of
operation.
Figure 5 - Hourmeter Figure 7 - 120/240 VAC, 30 Amp Receptacle
HOURGLASS
GRAPHIC
0000.0
RESETBUTTON
(IF EQUIPPED)
2.3 CORDSETSANDCONNECTIONPLUGS
2.3.1 120VAC,20 AMP,DUPLEXRECEPTACLE
This is a 120 Volt outlet protectedagainst overloadby a 20 Amp
push-to-resetcircuitbreaker(Figure6). Useeachsocketto power
120 VoltAC, singlephase,60 Hzelectricalloadsrequiringup to a
combined 2400 watts (2.4 kW) or 20 Amps of current. Useonly
high quality,well-insulated, 3-wire grounded cord sets ratedfor
125 Volts at 20 Amps (or greater).
Keep extensioncords as short as possible, preferablyless than
15 feet long, to preventvoltagedrop and possibleoverheatingof
wires.
Figure 6 - 120 Vo/t AC, 20 Amp, Duplex Receptac/e
D
2.3.2 120/240VAC,30AMPRECEPTACLE
Use a NEMA L14-30 plug with this receptacle (rotate to lock!
unlock). Oonnecta suitable4-wire groundedcord set to the plug
andto thedesiredtoad.Thecordset shouldbe ratedfor 250 Volts
ACat30 Amps (or greater)(Figure7).
120V/240V
30A
Use this receptacleto operate120 Volt AC, 60 Hz, singlephase
loads requiringup to 3600 watts (3.6 kW) of powerat 30 Amps
or 240 Volt AC, 60 Hz,single phaseloads requiring up to 7200
watts (7.2 kW) of power at 30 Amps. The outlet is protectedby
two 25 Amp (5.0/5.5kW) or two 30 Amp (6.5kW) push-to-reset
circuit breakers.
2.4 HOW TO USETHEGENERATOR
If thereare any problems operatingthe generator,pleasecall the
generatorhelplineat 1-888-GENERAC.
2.4.1 GROUNDINGTHEGENERATOR
The National Electrical Code requires that the frame and
external electrically conductiveparts of this generator be
properlyconnectedto an approved earth ground (Figure 8).
Local electrical codes may also require proper grounding of the
unit. Forthat purpose, connectinga No. 10 AWG(AmericanWire
Gauge) stranded copper wire to the grounding lug and to an
earth-driven copper or brass grounding rod (electrode) provides
adequateprotectionagainstelectricalshock. However,localcodes
may vary widely. Consultwith a localelectricianfor grounding
requirementsin the area.
Figure8 - Groundingthe Generator
Propergroundingofthe generatorwill help preventelectrical
shockin the event of a ground fault condition in the generator
or in connectedelectrical devices. Proper grounding also helps
dissipate static electricity, which often builds up in ungrounded
devices.
2.4.2 CONNECTINGELECTR/CALLOADS
DONOTconnect240 Volt loadsto 120 Volt receptacles.DONOT
connect 3-phaseloads to the generator.DONOTconnect 50 Hz
loadsto thegenerator.
* Let engine stabilize and warm up for a few minutes after
starting.
* Plug in and turn on the desired 120 or 240 Volt AO, single
phase,60 Hzelectricalloads.
* Addup the ratedwatts (or amps) of all loadsto be connected
at onetime. This total should not be greaterthan (a) the rated
wattage/amperagecapacity of the generator or (b) circuit
breakerratingof thereceptaclesupplyingthe power.See"Don't
Overloadthe Generator".
2.5 DON'TOVEBLOADTHEGENEBATOB
Overloadinga generatorin excess of its ratedwattage capacity
can result in damageto the generatorandto connectedelectrical
devices.Observethefollowing to preventoverloadingthe unit:
* Addupthetotal wattageofall electricaldevicesto be connected
at one time. This total should NOT be greater than the
generator'swattagecapacity.
* The ratedwattageof lights can be takenfrom light bulbs. The
ratedwattageof tools, appliancesand motors can usually be
found on a datalabelor decalaffixedto the device.
* If the appliance,toot or motor does not givewattage, multiply
voltstimes ampereratingto determinewatts (voltsx amps =
watts).
* Some electric motors, such as induction types, require about
threetimes morewatts of powerfor startingthan for running.
This surge of power lasts only a few seconds when starting
such motors.Makesureto allowfor high startingwattagewhen
selectingelectricaldevicesto connectto the generator:
1. Figurethe watts neededto start the largestmotor.
2. Add to that figure the running watts of all other connected
loads.
TheWattageReferenceGuideis providedto assist in determining
how many itemsthe generatorcan operateatonetime.
NOTE:
All figures are approximate. See data label on appliancefor
wattage requirements.
