CET GFP40 Owner's manual

Type
Owner's manual

CET GFP40 is a digital frequency meter that can be used to continuously calculate and visualize the time in which a specific operation is executed. It is commonly used for translation time adjustment, firing and drying time adjustment, and liquid flow time adjustment.

The device has a front push-button panel made of polycarbonate, which is resistant to scratches, oil, and acids. It has a protection grade of IP 65, meaning it is protected against dust and water jets. The device can be accessed with a software key, and it has removable terminal/octal socket connections. It also has a DIN 48 x 48 execution, recessed assembly, and special retaining brackets.

CET GFP40 is a digital frequency meter that can be used to continuously calculate and visualize the time in which a specific operation is executed. It is commonly used for translation time adjustment, firing and drying time adjustment, and liquid flow time adjustment.

The device has a front push-button panel made of polycarbonate, which is resistant to scratches, oil, and acids. It has a protection grade of IP 65, meaning it is protected against dust and water jets. The device can be accessed with a software key, and it has removable terminal/octal socket connections. It also has a DIN 48 x 48 execution, recessed assembly, and special retaining brackets.

• Front push-botton panel made of polycarbonate
( antiscratch, oil and acid resistant )
• Protection grade IP 65
• Acces to parameters with software key: Time
Reset / Impuls Multiplier / Impuls Division / Display
Up date time / Input type
button
• Removable terminal / octal socket connections
• DIN 48 x 48 execution
• Recessed assembly
• Special retaining brackets
• Inpuls multiplication factor
• Inpuls division factor
• Automatic Time Reset
• Display Up date time
• Input ( Slow / Fast )
• POWER SUPPLY
• SUPPLAY TOLERANCE
• ABSORPTION
• OPERATION TEMPERATURE
• CLIMATIC CONDITIONS
• VISUALIZATION
• MULTIPLICATION FACTOR INPUT IMPULSES
• DIVISION FACTOR INPUT IMPULSES
• TYPE OF INPUTS
• DISPLAY UPDATE DISPLAY
• COUNT FREQUENCY
• MINIMUM TIME FOR IMPULSES COUNT
• CUT - OFF FREQUENCY FOR
ELECTROMECHANIC INPUTS
• PRECISION
• AUXILIARY INPUT SUPPLAY
• PROGRAMMED DATA MEMORY
VISUALIZED DIGITAL
PERIOD TIMER
Type :
GFP40
THE PERIOD TIMER LFT60 IS APPLIED WHERE
IT IS NECESSARY TO CONTINOUSLY
CALCULATE AND VISUALIZE THE TIME IN
WHICH A DETERMINED OPERATION IS
EXECUTED ( NORMALLY A TRANSLATION ),
STARTING FROM A RELATIVE SPEED
MEASUREMENT AND READ THROUGH AN
IMPULSE SENSOR. ITS EASY USE AND
UTMOST FLEXIBILITY MAKE THIS INSTRUMENT
APPROPRIATE FOR MANY DIFFERENT
APPLICATION SUCH AS :
- TRANSLATION TIME ADJUSTMENT
- FIRING AND DRYING TIME ADJUSTMENT, ETC
- LIQUID FLOW TIME ADJUSTMENT ( COUPLED
WITH A CAPACITY TRANSDUCER ).
MAIN FEATURES PROGRAMMABLE PARAMETERS
TECHNICAL FEATURES
: 24 - 110 - 220 Vac ( 50 / 60 Hz )
: 12 Vdc / 24 Vdc available
: + 10 % - 15 %
: 2 W - 3 VA
: - 5 ł˚ C + 55 ˚ C
: U.R. 95 % a 40 ˚ C ( without condensate )
: 4 figures
: from 1 to 9999
: from 1 to 999
: suitable for electromechanical and logical contacts NPN
and PNP
: from 0 to 4 sec.
: from 0,00027 Hz ( 1 impuls by hour ) to 2 KHz Duty
Cycle = 50ł %
: 0,25 mSec.
: about 20 Hz
: 0,1 % ( worst case )
: 12 Vdc - 50 mA available ot terminal
: static ( no battery )
PAGE 1GFP40
PROG
frequencimeter G F P
ENT
RES
CET s.r.l.
QUIT PROGRAMMING
ENT
ENT
ENT
Up - dating time for visualized data, from 0 to 4 sec. included.
If set = 0 visualization is istantaneous.
Delay time for automating resetting , from 0 to 9,9 secs included.
If set = 0 visualization is istantaneus.
Input impuls speed programming:
- S = SLOW : input = 20Hz ( electromechanic contacts )
- F = FAST input 2 Kz or 10 Kz ( logic signal )
PRESS PUSH - BUTTON OUTSIDE PROGRAMMING FOR NEW VALUE ENTERING ACCESS
ENTPROG
RES
- PRESS PUSH BUTTON FOR ABOUT 2 SECS. THE DISPLAY VISUALIZES:
GROUP 2 : ENTER CODE AND PRESS
ENTER WITH AND.
PROG.
020 ENT
FRONT PUSH - BUTTON PANEL
THRESHOLD PROGRAMMING
CALCULATION PARAMETERS PROGRAMMING
PAGE 2 GFP40
PROG
RED
BLUE
YELLOW
YELLOW During programming mode cursor moves to the left.
During normal mode allows temporary visualization of the programmed data
During programming mode increases the flashing figures.
During normal mode visualizes the previously set data on totalizer.
Access and quit from the programming mode .
During programming mode confirms the data and passes to the next ( ENT ).
During normal mode resets the device ( RES ).
RES
ENT
CET s.r.l.
THE PROGRAMMABLE PARAMETERS ARE DIVIDED INTO TWO GROUPS PROTECTED BY A 4 FIGURES CODE
IN ORDER TO OBTAIN ACCESS TO PROGRAMMING, PROCEED AS FOLLOWS :
- PRESS PUSH - BUTTON FOR ABOUT 2 SECS: THE DISPLAY VISUALIZES :
ENT
ENT
Multiplier of impuls are programmable from 1 to 9999
GROUP 1 : ENTER CODE AND PRESS
ENTER CODE WITH AND
PROG
101 ENT
Divisor of impuls are programmable from 1 to 999
QUIT PROGRAMMING
ENTPROG
RES
PRESS PUSH BUTTON OUTSIDE PROGRAMMING FOR NEW VALUE ENTERING ACCESS
PRACTICAL EXAMPLES: ======
1) Display the rotational speed ( revolution per minute ) of a shaft counting pulses from a
proximity switch and using a 24 cog gear-wheel: - set the division factor = 24 - set the multiplier
factor = 60 (1 minute = 60 secs), in order to display the value with a minute time-base
2) Display the linear speed of a conveyor-belt in meters per hour, using a 500 pulses/rev
encoder, with 1 encoder revolution = 33.3 cm.: - set the division factor = 500 - set the multiplier
factor = 1200 ( 1 hour = 3600 secs; 33,3 cm = 1/3 m -> 3600/3 = 1200 ).
PAGE 3GFP40 CET s.r.l.
NOTES
WIRING CONNECTION
PAGE 4 GFP40
frequencimeter G F P
86
67
19
4 5
4 8
4 8
10 Max.
SIDEFRONT
R E T A I N I N G
R E M O V A B L E
T E R M I N A L S
ENT
RES
PROG
B R A C K E T S
4 5
4 5
4 5
4 5
D R I L L T E M P L A T E
B A C K
1 2 3 4
5 6 7 8 9 10
OVERALL DIMENSION ( mm )
0 V
24 V110 V220 V
I N +I N -+ 12 V dc
50 mA
0 V
1
2
3
4 5
6
7
8
A C P O W E R
Z
Max
INPUT SIGNALS
N P N C O N T A C T
P R O X I M I T Y A N D E N C O D E R
A M P L I F I E D - 1 2 V d c
P R O X .
E N C O D.
N P N
354
5 4
6 3
P N P L O G I C
N P N L O G I C
5 4
6 3
P N P C O N T A C T
P R O X .
E N C O D.
P N P
364
3
6
4
5
N P N
P N P
Z
A T T E N T I O N , C O N N E C T :
3 - 6 F O R N P N L O G I C
4 - 5 F O R P N P L O G I C
CET s.r.l.
CET s.r.l.
SS 211 Km 53,550
28071 Borgolavezzaro - No - ITALY
Tel : ++39 321-885180/885301/885807
Fax : ++39 321-885560
Agent :
1098765
1 2 3 4
2 2 0 1 1 0 2 4 0
+ 1 2 V d c
5 0 m A
I N - I N +
A C P O W E R
E
M a x
G N D
4 5
6
7
81
2
3
4 5
4 5
N P N C O N T A C T
P R O X I M I T Y A N D E N C O D E R
A M P L I F I E D - 12 V d c
P R O X .
E N C O D.
N P N
785
8 5
710
P N P L O G I C
N P N L O G I C
8 5
710
P N P C O N T A C T
P R O X .
E N C O D.
P N P
710 5
7
10
5
8
N P N
P N P
A T T E N T I O N , C O N N E C T :
E
7 - 1 0 F O R N P N L O G I C
5 - 8 F O R P N P L O G I C
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

CET GFP40 Owner's manual

Type
Owner's manual

CET GFP40 is a digital frequency meter that can be used to continuously calculate and visualize the time in which a specific operation is executed. It is commonly used for translation time adjustment, firing and drying time adjustment, and liquid flow time adjustment.

The device has a front push-button panel made of polycarbonate, which is resistant to scratches, oil, and acids. It has a protection grade of IP 65, meaning it is protected against dust and water jets. The device can be accessed with a software key, and it has removable terminal/octal socket connections. It also has a DIN 48 x 48 execution, recessed assembly, and special retaining brackets.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI