Fixiure linking
You will need
o seriol doto link to run light shows of one or more fixtures
using
o DMX-512
conîroller
or to
run
synchronized shows on two or more fixtures set to o mosier/slove
operoting
mode. The combined
number
of chqpnels required
by oll the
fixTures
on o seriol doto link determines the number of fixtures the
doto
link
con support.
lmporlonl:
Fixtures
on o seriol doto
link
must be doisy choined in one single line. To comply
with lhe
EIA-485 slondord no more thon 30 devices should be
connected
on one doto link.
Connecling more thon 30 fixtures on
one
seriol doto link wiihout
ihe use of o DMX opiicolly
isoloted
splitter moy result in deteriorotion of the
digitol DMX signol.
Moximum
recommended DMX doto link distonce: 100
meters
Moximum
recommended number
of Compoct
Power
Lightsets on o DMX doto link:
30 fixiures
Doto
Cobling
To link fixTures together
you
must obioin doto
cobles.
You con
purchose
DAP Audio certified DMX cobles
direcily from o deoler/distributor or
construcl
your
own
coble. lf
you
choose to creole
your
own
coble
pleose
use doto-grode cobles ihoi con corry o high
quolity
signol
ond ore less
prone
io
electromognetic
inierference.
DAP Audlo Cerlifled DMX Dolo Cobles
.
DAP Audio coble
for
ollround use. bol. XLR/M 3
p.
>
XLR/F
3
p.
Ordercode FLOl 150
(1,5m.),
FLOl3
(3m.),
FLOl6
(6m.),
FLo1
l0
(.l0m.),
FLOl l5
(15m.),
F10120
(20m.).
.
DAP Audio
coble
for the demonding user with
exceptionol oudio-quolilies ond connecior mode by
Neuirik@. Ordercode FLZI150
(1,5m.),
FLZI3
(3m.),
FL7l6
(6m.).
FLZI l0
(10m.).