8.2 When the socket (3-1) is short-cut, the reading on
the display is the value of ambient temperature.
INTELLIGENT
THERMOMETER
This INTELLIGENT THERMOMETER is
small in size, light in weight, easy to carry.
Although complex and advanced, it is
convenient to use and operate. Its ruggedness
will allow many years of use if proper operating
techniques are followed. Please read the
following instructions carefully and always
keep this manual within easy reach.
4. MEASURING PROCEDURE
4.1 Select the thermocouple according to measurement
range.
4.2 Insert the sensor plug into the socket (3-1), taking care
to observe the correct polarity.
4.3 Slide the function switch to MEAS position.
4.4 Plug the sensor to the point measured.
4.5 The reading displayed is the temperature measured.
4.6 To see the maximum Value, just slide the Function
Switch to MAX HOLD position.
4.7 To See the minimum Value, just slide the function
switch to MIN HOLD position.
4.8 To Carry out the Conversion of Celsius temperature or
Fahrenheit temperature, just depress the conver-
sion button (3-3) for a while. Accordingly, the symbol
or will appear on the display.
4.9 Upon completion of measurement, Slide the function
switch to “OFF position.
4.10 Measurement Considerations
When the sensor is first plugged into the thermometer,
or if the senor is changed, the plug must be allowed
to stabilize at the temperature of the socket, which is in
thermal contact with the cold junction compensation
device, for greatest accuracy is to be achieved. This
will only take a couple of minutes and only applies if
the sensor plug has previously been
1. FEATURES
* Can match any . standard type K (Ni Cr Ni Al)
sensor.
* Fitted with standard K probe socket.
* LCD display allows clear read out even at bright
places.
* Used the exclusive MICRO-COMPUTER LSI
circuit and crystal time base to offer the high
accuracy measurement & fast measuring time.
* Wide measuring range & high resolution.
* Digital display gives exact reading with no
guessing or errors.
* The Max. value and Min. value will be automati-
cally stored in memory.
* Of Celsius degree and Fahrenheit degree
conversion.
* The use of durable, long-lasting components,
including a strong, light weight ABS-plastic hous-
ing assures maintenance free performance for
many years. The housing has been carefully shaped
to fit comfortably in either hand.
2. SPECIFICATIONS
Display: 10 mm (0.4") LCD ( Liquid Crystal
Display ) with function annunciation
Range : Its measurement range is determined by
the k type thermocouple selected.
TP – 02 : –50 ~ 750 or 58 ~1382
TP – 03 : –50 ~1100 or 58 ~2012
6
4 1
www.landtek.com.cn
www.landteknet.com
TABLE OF CONTENTS
1. FEATURES........................................
1
2. SPECIFICATIONS................................... 1
3. FRONT PANEL DESCRIPTIONS........... 3
4. MEASURING PROCEDURE................ 4
5. BATTERY RELACEMENT.................... 5
6. ACCESSORIES........................................ 5
7. FUNCTION EXTENDED........................ 5
8. ADDITIONAL STATEMENT.................. 5
exposed to an ambient temperature different to that
of the thermometer.
Note that in common with other thermocouple
thermometers, the accuracy specification applies
only to the instrument itself and allowance must be
made for limits of error permitted in the
thermocouple.
5. BATTERY REPLACEMENT
5.1 When it is necessary to replace the battery (battery
voltage less than approx. 5v ), battery symbol will
appear on the display.
5.2 To loose the screw of the battery cover (3-5) away
from the instrument and remove the battery.
5.3 Install the batteries correctly into the case.
Permanent damage to the circuit from incorrect
installation.
6. ACCESSORIES
Carrying case ………….1 PC
Operation manual………1 PC
Thermocouple …………1 PC ( TP-02)
7. FUNCTION EXTENDED
Normally, Spare button has no use. It is reserved
for later use to satisfy user’s special needs, such as
value set, instant Value hold.
8. ADDITIONAL STATEMENT
8.1 When the thermocouple is not plugged in to the
socket (3-1) , the reading on the display is “1”.
TP – 04 : –50 ~1300 or - 58 ~2372
Accuracy: ±(0.3%n±1) or (0.3%n±1.8)
Resolution: 0.1/(Less than 1000/)
Way displayed: Celsius degree or Fahrenheit
degree.
Operation Temp: 0 ~50 or 32 ~122
Operation Humidity: 85%
Battery: 4x1.5 AA (UM 3) battery
Size: 178x68x39mm
Weight: about 190g (not including batteries)
3.PRONT PANEL DESCRIPTIONS
3-1 Thermocouple socket
3-2 Display
3-3 / conversion button
3-4 Function Switch
3-5 Battery compartment
3-6 Spare button (for later use)
3-7 Thermocouple (Sensor)
3-1
3-2
3-5
3-6
3-7