2.6 WATTAGEBEFEBENCEGUIDE
Device ................................... RunningWatts
*Air Conditioner(12,000 Btu).......................... 1700
*Air Conditioner(24,000 Btu).......................... 3800
*Air Conditioner(40,000 Btu).......................... 6000
BatteryCharger(20 Amp).............................. 500
BeltSander(3") .................................... 1000
ChainSaw ........................................ 1200
CircularSaw (6-1/2") ........................... 800to 1000
*Clothes Dryer(Electric) ............................. 5750
*Clothes Dryer(Gas) ................................. 700
*Clothes Washer ................................... 1150
CoffeeMaker ...................................... 1750
*Compressor (1 HP)................................. 2000
*Compressor (3/4 HP)............................... 1800
*Compressor (1/2 HP)............................... 1400
CurlingIron......................................... 700
*Dehumidifier....................................... 650
Disc Sander(9").................................... 1200
EdgeTrimmer....................................... 500
Electric Blanket...................................... 400
Electric NailGun.................................... 1200
Electric Range(per element)........................... 1500
Electric Skillet...................................... 1250
*Freezer............................................ 700
*FurnaceFan(3/5 HP) ................................ 875
*GarageDoor Opener............................ 500to 750
Hair Dryer......................................... 1200
HandDrill .................................... 250to 1100
HedgeTrimmer...................................... 450
Impact Wrench...................................... 500
Iron.............................................. 1200
*Jet Pump ......................................... 800
Lawn Mower....................................... 1200
LightBulb.......................................... 100
Microwave Oven............................... 700to 1000
*Milk Cooler....................................... 1100
OilBurneron Furnace................................. 300
OilFiredSpaceHeater(140,000 Btu) ..................... 400
OilFiredSpaceHeater(85,000 Btu) ...................... 225
OilFiredSpaceHeater(30,000 Btu) ...................... 150
*Paint Sprayer,Airless (1/3 HP) ......................... 600
PaintSprayer,Airless (handheld)......................... 150
Radio ......................................... 50 to 200
*Refrigerator........................................ 700
SlowCooker........................................ 200
*Submersible Pump(1-1/2 HP) ........................ 2800
*SubmersiblePump (1 HP) ........................... 2000
*Submersible Pump(1/2 HP).......................... 1500
*Sump Pump................................. 800to 1050
*Table Saw(10") ............................. 1750to 2000
Television..................................... 200to 500
Toaster..................................... 1000to 1650
WeedTrimmer ...................................... 500
* Allow 3 times the listedwatts for starting these devices.
2.7 BEFORESTARTINGTHEGENERATOR
Priorto operatingthe generator,engineoil and gasolinewill need
to be added,asfollows:
2.7.1 ADD/NGENG/NEO/L
All oil should meet minimum American PetroleumInstitute (API)
Service Class SJ, SL or better.Use no special additives. Select
the oil's viscosity grade according to the expected operating
temperature(also seechart).
* Above40° F,useSAE30
* Below40° Fand downto 10° F,use10W-30
* Below10° F,usesynthetic5W-30
mEm!
ZEn
°F =20 =10 0 10 20 32 40 60 80 100
oc-3'0 -_o -;0 o 1'0 2'0 3'0 4o
Temperature Range of Expected Use
_,CAUTION!
,_t Any attempt to crank or start the engine
before it has been properly serviced with the
recommended oil may result in an engine
failure.
* Placegeneratoron a levelsurface (not to exceed15° in any
direction).
* Cleanareaaroundoil fill andremoveoil fill cap anddipstick.
* Wipedipstick clean.
* Slowly fill engine with oil through the oil fill opening until it
reachesthefull mark.Stopfilling occasionallyto checkoil level.
Becarefulnotto overfill.
* Installoil fill capandfinger tightensecurely.
* Checkengineoil levelbeforestarting eachtime thereafter.
2.7.2 ADDINGGASOLINE
Never fill fuel tank indoors. Never fill fuel tank
when engine is running or hot. Avoid spilling
gasoline on a hot engine. Allow engine to cool
entirely before filling fuel tank. DO NOT light a
cigarette or smoke when filling the fuel tank.
Do not overfill the fuel tank. Always leave room
for fuel expansion. If the fuel tank is overfilled,
fuel can overflow onto a hot engine and cause
FIRE or EXPLOSION. Wipe up any spilled fuel
immediately.
Do not light a cigarette or smoke when filling
the fuel tank. Gasoline is highly FLAMMABLE
and its vapors are EXPLOSIVE.
* UseregularUNLEADEDgasolinewith the generatorengine.Do
notuseanygasolinewith morethan10%addedethanol.Donot
useE85 gasoline.Donot mix oil with gasoline.
* Cleanareaaroundfuelfill cap, removecap.
* Slowlyaddunleadedregulargasolineto fueltank. Fillto bottom
of screenfilter.Becarefulnot to overfill(Figure9).
* Installfuelcap andwipe up any spilledgasoline.
Figure9 - Fuel Tank
FuelTank
Fuel/ DONOTFillAbove Lip
IMPORTANT:It isimportantto preventgum depositsfrom forming
in fuel system parts such as the carburetor,fuel hose or tank
during storage. Alcohol-blendedfuels (called gasohol, ethanol
or methanol)can attract moisture, which leadsto separationand
formationof acids duringstorage.Acidic gascandamagethefuel
system of an enginewhile in storage.Toavoid engineproblems,
the fuel system should be emptiedbefore storage of 30 days or
longer.Seethe "Storage"section. Neveruseengineor carburetor
cleanerproductsinthefueltank aspermanentdamagemay occur.
2.8 STARTINGPULLSTARTENGINES
Never start or stop engine with electrical
devices plugged into the receptacles AND
devices turned on.
* Unplug all electrical loads from the unit's receptaclesbefore
startingthe engine.
* Makesurethe unit is in a levelposition (notto exceed15° in
anydirection).
* OPENthe FuelShut-offValve(Figure10).
* TurnengineRUN/STOPswitch to ONposition(Figure11).
* Slideenginechoketo the LEFTto FULLCHOKEposition (Figure
12).
. Tostart engine,firmly graspthe recoil handleand pull slowly
until increasedresistanceisfelt. Pullrapidlyup and away.
Whenenginestarts, move choke knobto 1/2-CHOKEposition
until engineruns smoothly andthen fully into RUNposition.If
engine falters, move choke back out to 1/2-CHOKEposition
untilengineruns smoothly andthento RUNposition.
NOTE:
if enginefires, but doesnot continueto run, movechokelever
to FULLCHOKEand repeatstartinginstructions.
Figure 10 - FuelShut-offVaNe
FUEL SHUTOFF
Figure 11 - Engine ON/OFF Switch
ENGINE ON/OFF SWITCH
(PULL START ENGINES ONLY)
Figure 12 - Choke Position
CHOKELEVER
LEFT = CHOKE--
RIGHT = RUN
IMPORTANT:Donotoverloadthe generator.Also, do not overload
individual panel receptacles.These outlets are protectedagainst
overload with push-to-reset-type circuit breakers. If amperage
rating of any circuit breakeris exceeded,that breakeropensand
electricaloutputtothat receptacleis lost.Read"Don't Overloadthe
Generator"carefully.
2.9 STARTINGELECTRICSTARTENGINES
Never start or stop engine with electrical
devices plugged into the receptacles AND
devices turned on.
Unplug all electrical loads from the unit's receptaclesbefore
startingthe engine.
Make surethe unit is in a levelposition (notto exceed15° in
anydirection).
Openthefuel shut-off valve (Figure10).
Move engine CHOKEknob outward to FULLCHOKEposition
(Figure12).
To start engine, press and hold the Start/Run/Stop switch in
the"Start" position.Theenginewill crankand attemptto start.
Whenthe enginestarts, releasethe switch tothe run position.
When the engine starts, move choke knob to "1/2 Choke"
position untilthe engine runssmoothly and thenfully in to the
"Run" position.If enginefalters, move chokeknob back outto
"1/2 Choke"position until the engine runs smoothly and then
to "Run" position.
This generator is also equippedwith a manual recoil starter
which may be usedif the batteryis discharged.
NOTE:
The switch must be in the RUN position. Use one of the
generator's receptacle outlets along with the includedbattery
chargerto chargethe battery whilethe generator is running.
Tostart manually,firmly graspthe recoilhandleand pull slowly
until increasedresistance is felt. Pull rapidly up and away to
start engine.Thenfollow the samechoke sequence.
NOTE:
if enginefires, but does not continueto run,move chokelever
to FULLCHOKEand repeatstartinginstructions.
IMPORTANT:Donotoverloadthe generator.Also, do not overload
individual panel receptacles.These outlets are protectedagainst
overload with push-to-reset-type circuit breakers. If amperage
rating of any circuit breakeris exceeded,that breakeropensand
electricaloutputtothat receptacleis lost.Read"Don't Overloadthe
Generator"carefully.
2.10STOPPINGTHEENGINE
Shutoff all loads,thenunplugtheelectricalloadsfrom generator
panelreceptacles.Neverstart or stop theenginewith electrical
devicespluggedin andturnedon.
Let engine run at no-load for several minutes to stabilizethe
internaltemperaturesof engineandgenerator.
Move Run/Stopswitch to OFFposition.
Closefuelvalve.
2.11LOWOiLLEVELSHUTDOWNSYSTEM
Theengineis equippedwith a low oil levelsensorthat shutsdown
the engineautomaticallywhenthe oil leveldropsbelowa specified
level. If the engine shuts down by itself and the fuel tank has
enoughgasoline,checkengineoil level.
2.11.1 SENSINGLOWOILLEVEL
If the system senses a low oil levelduring operation,the engine
shuts down. The enginewill not run untilthe oil has beenrefilled
to the properlevel.
2.12CHARGINGTHEBATTERY(ELECTRICSTART
UNITSONLY)
Storage batteries give off explosive hydrogen
gas while recharging. An explosive mixture will
remain around the battery for a long time after
it has been charged. The slightest spark can
ignite the hydrogen and cause an explosion.
Such an explosion can shatter the battery and
cause blindness or other serious injury.
,_Do not permit smoking, open flame, sparks
or any other source of heat around a battery.
Wear protective goggles, rubber apron and
rubber gloves when working around a battery.
Battery electrolyte fluid is an extremely
corrosive sulfuric acid solution that can cause
severe burns, if spill occurs flush area with
clear water immediately.
NOTE:
The battery shipped withthe generator has been fully charged.
A battery may lose some of its chargewhen not in use for
prolongedperiodsof time. If the battery isunable to crankthe
engine, plugin the 12V chargerincludedin the accessory box
(seesection"Chargingthe Battery").RUNNINGTHEGENERATOR
DOESNOTCHARGETHEBATTERY.
Usebatterychargerplugto keepthebatterychargedandreadyfor
use. Batterychargingshouldbe done in a dry location.
1. Plugchargerinto "BatteryChargerInput"jack, locatedon the
control panel.Plugwall receptacleend of the batterycharger
into a 120 VoltACwalt outlet (Figure13).
1o
2. Unplugbatterychargerfrom wall outlet andcontrol paneljack
whengeneratoris goingto be in use.
NOTE:
Do not use the battery chargerfor more than 48 hoursat one
charge.
Figure 13 - Battery Charger Jack
BATTERY
CHARGER
INPUT
3.1 MAINTENANCESCHEDULE
Follow the calendar intervals. More frequent service is required
whenoperatingin adverseconditionsnotedbelow.
CheckOil Level
ChangeOil :_
CheckValveClearance
ServiceAir Filter
ReplaceSparkPlug
At EachUse
*Every 100 hoursor EverySeason
***Every Season
** Every200 hoursor EverySeason
EverySeason
$ Changeoil after first 30 hours of operationthen every season.
* Changeoiland oilfilter every monthwhen operatingunderheavyload or in high
temperatures.
** Cleanmore often under dirty or dusty operatingconditions. Replaceairfilter
parts if they cannot beadequatelycleaned.
*** Check valve clearance and adjust if necessary after first 50 hours of
operationand every 100 hoursthereafter.
3.2 PRODUCTSPECIFICATIONS
3.2.1 GENERATORSPECIFICATIONS
RatedPower............................................................... 5.0/5.5/6.5 kW**
SurgePower............................................................... 6.25/6.88/8.0 kW
RatedACVoltage...................................................................... 120/240
RatedAC Load
Current@ 240V (5.0/5.5/6.5 kW) ..................20.8/22.9/27.1 Amps**
Current@ 120V (5.0/5.5/6.5 kW) ..................41.6/45.8/54.2 Amps**
RatedFrequency.................................................... 60 Hz@ 3600 RPM
Phase................................................................................ SinglePhase
** Maximumwattageandcurrentaresubjectto,andlimitedby,suchfactors
asfuelBtucontent,ambienttemperature,altitude,enginecondition,etc..
Maximumpowerdecreasesabout3.5%foreach1,000feetabovesealevel;
andwillalsodecreaseabout1%foreach6° C(10° F)above16° C(60° F)
ambienttemperature.
3.2.2 ENG/NESPEC/F/CAT/ONS
Displacement.............................................................................. 389 cc
SparkPlugType................................ NHSPLDF7TCor ChampionN9YC
SparkPlug PartNo........................................................... 0G84420101
SparkPlug Gap.............................0.028-0.031 inch or (0.70-0.80 mm)
GasolineCapacity......................................................... 7.2 U.S.gallons
OilType.................. SeeChartin "BeforeStartingthe Generator"Section
OilCapacity.................................................................... 1 L (1.06 Qts.)
RunTimeat 50% Load (5.0/5.5/6.5 kW)..................................10 Hours
3.2.3 EMISSIONSINFORMATION
The EnvironmentalProtection Agency (EPA) requires that this
generatorcomply with exhaustemission standards. The engine
used in this generator is certified to meet the applicable EPA
emission levels. It is important to follow the maintenance
specifications providedin this manualsto ensurethat the engine
complies with the applicableemission standardsfor the duration
of theengine'slife. Theemissioncontrol system onthis generator
consists ofthe following:
* Air Induction system * Ignition System
IntakePipe/Manifold - SparkPlug
Air Cleaner _ IgnitionCoil
* Exhaust System * Fuel System
Exhaustmanifold _ Carburetor
Muffler
The Emissions CompliancePeriod referredto on the Emissions
Compliance Label indicates the number of operating hours
for which the engine has been shown to meet EPA emission
requirements.
3.3 GENERALRECOMMENDATIONS
Thewarrantyofthe generatordoesnotcover itemsthathavebeen
subjectedto operatorabuse or negligence.To receive full value
from the warranty, the operatormust maintain the generatoras
instructed inthis manual.
Some adjustmentswill needto be made periodicallyto properly
maintainthegenerator.
All adjustmentsin the Maintenancesection of this manualshould
bemadeat leastonceeachseason.Followthe requirementsin the
"MaintenanceSchedule".
NOTE:
Once a year replacethe sparkplug and replacethe air filter.
A new spark plug and clean air filter assure properfuel-air
mixture and helpthe engine runbetter and last longer.
3.3.1 GENERATORMAINTENANCE
Generatormaintenanceconsists of keepingtheunitcleanand dry.
Operateand storethe unitin a cleandry environmentwhere itwill
not be exposedto excessivedust, dirt, moistureor any corrosive
vapors. Cooling air slots in the generator must not become
cloggedwith snow, leaves,or anyotherforeign material.
Checkthe cleanlinessof the generatorfrequentlyandcleanwhen
dust, dirt, oil, moistureor otherforeignsubstancesarevisible on
its exteriorsurface.
A.CAUTION!
_h Never insert any object or tool through the air
cooling slots, even if the engine is not running.
NOTE:
DONOTuse a gardenhoseto cleangenerator. Water canenter
the enginefuel systemand causeproblems.In addition, ifwater
enters thegenerator throughcoolingair slots,somewaterwill
be retainedinvoidsand crevicesof therotorand statorwinding
insulation.Water and dirt buildup on the generator internal
windingswill eventually decreasetheinsulationresistanceof
these windings.
3.3.2 TOCLEANTHEGENERATOR
* Usea dampcloth to wipe exteriorsurfaces clean.
* A soft, bristle brush may be usedto loosencaked on dirt, oil,
etc.
* Avacuumcleanermay beusedto pick uploosedirt anddebris.
* Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and openings
on the generator.These openings must be kept clean and
unobstructed.
3.3.3 ENGINEMAINTENANCE
/_When working on the generator, always
disconnect spark plug wire from spark plug and
keep wire away from spark plug.
3.3.4 CHECKINGOILLEVEL
Seethe "BeforeStartingthe Generator"sectionfor informationon
checkingthe oil level.Theoil levelshouldbe checkedbeforeeach
use, or at least every eight hours of operation.Keepthe oil level
maintained.
3.3.5 CHANGINGTHEOIL
Changethe oil after every 100 hours. If running this unit under
dirty or dusty conditions, or in extremelyhotweather,changethe
oil moreoften.
,&CAUTION!
,_Hot oil may cause burns. Allow engine to
cool before draining oil. Avoid prolonged
or repeated skin exposure with used oil.
Thoroughly wash exposed areas with soap.
Use thefollowinginstructionsto changethe oil after the engine
coolsdown:
* Cleanareaaroundoil drainplug.
* Removeoil drain plug from engine and oil fill plug to drain oil
completelyinto a suitablecontainer.
* When oil has completely drained, install oil drain plug and
tightensecurely.
* Fill engine with recommendedoil. (See "Before Starting the
Generator"for oil recommendations).
11
Wipeup anyspilledoil.
Disposeof usedoil at a propercollectioncenter.
3.3.6 REPLACINGTHESPARKPLUG
Use ChampionN9YCspark plug or equivalent.Replace the plug
once each year. This will help the engine start easier and run
better.
1. Stopthe engineand pull the spark plug wire off of the spark
plug.
2. Cleanthe area aroundthe spark plug and remove it from the
cylinder head.
3. Setthe spark plug's gap to 0.70-0.80 mm (0.028-0.031 in.).
Installthe correctly gappedspark plug intothe cylinder head
(Figure14).
Figure 14 - Spark Plug Gap
3.3.7 BATTERYREPLACEMENT
NOTE:
Thebatteryshippedwith the generator hasbeen fully charged.
A battery may lose some of its charge when not in use for
prolongedperiodsof time. If the battery is unable to crank
the engine,plug in the 12V chargerincludedin the accessory
box (see the Charging a Battery section). RUNNING THE
GENERATORDOESNOTCHARGETHEBATTERY.Thepartnumber
for this battery is 069449.
,_ CAUTION!
,_The NEGATIVE battery terminal should:
1. Always be DISCONNECTEDFIRST.
2. Alwaysbe CONNECTEDLAST.
Figure15 - Battery Connections
3.4 SERVICEAiRFILTER
Theenginewilt not run properlyand may be damagedif usinga
dirty air filter. Cleanthe air filter every 200 hours or once a year
(Figure16). Cleanor replacemore often if operatingunderdusty
conditions.Theair filter part numberis 0G84420151.
Removeairfilter cover.
Washin soapy water.Squeezefilter dry in cleancloth (DONOT
TWIST).
Cleanair filter cover beforere-installingit.
NOTE:
Toorder a new air filter, pleasecontactthe nearestauthorized
servicecenterat 1-888-GENERAC.
Figure 16- Air Filter
CLIP_
12
3.5 VALVECLEARANCE
* Intake-- 0.15 __O.02mm(cold), (0.006" __0.0008" inches)
* Exhaust-- 0.20 _ O.02mm(cold) (0.008" _ 0.0008" inches)
Afterthefirst 50 hoursof operation,checkthevalveclearance
in theengineand adjustif necessary.
Important: If feelinguncomfortableaboutdoing this procedureor
theproper tools are not available,pleasetake the generatorto the
nearestservicecenterto havethevalveclearanceadjusted.This is
a very importantstepto ensurelongestlifefor theengine.
3.6 GENERAL
Thegeneratorshould be started at least once every 30 days and
be allowedto run at least 30 minutes. If this cannot be done and
the unit must be stored for morethan 30 days, use thefollowing
informationas a guideto prepareitfor storage.
NEVER store engine with fuel in tank indoors
or in enclosed, poorly ventilated areas where
fumes may reach an open flame, spark or pilot
light as on a furnace, water heater, clothes dryer
or other gas appliance.
,_AIIow unit to cool entirely before storage.
3.7 LONGTERMSTORAGE
It is importantto preventgum depositsfrom forming in essential
fuel systemparts such asthe carburetor,fuel hoseor tank during
storage. Also, experience indicates that alcohol-blended fuels
(called gasohol,ethanolor methanol)can attract moisture,which
leadsto separationandformation of acids during storage.Acidic
gascan damagethefuel systemof an enginewhile in storage.
To avoid engine problems, the fuel system should be emptied
beforestorageof 30 daysor longer,asfollows:
* Removeall gasolinefrom the fueltank.
Drain fuel into approved container outdoors,
away from open flame. Be sure engine is cool.
Do not smoke.
* Startand run engineuntilenginestopsfrom lack of fuel.
* Whileengineis still warm, drain oil from crankcase.Refillwith
recommendedgrade.
* Removespark plugandpour about1/2 ounce(15 ml) of engine
oil into the cylinders. Coverspark plug hole with rag. Puttthe
recoil starter a couple times to lubricatethe piston rings and
cylinder bore.
ACAUTION!
,_Avoid spray from spark plug hole when
cranking engine.
* Installandtighten spark plug.Donot connectspark plugwire.
* Cleanthe generatoroutersurfaces.Checkthat cooling air slots
and openingson generatorareopen andunobstructed.
* Storethe unit in a clean, dry place.
3.8 OTHERSTORAGETiPS
* Do notstore gasolinefrom oneseasonto another.
* Replacethe gasolinecan if it starts to rust. Rustand/ordirt in
the gasolinewill cause problems with the carburetor and fuel
system.
* If possible,storethe unit indoorsandcover it to giveprotection
from dust anddirt. BESURETOEMPTYTIdEFUELTANK.
* If it is not practicalto emptythe fuel tank and the unit is to be
storedfor sometime, useacommerciallyavailablefuelstabilizer
addedto the gasolineto increasethe lifeof thegasoline.
* Coverthe unit with a suitable protective cover that does not
retainmoisture.
,_ NEVER cover the generator while engine and
exhaust areas are warm.
13
4.1 TROUBLESHOOTINGGUIDE
Engineisrunning,but no ACoutput
is available.
1. Circuit breakeris open.
2. Poorconnectionor defectivecord set.
3. Connecteddevice is bad.
4. Faultin generator.
1. Resetcircuit breaker.
2. Checkand repair.
3. Connectanotherdevicethat is in good condition.
4. ContactAuthorizedService Facility.
Engine runs good but bogs down 1. Short circuit in a connectedload. 1. Disconnectshorted electricalload.
whenloadsareconnected. 2. Generatoris overloaded. 2. See"Don't Overloadthe Generator".
3. Enginespeedis too slow. 3. ContactAuthorizedService Facility.
4. Shorted generatorcircuit. 4. ContactAuthorizedServiceFacility.
Enginewill notstart;orstartsand
runsrough.
FuelShut-off is OFF.
Dirtyair filter.
Out of gasoline.
Stale gasoline.
Sparkplug wire not connectedto sparkplug.
1. TurnFuelShut-off ON.
2. Cleanor replaceair filter.
3. Fillfuel tank.
4. Drainfuel tank andfill with fresh fuel.
5. Connectwireto sparkplug.
,
2.
3.
4.
5.
6. Badsparkplug.
7. Waterin gasoline.
8. Overchoking.
9. Low oil level.
10. Excessiverich fuel mixture.
11. Intakevalvestuck open or closed.
12. Enginehas lost compression.
6. Replacesparkplug.
7. Drainfuel tank;fill with freshfuel.
8. Put chokeknobto No Chokeposition.
9. Fillcrankcaseto proper level.
10. ContactAuthorizedServiceFacility.
11. ContactAuthorizedServiceFacility.
12. ContactAuthorizedServiceFacility.
Engineshuts down during 1. Out of gasoline. 1. Fillfuel tank.
operation. 2. Lowoil level. 2. Fillcrankcaseto proper level.
3. Faultin engine. 3. ContactAuthorizedService Facility.
I I
Engine lacks power. 1. Loadis too high. 1. Reduceload (see"Don't Overloadthe Generator").
2. Dirtyair filter. 2. Cleanor replaceair filter.
3. Engineneedsto be serviced. 3. ContactAuthorizedServiceFacility.
R
Engine "bunts" orfalters. 1. Chokeis openedtoo soon. 1. Movechoketo halfway position untilengineruns
smoothly.
2. Carburetoris runningtoo rich ortoo lean. 2. ContactAuthorizedServiceFacility.
14
FEDERALEMiSSiONCONTROLWARRANTYSTATEMENT
YOURWARRANTYRIGHTSANDOBLiGATiONS
TheUnitedStatesEnvironmentalProtectionAgency (EPA)andGeneracPowerSystems, Inc. (Generac)arepleasedto explainthe EmissionOontrol
Systemwarranty onyour new 2008 andlaterequipment.Newequipmentthat usesmall spark-ignitedenginesmust be designed,built, and equipped
to meetstringentanti-smog standardsfor the federalgovernment. Generacwill warrantthe emission control systemon your generatorfor the period of
time listed below providedthere has beenno abuse,neglect,unapprovedmodificationor impropermaintenanceof your equipment.
Youremissioncontrol systemmay includeparts such asthe: carburetor,ignition system,fuel system,catalytic converter,andother associated
emission-relatedcomponents(if equipped).
MANUFACTURER'SWARRANTYCOVERAGE:
This emissioncontrol system is warrantedfor two years. If,during such warranty period,any emission-relatedpart on your equipmentis found to be
defectivein materials or workmanship,repairsor replacementwill beperformed by a GeneracAuthorizedWarrantyServiceDealer.
OWNER'SWARRANTYRESPONSiBiLiTiES:
Asthe generatorowner,you areresponsiblefor the completion of all requiredmaintenanceas listedin your factory suppliedOwner'sManual.For
warrantypurposes, Generacrecommendsthat you retainall receipts covering maintenanceon your generator,but Generaccannot denywarranty
solelydueto the lackof receipts.
Asthe generatorowner,you shouldbe awarethat Generacmay denyany and/orall warranty coverageor responsibilityif your generator,or apart!
componentthereof, hasfailed dueto abuse,neglect, impropermaintenanceor unapprovedmodifications,or the useof counterfeit and/or"grey market"
parts not made,suppliedor approvedby Generac.
Youare responsible for contactinga GeneracAuthorizedWarrantyDealer as soon as a problemoccurs.The warrantyrepairsshould he
completed in a reasonable amount oftime, not to exceed 30 days.
Warrantyservice can be arrangedby contacting eitheryour sellingdealer or a GeneracAuthorizedWarrantyServiceDealer.To locatethe Generac
AuthorizedWarrantyServiceDealernearestyou, call ourtoll free number:
1-800-333-1322
IMPORTANTNOTE:Thiswarranty statementexplainsyour rightsand obligationsunderthe EmissionOontrolSystemWarranty (EOSWarranty),which
is providedto you by Generacpursuanttofederallaw. See alsothe "GeneracLimitedWarrantiesfor GeneracPowerSystems, Inc.,"which is enclosed
herewith on aseparatesheet, alsoprovidedto you by Generac.Notethatthis warrantyshall not applyto anyincidental,consequentialor indirect
damagescausedby defectsin materials or workmanship or any delayin repair or replacementof the defectivepart(s). This warranty is in placeof all
other warranties,expressedor implied.Specifically,Generacmakesno otherwarranties asto the merchantabilityor fitnessfor aparticular purpose.
Any impliedwarrantiesallowedby law shall belimited in durationto theterms of the expresswarrantyprovidedherein. Somestates do not allow
limitationson how long an impliedwarrantylasts, so the abovelimitationmay not applyto you.
TheEOSWarrantyappliesonlyto the emission control systemof your new equipment.If thereis anyconflict in terms betweenthe ECSWarrantyand
the GeneracWarranty,the GeneracWarrantyshall apply.Boththe EOSWarrantyand the GeneracWarrantydescribe importantrights and obligations
with respectto your new engine.
Warrantyservice can be performedonly by aGeneracAuthorizedWarrantyServiceFacility.Whenrequestingwarranty service,evidencemust be
presentedshowing the dateof the saleto the original purchaser/owner.
If you haveany questions regardingyourwarranty rights and responsibilities,you should contactGeneracatthe following address:
ATTENTIONWARRANTYDEPARTMENT
GENERACPOWERSYSTEMS,iNC.
P.O.BOX297 WHITEWATER,Wl 53190
Part I
PartNo. 0H1911 Rev.C 03/12
16
EMiSSiONCONTROLSYSTEMWARRANTY
EmissionControlSystemWarranty (ECSwarranty) for equipmentusingsmall spark-ignitedengines:
(a) Applicability: Thiswarranty shall apply to equipmentthatuses small off-road engines.TheECSWarranty period shallbeginon the datethe new
equipmentis purchasedby/deliveredto its original,end-use purchaser/ownerand shall continuefor 24 consecutivemonths thereafter.
(b) GeneralEmissionsWarrantyCoverage:Generacwarrants to the original,end-use purchaser/ownerof the new engineor equipmentandto each
subsequentpurchaser/ownerthat the ECSwhen installedwas:
(1) Designed,builtandequippedso as to conform with all applicableregulations;and
(2) Freefrom defects in materialsand workmanshipwhich causethe failure of awarrantedpart at anytime duringthe ECSWarranty Period.
(c) Thewarrantyon emissions-relatedparts will be interpretedasfollows:
(1) Anywarrantedpart that is not scheduledfor replacementasrequiredmaintenancein the Owner'sManualshall be warrantedfor the ECS
WarrantyPeriod.Ifany such part fails duringthe ECSWarrantyPeriod,it shall berepairedor replacedby Generacaccordingto Subsection
(4) below.Any such part repairedor replacedunderthe ECSWarrantyshallbe warrantedfor the remainderofthe ECSWarrantyPeriod.
(2) Anywarrantedpart that is scheduledonlyfor regularinspectionas specifiedin theOwner'sManualshall bewarrantedfor the ECSWarranty
Period.A statementin the Owner's Manualto the effect of "repairor replaceas necessary" shallnot reducethe ECSWarrantyPeriod.Any
such part repairedor replacedunderthe ECSWarrantyshall be warrantedfor the remainderof the ECSWarrantyPeriod.
(3) Anywarrantedpart that is scheduledfor replacementas requiredmaintenancein the Owner'sManual shallbewarrantedfor the period oftime
prior to first scheduledreplacementpoint for thatpart. Ifthe partfails prior to the first scheduledreplacement,the part shallbe repairedor
replacedby Generacaccordingto Subsection(4) below.Any such emissions-relatedpart repairedor replacedunderthe ECSwarrantyshall
be warrantedfor the remainderofthe periodprior to the first scheduledreplacementpointfor that part.
(4) Repairor replacementof any warranted,emissions-relatedpart underthis ECSWarranty shall be performedat no chargeto the owner at a
GeneracAuthorizedWarrantyServiceFacility.
(5) Notwithstandingthe provisions of subsection (4) above,warrantyservicesor repairsmustbe providedatGeneracAuthorizedService
Facilities.
(6) Whenthe engineis inspectedby a GeneracAuthorizedWarrantyServiceFacility,the purchaser/ownershallnot be held responsiblefor
diagnostic costs if the repair is deemedwarrantable.
(7) Throughoutthe ECSWarrantyPeriod,Generacshallmaintaina supply of warrantedemission-relatedparts sufficientto meetthe expected
demandfor such parts.
(8) Any Generacauthorizedand approvedemission-relatedreplacementparts may be usedin the performanceof any ECSwarranty maintenance
or repairsand will be providedwithout chargeto the purchaser/owner.Such use shallnot reduceGeneracECSWarrantyobligations.
(9) Unapproved,add-on, modified,counterfeitand/or"grey market"parts may not beusedto modify or repaira Generacengine.Such usevoids
this ECSWarranty and shallbe sufficientgroundsfor disallowingan ECSWarrantyclaim. Generacshallnot beheld liablehereunderfor
failuresof anywarrantedparts of Generacequipmentcausedbythe useof such anunapproved,add-on, modified,counterfeit and/or "grey
market" part.
EMISSIONRELATEDPARTSMAYINCLUDETHEFOLLOWING(IF EQUIPPED):
1) FUELMETERINGSYSTEM
A. CARBURETORANDINTERNALPARTS
B. PRESSUREREGULATOR
2) AIR INDUCTIONSYSTEM
A. INTAKEMANIFOLD
B. AIR FILTER
3) IGNITIONSYSTEM
A. SPARKPLUGS
B. IGNITIONCOILS/ MODULE
4) AIR INJECTIONSYSTEM
A. PULSEAIRVALVE
5) EXHAUSTSYSTEM
A. CATALYST
B. THERMALREACTOR
C. EXHAUSTMANIFOLD
Part2
PartNo.0H1911 Rev.C 03/12
]'7
GENERAC POWER SYSTEMS "TWO YEAR" LiMiTED WARRANTY
FOR GP SERIES PORTABLE GENERATORS
For a period of two (2) yearsfrom the dateof original sale,GeneracPower Systems,Inc. (Generac)warrants its GPSeriesgeneratorswill befree from defects in materials
andworkmanship for the itemsand period set forth below. Generacwill, at its discretion, repair or replaceany part that, uponexamination, inspection andtesting by
Generacor a GeneracAuthorizedWarranty Service Dealer,isfound to be defective.Repairor replacementpursuant to this limited warranty shall not renew or extendthe
original warrantyperiod. Any repairedproduct shall bewarrantedfor the remaining original warranty period only. Any equipmentthatthe purchaser/owner claims to be
defective must be returnedto andexamined bythe nearest GeneracAuthorizedWarranty Service Dealer.All transportation costs underthewarranty, including return to
thefactory, areto be borneand prepaid bythe purchaser/owner.This warranty appliesonly to GeneracGPSeriesportable generatorsand is not transferablefrom original
purchaser.Saveyour proof-of-purchase receipt. If you donot provide proof of theinitial purchasedate, the manufacturer's shipping dateof the product will be usedto
determinethe warranty period.
WARRANTY SCHEDULE
Consumer applicationsare warrantedfor two (2) years. Commercial andRentalapplications arewarranted for one(1) year or 1000 hours maximum, whichever comes first.
CONSUMERAPPLICATIONFORTHEUNITEDSTATESANDCANADAONLY
YEARONE- Limited comprehensivecoverageon Laborand Part(s) listed (proof of purchaseand maintenanceis required):
Engine-All Components
Alternator-All Components
YEARTWO- Limited comprehensive coverageon Part(s) listed (proof of purchaseandmaintenanceis required):
Engine-All Components
Alternator-All Components
COMMERCIAl./RENTALAPPLICATION
YEARONE- Limited comprehensivecoverageon Laborand Part(s) listed (proof of purchaseand maintenanceis required):
Engine-All Components
Alternator-All Components
NOTE: Forthe purpose of this warranty "consumer use" meanspersonalresidentialhousehold or recreationaluse by original purchaseEThis warranty does not applyto
units used for Prime Powerin placeof utilitywhere utility power service is presentor where utility power service does not normally exist.Oncea generatorhas experienced
commercial or rental use, itshall thereafter beconsidered a non-consumeruse generatorfor the purpose ofthis warranty.
GUiDELiNES:
1. All warranty repairs, must be performed and/oraddressedby an Authorized/CertifiedGeneracDealer,or branchthereof.
2. Units thathave beenresoldare not coveredunderthe GeneracWarranty,as this Warranty is nottransferable.
3. Use of Non-Generacreplacementpart(s) will void the warranty in its entirety.
4. Generacmay chooseto Repair,Replaceor Refunda piece of equipment.
5. Warranty LaborRates arebased on normal working hours. Additionalcosts for overtime,holiday or emergency labor costs for repairs outsideof normal business hours
will bethe responsibility of the customer.
6. Warranty Parts shipment costs are reimbursedat groundshipment rates. Costsrelatedto requestsfor expeditedshippingwill bethe responsibility of the customer.
7. Batteries arewarranted by the battery manufactureK
8. Verification of required maintenancemay be requiredfor warranty coverage.
THiS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:
1. Costs of normal maintenanceand adjustments.
2. Failurescausedby any contaminatedfuels, oils or lack of proper oil levels.
3. Repairsor diagnostics performed by individuals otherthan Generacauthorizeddealersnot authorizedin writing byGenerac.
4. Failuresdue,but not limitedto, normal wear andtear,accident, misuse, abuse, negligenceor improper use.
5. As with all mechanical devices,the Generacenginesneed periodic part(s) service and replacementto perform as designed.This warranty will notcover repairwhen
normal use has exhaustedthe life of a part(s) or engine.
6. Failurescausedby any externalcause or act of God, such as collision, theft, vandalism, riot or wars, nuclearholocaust,fire, freezing,lightning, earth-quake,windstorm,
hail, volcanic eruption, water or flood, tornado or hurricane.
7. Damage relatedto rodentand/or insect infestation.
8. Products that are modified or alteredin a mannernot authorizedby Generacin writing.
9. Any incidental, consequentialor indirect damagescausedby defects in materials or workmanship, or any delay in repair or replacementof the defectivepart(s).
10. Failuredueto misapplication.
11. Expensesrelated to "customer instruction" or troubleshooting whereno manufacturing defect is found.
12. Rentalequipmentused while warranty repairs arebeing performed.
13. Starting batteries,fuses, light bulbsand enginefluids.
THISWARRANTYIS IN PLACEOFALL OTHERWARRANTIES,EXPRESSEDORIMPLIED.SPECIFICALLY,GENERACMAKESNO OTHERWARRANTIESAS TOTHE
MERCHANTABILITYOR FITNESSFORA PARTICULARPURPOSE.Any implied warranties allowed by law shall be limited induration to theterms of the expresswarranty
provided herein.Some statesdo not allow limitations on how long an implied warranty lasts, so theabove limitation may notapply to you. GENERAC'SONLYLIABILITY
SHALL BETHEREPAIRORREPLACEMENTOFPART(S)AS STATEDABOVE.INNO EVENTSHALLGENERACBELIABLEFORANY INCIDENTALOR CONSEQUENTIAL
DAMAGES,EVENIFSUCHDAMAGESAREA DIRECTRESULTOFGENERAC'SNEGLIGENCE.Some statesdo not allow the exclusionor limitationof incidental or
consequentialdamages,so theabove limitation may notapply to you. This warranty gives you specific legal rights.You also haveother rightsfrom state to state.
GENERAC POWER SYSTEMS, INC. R0. BOX 8 Waukesha, Wl 53187 Ph: (888) GENERAC (436-3722) Fax: (262) 544-4851
To locate the nearest Authorized Dealer visit our webs/re www.generac.com
Part No. 0H8902 RevisionG (08/12)
Manual Part No. 0H9059 Rev. E (11/27/12) Printed in China.
No inserteobjetosatravesdelas ranurasdeenfriamientodela unidad.
No opere el generador si los dispositivos electricos conectados
se recalientan,si se pierde la corriente de salida, si el motor o el
generadorgeneranchispas o si se observanllamas o humo mientras
la unidadesta enfuncionamiento.
Tenga un extintor cerca det generador en todo momento.
INO/CEDENORMAS
Enausenciade las normas, codigos, reglamentosy leyespertinentes,la
informacion publicadaque se lista a continuaci6n puede utilizarsecomo
pautaparala operaciondeesteequipo.Siempreconsultela ultimarevision
disponiblede lasnormas listadas.
1. NFPAN.° 70, MANUALDE LANFPASOBREELCODtGOELI_CTRICO
NACIONAL.
2. Articulo X, OODIGONAOtONALDE LA OONSTRUOOION,disponible
dela AmericanInsuranceAssociation,85 John Street,NewYork,N.Y.
10038.
3. MANUALDECABLEADOAGR[COLA,disponible delFoodandEnergy
Oouncil,909 UniversityAvenue,Oolumbia,MO65201.
4. ASAE EP-3634, INSTALACIONY MANTENIMIENTODE SISTEMAS
ELECTRICOSDERESERVAENGRANJAS,disponible dela American
Society of Agricultural Engineers,2950 Niles Road,St. Joseph, MI
49085.
MODELON°:
NODESERIE:
Ubicad6n del IP de la .nidad
CALCOMAN[A
DE DATOSDEL
MODELO
ADVERTENCIAPROPOSICI()N65 DECALIFORNIA
EtEstadode Californiasabeque el escapedetmotor y algunos
desus componentescausancancer,defectosde
nacimientoy otros dar_osreproductivos.
ADVERTENCIAPROPOSICI()N65 DECALIFORNIA
Esteproductocontieneo emitequfmicos queel Estado
de Californiasabequecausancancer,defectosde
nacimientou otros dar_osreproductivos.
23
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Generac 005939-0 Owner's manual

Category
Power generators
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI