Eco Flo EFSWJ10P Owner's manual

Category
Water pumps
Type
Owner's manual
Owner’s Manual
Plastic Shallow
Jet Pumps
General Safety . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . 3-5
Electrical . . . . . . . . . . . . . . . . . . . . . . . . .6
Operation . . . . . . . . . . . . . . . . . . . . . . . . 7
Troubleshooting . . . . . . . . . . . . . . . . . . . 8
Repair Parts . . . . . . . . . . . . . . . . . . . . . . 9
Jet/Tank Assembly . . . . . . . . . . . . . . . . 10
Warranty . . . . . . . . . . . . . . . . . . . . . . . . 11
TABLE OF CONTENTS
Safety: Need safety Info
1. Avoid Pressure Burns/Explosion
2. Avoid Electric Shock
Fill Pump with water: Ensure pump body is lled with water to discharge.
Motor’s Electrical Settings: Set motor to proper voltage,
i.e. voltage supplied to pump – See electrical section
Need Help: Call 1-877-326-3561 for assistance
Important Safety Instructions Safety Labels
Carefully read and follow all safety
instructions in this manual and on pump.
SAVE THESE INSTRUCTIONS – This manual
contains important instructions that should be
followed during installation, operation, and main-
tenance of the product. Save this manual for
future reference.
This is the safety alert symbol. When you
see this symbol on your pump or in this manual,
look for one of the following signal words and be
alert to the potential for personal injury!
Indicates a hazard which, if
not avoided, will result in death or serious injury.
Indicates a hazard which,
if not avoided, could result in death or serious
injury.
Indicates a hazard which, if
not avoided, could result in minor or moderate
injury.
NOTICE indicates practices not related to
personal injury.
Keep safety labels in good condition. Replace
missing or damaged safety labels.
General Safety
Risk of burns. Do not
touch an operating motor. Motors are de-
signed to operate at high temperatures. To
avoid burns when servicing pump, allow it to
cool for 20 minutes after shut-down before
handling.
Do not allow pump or any system compo-
nent to freeze. To do so will void warranty.
Pump water only with this pump.
Periodically inspect pump and system com-
ponents.
Wear safety glasses at all times when work-
ing on pumps.
Risk of explosion. Pump
body may explode if used as a booster
pump.
GENERAL SAFETY
STOP
Before you start
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
2
DEDICATED SHALLOW WELL PUMP INSTALLATIONS
REPLACING AN OLD PUMP
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
Disconnect power to pump before
working on pump or motor.
1. Drain and remove the old pump. Check the old pipe for
scale, lime, rust, etc., and replace it if necessary.
2. Install the pump in the system. Make sure that all pipe
joints in the suction pipe are air-tight as well as water
tight. If the suction pipe can suck air, the pump will not
be able to pull water from the well.
3. Adjust the pump mounting height so that the plumbing
connections do not put a strain on the pump body.
Support the pipe so that the pump body does not take
the weight of piping or ttings.
!
(Figure 1)
Foot Valve
Stainer
Well Casing
Sanitary Well Seal
To Power Box
Suction Pipe
Priming Tee with
Priming Port, Plug
and Pressure
Gauge
To House
Water
System
2 3
Cased Well Installation (Figure 1)
1. Mount the pump as close to the well as possible.
2. Assemble the foot valve, strainer, and well pipe.
Make sure that the foot valve works freely.
3. Lower the pipe into the well until the strainer is ve
feet above the bottom of the well. It should also be at
least 10 feet below the well’s water level.
4. Install a sanitary well seal.
5. Install a priming tee, priming plug, and pressure gauge
to pump’s discharge port. Connect the pipe from the
well to the pump’s suction port, using the fewest
possible ttings-especially elbows – increase friction
in the pipe. The suction pipe should be at least
as large as the suction port on the pump. Support
the pipe so that there are no dips or sags in the pipe,
so not to strain the pump body, and so that it
slopes slightly upward from the well to the pump
(Note: Not doing so can create air locks preventing
the pump from working properly). Seal the suction
pipe joints with PTFE pipe thread sealant tape or a
PTFE-based pipe joint compound. Joints must be air-
and-water-tight. If the suction pipe can suck air,
the pump cannot pull water from well.
6. See instructions on page 8 for connecting discharge
pipe to tank.
DEDICATED SHALLOW WELL PUMP INSTALLATIONS
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
Driven Point Installation (Figure 2)
1. Drive the well point, using “drive couplings” and a “drivecap”.
“Drive ttings” are threaded all the way through and allow the
pipe ends to butt against each other so that the driving
force of the maul is carried by the pipe and not by the threads.
The ordinary ttings found in hardware stores are not threaded
all the way through the tting and can collapse under impact.
“Drive ttings” are also smoother than standard plumbing
ttings, making ground penetration easier.
2 . Mount the pump as close to the well as possible.
3. Use the fewest possible ttings (especially elbows) when
connecting the pipe from the well point to the pump suction
port. The suction pipe should be at least as large as the suction
port on the pump.
4. Install a check valve if your pump is not equipped with one.
5. Install a priming tee, priming plug, and pressure gauge
to pump’s discharge port. Connect the pipe from the
well to the pump’s suction port, using the fewest
possible ttings-especially elbows – increase friction
in the pipe. The suction pipe should be at least
as large as the suction port on the pump. Support
the pipe so that there are no dips or sags in the pipe,
so not to strain the pump body, and so that it
slopes slightly upward from the well to the pump
(Note: Not doing so can create air locks preventing
the pump from working properly). Seal the suction
pipe joints with PTFE pipe thread sealant tape or a
PTFE-based pipe joint compound. Joints must be air-
and-water-tight. If the suction pipe can suck air,
the pump cannot pull water from well.
6. If one well point does not supply enough water,
consider connecting two or three well points to one
suction pipe.
7. See instructions on page 8 for connecting discharge
pipe to tank.
(Figure 2)
Drive Point
Drive
Coupling
Check Valve
To Power Box
Suction Pipe
Priming Tee with
Priming Port,
Plug and Pressure
Gauge
To House
Water
System
4
DEDICATED SHALLOW WELL PUMP INSTALLATIONS
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
Surface Water Installation (Figure 3)
Possible contamination. Do not use
surface water for drinking. The installation
shown could be used for sprinkler applications.
1. The pump should be installed as close to the water
as possible, with the fewest possible ttings (especially
elbows) in the suction pipe. The suction pipe should
be at least as large as the suction port on the pump.
2. Assemble a foot valve and strainer to the suction pipe.
Make sure that the foot valve works freely. Use PTFE
pipe thread sealant tape or a PTFE-based pipe joint
compound on threaded pipe joints.
3. Install a screen to protect the water system from letting
debris enter the system.
4. Lower the pipe into the water until the strainer is ve
feet above the bottom. It should also be at least 10
feet below the water level in order to prevent the pump
from sucking air.
5. Install a priming tee, priming plug, and pressure gauge
to pump’s discharge port. Connect the pipe from the
well to the pump’s suction port, using the fewest
possible ttings-especially elbows – increase friction
in the pipe. The suction pipe should be at least
as large as the suction port on the pump. Support
the pipe so that there are no dips or sags in the pipe,
so not to strain the pump body, and so that it
slopes slightly upward from the well to the pump
(Note: Not doing so can create air locks preventing
the pump from working properly). Seal the suction
pipe joints with PTFE pipe thread sealant tape or a
PTFE-based pipe joint compound. Joints must be air-
and-water-tight. If the suction pipe can suck air,
the pump cannot pull water from well.
6. Joints must be air-and water-tight. If the suction pipe
can suck air, the pump cannot pull water from the
water source.
7. See instructions on page 8 for connecting discharge
pipe to tank.
!
(Figure 3)
Foot Valve
Screen
Water Surface
To Power Box
Suction Pipe
Priming Tee with
Priming Port, Plug
and Pressure
Gauge
To House
Water
System
4 5
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
6
BRANCH
AWG
DISTANCE IN FEET FROM MOTOR TO SUPPLY
MAX. LOAD
FUSE
MIN. WIRE
0-100 101-200 201-300 301-400 401-500
MOTOR HP VOLTS AMP RATING AMP SIZE (mm
2
) AWG WIRE SIZE (mm
2
)
1/2 115/230 10.6/6.5 15/15 12/14 (3/2) 12/14 (8.4/2) 8/14 (2/2) 6/14 (14/2) 6/12 (14/3) 4/10 (21/5.5)
3/4 115/230 11/6.6 20/15 10/14 (5.5/2) 12/14 (8.4/2) 8/14 (8.4/2) 6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5)
1 115/230 11.8/6.7 25/15 10/14 (5.5/2) 6/14 (14/2) 8/14 (8.4/2) 6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5)
ELECTRICAL
Motor Switch Settings (Figure 8)
Motors are designed to run on either 115 volt or 230 volt
current. Be sure the motor’s wires are attached properly to
the motor’s control panel for the voltage required.
Wiring Pressure Switch
Attach the wires from the power source to the pressure
switch following the directions provided under the cover of
the pressure switch, i.e. remove the pressure switch cover
and follow wiring directions under the cover lid. Be sure to
ground wire the pressure switch to the motor.
Wiring the Motor (Figure 9)
Attach wires between the pressure switch and the motor
ensuring the wires are connected to the motor for the proper
electrical source voltage, i.e. 115V or 230V- see the wiring
diagrams in this manual or under the cover of the motor.
Ensure to ground the pressure switch
to the motor.
Disconnect power before working on
pump, motor, pressure switch or wiring
Motor may be hot. Allow to cool 20
minutes.
Water pressure may have built up in
the pump, pipes and/or tank. Drain
water to relieve pressure.
!
!
Wiring
Risk of electric shock.
Can shock, burn or kill.
1. To avoid dangerous or fatal electrical shock, turn OFF
power to motor before working on electrical
connections.
2. Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or
fatal electrical shock hazard.
3. Supply voltage must be within +/- 10% of nameplate
voltage. Incorrect voltage can cause re or damage
motor and voids warranty. If in doubt consult a
licensed electrician.
4. Use wire size specied in Wiring Chart (below). If
possible, connect pump to a separate branch circuit
with no other appliances on it.
5. Do not ground to a gas supply line.
6. Wire motor according to diagram on motor nameplate.
If nameplate diagram diers from diagrams above,
follow nameplate diagram.
7. If this procedure or the wiring diagrams are
confusing, consult a licensed electrician.
Wiring Chart Recommended Wire and Fuse Sizes for 115 and 230 volts
(Figure 9)
Remove Motor
End Plate
Figure 8
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
6 7
Hazardous Pressure,
Install pressure relief valve in discharge pipe.
Release all pressure on system before working on any component.
OPERATION
remove the ll plugs, and rell the pump and piping.
You may have to repeat this two or three times in order
to get all the trapped air out of the piping.
6. When water pressure has built up and is maintained
by the pump, slowly close the pressure regulator control
valve while watching the pressure gauge needle.
Continue closing the valve until you see the pressure
gauge needle start to utter. If the needle starts to
utter, slowly open the valve just enough to stop the
utter. Your pump is now operating at peak eciency.
7. Close all open faucets. After the pump has built up
pressure in the system and shut o, check the
pressure switch operation by opening a faucet or two
and running enough water out to bleed o pressure
until the pump starts. If your jet has a 30/50 pressure
switch, the pump should start when the pressure
drops to 30 PSI and stop when pressure reaches 50
PSI. Run the pump through one or two complete cycles
to verify correct operation. This will also help clean the
system of dirt and scale dislodged during installation.
Risk of burns. Never run pump dry. Run-
ning pump without water may cause pump to overheat,
damaging seal and possibly causing burns to persons
handling pump. Fill pump with water before starting.
Be sure the pump is full of water before
starting the motor.
Risk of explosion and scalding. Never run
pump against closed discharge. To do so can boil water
inside pump, causing hazardous pressure in unit, risk of
explosion and possible scalding persons handling pump.
1. Open the control valve as far as possible. Then remove
the priming plug from the pump and ll the pump, ll
all piping between the pump and the well, and make
sure that all piping in the well is full. If you have also
installed a priming tee in the suction piping, remove
the plug from the tee and ll the suction piping.
2. Replace all ll plugs. Leave the control valve open (in
a shallow well installation, the control valve always
stays open).
3. Turn electric power on!
4. Start the pump. The pump should pump water in two
or three minutes.
5. If you don’t have water after 2 or 3 minutes, stop the
pump and remove the ll plugs. Rell the pump and
piping. You may have to repeat this two or three times
in order to get all the trapped air out of the piping. The
control valve remains open throughout this procedure.
6. After the pump has built up pressure in the system and
shut o, check the pressure switch operation by
opening a faucet or two and running enough water out
to bleed o pressure until the pump starts. If your jet
has a 30/50 pressure switch, the pump should start
when the pressure drops to 30 PSI and stop when pres-
sure reaches 50 PSI. Run the pump through one or two
complete cycles to verify correct operation. This will
also help clean the system of dirt and scale dislodged
during installation.
PREPARING TO START THE PUMP - SHALLOW WELL
PREPARING TO START THE PUMP - DEEP WELL
Risk of burns. Never run pump dry.
Running pump without water may cause pump to overheat,
damaging seal and possibly causing burns to persons
handling pump. Fill pump with water before starting.
Be sure the pump is full of water before
starting the motor.
Risk of explosion and scalding. Never
run pump against closed discharge. To do so can boil water
inside pump, causing hazardous pressure in unit, risk of
explosion and possibly scalding persons handling pump.
1. Open the pressure regulator control valve as far as
possible. Then remove the priming plug from the pump
and ll the pump, ll all piping between the pump and the
well, and make sure that all piping in the well is full.
If you have also installed a priming tee in the suction
piping, remove the plug from the tee and ll the suction
piping.
2. Replace all plugs.
3. Power on!
4. Start the pump and watch the pressure gauge. The
pressure should build rapidly to 50 PSI as the pump
primes.
5. Open several faucets in the residence to permit water
ow and to release trapped air. After 2 or 3 minutes, the
gauge should show pressure. If not, stop the pump,
!
!
!
!
!
!
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
8
CORRECTIVE ACTION
Replace fuse or reset circuit breaker.
DISCONNECT POWER; Replace starting switch
Refer to instructions on wiring (Page 9). DISCONNECT POWER; check and
tighten all wiring. (WARNING symbol) Hazardous voltage. Capacitor voltage may
be hazardous. To discharge capacitor, hold insulated handle screwdriver BY THE
HANDLE and short capacitor terminals together. Do not touch metal screwdriver
blade or capacitor terminals. If in doubt, consult a qualified electrician.
Refer to instructions on wiring.
Check with power company. Install heavier wiring if wire size is too small (See
Electrical/Wiring Chart)
See section below on too frequent cycling.
In new installation:
1. Re-prime according to instructions.
2. Check all connections on suction line and AVC with shaving cream.
3. Replace foot valve or check valve.
In installation already in use:
1. Check all connections on suction line and shaft seal.
2. Lower suction line into water and re-prime. If receding water level in
well exceeds 25’ (7.6M0, a deep well pump is needed.
3. Replace faulty valve.
Clean foot valve or strainer
Clean ejector or impeller.
Replace check valve or foot valve.
Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Raise foot valve and/or strainer above bottom of water source. Clean foot valve
and strainer.
A deep well jet will be needed if your well is more than 25’ (7.6M0 depth to
water.
A new nozzle and venturi combination may be needed.
Replace with plastic pipe where possible, otherwise with new steel pipe.
Use larger piping.
DISCONNECT POWER; adjust or replace pressure switch
Close faucets
Clean venturi, nozzle or impeller
Drain tank to air volume control port. Check AVC for defects. Check all
connections for leaks.
Check connections.
Replace foot valve.
Adjust or replace pressure switch.
DISCONNECT POWER and open faucets until all pressure is relieved. Using tire
pressure gauge, check air pressure in tank at valve stem located on the tank.
If less than pressure switch cut in setting (30-50 PSI), pump air into tank from
outside source until air pressure is 2 PSI less than cut-in setting of switch.
Check air valve for leaks (use soapy solution) and replace core if necessary.
When pump has picked up prime, it should pump solid water with no air.
Suction pipe is sucking air. Check joints for leaks with shaving cream.
Consult factory about installing a sleeve in the well.
Lower foot valve if possible, otherwise restrict pump discharge.
TROUBLE SHOOTING
POSSIBLE CAUSE(S)
Fuse is blown or circuit breaker tripped
Starting switch is defective
Wires at motor are loose, disconnected, or wired
incorrectly
Motor is wired incorrectly
Voltage is too low
Pump cycles too frequently
Pump in new installa tion did not prime due to:
1. Pipes were not filled with water
2. Air leaks
3. Leaking foot valve or check valve
Pump has lost prime through:
1. Air leaks
2. Water level below suction pipe inlet
3. Faulty check or foot valve.
Foot valve or strainer is plugged
Ejector or impeller is plugged
Check valve or foot valve is stuck shut
Pipes are frozen
Foot valve and/or strainer are buried in sand or mud
Water level is too low for shallow well setup to
deliver water
Water level in well is lower than estimated.
Steel piping (if used) is corroded or limed, causing
excess friction
Piping is too small in size
Pressure switch is out of adjustment or contacts
are welded together
Faucets have been left open
Venturi, nozzle or impeller is clogged
Standard pressure tank is waterlogged and has no
air cushion
Pipes leak
Foot valve leaks
Pressure switch is out of adjustment
Air charge too low in pre-charged tank
Pump is not primed
Leak in suction side of pump
Well is gaseous
Intermittent over-pumping of well. (Water drawn
down below foot valve.)
SYSTEM
Motor will not run
Motor runs hot and
overload kicks off
Motor runs but no
water is delivered*
*Stop pump; then check
prime before looking for
other causes. Unscrew
priming plug and see if
water is in priming hole
Pump does not deliver
water to full capacity
(Also check point 3 im-
mediately above)
Pump delivers water but
does not shut off or pump
cycles too frequently
Air spurts from faucets
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
9
SHALLOW WELL PUMP REPAIR PARTS
1
18
234567891011121314
171615
NO. QUANTITY PART NUMBER DESCRIPTION
1 3 EFSWJ5P01 Plug
2 1 EFSWJ5P02 Volute
3 1 EFSWJ5P03 Adapter/Pressure Switch
4 1 EFSWJ5P04 O-Ring
1 EFSWJ5P05 Diffuser for 1/2 HP
5 1 EFSWJ7P05 Diffuser for 3/4 HP
1 EFSWJ7P05 Diffuser for 1 HP
1 EFSWJ5P06 Impeller for 1/2 HP
6 1 EFSWJ7P06 Impeller for 3/4 HP
1 EFSWJ7P06 Impeller for 1 HP
7 1 EFSWJ5P07 Seal
8 1 EFSWJ5P08 O-Ring
9 1 EFSWJ5P09 Seal Plate
10 1 EFSWJ5P10 Base
11 1 EFSWJ5P11 Pressure Tube
12 1 EFSWJ5P12 Adaptor
13 1 EFSWJ5P13 Pressure Switch
14 1 EFSWJ5P14 Nut
15 4 EFSWJ5P15 Screw
16 4 EFSWJ5P16 Washer
1 EFSWJ5P17 Motor for 1/2 HP
17 1 EFSWJ7P17 Motor for 3/4 HP
1 EFSWJ1P17 Motor for 1 HP
18 1 EFSWJ5P18 Plate
10
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
JET/TANK PUMP ASSEMBLY
Tank
1. Remove tank from its carton.
2. Using a tire pressure gauge, check the air in the tank.
It may need to be adjusted once you know the on/o settings on the pump’s pressure switch
(see number 3 below).
Pump
1. Remove the pump from its carton.
2. Retain the pump’s owners manual.
3. Remove the cover from the pump’s pressure switch, and read the on/o settings from the underside of the
pressure switch cover. Typically readings are:
a. Pump (motor) on pressure: 30 PSI (pounds per square inch);
b. Pump (motor) o pressure: 50 PSI.
4. Once you know the turn on/o pressures, alter the air pressure in the empty pre-charge tank to 2 (two) PSI below
the “on” pressure, i.e. to 28 PSI.
5. It is critical the pressure in the tank be 2 PSI below the “tank turn” on pressure
Mounting Kit
1. Remove the kit’s contents and sort them into groups.
Jet Tank Assembly
1. Mount the jet on to the tank securing the jet with the 4 bolts, washers, and nuts provided in the kit.
2. Ensure the input end of the pump is on the same end of the tank input end.
3. Snug the nuts on the bolts while you install other pieces of the kit.
4. Use Teon tape or other plumbing sealant to ensure all connections are sealed.
11
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
1899 Cottage Street, Ashland, Ohio 44805
Telephone: 1-877-326-3561
Fax: 1-877-326-1994
www.ecooproducts.com
Retain Original Purchase Receipt for Warranty Eligibility
Limited Warranty
Manufacturer warrants to the original consumer purchaser (“Purchaser” or “You”) that its products are free from defects in
material and workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within
twelve (12) months from the original consumer purchase, any such product shall prove to be defective, it shall be repaired
or replaced at manufacturer’s option, subject to the terms and conditions set forth herein. Note that this limited warranty
applies to manufacturing defects only and not to ordinary wear and tear. All mechanical devices need periodic parts and
service to perform well. This limited warranty does not cover repair when normal use has exhausted the life of a part or
the equipment.
The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibil-
ity is based on purchase date or original product – not the date of replacement under warranty. The warranty is limited to
repair or replacement of original purchased product only, not replacement product (i.e. one warranty replacement allowed
per purchase).
Purchaser pays all removal, installation, labor, shipping, and incidental charges.
Claims made under this warranty shall be made by contacting and returning the product to the factory immediately after
the discovery or any alleged defect. Manufacturer will subsequently take corrective action as promptly as reasonably pos-
sible. No requests for service will be accepted if received more than 30 days after the warranty expires. Warranty is not
transferable and does not apply to products used in commercial/rental applications.
General Terms and Conditions; Limitations of Remedies
You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does
not apply to the following: (1) acts of God; (2) products which, in manufacturer’s sole judgment, have been subject to
negligence, abuse, accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation,
maintenance or storage; (4) atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or
other foreign materials in the system, or operation at pressures in excess of recommended maximums.
This warranty sets forth manufacturer’s sole obligation and purchaser’s exclusive remedy for defective products.
MANUFACTURER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES
WHATSOEVER. THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS
AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND
BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an
implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specic legal
rights and You may also have other rights which vary from state to state.
WARRANTY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33

Eco Flo EFSWJ10P Owner's manual

Category
Water pumps
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI